• Title/Summary/Keyword: industrial accident rate

Search Result 259, Processing Time 0.026 seconds

An Epidemiological Observation of Fire Accident in Korea (화재사고(火災事故)(WHO-E 916)에 관(關)한 역학적관찰(疫學的觀察))

  • Lee, Chong-Dae;Han, Seong-Un;Bin, Soon-Duk;Chu, In-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.1 no.1
    • /
    • pp.43-49
    • /
    • 1968
  • Epidemiological and statistical observations were made of fire hazards that occurred during the past 18 years, 1948 to 1965. Injury and mortality rates for all ages were computed chronologically. For the years of 1955, 1961 and 1965, all fire accidents were epidemiologically analysed to draw characteristic patterns in relation to the seasonal and 24 hour distribution, causes and sites of accidents etc.. Fire hazards observed herein are the categorys E 916 of the International Classification of Causes of Death, 1955, and includes all accidents caused by fire and explosion of combustible materials. The following conclusion was made: 1. The average number of annual deaths due to fire was 183 and the number of the in jured due to the same cause was 335. The mortality rate per 100,000 population was 0.8 and the ratio of injuries per death was 1.83. 2. The casually rate including both the dead and injured was 5.0 per 100,000 in Seoul, the highest among the provinces and followed by 3.4 in Cheju -Do, 2.1 in Kangwon-Do, 1.7 in Kyunggi-Do accordingly. The other provinces had a range of 0.6 to 1.2. 3. The monthly distribution of fro accidents showed that the winter months, December through February, had more frequent accidents, while the summer season, June through August had less. The 24 hour distribution of accidents showed more cases from 12:00 to 18:00 and less from 4:00 to 10:00 hours. 4. The per cent distribution of causes of accidents showed; 90.0% for careless, 10.0% for arson. The cause of carelessness was further breakdown into; 15.0% for kitchen fire places, 13.8% for fire playing, 9,4% for electrical heating and wires, 8.3% for fuels, 6.3% for matches, 5.2% for ash dumps and the remaining for others. 5. The accidents as classified by place revealed that 56.8% of the total occurred at the common dwelling houses, 11.3 at various industrial workshops, 9.3% at the street shops and the remaining at the miscellaneous places.

  • PDF

A Study on the Improvement of Safety and Health Activities in the Construction Contractor (Public Institutions) (건설공사 발주처(공공기관) 안전보건활동 수준향상에 관한 연구)

  • Ji-Hwan Moon
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.624-633
    • /
    • 2023
  • Purpose: It Vas intended to identify problems and derive improvement plans by grasping the current status of safety management of public institutions among construction Vork orders. Method: By comparing the disaster status of public institutions compared to the total construction Vork, the analysis Vas conducted based on the results of the evaluation of the level of safety activities of public institutions Vith a high disaster rate and the results of actual consulting. Result: As a result of comparing and analyzing the current status of safety management of public institutions, the current status and problems of safety management in public institutions Vith a high accident rate Vere similarly discovered. Safety management organizations, document management systems, safety management systems, and risk assessment activities are operated Vithout reflecting the size and characteristics of the organization, so improvement in the relevant field is needed. Conclusion: Safety-related professionals and organizations should be formed according to the size of construction orders, and responsibility and authority should be clearly assigned. Since risk assessment is conducted formally to prepare a safety and health ledger, it is necessary to derive risk factors to prevent safety accidents for the actual construction. It is expected that the level of safety activities can be improved if it is improved by reflecting the size and characteristics of public institutions.

Residue levels of phthalic acid esters (PAEs) and diethylhexyl adipate(DEHA) in various industrial wastewaters (업종별 산업폐수 중 프탈산에스테르와 디에틸헥실아디페이트의 잔류수준)

  • Kim, Hyesung;Park, Sangah;Lee, Hyeri;Lee, Jinseon;Lee, Suyeong;Kim, Jaehoon;Im, Jongkwon;Choi, Jongwoo;Lee, Wonseok
    • Analytical Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.57-64
    • /
    • 2016
  • Many phthalic acid esters (PAEs), including DMP, DEP, DBP, BBP, and DEHP, as well as DEHA are widely used as plasticizers in plastics. An analytical method was developed and used to analyze these compounds at 41 industrial facilities. The coefficient of determination (R2) for each constructed curve was higher than 0.98. The method detection limit (MDL) values were 0.4–0.7 μg/L for PAEs and 0.6 μg/L for DEHA. In addition, the recovery rate was shown to be 77.0–92.3%, while the relative standard deviation was shown to be in the range of 5.8-10.5%. DMP (n = 3), DEP (n = 2), DBP (n = 2), BBP (n = 2), and DEHA (n = 3) were detected in the range of 2.2-11.1% in the influent. DEHP was a predominant compound and was detected at > MDL in both the influent (n = 16, 35.6%) and the effluent (n = 4, 10.0%) at a high removal efficiency (92–100%). The highest levels of residue in industrial wastewater influent were 137.4 μg/L of DEHP at plastic products manufacturing facility, 12.5 μg/L of DEHA at a chemical manufacturing facility, and 14.0 μg/L of DEP at an electronics facility. The highest concentration of effluent was 12.5 μg/L of DEHP at a chemical manufacturing facility, which indicated that the effluent was below the allowable concentration (800 μg/L). Therefore, the levels of PAEs and DEHA that are discharged into nearby streams could not influence the health of the ecosystem.

