• Title/Summary/Keyword: inflammable gas

Search Result 31, Processing Time 0.026 seconds

A Study on the Inflammable Gas Explosion Triggered by the Electric Discharge Static Eliminator on Voltage Application Type (전압인가식 제전기의 방전에 의한 가연성가스의 폭발에 관한 연구)

  • Lee Chun Ha;Ok Kyoung Jea;Kim Jum-Ho;Kwon Byung-Duck;Cha Ha-Na;Yun Kea Won
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.22-26
    • /
    • 2004
  • The static eliminator is used for prevention of disasters by static discharge, improvement of production efficiency, protection of a sensitive electronic element on the discharge of static, and it is handled for elimination of static in the painting plant, the film manufacturing plant, the producing semi-conductor factory. This study described on the explosion appearance by discharge phenomena on the voltage input type eliminator's ion generation bar of inflammable gas through an experimental tests. It was used Hydrogen, Ethylene, Propane, Methane gas with the inflammable gas and it was studied on the ignition phenomena by the length of ion-generation static bar, the number of ion-generation electrode and the variation of input voltage to the ion-generation electrode. As a result of this study it was confirmed that the shorter of the bar's length, the greater of explosion danger. And it is considered that there will not ignite at general using inflammable gas, in case of more than 900 mm bar and one electrode.

A study on the explosion proof by the electric discharge on voltage application type (전압인가식 제전기의 방폭화에 관한 연구)

  • Lee Chun Ha;Kim Jum Ho;Park Min Young
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.4 s.25
    • /
    • pp.62-69
    • /
    • 2004
  • It is necessary to eliminate the electric static for the prevention of disasters by electric static discharge, the improvement of production efficiency, the protection of a sensitive electronic devices in the variable manufacturing processes. Then it is handled for elimination of electric static in the painting plant, the film manufacturing plant, the producing semi-conductor factory. This study described on the ideal condition of electric static elimination efficiency by changing of the length of voltage input type eliminator's bar, the length of copper pipe and the gap of electrode and the existence of explosion by inflammable gas with that conditions. As the result, the electric static elimination efficiency has the most ideal value at the 8-11(mm) gap of the earth electrode and needle type electrode each elimination bar and there is not explode at the explosive experiment of inflammable gas with the ideal elimination bar. We can consider that there are some data which are needed for elimination efficiency and it will be able to protect the occurrence of explosion accident inflammable nas in the industrial fields.

  • PDF

Recognization of Inflammable Gases Using Sensor Array and Principal Component Analysis (센서 어레이와 주성분 기법을 이용한 가연성 가스 인식)

  • Lee, Dae-Sik;Huh, Jeung-Soo;Lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.108-117
    • /
    • 2001
  • A sensor array with 10 discrete sensors integrated on a substrate w3s developed for discriminating the kinds and quantities of inflammable gases, like butane, propane, methane, LPG, carbon monoxide. The sensor array consisted of 10 metal oxide semiconductor gas sensors using the nano-sized $SnO_2$ as base material and had differentiated sensitivity patterns to specific gas. The sensor array was designed with uniform thermal distribution and had also high sensitivity and good reproductivity to low gas concentration through nano-sized sensing materials with different additives. By using the sensing patterns of the sensor array at $400^{\circ}C$, we could reliably discriminate the kinds and quantities of the tested inflammable gases under the lower explosion limit through the principal component analysis(PCA).

  • PDF

A Study on the Environmental Characteristic Analysis at Closed Small Sale Landfill Site (소규모 사용종료매립지의 환경특성분석)

  • Jang, Seong-Ho;Cho, Han-Jin;Lee, Chun-Sik
    • Journal of Environmental Science International
    • /
    • v.19 no.7
    • /
    • pp.901-905
    • /
    • 2010
  • Emissions of leachate, odor, and landfill gas(LFG) from an open-dumping landfill site do harm to public health by contaminating neighboring soil, underground water, and rivers. Particularly, methane($CH_4$) and carbon dioxide($CO_2$), the main components of LFG, are especially noted as the causing material of the global warming that become seriously recognized worldwide issue. As one of alternatives in managing LFG, incineration of inflammable wastes that are generated during excavation process at an open-dumping landfill has been evaluated. Standard on stabilization for evaluation, neither $CH_4$ density nor $CO_2$ density could not Because meet 'less than 5%' criterion and so it is right to install a gas collection system during landfill renewal to prevent diffusion of odor and collect it. Because it shows considerable heating value, incineration of inflammable wastes might be the reasonable solution from the result of our study.

