• 제목/요약/키워드: infrared detector

검색결과 318건 처리시간 0.027초

과수원용 차량의 자율주행을 위한 적외선 측거 장치개발 (Development of Infrared Telemeter for Autonomous Orchard Vehicle)

  • 장익주;김태한;이상민
    • Journal of Biosystems Engineering
    • /
    • 제25권2호
    • /
    • pp.131-140
    • /
    • 2000
  • Spraying operation is one of the most essential in an orchard management and it is also hazardous to human body. for automatic and unmanned spraying , an autonomous travelling vehicle is demanded. In this study, a telemeter was developed using infrared beam which could detect trunks and obstacles measure distance and direction from the vehicle travelling in the orchard. The telemeter system was composed of two infrared LED transmitters and receivers, a beam scanning device for continuous object detection , two rotary encoders for angle detector, and a beam level controller for uneven soil surface. The detected distance and direction signal s were sent to personal computer which made for the system display the angular and distance measurements through I/O board. According to a field test in an apple farm, the system detected up to 10m distance under 12 V of transmitted beam intensity, however, it was recommended that the proper beam transmit intensity be 7 v at the 10 m distance, because of the negative effect to human body at 12 V. The error rate of this system was 0.92 % when the actual distance was compared to measured one. The system was feasible at the small error rate. The developed telemeter system was an important part for autonomous travelling vehicle provided the real time object recognition . A direction control system could be constructed suing the system. It is expected that the system could greatly contribute to the development of autonomous farm vehicle.

  • PDF

근적외선 확산반사 분광법을 이용한 흉터치료 평가 (Evaluation of the Scar Treatment using Near Infrared Diffuse Reflectance Spectroscopy)

  • 장익제;윤종인
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권1호
    • /
    • pp.53-60
    • /
    • 2016
  • Monitoring of dermal collagen is important to assess various scar conditions, and many diagnostic methods have been applied to quantify collagen contents in scar tissue. In this study, Monte Carlo simulation was used to evaluate diffuse reflectance distributions in scar condition by a near-infrared laser source. The results showed that the effective distance of the light source and the detector was 2 mm to monitor the various scar conditions using diffuse reflectance spectroscopy. This study may suggest to the optimal design for a near infrared diffuse reflectance spectroscopy during the scar treatment.

OKAYAMA ASTROPHYSICAL OBSERVATORY WIDE-FIELD CAMERA

  • YANAGISAWA KENSHI
    • 천문학회지
    • /
    • 제38권2호
    • /
    • pp.109-112
    • /
    • 2005
  • We present the design, expected performance, and current status of the wide field near-infrared camera (OAOWFC) now being developed at Okayama Astrophysical Observatory, NAOJ, NINS. OAOWFC is a near-infrared survey telescope whose effective aperture is 91cm. It works at Y, J, H, and $K_s$ bands and is dedicated to the survey of long period variable stars in the Galactic plane. The field of view is $0.95 {\times} 0.95 deg^2$ which is covered by one HAWAII-2 RG detector of 2048 ${\times}$ 2048 pixels with the pixel size of $18.5 {\mu}m\;{\times}\;18.5{\mu}m$, that results in the sampling pitch of 1.6 arcsec/pixel. OAOWFC can sweep the area of $840 deg^2$ every 3 weeks, attaining a limiting magnitude of 13 in $K_s$ band. It allows us to observe long period variables embedded in the Galactic plane where interstellar extinction is severe in optical.

주파수 영역 확산광 단층촬영 장치를 이용한 광 팬텀 및 인체조직의 광 계수 측정 (Optical Property Measurements of Optical Phantoms and Honan Tissues Using Frequency-Domain Diffuse Optical Tomography)

  • 호동수;권기운;엄기윤;이승덕;김법민
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.229-234
    • /
    • 2007
  • Diffuse optical tomography (DOT) is a relatively new medical imaging modality which uses near infrared light to image large-sized tissues noninvasively. We constructed a frequency-domain DOT system to measure the optical properties of optical phantoms and human tissues. The FD-DOT uses the intensity-modulated infrared light source that illuminates the biological tissues. The phase shift and modulation changes at each detector site are separately processed to measure the optical properties. The absorption and scattering coefficients are separately estimated using inverse algorithms.

