• 제목/요약/키워드: inexpensive

검색결과 1,271건 처리시간 0.026초

Characteristics of arsenic sorption on furnace slag in groundwater

  • S. R. Kanel;Saurabh Sharma;Park, Hechul
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.96-98
    • /
    • 2002
  • Furnace slag, a steel industry waste, has been converted into an inexpensive and efficient adsorbent. The product obtained has been utilized for the removal of arsenic from ground water. Kinetic studies have bepn described with the mechanism of adsorption The results from batch studies showed that the As(III) can be removed from the ground water within the pH range 3-7 However the maximum removal was experienced at pH 7.0. Equilibrium was attained within 24 hours. Adsorption data of arsenic correlate well with the Freundlich and Langmuir adsorption models. The maximum sorption capacity as calculated using Freundlich adsorption isotherm was found to be of 0.004 mg g-1 at pH 7 and $25^{\circ}C$.

  • PDF

동남해안지역의 피압단열 대수층에서 조석 분석법을 이용한 수리상수 추정

  • 심병완;정상용;성익환;이병대;조병욱
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.497-500
    • /
    • 2003
  • If ground water levels of a confined fractured rock aquifer fluctuate with sea tides, individual values of hydrogeologic parameters can be determined. Tidal efficiency and time lag are first calculated from the water level data recorded at an observation device situated inland from the sea. The tidal efficiency factor of the aquifer at the seacoast is then determined from the observation in monitoring wells and used to calculate storage coefficient. Tidal efficiency factor and the tidal time lag are utilized to calculate storage coefficient and the results are compared. This method is tested in the southeastern coastal area of Busan, Korea. This is a simple and inexpensive way to test confined aquifer but the analysis should be performed according to the coastal environment.

  • PDF

Biobarrier를 이용한 PCE의 환원적 탈염소화시 전자공여체의 영향 (Effect of electron donor for reductive dechlorination of PCE using biobarrier)

  • 황보현욱;신원식;김영훈;송동익
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.391-394
    • /
    • 2003
  • The applicability of in situ microbial filter or biobarrier technology for the remediation of soil and groundwater contaminated with chlorinated solvents was investigated. The efficiency and rates of reductive dechlorination of chlorinated solvents are known to be highly dependent on hydrogen concentration. In this study, the effect of electron donors on the reductive dechlorination of PCE was investigated using vermicompost (worm casting) and peat as permeable reactive barrier medium The effect of organic acids (lactate, butyrate and benzoate), yeast extract and vitamin $B_{l2}$ on the reductive dechlorination was investigated. Compared to the control (no electron donor added), addition of electron donors stimulated the dechlorinated rate. Among the electron donor treatments, lactate/benzoate amendment exhibited the highest dechlorination rate. Since vermicompost and peat are inexpensive and biodegradable and have high sorption capacity, they could be successfully used as biobarrier media, especially when electron donors (for example, lactate/benzoate) are added.d.

  • PDF

Microfluidic Flow Cytometry: Principles of Cell Analysis and Applications

  • Shin, Se-Hyun
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제4권2호
    • /
    • pp.1-6
    • /
    • 2006
  • Microsystems create new opportunities for conventional cell analysis by combining microfluidics and flow cytometry. This article describes recent developments in conventional flow cytometers and related microfluidic flow cytometers to detect, analyze, and sort cells or particles. Flow cytometry strongly consisted of fluidics, optics and electronics requires a large space to equip various components, which are mostly the fluidic components such as compressor, fluid handling system. Adopting microfluidics into flow cytometry enables volume- and power-efficient, inexpensive and flexible analysis of particulate samples. In this paper, we review various efforts that take advantage of novel techniques to build microfluidic cell analysis systems with high-speed analytical capability. Highly integrated microfluidic cytometry shows great promise for basic biomedical and pharmaceutical research, and robust and portable point-of-care devices could be used in clinical settings.

  • PDF

매스콘크리트의 온도균열 예측해석에서의 전후처리 시스템 개발에 관한 연구 (Pre- and Post Processing System on Prediction Analysis of Thermal Stress in Mass Concrete Structure)

  • 김유석;강석화;박칠림
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.270-274
    • /
    • 1996
  • Until recently pre & post-processing of finite element model has been heavily relied on expensive graphic peripheral devices. But today, with the aid of inexpensive microcomputers, very effective pre & postprocessor graphics has been developed. In this study, Pre & Post processor(MASSPRE, MASSPOST) of prediction analysis of thermal stress in mass concrete structure is developed. The developed pre & post processors are raise to the efficiency in making input data for the main program and analysis of the results produced by the main program. This MASSPOST presents a stress contour graph, volume slice, time-temperature history graph, time-stress history graph, etc.

  • PDF

다중 GPS를 이용한 무인자동차의 주행 알고리즘 개발 (The Development of Driving Algorithm for an Unmanned Vehicle with Multiple-GPS's)

  • 문희창;손영진;김정하
    • 제어로봇시스템학회논문지
    • /
    • 제14권1호
    • /
    • pp.27-35
    • /
    • 2008
  • A navigation system is one of the important components of an unmanned ground vehicle (UGV). A GPS receiver collects data signals transmitted by (Earth orbiting) satellites. However, these data signals may contain many errors resulting misinformation and depending on one's position (environment), reception may be impossible. The proposed self-driven algorithm uses three low-cost GPS in order to minimize errors of existing inexpensive single GPS's driving algorithm. By using reliable final data, which is analyzed and combined from each of three GPS's received data signals, gathering a vehicle's steering performance information and its current pin-point position is improved even with error containing signals or from a place where signal gathering is impossible. The purpose of this thesis is to explain navigation system algorithm using multiple GPS and compass sensor and prove the algorithm through experiments.

