• Title/Summary/Keyword: induction technique

Search Result 582, Processing Time 0.026 seconds

Sensorless Speed Control of Induction Motor by Neural Network (신경회로망을 이용한 유도전동기의 센서리스 속도제어)

  • 김종수;김덕기;오세진;이성근;유희한;김성환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.6
    • /
    • pp.695-704
    • /
    • 2002
  • Generally, induction motor controller requires rotor speed sensor for commutation and current control, but it increases cost and size of the motor. So in these days, various researches including speed sensorless vector control have been reported and some of them have been put to practical use. In this paper a new speed estimation method using neural networks is proposed. The optimal neural network structure was tracked down by trial and error, and it was found that the 8-16-1 neural network has given correct results for the instantaneous rotor speed. Supervised learning methods, through which the neural network is trained to learn the input/output pattern presented, are typically used. The back-propagation technique is used to adjust the neural network weights during training. The rotor speed is calculated by weights and eight inputs to the neural network. Also, the proposed method has advantages such as the independency on machine parameters, the insensitivity to the load condition, and the stability in the low speed operation.

Chattering Reduction of Variable Structure Controller for Position System of Induction Motor (유도전동기의 위치제어 시스템을 위한 가변구조제어기의 떨림저감)

  • Kim, Young-Jo;Kim, Hyun-Jung
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.2
    • /
    • pp.39-47
    • /
    • 1998
  • It has been known that variable structure control(VSC) has theoretically powerful control technique of providing fast response, no overshoot, and very robust control with respect to system parameter variations and disturbances. However, the technique has not become more widely extended in the industrial circles because chattering phenomenon which may excite high-frequency unmodelled plant dynamics and damage to system components exists. In this paper, a modified variable structure control(MVSC) is developed to alleviate these problems which are applied to the position control of induction motor. While the conventional VSC makes the structure of the system change with high-frequency switching on the center of the one switching surface, in the MVSC two switching surface are used to establish a sliding sector. The structure of the system will be changed with low-frequency switching. Therefore, the proposed algorithm has the properties of reducing chattering, retaining the benefits achieved in the conventional VSC, and working even under the influences of parameter variations. Experimental results show the effectiveness of the control strategy proposed here for the position control of induction motor.

  • PDF

Induction of PCB degradative pathway by plant terpenoids as growth substrates or inducers

  • Jeong, Gyeong-Ja;Kim, Eung-Bin;So, Jae-Seong;Go, Seong-Cheol
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.489-492
    • /
    • 2000
  • The eventual goal of this study is to elucidate roles of plant terpenoids (e.g., cymene, limonene and others) as natural substrates in the cometabolic biodegradation of PCBs and to develop an effective PCB bioremediation technology. The aim of this study was to examine how plant terpenoids, as natural substrates or inducers would affect the biodegradation of PCB congeners. Various PCB degraders that could grow on biphenyl and several terpenoids were tested for their PCB degradation capabilities. The PCB congener degradation activities were first monitored through resting cell assay technique that could detect degradation products of the substrate. The congener removal was also confirmed by concommitant GC analysis. The PCB degraders, Pseudononas sp. P166 and Caynebacterium sp. T104 were found to grow on both biphenyl and terpenoids ((S)-(-) limonene, p-cymene and ${\alpha}-terpinene$) whereas Arthrobacter B1B could not grow on the terpenoids as a sole carbon source. The strain B1B grown on biphenyl showed a good degradation activity for 4,4'-dichlorobiphenyl (DCBp) while strains P166 and T104 gave about 25% of B1B activity. Induction of degradation by cymene, limonene and terpine was hardly detected by the resting cell assay technique. This appeared to be due to relatively lower induction effect of these terpenoids compared with biphenyl. However, a subsequent GC analysis showed that the congener could be removed up to 30% by the resting cells of T104 grown on the terpenoids. This indicates that terpenoids, widely distributed in nature, could be utilized as both growth and/or inducer substrate for PCB biodegradation.

