• 제목/요약/키워드: infrared ray sensor

검색결과 67건 처리시간 0.019초

P(VDF/TrFE) 필름의 두께에 따른 인체 감지형 초전형 PIR 적외선 센서의 특성 (Effect of P(VDF/TrFE) Film Thickness on the Characteristics of Pyroelectric Passive Infrared Ray Sensor for Human Body Detection)

  • 권성열
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.114-117
    • /
    • 2011
  • A thick 25 ${\mu}m$ thickness poled P(VDF/TrFE) film pyroelectric infrared ray sensor has been fabricated and then thin 1.6 ${\mu}m$ thickness P(VDF/TrFE) film pyroelectric infrared ray sensor has been fabricated also. These thick and thin P(VDF/TrFE) film pyroelectric infrared ray sensor was mounted in TO-5 housing to detect infrared light of 5.5 ~ 14 ${\mu}m$ wavelength for human body detecting with each other. The noise output voltage of the thick P(VDF/TrFE) film pyroelectric infrared ray sensor were 380 mV and NEP(noise equivalent power) is $3.95{\times}10^{-7}$ W which is the similar value with the commercial pyroelectric infrared ray sensor using ceramic materials as a sensing material. The NEP and specific detectivity $D^*$ of the thin P(VDF/TrFE) film pyroelectric infrared ray sensor were $2.13{\times}10^{-8}$ W and $9.37{\times}106$ cm/W under emission energy of 13 ${\mu}W/cm^2$ respectively. These result caused by lower thermal diffusion coefficient of a thin 1.6 ${\mu}m$ thickness PVDF/TrFE film than the thick 25 ${\mu}m$ thickness poled P(VDF/TrFE) film pyroelectric infrared ray sensor.

Motion recognition LED lamp technology using infrared ray sensor

  • Zouhaier, Muhamud
    • 한국인공지능학회지
    • /
    • 제4권1호
    • /
    • pp.1-3
    • /
    • 2016
  • These days, citizens are interested in the energy. IT technology needs to develop and to make use of energy effectively and to save energy. In this study, motion recognition LED lamp was used to have good energy efficiency and to be made of environment friendly material. The purpose of development of the lamp was to add motion recognition to LED lamp. In this study, infrared ray sensor's distance measurement was used to develop LED lamp. Most of the lamps were used under dark environment, so that infrared ray sensor was used to perceive movement under dark environment. And, LED lamp with good efficiency and less power consumption was used to increase efficiency. Citizens were interested in perception of the movement to distinguish from conventional type of the lamps.

차동 델타 샘플링 기법을 이용한 비냉각형 적외선 검출회로의 설계에 관한 연구 (A Study on the Design of a ROIC for Uncooled Infrared Ray Detector Using Differential Delta Sampling Technique)

  • 정은식;권오성;이포;정세진;성만영
    • 한국전기전자재료학회논문지
    • /
    • 제24권5호
    • /
    • pp.387-391
    • /
    • 2011
  • A uncooled infrared ray sensor used in an infrared thermal imaging detector has many advantages. But because the uncooled infrared ray sensor is made by MEMS (micro-electro-mechanical system) process variation of offset is large. In this paper, to solve process variation of offset a ROIC for uncooled infrared ray sensor that has process variation of offset compensation technique using differential delta sampling and reference signal compensation circuit was proposed. As a result of simulation that uses the proposed ROIC, it was possible to acquire compensated output characteristics without process variation of offsets.

비분산 적외선 가스 센서 온도 보상법: 적외선 흡수도 (Temperature Compensation of Nondispersive Infrared Gas Senor: Infrared Light Absorbance)

  • 이승환
    • 센서학회지
    • /
    • 제30권1호
    • /
    • pp.36-41
    • /
    • 2021
  • The motivation of this paper is to easily analyze the properties of nondispersive infrared gas sensor that has more than two different optical path length and to suggest the criterion and definition of infrared light absorbance in order to minimize the measurement errors. With the output voltage ratios and the normalized derivatives of infrared ray (IR) absorbance, when the normalized derivatives of IR absorbance decreases from 0.28 to 0.10, the lower and higher limits of errors were decreased from -5.62% and 2.39% to -4.27% and 2.78%. When the normalized derivatives of IR absorbance were 0.10, the output voltage could be partitioned into two regions with one exponential equation and the temperature compensation error was less than 5%.

비냉각형 적외선 센서를 이용한 열상시스템과 냉각형 적외선 센서를 이용한 열상시스템의 화재 진압 시 성능 비교 (Performance Comparison of Thermal Imagers with Uncooled and Cooled Detectors For Fire Fighting Application)

