• 제목/요약/키워드: inelastic seismic analysis

검색결과 307건 처리시간 0.029초

역V형 철골 중심가새골조의 정적/동적 지퍼기둥.설계법 (Staticand Dynamic Design of Zipper Columns in Inverted V Braced Steel Frames)

  • 이철호;김정재
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.733-740
    • /
    • 2006
  • Inverted V (or chevron) braced steel frames have been seen as being highly prone to soft story response once the compression brace buckles under earthquake loading. To salvage chevron braced frames. the concept of the zipper column was proposed many years ago such that the zipper column can redistribute the inelastic demand over the height of the building. However. rational design method for the zipper column has not been established yet. In this paper, a new dynamic design method for the zipper column was proposed by combining the refined physical braced model and modal pushover analysis. Inelastic dynamic analysis conducted on 6 story building model showed that the proposed method was more superior to the existing static design method and was very effective in improving seismic performance of chevron braced steel frames.

  • PDF

ISSUES IN PROBABILISTIC SEISMIC HAZARD ANALYSIS FOR NUCLEAR FACILITIES IN THE US

  • Mcguire, Robin K.
    • Nuclear Engineering and Technology
    • /
    • 제41권10호
    • /
    • pp.1235-1242
    • /
    • 2009
  • Probabilistic seismic hazard analysis (PSHA) is routinely conducted in the US for nuclear plants, for the determination of appropriate seismic design levels. These analyses incorporate uncertainties in earthquake characteristics in stable continental regions (where direct observations of large earthquakes are rare), in estimates of rock motions, in site effects on strong shaking, and in the damage potential of seismic shaking for engineered facilities. Performance goals related to the inelastic deformation of individual components, and related to overall seismic core damage frequency, are used to determine design levels. PSHA has the ability to quantify and document the important uncertainties that affect seismic design levels, and future work can be guided toward reducing those uncertainties.

현행 내진설계 규준에서 요구되는 수평강도의 평가 방법 (Method of Evaluation of the Strength Required in Current Seismic Design Code)

  • 한상환
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1997년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 1997
    • /
    • pp.193-200
    • /
    • 1997
  • Current seismic design code is based of the assumption that the designed structures would be behaved inelastically during a severe earthquake ground motion. For this reason, seismic design forces calculated by seismic codes are much lower than the forces generated by design earthquakes which makes structures responding elastically. Present procedures for calculating seismic design forces are based on the use of elastic spectra reduced by a strength reduction factors known as "response modificaion factor". Because these factors were determined empirically, it is difficult to know how much inelastic behaviors of the structures exhibit. In this study, base shear forces required to maintain target ductility ratio were first calculated from nonlinear dynamic analysis on the single degree of freedom system. And then, base shear foeces specified in seismic design code compare with above results. If the strength(base shear) required strength should be filled by overstrength and/or redundancy. Therefore, overstrength of moment resisting frame structure will be estimated from the results of static nonlinear analysis(push-over analysis).analysis).

  • PDF

Assessment of FEMA356 nonlinear static procedure and modal pushover analysis for seismic evaluation of buildings

  • Khoshnoud, Hamid Reza;Marsono, Kadir
    • Structural Engineering and Mechanics
    • /
    • 제41권2호
    • /
    • pp.243-262
    • /
    • 2012
  • Nonlinear static analysis as an essential part of performance based design is now widely used especially at design offices because of its simplicity and ability to predict seismic demands on inelastic response of buildings. Since the accuracy of nonlinear static procedures (NSP) to predict seismic demands of buildings affects directly on the entire performance based design procedure, therefore lots of research has been performed on the area of evaluation of these procedures. In this paper, one of the popular NSP, FEMA356, is evaluated and compared with modal pushover analysis. The ability of these procedures to simulate seismic demands in a set of reinforced concrete (RC) buildings is explored with two level of base acceleration through a comparison with benchmark results determined from a set of nonlinear time history analyses. According to the results of this study, the modal pushover analysis procedure estimates seismic demands of buildings like inter story drifts and hinges plastic rotations more accurate than FEMA356 procedure.