  • PDF

Bearing Faults Identification of an Induction Motor using Acoustic Emission Signals and Histogram Modeling (음향 방출 신호와 히스토그램 모델링을 이용한 유도전동기의 베어링 결함 검출)

  • Jang, Won-Chul;Seo, Jun-Sang;Kim, Jong-Myon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.11
    • /
    • pp.17-24
    • /
    • 2014
  • This paper proposes a fault detection method for low-speed rolling element bearings of an induction motor using acoustic emission signals and histogram modeling. The proposed method performs envelop modeling of the histogram of normalized fault signals. It then extracts and selects significant features of each fault using partial autocorrelation coefficients and distance evaluation technique, respectively. Finally, using the extracted features as inputs, the support vector regression (SVR) classifies bearing's inner, outer, and roller faults. To obtain optimal classification performance, we evaluate the proposed method with varying an adjustable parameter of the Gaussian radial basis function of SVR from 0.01 to 1.0 and the number of features from 2 to 150. Experimental results show that the proposed fault identification method using 0.64-0.65 of the adjustable parameter and 75 features achieves 91% in classification performance and outperforms conventional fault diagnosis methods as well.

Fault Diagnosis of Voltage-Fed Inverters Using Pattern Recognition Techniques for Induction Motor Drive (패턴인식 기법을 이용한 유도전동기 구동용 전압형 인버터의 고장진단)

  • Park, Jang-Hwan;Park, Sung-Moo;Lee, Dae-Jong;Kim, Dong-Hwa;Chun, Myung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.75-84
    • /
    • 2005
  • Since an unexpected fault of induction motor drive systems can cause serious troubles in many industrial applications, which the technique is required to diagnose faults of a voltage-fed PWM inverter for induction motor drives. The considered fault types are rectifier diodes, switching devices and input terminals with open-circuit faults, and the signal for diagnosis is derived from motor currents. The magnitude of dq-current trajectory is used for the feature extraction of a fault and PCA LDA are applied to diagnose. Also, we show results with respect to the execution time because of the possibility to use that a diagnosis software is embedded in the controllers of medium and small size induction motors drive for real-time diagnosis. After we performed various simulations for the fault diagnosis of the inverter, the usefulness of proposed algerian was verified.

Industrial Application of Embryo Transfer in Korea (수정란이식의 산업화 방안)

  • 정길생
    • Korean Journal of Animal Reproduction
    • /
    • v.7 no.2
    • /
    • pp.41-52
    • /
    • 1983
  • Animal in dustry in Korea urgently needs the domestic introduction and the industrial a, pp.ication of embryo transfer technique. Namely, this technique can be utilized effectively, as means of the improvement of livestocks, as means of the increase of meat production, as means of substitute for the livestock import, and dissemination of new breed. However, as this technique avaliable in our country is remaining initial stage, we can not make use of the technique industrially unless we make much improvement as follows; induction of superovulation, non-surgical recovery of embryos, synchronization between the estrus such cycles of donor and recipient, non-surgical transfer of embryos, etc. Simultaneously, the basic studies such as harvesting oocytes from ovary, in vitro culture of oocytes, in vitro capacitation of spermatozoa, cloning by culture of blastomeres and transfer of nuclei, sexing embryo, etc. should not be neglected in order to make the technique of embryo transfer more simple and convenient. For the success of these studies, universities, national and public institutes, large scale cattle farms, and small scale cattle farms should cooperate each other. For instance, universities undertake basic researches, and the national and public institutes a, pp.y the results of the researches to animal industry along with cooperation by large scale cattle farms. By the help of the cooperative organizations, the technique relevant to our environment and farm condition may be able to be finalized, and to be a, pp.ied to samll scale cattle farm. Consequently, being served to stimulate animal productivity, this technique can be contributed to the development of livestock industry in Korea.

  • PDF

Study on Spawning Induction and Larvae Breeding of the Hard Clam, Meretrix petechiails (Lamarck) (말백합, Meretrix petechiails (Lamarck) 의 산란유발 및 유생사육에 관한 연구)

  • Kim, Byeong-Hak;Moon, Tae-Seok;Park, Ki-Yeol;Jo, Pil-Gue;Kim, Min-Chul
    • The Korean Journal of Malacology
    • /
    • v.26 no.2
    • /
    • pp.151-156
    • /
    • 2010
  • For industrialization of the hard clams, Meretrix petechiails (Lamarck), spawning was induced per spawning induction technique in the artificial maturation group administered of parent maturation control and the natural maturation group of which parents were transported for artificial spawning per time period. Then, fertilization rates, hatching rates and D-shaped larva development rates were investigated. In addition, growth and survival rates of larvae were investigated per larva breeding technique. The results of spawning induction by exposure in the artificial maturation group indicated that response rates were relatively higher at 23% and 32% respectively at the 4th hour and the 8th hour of exposure. In terms of water temperature increase, responses began only when the temperature reached $28^{\circ}C$ or higher. In the experiment group administered with both exposure and water temperature increase techniques, response rate was found to be 45% or higher at the 4th hour of exposure and the temperature of $28^{\circ}C$. At the temperatures of 29, 30 and $31^{\circ}C$, significant differences were not observed. Therefore, it was indicated that the response rates of parent hard clams were higher toward water temperature increase than exposure time. As for spawning induction per time period of the transported parent group, response rate and D-shaped larva development rate were the highest at 67.6% and 96% respectively on August 6, 2009. In terms of water temperatures during larva breeding experiment, growth was faster as water temperature was higher. In addition, growth and survival rates were relatively higher at the salinity of 25. In terms of stocking density, growth and survival rates were relatively higher at 5 inds./mL.

