• Title/Summary/Keyword: induction program

Search Result 309, Processing Time 0.026 seconds

Clinical Evaluation of Endogenous LH Surge in Superovulation Cycle for I.V.F. (체외수정을 위한 과배란유도 주기에서 내인성 LH Surge의 발생에 관한 연구)

  • Kim, Tak;Kim, Sun-Haeng;Ku, Pyong-Sham;Joo, Kap-Soon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.16 no.1
    • /
    • pp.93-101
    • /
    • 1989
  • 71 cycles of 67 women were treated for superovulation induction in our IVF & ET program from May to September in 1988. Endogenous LH surges were occurred in 21 cycles out of 71 cycles. And then, we selected 50 cycles without endogenous LH surge treated in the same period as control group. We compared egg recovery rate, egg maturity, fertilization rate, cleavage rate and pregnancy rate of study group with those of control group. We were able to detect more than 90% of endogenous LH surge by commencing daily LH monitoring on MCD 9. The egg recovery rate, egg maturity, fertilization rate, and pregnancy rate of the study group were not statistically different from those of the control group. Significantly lower cleavage rate was seen in the study group compared with that of control group. Above results suggested that the cycles with endogenous LH surge do not have to be abandoned and can be treated continuously to achieve successful pregnancy.

  • PDF

A Study of Using Optimal Hysteresis Band Amplitude for Direct Torque Control of Induction Motor (유도전동기 직접토크제어의 히스테리시스 밴드 크기의 최적화에 관한 연구)

  • Jeong B.H.;Kim S.K.;Park J.K.;Oh G.K.;Cho G.B.;Baek H.L.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.812-815
    • /
    • 2003
  • Most of all, DTC drive is very simple in its implementation because it needs only two hysteresis comparator and switching vector table for both flux and torque control. The switching strategy of a conventional direct torque control scheme which is based on hysteresis comparator results in a variable switching frequency which depends on the speed, flux, stator voltage and the hysteresis of the comparator. The amplitude of hysteresis band greatly influences on the drive performance such as flux and torque ripple and inverter switching frequency. In this paper the influence of the amplitudes of flux and torque hysteresis bands and sampling time of control program on the torque and flux ripples are investigated. Simulation results confirm the superiority of the DTC under the proposed method over the conventional DTC.

  • PDF

Development of Traction Unit for 2-motor Driven Electric Vehicle

  • Park, Jung-Woo;Koo, Dae-Hyun;Kim, Jong-Moo;Kim, Heung-Geun
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.950-954
    • /
    • 1998
  • This paper describes a development of traction unit for 2-motor driven electric vehicle (EV). The traction unit is consisted with an interior permanent magnet synchronous motor (IPMSM), a reduction gear and an inverter for electric vehicle that is driven by 2 motors without differential gear. For traction unit, prototype IPMSM and inverter have been developed. The IPMSM was designed by CAD program that was developed with both equivalent circuit method and FEM. Also the inverter was developed to drive 2 motors with 6 legs IGBT switches in a control board. The vector control algorithm was implemented with maximum torque control method in the constant torque region and field weakening control method in the constant power region considering inverter capacity. To verify that the traction unit is more high efficiency and has more high power density than a traction unit with induction motor with the same power, we would like to show the results about the design and analysis of the IPMSM and the experiment results about the traction unit.

  • PDF

Diarylbutane-type Lignans from Myristica fragrans (Nutmeg) show the Cytotoxicity against Breast Cancer Cells through Activation of AMP-activated Protein Kinase