Energy dissipation system for earthquake protection of cable-stayed bridge towers

  • Abdel Raheem, Shehata E.;Hayashikawa, Toshiro
    • Earthquakes and Structures
    • /
    • 제5권6호
    • /
    • pp.657-678
    • /
    • 2013
  • For economical earthquake resistant design of cable-stayed bridge tower, the use of energy dissipation systems for the earthquake protection of steel structures represents an alternative seismic design method where the tower structure could be constructed to dissipate a large amount of earthquake input energy through inelastic deformations in certain positions, which could be easily retrofitted after damage. The design of energy dissipation systems for bridges could be achieved as the result of two conflicting requirements: no damage under serviceability limit state load condition and maximum dissipation under ultimate limit state load condition. A new concept for cable-stayed bridge tower seismic design that incorporates sacrificial link scheme of low yield point steel horizontal beam is introduced to enable the tower frame structure to remain elastic under large seismic excitation. A nonlinear dynamic analysis for the tower model with the proposed energy dissipation systems is carried out and compared to the response obtained for the tower with its original configuration. The improvement in seismic performance of the tower with supplemental passive energy dissipation system has been measured in terms of the reduction achieved in different response quantities. Obtained results show that the proposed energy dissipation system of low yield point steel seismic link could strongly enhance the seismic performance of the tower structure where the tower and the overall bridge demands are significantly reduced. Low yield point steel seismic link effectively reduces the damage of main structural members under earthquake loading as seismic link yield level decreases due their exceptional behavior as well as its ability to undergo early plastic deformations achieving the concentration of inelastic deformation at tower horizontal beam.

The length of plastic hinge area in the flanged reinforced concrete shear walls subjected to earthquake ground motions

  • Bafti, Farzad Ghaderi;Mortezaei, Alireza;Kheyroddin, Ali
    • Structural Engineering and Mechanics
    • /
    • 제69권6호
    • /
    • pp.651-665
    • /
    • 2019
  • Past earthquakes have shown that appropriately designed and detailed buildings with shear walls have great performance such a way that a considerable portion of inelastic energy dissipation occurs in these structural elements. A plastic hinge is fundamentally an energy diminishing means which decrease seismic input energy through the inelastic deformation. Plastic hinge development in a RC shear wall in the areas which have plastic behavior depends on the ground motions characteristics as well as shear wall details. One of the most generally used forms of structural walls is flanged RC wall. Because of the flanges, these types of shear walls have large in-plane and out-of-plane stiffness and develop high shear stresses. Hence, the purpose of this paper is to evaluate the main characteristics of these structural components and provide a more comprehensive expression of plastic hinge length in the application of performance-based seismic design method and promote the development of seismic design codes for shear walls. In this regard, the effects of axial load level, wall height, wall web and flange length, as well as various features of earthquakes, are examined numerically by finite element methods and the outcomes are compared with consistent experimental data. Based on the results, a new expression is developed which can be utilized to determine the length of plastic hinge area in the flanged RC shear walls.

주철근 겹침이음을 갖는 철근콘크리트 교각의 비탄성 거동 및 연성능력에 관한 해석적 연구 (Analytical Study on Inelastic Behavior and Ductility Capacity of Reinforced Concrete Bridge Columns with Lap Splices)

  • 김태훈;김운학;신현목;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.931-936
    • /
    • 2003
  • Lap splices were located in the plastic hinge region of most bridge piers that were constructed before the adoption of the seismic design provision of Korea Highway Design Specification on 1992. Lap splicing is also permitted if hoops or spiral reinforcement are provided over the lap length in the current seismic design provision. But sudden brittle failure of lap splices may occur under inelastic cyclic loading. The purpose of this study is the analytical prediction of nonlinear hysteretic behavior and ductility capacity of reinforced concrete bridge piers with lap splices under cyclic loading. For this purpose, a nonlinear analysis program, RCAHEST(Reinforced Concrete Analysis in Higher Evaluation System Technology) is used. Lap spliced bar element is developed to predict behaviors of lap spliced bar. Maximum bar stress and slip of lap spliced bar is considered.