Development of the Automation System for a fish Pump(I) -Adjustable Speed Control of a Fish Pump Using a Simplified PWM Inverter- (피쉬펌프의 자동화 시스템 개발(I) -간이화 PWM 인버터를 이용한 피쉬펌프의 가변속 제어-)

  • 정석권
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.328-334
    • /
    • 1999
  • A fish pump makes very important roles in an automation system of an aquaculture farm, thus it has been used widely in order to transfer fishes from one place to the other place automatically. In spite of its significant roles, the efforts for developing performance and promoting efficiency of the fish pump are not sufficient yet. In this paper, a method which makes the fish pump automation system is suggested. Automation of the fish pump can be accomplished by using variable voltage and variable frequency inverter system including induction motors. Especially, very simple logic to generate Pulse width Modulation(PWM) wave to control induction motor efficiently and three steps speed control method to regulate liquid quantity of the fish pump simply are suggested. Owing to the simplifies speed control and PWM wave generation technique, a cheaper microprocessor, 80C196KC, than a digital signal Processor(DSP) can be used to operate control algorithm in induction motor systems for real time control Also, a new idea of remote control for the simplifies novel inverter system by Programmable logic Controller(PLC) without special output unit, digital to analog converter(D/A), is suggested in this paper. Consequently the function of reliability, availability and serviceability of the fish pump system are developed. It will be expected to contribute expanding of application of the fish pump in aquaculture farms because the system can reduce energy consumption and some difficulties according to manual operation prominently.

  • PDF

Torque Ripple Minimization for Induction Motor Driven by a Photovoltaic Inverter

  • Atia, Yousry
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.679-690
    • /
    • 2009
  • The paper presents a new photovoltaic inverter for stand-alone induction motor application. The proposed system is composed of two stages. First stage is for the photovoltaic dc power feeding and second stage is dedicated to the motor-inverter subsystem and control technique. A direct torque control (DTC) with a novel switching strategy for motor torque ripple minimization is introduced. The novel DTC strategy is based on selecting a suitable voltage vector group for motor torque ripple minimization. A three-level voltage source inverter (VSI) is used instead of a two level inverter because the first has more available vectors and lower ripples in the output current and flux than the second, thus it has lower torque ripples. The photovoltaic array and battery bank are sized and the configuration is indicated based on sun-hour methodology. Simulation results show a comparison between three systems; two level VSI with conventional DTC strategy, three level VSI with conventional DTC, and the proposed system that has a novel DTC switching strategy applied to three level VSI. The results show that the proposed system has lower ripples in the current, flux and torque of the motor.

PID Controller Tuning using Co-Efficient Diagram method for Indirect Vector Controlled Drive

  • Durgasukumar, G.;Rama Subba Redddy, T.;Pakkiraiah, B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1821-1834
    • /
    • 2017
  • Medium voltage control applications due to obtain better output voltage and reduced electro-magnetic interference multi level inverter is used. In closed loop control with inverter, the PI controller does not operate satisfactorily when the operating point changes. This paper presents the performance of Co-Efficient diagram PI controller based indirect vector controlled induction motor drive fed from three-level inverter under different operating conditions (dynamic and steady state). The proposed Co-Efficient diagram PI controller based three level inverter significantly reduces the torque ripple compared to that of conventional PI controller. The performance of the indirect vector controlled induction motor drive has been simulated at different operating conditions. For three-level inverter control, a simplified space vector modulation technique is implemented, which reduces the coordinate transformations complications in the algorithms. The performance parameters, torque ripple contents and THD of induction motor drive with three-level inverter is compared under different operating conditions using CDM-PI and conventional PI controllers.