  • Le, Thi Van Thu;Nguyen, Phi Hung;Choi, Hong Seok;Yang, Jun-Li;Kang, Keon Wook;Ahn, Sang-Gun;Oh, Won Keun
    • Natural Product Sciences
    • /
    • v.23 no.1
    • /
    • pp.21-28
    • /
    • 2017
  • In our program to search for new AMP-activated protein kinase (AMPK) activators from plants that exert potential anticancer property, we found that an EtOAc extract of Myristica fragrans (nutmeg) activated AMPK enzyme in human breast cancer MCF-7 cells. Two major diarylbutane-type lignans, macelignan and meso-dihydroguaiaretic acid (MDGA), were isolated as active principles from this extract. Treatment of breast cancer cells with two compounds induced cellular apoptosis, evidenced by cleavage of poly-(ADP-ribose) polymerase (PARP) and Ser 15 phosphorylation of p53. Moreover, macelignan and MDGA significantly inhibited the colony formation of MCF-7 breast cancer cells on soft agar. Intraperitoneal injection of macelignan and MDGA (20 mg/kg) suppressed the tumor growth of 4T1 mammary cancer cells. These results indicate that the chemopreventive effects of two major diarylbutane-type lignans from Myristica fragrans (nutmeg) may be associated with induction of apoptosis presumably through AMPK activation.

Development of Transcutaneous Energy Transmission System for Medical Instrument (의료용 무선 에너지 전달 장치의 개발)

  • 안재목;이동준
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.447-456
    • /
    • 1995
  • As a part of electro-mechanical totally implantable artificial heart (TIAH) program, a transcut- aneous energy transmission system has been developed. By mutual magnetic induction between the first coil on the skin and the subcutaneously implanted second coil, the system transfers elctrical power through the skin. This research aimed at minimizing the size of the implanted part as well as maximizing the transfer efficiency. Using class I amplifier, we achieved above 75% power transfer efficiency at average 40W power transfer level which is required for normal TIAH operation. In vivo performance of the developed system and bio-compatibility of the material used in Implanted parts were evaluated through animal experiments.

  • PDF

Analysis of Flicker Mitigation Effects using IEC Digital Flickermeter based on Matlab/Simulink Simulation (Matlab/Simulink 기반의 IEC 플리커미터를 이용한 플리커 저감효과 모의에 대한 연구)

  • Jung, Jae-Ahn;Cho, Soo-Hwan;Kwon, Sae-Hyuk;Jang, Gil-Soo;Kang, Moon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.232-238
    • /
    • 2009
  • Flicker, also known as voltage fluctuation, is a newest problem of power quality issues, because it is caused by nonlinear loads such as electrical arc furnace and large-scale induction motor, which are country-widely used as the heavy industries of a country develop. An international standard, International Electrotechnical Commission (IEC) 61000-4-15, was published in 1997 and revised in 2003. With increasing concerns about flicker, its mitigation methods have been also studied. General countermeasures for flicker are divided into three categories: a) enhancing the capacity of supplying system, b) Series elements including series reactor and series capacitor and c) power electronic devices including static VAR compensator (SVC) and static synchronous compensator (STATCOM). This paper introduces how to mitigate the voltage flicker at the point of common coupling (PCC) and presents how to simulate and compare the flicker alleviating effects by each mitigation method, using IEC flickermeter based on the Matlab/Simulink program.

Use of Web-Based Evidence-based Clinical Practice Guidelines for Patients following Gastrectomy: Effects on Body Temperature, Shivering, Perceived Thermal Comfort, and Satisfaction with Temperature Management (웹기반 체온 관리 근거중심 간호실무 가이드라인이 위절제술 환자의 체온, 전율, 체온 불편감, 체온 관리 만족도에 미치는 효과)

  • Hong, Sung-Jung;Lee, Eunjoo
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.21 no.2
    • /
    • pp.112-122
    • /
    • 2014
  • Purpose: The purpose of this study was to examine the effects on body temperature, shivering, and perceived thermal comfort of web-based evidence-based practice guideline for patients undergoing gastrectomy. Methods: Eighty patients scheduled for gastrectomy were recruited and assigned to the control or experimental group by sequential order. Before collecting data from the experimental group, a systematic educational program on evidence-based guidelines was provided to the nurses as well anesthesiologists. Data were analyzed using t-test and repeated measured ANOVA. Results: The experimental group showed higher body temperature from the induction of anesthesia until four hours after surgery compared to the control group. In addition, the levels of thermal comfort as well as satisfaction with thermal management were significantly higher in the experiment group. Conclusion: Use of evidence-based guidelines was effective in maintaining body temperature, lowering sensitivity to shivering, and promoting perceived thermal comfort. Therefore, adoption of evidence-based interventions in nursing practice is recommended.