  • PDF

비정형 RC 건축구조물의 비선형 지진응답 평가를 위한 개선된 횡하중 분배 방법 (Improved Distribution of Lateral Seismic Forces for Evaluation of Inelastic Seismic Response of RC Irregular Building Structures)

  • 최원호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.322-329
    • /
    • 2000
  • Current seismic design codes for building structures are based on the methods which can provide enough capacity to satisfy objected performance level and exactly evaluate the seismic performance of buildings. Pushover analysis of fast becoming an accepted method for the seismic evaluation of building structures. The popularity of this approximate, nonlinear static analysis method is due to its conceptual simplicity and ability to graphically describe a capacity and demand of structure. However, some of the shortcomings of the pushover analysis, especially for longer period and irregular buildings, is the inability of method to identify failure mechanisms due to effects of higher modes. In this paper proposed lateral load pattern which includes the contribution of higher modes of vibration for irregular building structure and compared to seismic response obtained by time history.

  • PDF

강재 모멘트 골조의 비선형 지진 해석을 위한 부등단면 보 요소 II: 모델의 검증 (Non-Prismatic Beam Element for Nonlinear Seismic Analysis of Steel Moment Frames II: Verification of Model)

  • 황병국;전충하;김기동;고만기
    • 한국방재학회 논문집
    • /
    • 제7권5호
    • /
    • pp.37-46
    • /
    • 2007
  • 본 연구는 강재 모멘트 골조의 비선형 지진 해석을 위한 부등단면 보 요소에 관한 두 개의 동반논문 중에서 두 번째 논문이다. 동반논문에서는 지진운동 하의 단면감소(RBS) 강재 보의 탄성 및 비탄성 거동을 정의하기 위한 부등단면 보(RBS 보) 요소를 제시하였고 본 연구에서는 RBS 보 요소에 대한 항복면, 강성 변수, 그리고 경화(혹은 연화) 법칙 변수의 결정과정을 기술하였고 RBS 보 요소의 해석결과를 실험 및 유한요소 해석(FEM) 결과와 비교하였다. RBS 보 요소의 해석결과는 실험 및 FEM 결과와 좋은 상관관계를 보였다.

비내진 상세를 가진 1:12축소 10층 R.C.골조의 비선형 거동에 대한 실험과 해석의 상관성 (Correlation of Experimental and Analytical Inelastic Responses of A 1:12 Scale 10-Story Reinforced Concrete Frame with Non-seismic Details)

  • 이한선;강귀용
    • 콘크리트학회지
    • /
    • 제11권1호
    • /
    • pp.267-277
    • /
    • 1999
  • 현재 일방향 가력 해석기법은 세계적으로 기존 건물의 지진평가를 위해 구조물의 탄성 및 비탄성 거동을 예측하는데 가장 유용한 방법이다. 그러나, 이 해석기법은 특히 비내진 상세를 가진 철근콘크리트 골조에 대해 실험결과와 충분히 검토되지 않았다. 본 연구의 목적은 비내진 상세를 가진 고층 R.C. 골조에 대해 실험과 해석의 상관성을 검증하는데 있다. 본 연구의 목적은 DRAIN-2DX를 이용한 해석결과와 이미 수행된 비내진 상세를 가진 1:12축소 10층 철근콘크리트 골조의 실험결과를 서로 비교, 검토함으로써 그 응용상의 문제점과 신뢰성을 확인하는 데 있다. 본 연구는 실험과 해석의 상호 비교결과 다음과 같은 결론을 얻었다. 충전단력과 층간변위 및 소성회전각 같은 국부 변형의 전체적인 거동은 실험결과와 해석결과가 잘 일치하는 것으로 나타났다.