Analysis of Waterborne Automotive Refinish Paint for Investigating Insurance Fraud (차량 보수도장 보험사기 규명을 위한 수용성 페인트 성분분석)

  • Lee, Joon-Bae;Lee, Cheon-Ho;Ryu, Seung-Jin;Gong, Bokyoung;Kwon, O-Seong;Kim, Myung-Duck;Kim, Nam Yee;Paeng, Ki Jung
    • Applied Chemistry for Engineering
    • /
    • v.28 no.4
    • /
    • pp.490-494
    • /
    • 2017
  • With increasing the number of vehicles, the accident rate also goes up and the damaged vehicles should be painted as a final repair process. At the painting stage the solvent-based paint causes environmental problems. To overcome these problems waterborne refinish paint is frequently used recently. However, for waterborne refinish, the costs of insurance coverage are too expensive, and insurance reimbursement costs could be burdensome. Because of the high price of aquatic paint treatment, the service shop might charge the malicious service price. In this study, the surfactant of Surfynol 104, which is the component in the paint, was used as an indicator whether the vehicle was painted with waterborne paint. The specimen was quantitatively analyzed to contain 0.38% of the surfactant through the standard addition method with isotope substituted internal standard (IS) of fluranthene-d10 by curie point pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS).

Development of Location/Safety Tracking System for Construction Site Workers by Using MEMS Sensors (MEMS 센서를 활용한 건설현장 작업자 위치/안전 정보 추적 시스템 개발)

  • Kim, Jin-Young;Ahn, Sung-Soo;Kang, Joon-Hee
    • 전자공학회논문지 IE
    • /
    • v.49 no.1
    • /
    • pp.12-17
    • /
    • 2012
  • Fast development of ubiquitous technology prompted the broadening of the related application area. Application of ubiquitous techniques and system into the construction sites may give us many benefits. There are always a lot of hazard situations in construction sites, and the falling is known to have the high accident rate. To prevent the falling, there has been a lot of efforts including safety education and use of safety gears. In this study, we designed, fabricated and tested a system that can monitor the worker's safety and location informations in real time by using the wireless technology of TOA and RSSI. We used ATmegal28 that is popular in the industrial equipments as MCU and NanoPan 5357 module from Nanotron and CC2500 chipset from TI for radio circuits. We also used 3-axis accelerometer and pressure MEMS sensors to obtain the environmental information, and therefore to aquire the informations of the worker's movement and altitude. We used Labview software from National Instrument to monitor and control the system. We developed the system to send the warning alarms to the server operator and the workers when the workers in the danger zone did not wear the safety hook.

Method for Preventing Asphyxiation Accidents by a CO2 Extinguishing System on a Ship (선박 내 CO2 소화설비에 의한 질식사고 방지 기법)

  • Ha, Yeon-Chul;Seo, Jung-Kwan;Hwang, Jun-Ho;Im, Kichang;Ryu, Sang-Hoon
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.57-64
    • /
    • 2015
  • Carbon dioxide extinguishing systems are broadly used for onshore and offshore fire accidents because of excellent performance and low cost. However, there is risk with carbon dioxide systems, which have caused many injuries and deaths by suffocation associated with industrial and marine fire protection applications. In this study, a numerical analysis was performed to predict the fire suppression characteristics of a carbon dioxide system in the compressor room of ships. A double protection safety system is suggested to prevent suffocation accidents from carbon dioxide extinguishing systems. Four scenarios were selected to study the variation of the heat release rate, maximum temperature, a $CO_2$ and $O_2$ mole fraction, and fire suppression characteristics with the carbon dioxide system. The importance of proper design is suggested for a ventilation system in the compressor room of ships.