Study on Impact of Wind Power in Grid Frequency Quality of Stand-alone Microgrid (독립형 마이크로그리드내 풍력발전출력이 주파수 품질에 미치는 영향 분석)

  • Huh, Jae-Sun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.79-85
    • /
    • 2016
  • This paper analyzed the influence of wind power fluctuations in grid frequency of a stand-alone microgrid that is hybrid generation system with diesel generator, wind turbine, and Battery Energy Storage System (BESS). The existing island area power system consists of only diesel generators. So the grid frequency can be controllable from load change. But hybrid generation system with Renewable Energy Sources (RES) such as wind energy that has the intermittent output can bring power quality problems. BESS is one of the ways to improve the intermittent output of the RES. In this paper, we analyzed the role of BESS in a stand-alone microgrid. We designed a modelling of wind power system with squirrel-cage induction generator, diesel power system with synchronous generator, and BESS using transient analysis program PSCAD/EMTDC. And we analyzed the variation of the grid frequency according to the output of BESS.

A study on DSP based power analyzing and control system by analysis of 3-dimensional space current co-ordinates (3차원 전류좌표계 해석법에 의한 DSP 전력분석 제어장치에 관한 연구)

  • 임영철;정영국;나석환;최찬학;장영학;양승학
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.543-552
    • /
    • 1996
  • The goal of this paper is to developed a DSP based power analyzing and control system by 3-Dimensional (3-D) space current co-ordinates. A developed system is made up of 486-PC and DSP (Digital Signal Processor) board, Active Power Filter, Non-linear thyristor load, and Power analyzing and control program for Windows. Power is analyzed using signal processing techniques based on the correlation between voltage and current waveforms. Since power analysis algorithm is performed by DSP, power analysis is achieved in real-time even under highly dynamic nonlinear loading conditions. Combining control algorithm with power analysis algorithm is performed by DSP, power analysis is achieved in real-time even under highly dynamic nonlinear loading conditions. Combining control algorithm with power analysis algorithm, flexibility of the proposed system which has both power analysis mode and control mode, is greatly enhanced. Non-active power generated while speed of induction motor is controlled by modulating firing angle of thyristor converter, is compensated by Active Power Filter for verifying a developed system. Power analysis results, before/after compensation, are numerically obtained and evaluated. From these results, various graphic screens for time/frequency/3-D current co-ordinate system are displayed on PC. By real-time analysis of power using a developed system, power quality is evaluated, and compared with that of conventional current co-ordinate system. (author). refs., figs. tabs.

  • PDF

A Study on the Dynamic Voltage Stability Considering the Power System Security Control (계통(系統)의 안전성(安全性) 제어(制御)를 고려(考慮)한 동적(動的) 전압안정도(電壓安定度)에 관(關)한 연구(硏究))

  • Lee, Geun-Joon;Hwang, Jong-Young;Lee, Gil-Soon;Jeong, Tay-Ho;Kim, Keon-Jung;Kim, Yong-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.54-60
    • /
    • 1994
  • The cause of black out of Tokyo Power in 1987 has been identified as the voltage stability problem. After this event many researchers has been interested in voltage stability or voltage collapse phenomena. The voltage instability is different Com the transient stability in the sense of reactive power mismatch and the long duration time. In this study, we developed efficient tool for analyze and control the dynamic voltage instability. To analize specific condition of dynamic voltage stability, quasi-dynamic simulation method is developed. To provide proper mathmatical model for dynamic voltage stability, generator, SVC, OLTC, induction motor models are introducted. To provide specified dynamic voltage stability, the authors considered to use reactive loss function(${\partial}Q/{\partial}p_L$) as reactive power facility control index. This program was tested and identified its usefulness in real KEPCO system.

  • PDF