• Title/Summary/Keyword: industrial water

Search Result 4,746, Processing Time 0.033 seconds

Development of a System Dynamics Computer Model for Efficient Operations of an Industrial Water Supply System (공업용수 공급시스템의 효율적인 운영을 위한 시스템다이내믹스 모형의 개발)

  • Kim, Bong-Jae;Park, Su-Wan;Kim, Tae-Yeong;Jeon, Dae-Hun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.383-397
    • /
    • 2012
  • In this study, a System Dynamics (SD) simulation model for the efficient operations of an industrial water supply system was developed by investigating the feedback loop mechanisms involved in the operations of the system. The system was modeled so that as demand is determined the water supply quantity of intake pumping stations and dams are allocated. The main feedback loop showed that many variables such as the combinations of pump operation, unit electric power(kWh/$m^3$), unit electric power costs(won/$m^3$), water level of water way tunnel, suction pressure and discharge of pumping station, and tank and service reservoir water level had causal effects and produced results depending on their causal relationship. The configurations of the model included an intake pumping station model, water way tunnel model, pumping station model (including the tank and service reservoir water level control model), and unit electric power model. The model was verified using the data from the case study industrial water supply system that consisted of a water treatment plant, two pumping stations and four dams with an annual energy costs of 5 billion won. It was shown that the electric power costs could have been saved 7~26% during the past six years if the operations had been based on the findings of this study.

Determination of Optimal Time to Replace On-S Water Pipeline by Analyzing Water Main Failures and Economical Efficiency (수도사고 분석 및 경제성 평가를 통한 상수관로 최적 교체시기 결정)

  • Kim, Jong-Sin;Jung, Kwan-Sue;Bae, Chul-Ho;Lee, Doo-jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.279-285
    • /
    • 2009
  • In this study, applied to the industrial water service, it is verified feasibility of break-even analysis method which has not been introduced in Korea. The On-san water pipeline of 7.1km among the Ul-san industrial water service is selected and the optimal replacement time calculated by break-even analysis method is year 2033 to 2044 which will be 53 to 67 years since the pipes were buried. If indirect cost such as the value of lost water and traffic disruption, service interruption, etc. is calculated as 30 and 100% of the direct cost, the financially optimum replacement time is advanced 3 to 9 years. These ways present rational criteria to establish long-term plan for budget and to execute the limited budget efficiently.

Compatibility inspection for the way for Decision about Bight Flow Profile of Standard River Design (하천설계기준의 만곡부 수면형 결정 방법에 대한 적용성 검증)

  • Choi, Han-Kuy;Che, Hong-Gi;Baek, Hyo-Sun
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.43-51
    • /
    • 2006
  • Through the result of calculating the deviation between the value calculated from two-dimensional number formula, one-dimensional number interpretation, and curving part water surface type calculation method, we could confirmed that the deviation is reduced more than 50% when we use curving part water surface type calculation method. Also it was confirmed that there occurs the reduction rate of maximum 59% as the result of comparing with one-dimensional number interpretation since the reduction rate of safe room height was 20%, in 500 CMS of flood water quantity when we planted the construction of levee by curving part water surface type calculation method. And therefore, we have confirmed that the curving water surface type calculation method can be used as a simple formula in rivers with water quantity less than 500 CMS that flows in and out in Jess than 90 degree angle.

  • PDF

Water Pollution and Economic Growth in Western China

  • Lu, Xing;Lei, Shi;Weili, Ye
    • Environmental and Resource Economics Review
    • /
    • v.16 no.3
    • /
    • pp.629-641
    • /
    • 2007
  • Chinese government has implemented the West Development Strategy since 1999 to boost the region's growth and prevent the environmental degradation. Until now, the regional economy and living standard in Western China have been greatly improved, while it also indicated by the State Council that the ecological environment still deteriorated with part improvement, and pressure of water shortage increased. The paper focus on the relationship of GDP per capita and the volume of industrial waste water discharge of all the 12 provinces in Western China from 1989 to 2004, by the expanded EKC model in the cubic form. Results show that they mainly have down trend in the whole sample space but small up trend in the recent years. That means controlling of industrial wastewater discharge is still an important task to be insisted in the Western China.