Annealing Effect on Structural, Electrical and Optical Properties of CdS Films Prepared by CBD Method

  • Haider, Adawiya J.;Mousa, Ali M.;Al-Jawad, Selma M.H.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제8권4호
    • /
    • pp.326-332
    • /
    • 2008
  • In this work CdS films were prepared by using chemical bath deposition, which is simple and inexpensive technique suitable for large deposition area. Annealing in air at different temperatures (300, 350, 400, 450 and $500^{\circ}C$) at constant time of 30 min, also for different times (15, 30, 45, 60 and 90 min) at constant temperature ($300^{\circ}C$) is achieved. X-Ray analysis has confirmed the formation of cadmium oxide (CdO) with slight increase in grain size, shift towards lower scattering angle due to relaxation in the tensile strain for deposition films, and structure change from cubic and hexagonal to the hexagonal. From electrical properties, significant increase in electrical conductivity appeared in samples annealed at $300^{\circ}C$ for 60 min, and at $350^{\circ}C$ for 30 min.

修正된 아자이드 Winkler 법과 폴라로그래피에 의한 溶存酸素의 측정에 관한 하이드록실아민의 영향 (Hydroxylamine Effect on the Determination of Dissolved Oxygen by the Azide-Modified Winkler Method and Polarography)

  • Chung, Keun Ho;Ree, Jony Iuir;Kim, Chun Seek
    • 한국환경보건학회지
    • /
    • 제12권2호
    • /
    • pp.11-15
    • /
    • 1986
  • Hydroxlamine effect on the determination of dissolved oxygen by the azide-modified Winkder method and polarography has been studied. It was found that hydroxylamine interference on the dissolved oxygen by the azide-modified Winklet method can be eliminated completely by using permanganate. An inexpensive and convenient polarograph device was constructed. Dissolved oxygen in an air-saturated 0.1 F KCl solution undergoes, independent of hydroxylamine concentrations a two-step irreversible reduction at the dropping electrode the $H_2O_2$ produced in the first step is reduced to $H_2$O in the second. Two waves of equal size result, the first with a half-wave potential (E1/2) at about -0.13 V and the second at about -0.91 V (vs. SCE).

  • PDF

Application of a Compatible Xylose Isomerase in Simultaneous Bioconversion of Glucose and Xylose to Ethanol

  • Chandrakant Priya;Bisaria Virendra S.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제5권1호
    • /
    • pp.32-39
    • /
    • 2000
  • Simultaneous isomerisation and fermentation (SIF) of xylose and simultaneous isomerisation and cofermentation (SICF) of glucose-xylose mixture was carried out by the yeast Saccharomyces cerevisiae in the presence of a compatible xylose isomerase. The enzyme converted xylose to xylulose and S. cerevisiae fermented xylulose, along with glucose, to ethanol at pH 5.0 and $30^{\circ}C$. This compatible xylose isomerase from Candida boidinii, having an optimum pH and temperature range of 4.5-5.0 and $30-35^{\circ}C$ respectively, was partially purified and immobilized on an inexpensive, inert and easily available support, hen egg shell. An immobilized xylose isomerase loading of 4.5 IU/(g initial xylose) was optimum for SIF of xylose as well as SICF of glucose-xylose mixture to ethanol by S. cerevisiae. The SICF of 30 g/L glucose and 70 g xylose/L gave an ethanol concentration of 22.3 g/L with yield of 0.36 g/(g sugar consumed) and xylose conversion efficiency of $42.8\%$.

  • PDF

9채널 UHF 센서를 적용한 염가형 GIS 부분방전 진단 시스템 개발 (A developments of inexpensive GIS partial discharge diagnostic system using the 9 Channel UHF sensors)

  • 김홍석;오재훈;홍정기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2021-2022
    • /
    • 2008
  • UHF기법을 적용한 GIS 부분방전 진단 시스템은 가스절연 개폐장치(GIS: Gas Insulated Switchgear) 내부에서 발생하는 부분방전 신호를 측정하여 부분방전 원인을 진단한다. 이러한 부분방전 진단 시스템은 부분방전 신호를 UHF 대역의 고주파/위상 영역에서 분석하여 Digital 신호로 변환하기 때문에 고가의 분석 장비가 필요하므로 시스템의 설치 및 유지 보수비용이 많다. 따라서 부분방전 진단 시스템의 설치에 대하여 대중화하기 어려우며 GIS의 이상 상태가 발생하기 전에는 측정 데이터의 활용이 미비하다. 본 논문에서는 이러한 부분방전 시스템의 설치비용을 절감하고자 센서의 측정을 시간별로 변경하여 측정하는 염가형 부분방전 진단 시스템의 구성에 대하여 기술하며 대용량 데이터의 관리 방안에 대하여 기술한다.

  • PDF