Development of a portable near infrared device for skin moisture by using a microspectrometer

  • Woo, Young-Ah;Suh, Eun-jung;Ahn, Jhii-Weon;Kim, Hyo-Jin
    • 대한화장품학회:학술대회논문집
    • /
    • 대한화장품학회 2003년도 IFSCC Conference Proceeding Book I
    • /
    • pp.203-224
    • /
    • 2003
  • In recent years, a miniature spectrometer has been extensively developed due to the combination of fiber optics and semiconductor detector arrays. This type of miniature spectrometer has advantages of low price and robustness because of the capability of mass production and no moving parts are required such as lenses, mirrors and scanning monochromator. In this study, for skin diagnostics, a portable near infrared (NIR) system has been developed using a LlGA microspectrometer, which is photo-diode arrays-type.(omitted)

  • PDF

Near-infrared photometric properties of red-supergiant stars in nearby galaxies : NGC 4214, NGC 4736, and NGC 5194 / NGC 5195

  • Jung, DooSeok;Chun, San-Hyun;Choudhury, Samyaday;Sohn, Young-Jong
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.62.1-62.1
    • /
    • 2016
  • We study the near-infrared photometric properties of red-supergiant stars (RSGs) in three nearby galaxies located within 15 Mpc: NGC 4214, NGC 4736 and NGC 5194 / NGC 5195. The near-infrared (JHK) imaging data were obtained using the WFCAM detector mounted on UKIRT telescope in Hawaii. We used the DAOPHOT/ALLSTAR pacakge to carry out the photometry. We applied MARCS synthetic fluxes to estimate the effective temperatures and luminosities of the RSGs in all the three galaxies. The results were plotted in the Hertzsprung-Russell(H-R) diagram along with the theoretical evolutionary tracks with different masses. We explore the spatial correlation between the RSGs and H II regions by examing the H-R diagram of the RSGs in the dominant H II regions for each of these three galaxies.

  • PDF

휴대용 근적외선 분광분석기를 이용한 비침투 혈당 측정 (Non-invasive Blood Glucose Measurement by a Portable Near Infrared (NIR) System)

  • 강나루;우영아;차봉수;이현철;김효진
    • 약학회지
    • /
    • 제46권5호
    • /
    • pp.331-336
    • /
    • 2002
  • The purpose of this study is to develop a non-invasive blood glucose measurement method by a portable near infrared (NIR) system which was newly integrated by our lab. The portable NIR system includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector; which was developed by a microchip technology based on the lithography. Reflectance NIR spectra of different parts of human body (finger tip, earlobe, and inner lip) were recorded by using a fiber optic probe. The spectra were collected over the spectral range 1100 ∼ 1740 nm. Partial least squares regression (PLSR) was applied for the calibration and validation for the determination of blood glucose. The calibration model from earlobe spectra presented better results, showing good correlation with a glucose oxidase method which is a mostly used standard method. This model predicted the glucose concentration for validation set with a SEP of 33 mg/dL. This study indicated the feasibility for non-invasive monitoring of blood glucose by a portable near infrared system.

Fourier Transform Infrared Matrix Isolation Study of Acetonitrile in Solid Argon

  • Hack Sung Kim;Kwan Kim
    • Bulletin of the Korean Chemical Society
    • /
    • 제13권5호
    • /
    • pp.520-526
    • /
    • 1992
  • The intramolecular fundamental vibrations of $CH_3CN$ trapped in solid argon matrix have been reinvestigated by means of FT-IR spectroscopy in the spectral range of 4000-500 $cm^{-1}$. By employing a quantum detector, infrared spectra could be obtained at matrix to solute ratio of 10000, allowing the clarification of the peaks due to monomeric species more clearly. Temperature controlled diffusion was initiated to identify the dimeric and polymeric species in terms of difference spectra. The assignments of monomeric and dimeric species are found, in general, to agree with the earlier work performed at higher concentration (Ar/$CH_3CN$ = 1500) using a dispersive spectrometer. Nonetheless the difficulty of minute differences between the earlier infrared and Raman spectroscopic results could be resolved. Moreover, the previously unnotified peaks due to polymeric species have been identified.

