• Title/Summary/Keyword: infrared lamp

Search Result 118, Processing Time 0.027 seconds

Motion recognition LED lamp technology using infrared ray sensor

  • Zouhaier, Muhamud
    • Korean Journal of Artificial Intelligence
    • /
    • v.4 no.1
    • /
    • pp.1-3
    • /
    • 2016
  • These days, citizens are interested in the energy. IT technology needs to develop and to make use of energy effectively and to save energy. In this study, motion recognition LED lamp was used to have good energy efficiency and to be made of environment friendly material. The purpose of development of the lamp was to add motion recognition to LED lamp. In this study, infrared ray sensor's distance measurement was used to develop LED lamp. Most of the lamps were used under dark environment, so that infrared ray sensor was used to perceive movement under dark environment. And, LED lamp with good efficiency and less power consumption was used to increase efficiency. Citizens were interested in perception of the movement to distinguish from conventional type of the lamps.

Study on the Performance of Infrared Thermal Imaging Light Source for Detection of Impact Defects in CFRP Composite Sandwich Panels

  • Park, Hee-Sang;Choi, Man-Yong;Kwon, Koo-Ahn;Park, Jeong-Hak;Choi, Won-Jae;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.2
    • /
    • pp.91-98
    • /
    • 2017
  • Recently, composite materials have been mainly used in the main wings, ailerons, and fuselages of aircraft and rotor blades of helicopters. Composite materials used in rapid moving structures are subject to impact by hail, lightning, and bird strike. Such an impact can destroy fiber tissues in the composite materials as well as deform the composite materials, resulting in various problems such as weakened rigidity of the composite structure and penetration of water into tiny cracks. In this study, experiments were conducted using a 2 kW halogen lamp which is most frequently used as a light source, a 2 kW near-infrared lamp, which is used for heating to a high temperature, and a 6 kW xenon flash lamp which emits a large amount of energy for a moment. CFRP composite sandwich panels using Nomex honeycomb core were used as the specimens. Experiments were carried out under impact damages of 1, 4 and 8 J. It was found that the detection of defects was fast when the xenon flash lamp was used. The detection of damaged regions was excellent when the halogen lamp was used. Furthermore, the near-infrared lamp is an effective technology for showing the surface of a test object.

A Study on the Development of Noncontact Soldering Device of PV Cells Using Infrared Lamp (적외선 램프를 이용한 비접촉식 태양전지셀 솔더링 장치 개발에 관한 연구)

  • Lho, Tae-Jung;Kim, Seon-Jin;Park, Min-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.45-50
    • /
    • 2013
  • The reflector of infrared lamp is designed to the optimal circular shape through the analyses of lumination distributions with a triangular, rectangular and circular configurations of infrared lamps respectively by using Photopia. PLC is used to compare and amplify the difference between soldering temperature profile and feedback value. It is fed to IR lamp controller which adjusts the soldering temperature of PV cell. The soldering temperature measured using an infrared temperature sensor is then fed back to the PLC. The closed control loop of soldering temperature on a PV cell is implemented. The noncontact soldering device of PV cells using infrared lamp which is easily operated by HMI operation panel and controlled robustly by PLC and IR lamp controller is developed.

Development of a Flatbed Scanner for Reflection Infrared Photography (반사 적외선 사진을 위한 평판 스캐너의 개발)

  • Choi, Young-Ho;Hwang, Min-Ku;Har, Dong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.57-66
    • /
    • 2011
  • At this time, digital cameras are used in art and forensic science. However, the digital camera has some limitations which need to understand of photograph and lighting. It is a useful paper to make an infrared flatbed scanner. The following processes offer an infrared flatbed scanner development. First, the infrared flatbed scanner changes visible fluorescent lamp to infrared LED. Second, it equips a long-pass filter, which is available to pass over 810nm wavelength, on the glass to complete the optimal infrared flatbed scanner. In addition, it must copy from digital camera to computer directly. The infrared digital camera has disadvantage to always irradiate infrared lamp. Because of difference between visible length and infrared length characteristic, they have different focal distance. This devised scanner for solving mentioned problems does not need to irradiate infrared lamp, and there is not a problem about focal point because the depth of field of flatbed scanner is minimum 2mm. Lastly, the infrared flatbed scanner can make high resolution which is 12,800dpi unlike digital camera. Accordingly, the infrared scanner looks forward to be used in many field of study.

Changes of Pre-Auricular Cutaneous Blood Flow and Skin Temperature after Dry Heat Therapy and Moist Heat Therapy (건열요법과 습열요법 적용후 전이부 표층부 혈류량과 피부온도의 변화)

  • Hong, Yong-Jae;Kim, Cheul;Park, Moon-Soo;Kim, Young-Jun
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.1
    • /
    • pp.47-57
    • /
    • 2006
  • The purpose of this study was to assess the effects of the superficial heat therapy on the cutaneous blood flow and the skin temperature at pre-auricular region. Two types of the superficial heat therapy-moist hot pack & infrared lamp- were applied to 20 healthy subjects(male: 10, female: 10). For each subject, the two parameters of cutaneous blood flow and skin temperature were measured before and after heat therapy, using laser doppler flowmetry(LDF). The author analyzed the differences of the effects between the two therapies and also characteristics of responsiveness between the two parameters. The results were as follows : 1. The two parameters were significantly increased after both superficial heat therapies. 2. Skin temperature showed a maximum peak immediately after both superficial heat therapies, but cutaneous blood flow showed a maximum peak 4 minutes after both superficial heat therapies. 3. Increased cutaneous blood flow after application of moist hot pack lasted longer than infrared lamp. 4. Increased skin temperature after both superficial heat therapies lasted for 60 minutes, but increased skin temperature after infrared lamp decreased more rapidly than moist hot pack. 5. Amount of changes in cutaneous blood flow after infrared lamp was larger in female than in male, but no significant gender difference was found since 20 minutes after infrared lamp. Both moist hot pack and infrared lamp showed favorable effectiveness in raising cutaneous blood flow and skin temperature. Moist hot pack was slightly superior in maintaining this effect.