Thermal Insulation Effect of Inflatable Life Vest on the Drowned Individual estimated by Numerical Analysis (익수자 체온 저하에 미치는 팽창식 구명동의의 단열효과 수치 분석)

  • Kim, Sung Chan;Lee, Kyung Hoon;Hwang, Se Yun;Lee, Jin Sung;Lee, Jang Hyun
    • Journal of Navigation and Port Research
    • /
    • v.39 no.4
    • /
    • pp.285-291
    • /
    • 2015
  • Exposure to cold sea water can be life-threatening to the drowned individual. Although appropriate life jacket can be usually be provided for the buoyance at the drowning accident, heat loss can make the drowned individual experience the hypothermia. Inflatable life jackets filled with inflatable air pocket can increase the thermal protection as well as the buoyancy force. Because it is important to know how the human body behaves unde the different life jacket, present study compares the thermal insulation capacity of solid type life jacket with that of inflatable life jacket. In order to represent the insulation capacity of life jacket, thermal resistance is estimated based on the assumption of steady-state. Also, a transient three-dimensional thermal distribution of the thigh is analyzed by using finite element method implementing the Pennes bioheat equation. The finite element model is a segmental, multi-layered representation of the body section which considers the heat conduction within tissue, bone, fat and local blood flow rate.

A study on the condition assessment of large diameter water valves using non-destructive technologies (비파괴 기술을 이용한 대구경 수도용 밸브의 상태평가에 관한 연구)

  • Ho-Min Lee;Hyun-yong Choi;Suwan Park;Tae-min Oh;Chae-Min Kim;Cheol-Ho Bae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.4
    • /
    • pp.215-229
    • /
    • 2023
  • In this study, non-destructive technologies that can be applied to evaluate the integrity of valve materials, safety against internal pressure caused by corrosion, and the blocking function of large-diameter water valves during operation without requiring specimen collection or manpower entering the inside of the valve were tested to assess the reliability of the technologies and their suitability for field application. The results showed that the condition of the graphite structure inside the valve body can be evaluated directly through the optical microscope in the field without specimen collection for large-diameter water butterfly valves, and the depth of corrosion inside the valve body can be determined by array ultrasound and the tensile strength can be measured by instrumented indentation test. The reliability of each of these non-destructive techniques is high, and they can be widely used to evaluate the condition of steel or cast iron pipes that are significantly smaller in thickness than valves. Evaluation of blocking function of the valves with mixed gas showed that it can be detected even when a very low flow rate of mixed gas passes through the disk along with the water flow. Finally, as a result of evaluating the field applicability of non-destructive technologies for three old butterfly valves installed in the US industrial water pipeline, it was found that it is possible to check the material and determine the suitability of large-diameter water valves without taking samples, and to determine the corrosion state and mechanical strength. In addition, it was possible to evaluate safety through the measurement results, and it is judged that the evaluation of the blocking function using mixed gas will help strengthen preventive response in the event of an accident.

A Look at the Need for a Crafts program of Developmental Disabilities (발달장애의 수예공작 프로그램 필요성에 관한 고찰)

  • Kim, Nam-Soon;Kim, Dong-Hyun;Kim, Hee-Jung
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.1 no.1
    • /
    • pp.79-89
    • /
    • 2011
  • The number of the disabled person had been increased for the industrial accident and the environmental pollution. Especially, developmental disability has the high prevalence rate between 5% and 10% of the whole children. The children with a developmental disability can be treated by the physical therapy, the occupational therapy, the psychology therapy, speech therapy, and art therapy. Visual preception which is function to recognize the external environment through the optic organ could be related to most behaviors on the everyday life. But because the children with disability could not develop the visual-preception enough, they came to have difficulties in executing daily life project. For this reason, it is most important to understand the estimation and the cure on the visual-preception in the pediatric occupational therapy. To improve the visual-preception power, we have many kind of methods including sensory integration, training program for the visual-perception and art-craft program. Particularly, the art-craft which is the representative activity for making something by hands, can be applied to anyone. As the study on the brain has been activated, it was proved that handicraft actives could have an good effect on the brain function and using brain. When the fine motor exercise and more delicate and accurate motion were carried, these motions need the essential help of the visual-perception. So it could be expected that using the repetitive hand function by art-craft makes the brain function improve, when a activity that needs a fine motor exercise and more delicate, accurate motion was carried, It also indicates that the art-craft program has a clear treatment value. Though the intervention between visual-perception development and visual-perception disability have a majority in the field of occupational therapy, there is a few study yet. Therefore, this study tried to look back on the necessity of applying the art-craft program to the children with disability as the prestudy for preliminary validity of the master's thesis.

  • PDF