InAs/GaSb 응력초격자를 이용한 적외선검출소자의 제작 및 특성 연구 (Fabrication and Device Characteristics of Infrared Photodetector Based on InAs/GaSb Strained-Layer Superlattice)

  • 김준오;신현욱;최정우;이상준;김창수;노삼규
    • 한국진공학회지
    • /
    • 제18권2호
    • /
    • pp.108-115
    • /
    • 2009
  • 150 주기의 InAs/GaSb (8/8-ML) 제2형 응력초격자 (SLS)를 활성층에 탑재한 초격자 적외선검출소자 (SLIP) 구조를 MBE 방법으로 성장하고, 직경 $200{\mu}m$의 개구면을 가지는 SLIP 개별소자를 시험 제작하였다 고분해능 투과전자현미경 (TEM) 이미지의 휘도분포와 X선회절 (XRD) 곡선의 위성피크의 분석 결과는 SLS 활성층은 균일한 층두께와 주기적 응력변형을 유지하는 급격한 계면의 초격자임을 입증하였다. 흑체복사 적외선 광원을 이용하여 측정한 입사파장 및 인가전압에 따른 반응도 (R)와 검출률 ($D^*$)로부터, 차단파장은 ${\sim}5{\mu}m$이고 최대 R과 $D^*$ ($\lambda=3.25{\mu}m$)는 각각 ${\sim}10^3mA/W$ (-0.6 V/13 K)와 ${\sim}10^9cm.Hz^{1/2}/W$ (0 V/13 K)임을 보였다. 반응도의 온도의존성으로부터 분석한 활성화에너지 275 meV는 광반응 과정에 개입되어 있는 가전대 및 전도대 부준위 사이의 에너지 간격 (HH1-C)과 잘 일치하였다.

Evaluation of the KASI Detector Performance Test System Using an Andor iKon M CCD Camera

  • Yu, Young Sam;Kim, Jinsol;Park, Chan;Jeong, Woong-Seob;Kim, Minjin;Choi, Seonghwan;Park, Sung-Joon
    • Journal of Astronomy and Space Sciences
    • /
    • 제35권3호
    • /
    • pp.201-210
    • /
    • 2018
  • The characterization of detectors installed in space- and ground-based instruments is important to evaluate the system performance. We report the development of a detector performance test system for astronomical applications using the Andor iKon M CCD camera. The performance test system consists of a light source, monochromator, integrating sphere, and power meters. We adopted the Czerny-Tuner monochromator with three ruled gratings and one mirror, which covers a spectral range of 200-9,000 nm with a spectral resolution of ~1 nm in the visible region. Various detector characteristics, such as the quantum efficiency, sensitivity, and noise, can be measured in wide wavelength ranges from the visible to mid-infrared regions. We evaluated the Korea Astronomy and Space Science Institute (KASI) detector performance test system by using the performance verification of the Andor iKon-M CCD camera. The test procedure includes measurements of the conversion gain ($2.86e^-/ADU$), full well capacity ($130K\;e^-$), nonlinearity, and pixel defects. We also estimated the read noise, dark current, and quantum efficiency as a function of the temperature. The lowest measured read noise is $12e^-$. The dark current at 223 K was determined to be $7e^-/s/pix$ and its doubling temperature is $5.3^{\circ}C{\pm}0.2^{\circ}C$ at an activation energy of 0.6 eV. The maximum quantum efficiency at 223 K was estimated to be $93%{\pm}2%$. We proved that the quantum efficiency is sensitive to the operating temperature. It varies up to 5 % in the visible region, while the variation increases to 30 % in the near-infrared region. Based on the comparison of our results with the test report by the vendor, we conclude that our performance test results are consistent with those from the vendor considering the test environment. We also confirmed that the KASI detector performance test system is reliable and our measurement method and analysis are accurate.