Discharge and Luminous Characteristics of Coplanar Type Xe Plasma Flat Lamp (면방전형 Xe 플라즈마 평판 램프의 방전 및 발광 특성)

  • Kim, Hyuk-Hwan;Lee, Won-Jong
    • Korean Journal of Materials Research
    • /
    • v.21 no.10
    • /
    • pp.532-541
    • /
    • 2011
  • The Xe plasma flat lamp, considered to be a new eco-friendly LCD backlight, requires a further improvement of its luminance and luminous efficiency. To improve the performance of this type of lamp, it is necessary to understand the effects of the discharge variables on the luminous characteristics of the lamp. In this study, the luminous characteristics of a coplanartype Xe plasma flat lamp with a teeth-type electrode pattern were analyzed while varying the gas composition, gas pressure and input voltage. The effects of the phosphor layer on the discharge and the luminous characteristics of the lamp were also studied. The luminous efficiency of the coplanar-type Xe plasma flat lamp improved as the Xe input ratio and gas pressure increased. Higher luminous efficiency was also obtained when helium (He) was used as a buffer gas and when a phosphor layer was fabricated on the electrode region. In contrast, the luminous efficiency was reduced with increasing the input voltage. It was found that the infrared emissions from the lamp were affected by the Xe excitation rate in the plasma, the Xe gas density, the collisional quenching of excited Xe species by gas molecules, and the recombination rate between the Xe ions and electrons.

Evaluation of illuminant effect of NIR(Near Infrared Radiation) using spectrophotometer for medicine (의학용 분광광도계를 이용한 근적외선 대역의 조명 영향평가)

  • Lee, Sangsik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.4
    • /
    • pp.16-22
    • /
    • 2010
  • In this paper, we evaluated the effect with respect to the light of 700-1,100 nm NIR(near infrared radiation) for spectrophotometer. Standard, red, yellow, green and blue color paper which was Munsell color paper were used for experiments. Our used light is incandescent lamp, fluorescent lamp, invert fluorescent lamp and combined lamp. Each color paper was measured 20 times. Therefore we concluded that it is possible to build a spectrophotometer for NIR(near infrared radiation) measurement we applied an spectrophotometer to measurement system in incandescent lamp.

  • PDF

The Efficiency of External Heat Sources for Infrared Thermography Applied Concrete Structures and the Improvement of the Defect-identification (열화상 기법을 이용한 콘크리트 구조물 결함 검출시 열원의 효율 비교 및 결함검출 능력 향상)

  • Sim, Jun-Gi;Moon, Do-Young;Chung, Lan;Lee, Jong-Seh;Zi, Goangseup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.169-179
    • /
    • 2009
  • The purpose of this paper is to find an efficient heat source to amplify the surface temperature of damaged concrete structures for infrared thermography. we compare two different heat sources of far-infrared lamp and halogen lamp each other for their efficiency. The two heat sources were applied to the concrete specimens. Two different concrete specimens were used: one was the concrete containing internal void and the other was wrapped with partially unbonded fiber reinforced polymer sheet. it was found that the far-infrared lamp was more efficient than the halogen lamp. In addition, we propose a new algorithm to make the damage zone displayed clear in the image obtained from the thermographic operation. The algorithm is a combination of Gauss filtering process and the Prewitt mask operation.

A STUDY ON LAMP BANK DESIGN OF SOLAR SIMULATOR (솔라시뮬레이터의 램프뱅크 설계에 관한 연구)

  • Baek, S.H.
    • Journal of computational fluids engineering
    • /
    • v.17 no.3
    • /
    • pp.45-52
    • /
    • 2012
  • This paper is a study on the design of the solar lamp bank which is a very important part of the solar simulator with the commercial metal halide lamps and infrared lamps. Lamp Bank is designed by the lamp bank design program based on point light source theory. The reliability of the program for lamp bank design is verified through irradiance variation experiments of a kind of lamp according to horizontal distance. Solar lamp bank facilitates heat distribution and satisfies the irradiance in the three wave length which test guidelines require. The shape of the ceiling board next to the lamp bank to promote the lamp cooling efficiency and to reduce temperature deviation and air velocity deviation in the chamber is so creative. The ceiling board of partial closed type is the best among several types.

Comparative Study of Effects of Illumination with Xenon or Sulfur Lamp on Development of Wheat Plants

  • Chen, Qilin;Yu, Xinjian;Chen, Jinxing;Liu, Yuequn;Weng, Jun;Xu, Chunhe
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.394-396
    • /
    • 2002
  • The emission of microwave sulfur lamp is mainly composed of visible light. This lamp producing little infrared radiation, has high light efficiency, long lifespan and less power consumption. In comparison with xenon lamp, growing under sulfur lamp apparently postponed jointing, increased the number of tillers, accelerated root growth of wheat. Relatively, xenon lamp evidently promoted heading and grain maturation. The development characteristics of wheat plant under sulfur lamp were more similar with that in natural condition.

  • PDF