  • PDF

Empirical Analysis on the Industrial Productivity in the Electricity·Gas·Water Service Sector

  • Zhu, Yan Hua;Kang, Joo Hoon;Park, Sehoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.4
    • /
    • pp.25-37
    • /
    • 2015
  • The early studies indicated that the firm with monopoly power is likely to engage in X-inefficiency such as a managerial slack. The reflection of the X-inefficiency theory has led to the issue that the public sector may be more inefficient than the private sector. In Korea like other many countries the electricity gas water service which can be considered as natural monopoly have been provided mostly by the public sector. In order to provide the empirical evidence to the argument that the public sector may be more inefficient than the private sector this paper estimated the four types of Solow residual which is called the total factor productivity in the electricity gas water service industry with the associated empirical model and compared its productivity with one in the manufacturing industry. The empirical results do not support the argument that the public sector may be more inefficient or less productive than the private sector.

APPLICATION OF TUBULAR MEMBRANE FILTRATION TO LNDUSTRIAL WASTE WATER TRATMENT (산업폐수에 관형막 분리응용)

  • 지은상
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1991.10a
    • /
    • pp.58-63
    • /
    • 1991
  • Membrane technology has been effectively used for many years in certain segments of industrial water treatment. Recent advances in combining sophisticated chemical pre-treatment technology with cross-flow membrane filtration technology have successfully demonstrated that highly efficient, low-cost methods for treating a large of industral streams are available.

  • PDF

Electrochemical Characteristics of Solid Polymer Electrode Fabricated with Low IrO2 Loading for Water Electrolysis

  • Ban, Hee-Jung;Kim, Min Young;Kim, Dahye;Lim, Jinsub;Kim, Tae Won;Jeong, Chaehwan;Kim, Yoong-Ahm;Kim, Ho-Sung
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.22-28
    • /
    • 2019
  • To maximize the oxygen evolution reaction (OER) in the electrolysis of water, nano-grade $IrO_2$ powder with a low specific surface was prepared as a catalyst for a solid polymer electrolyte (SPE) system, and a membrane electrode assembly (MEA) was prepared with a catalyst loading as low as $2mg\;cm^{-2}$ or less. The $IrO_2$ catalyst was composed of heterogeneous particles with particle sizes ranging from 20 to 70 nm, having a specific surface area of $3.8m^2g^{-1}$. The anode catalyst layer of about $5{\mu}m$ thickness was coated on the membrane (Nafion 117) for the MEA by the decal method. Scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS) confirmed strong adhesion at the interface between the membrane and the catalyst electrode. Although the loading of the $IrO_2$ catalyst was as low as $1.1-1.7mg\;cm^{-2}$, the SPE cell delivered a voltage of 1.88-1.93 V at a current density of $1A\;cm^{-2}$ and operating temperature of $80^{\circ}C$. That is, it was observed that the over-potential of the cell for the oxygen evolution reaction (OER) decreased with increasing $IrO_2$ catalyst loading. The electrochemical stability of the MEA was investigated in the electrolysis of water at a current density of $1A\;cm^{-2}$ for a short time. A voltage of ~2.0 V was maintained without any remarkable deterioration of the MEA characteristics.

Water Quality Evaluation on the Bottom Water of Masan Bay by Multivariate Analysis (다변량 해석에 의한 마산만 저층수의 수질평가)

  • Lee, Mu-kang;Hwang, Jeung-Wook;Choi, Young-Kwang
    • Journal of Environmental Science International
    • /
    • v.5 no.1
    • /
    • pp.15-23
    • /
    • 1996
  • During the last two decades, many industrial complexes for heavy and chemical industries have been established along the Korean coastline, thereby increasing the pollution materials burden on the coastal environment of seawater. Masan Bay is one of the most polluted coastal areas in Korea and the main soures of pollutants are domestic and industrial wastewater from Masan, Changwon. This study was aimed to evaluate relationships among the physicochemical parameters in the bottom water of Masan bay and to examine environmental factors affecting to pollutions of seawater by factor analysis. 'rife factor loading, 1 is showed higher increasing inclination after 1989 year in station 1. The variance of pollutant materials is showed 43.7% in which the coastal inflow water is indicated external loadings(factor 1 : NO3--N, TN, factor 4 : SiO2-Si) corresponded to domestic sewage, industrial wastewater, and earth-sands in the bottom water of Masan bay And the internal loadings(factor 2 : SS, salinity, factor 3 . W.T., DO) are explained 33.8%'corresponded the phenomena of sedimentary layer and oxygen concentration. Therefore, The external loadings are explained by the higher factor pollutantal variance in Masan bay.

  • PDF