  • 김병혁;정한;김영호
    • 제어로봇시스템학회논문지
    • /
    • 제13권2호
    • /
    • pp.128-132
    • /
    • 2007
  • Thermal Imaging systems are reported to be crucial for fire fighting and beginning to be used by fire fighters. The performance of thermal imaging system is determined by both the radiation of infrared from the target and the attenuation of infrared signal in the optical path by the absorption, scattering, diffraction and reflection. In the scene of fire, water drops with various sizes such as vaporized water, wafer mist from sprinkler, and wafer to suppress the fire reside with various gas generated by burning. To measure the transmission of infrared radiation in the scene of fire, fire simulating system and thermal imagers with cooled detector which detects $3{\sim}5{\mu}m$ infrared and uncooled detector fabricated by the MEMS technology which detects $8{\sim}12{\mu}m$ infrared. are made. With thermal imagers and Ire simulating system, the change of thermal image with respect to the change of visibility controlled with the burned fas was measured. It was found that the transmission of infrared was not reduced by the burned gas, which could be explained by the long wavelength of infrared ray compared with visible ray. However, the transmission of infrared ray was largely reduced by the combination of burned gas and water mist supplied by sprinkler. This is contrary to the results of calculated transmission through the pure water mist and shows that the transmission of infrared ray is mostly affected by the compounds of water mist and burned gas. In this case, it was found that the uncooled detector which detects $8{\sim}12{\mu}m$ infrared ray is better than cooled detector which detects $3{\sim}5{\mu}m$ infrared ray for fire fighting.

An Interactive Physical Computing Based LED CUBE with Infrared Ray Distance Sensor

  • Kim, Soomin;Park, Chun-Su
    • 전기전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.751-755
    • /
    • 2019
  • This paper introduces a LED CUBE tool interacting with a distance sensor to solve real life problems in the physical computing field. Students can experience interactive education and intuitively understand the cubic operations with 3-dimensional animations obtained from a $3{\times}3{\times}3$ LED CUBE and a distance sensor connecting to Arduino. If the proposed LED CUBE is applied in physical computing section of the Information curriculum of middle school, students are expected to improve their computational thinking ability to solve problems in real life and other areas creatively and efficiently.

CCD카메라와 적외선 카메라의 융합을 통한 효과적인 객체 추적 시스템 (Efficient Object Tracking System Using the Fusion of a CCD Camera and an Infrared Camera)

  • 김승훈;정일균;박창우;황정훈
    • 제어로봇시스템학회논문지
    • /
    • 제17권3호
    • /
    • pp.229-235
    • /
    • 2011
  • To make a robust object tracking and identifying system for an intelligent robot and/or home system, heterogeneous sensor fusion between visible ray system and infrared ray system is proposed. The proposed system separates the object by combining the ROI (Region of Interest) estimated from two different images based on a heterogeneous sensor that consolidates the ordinary CCD camera and the IR (Infrared) camera. Human's body and face are detected in both images by using different algorithms, such as histogram, optical-flow, skin-color model and Haar model. Also the pose of human body is estimated from the result of body detection in IR image by using PCA algorithm along with AdaBoost algorithm. Then, the results from each detection algorithm are fused to extract the best detection result. To verify the heterogeneous sensor fusion system, few experiments were done in various environments. From the experimental results, the system seems to have good tracking and identification performance regardless of the environmental changes. The application area of the proposed system is not limited to robot or home system but the surveillance system and military system.

적외선 감지 자동격발장치의 설계 (Design of an Automatic Target Sensing and Triggering System)

  • 홍성한;김권희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1719-1723
    • /
    • 2005
  • An automatic target sensing and triggering system for small fire arms is proposed. The system consists of an optical collector, an infrared ray sensor responsive to human body temperature, an electric actuator and a trigger mechanism. TRIZ methodologies are used to develop solutions to several contradictory problems. Experimental results on the system performance is compared with predictions.

  • PDF

Study on bubble detection sensor for safe sap and blood injection

  • Yun, Young Gi;Lee, Hoo Young;Park, Koo Rack
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권9호
    • /
    • pp.149-154
    • /
    • 2017
  • The infusion of fluid and blood is necessary in the ward, operating room, recovery room, neonatal room, etc. for nutrition and blood supply to the patient, but air bubbles generated during infusion of fluid and blood circulate along the artery or vein. Serious illnesses occur and there is also a risk of death. In this paper, we propose a medical bubble detection system, a bubble detection system, a bubble detection alarm system, and a communication method in order to develop a safer fluid and blood injection system in the existing system, which is detected by a medical staff monitoring system or an ultrasonic bubble detection sensor In this study, infrared rays are transmitted to a tube through a tube for injecting fluid or blood into a patient, infrared rays transmitted by an infrared ray emitting section are received, and the amount of light is measured in real time. Based on the data, we study how to detect and analyze the presence of bubbles in fluid and blood.

Design of Current-Type Readout Integrated Circuit for 160 × 120 Pixel Array Applications

  • Jung, Eun-Sik;Bae, Young-Seok;Sung, Man-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.221-224
    • /
    • 2012
  • We propose a Readout Integrated Circuit (ROIC), which applies a fixed current bias sensing method to the input stage in order to simplify the circuit structure and the infrared sensor characteristic control. For the sample-and-hold stage to display and control a signal detected by the infrared sensor using a two-dimensional (2D) focal plane array, a differential delta sampling (DDS) circuit is proposed, which effectively removes the FPN. In addition, the output characteristic is improved to have wider bandwidth and higher gain by applying a two-stage variable gain amplifier (VGA). The output characteristic of the proposed device was 23.91 mV/$^{\circ}C$, and the linearity error rate was less than 0.22%. After checking the performance of the ROIC using HSPICE simulation, the chip was manufactured and measured using the SMIC 0.35 um standard CMOS process to confirm that the simulation results from the actual design are in good agreement with the measurement results.