Development of Multi Channel Gas Leakage Detector for Large Facility (대규모 시설을 위한 다채널 가스 누설 경보기 개발)

  • Jeong, Kyu-Won
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.3
    • /
    • pp.1-7
    • /
    • 2008
  • As a clean fuel, LNG or LPG is widely used in large restaurants or plants instead of coal. These fuels are easy to use and cheap. However, they are inflammable very much and easily exploded at the worst. So there are many laws and regulations legislated for the handling and usage of the gas facilities. Nevertheless, very harsh explosions occurred in several domestic or foreign places. In this paper a gas detection and alarm system was developed for large facilities. A new concept for connecting many gas detectors was proposed and based upon that a system including hardware and software have been developed and tested. Although up to 16 gas detectors apart 1 km from main controller can be connected currently, this system can be easily expanded for more detectors because each gas detector receiver communicates with main controller using industrial standard RS-485 multi drop technique. Furthermore several additive functions was included for the installation and maintenance convenience.

Gas Sensing Properties of $MgO-Cr_2O_3-TiO_2$ Oxide ($MgO-Cr_2O_3-TiO_2$ 산화물의 가스감지 특성)

  • 양천회;홍필선;유일증;임병오
    • Journal of the Korean Society of Safety
    • /
    • v.1 no.1
    • /
    • pp.21-26
    • /
    • 1986
  • Gas sensing materials for detecting inflammable gas such as alcohol, propane, acetic acid, carbon monoxide, hydrogen were developed by utiliting $MgO-Cr_2O_3-TiO_2$ system. Between 30$0^{\circ}C$ and 50$0^{\circ}C$, reversible chemisorption becomes dominant and the electrical canduction of P-type semiconductive with the gas chemisorption. The ceramic sensor exhibits a high sensitivity to particular reducing gas such as alcohol, whereas propane and butane have little effect on the resistivity. The time response of adsorption is estimated to be about 20 sec. On the other hand, the desorption process, which corresponds to oxidation due to oxygen adsorption, take more than 60 sec. Thus the ceramic sensor can be used as a alcohol sensor in an ambient aunosphere. As the oxygen concentration is increased from 0.1 to 10 precent($10^3-10^6ppm$), the resistance decreases rapidly but stabilizes at higher concentration.

  • PDF

A Study on the Fire Risk Assessment and Prevention in the Recycling Process of Used Refrigerators (냉장고 파쇄 공정에서의 화재 위험성 및 예방에 관한 연구)

  • Lee, Su-Kyung;Song, Dong-Woo;Bae, Jeong-Ae
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.72-77
    • /
    • 2009
  • In the recycling procedure of the refrigerator, the fire frequently breaks out. In this study, to clarify the exact cause of the fire, the components and concentration of the materials produced in the process are analysed as well as the problems in the process system, and the protective measure to prevent the fire and the explosion fundamentally is proposed. In this procedure, the preventive measures of fire by removing the combustible materials such as polyurethane and inflammable gases, by removing the ignition sources and by reducing the oxygen concentration to the minimum are proposed along with the protective measures to reduce the damage in the fire. In the crushing procedure where the fire or explosion can break out in diverse ways, the forced ventilation or exhaust system applied to the small partial ventilation facility are installed to reduce the concentration of inflammable gas mixture to lower than the inflammable limit by injecting and exhausting the air forcibly.

The Quenching Ability of Flame Arrester (화염방지기의 소염성능)

  • Ryu, Eun-Ryeol
    • Fire Protection Technology
    • /
    • s.11
    • /
    • pp.23-30
    • /
    • 1991
  • For the prevent of fire accident or explosion disasters from inflammable gas and vapour, flame arresters are used in chemical equipment, oil tank or other similar installation. The flame arresters have been used mainly wire gauze type. Wire gauze type flame arrestes is affected several factors. We have know that the quenching ability has a great of difference the preference in accordance with flame velocity, direction of flame propagation and wire net of mesh and number of qauze and introduce examination result data quoated from the abroad.

  • PDF

A Study on the Safety Management of High Pressure Underground Pipeline in Industrial Estate (산업단지 고압매설배관 안전관리 향상방안 연구)

  • Choi, Hyun-Woog;Lee, Dong-Min;Kim, jin-jun
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.100-106
    • /
    • 2018
  • pressure buried pipes in domestic industrial estate have many long-term use pipes, Toxic, flammable, Inflammable, etc. as well as a variety of toxic chemicals are embedded in a complex be buried, A high level of safety management is required as it can damage other pipes installed nearby in the event of accidents such as various external interference. Therefore, in this study, the safety management practices of high-pressure gas distribution and urban gas distribution are utilized to derive efficient safety management methods for high-pressure gas installation piping through in-depth comparative analysis.