• 제목/요약/키워드: inducer

검색결과 619건 처리시간 0.021초

끝틈새가 터보펌프 인듀서의 성능에 미치는 영향 (Effect of Tip Clearance on the Performance of a Turbopump Inducer)

  • 홍순삼;김진선;최창호;김진한
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.558-563
    • /
    • 2004
  • Experiments were performed to see the effect of radial tip clearance on a turbopump inducer, which has two blades with inlet tip blade angle of 7.8 degree and tip solidity of 2.7. Hydraulic and cavitation tests were done for three cases of tip clearance ratio, that is, 0.026, 0.053, and 0.079. With increase in the tip clearance, inducer head and pressure on the inducer tip decreased. Attached cavitation and cavitation surge were found in the cavitation tests. In the attached cavitation one cell rotated at the same rotational speed as that of the inducer. Cavitation performance deteriorated with increase in the tip clearance. The level of casing vibration increased in the cavitation condition and the level was very high when the attached cavitation appeared.

  • PDF

끝틈새가 터보펌프 인듀서의 성능에 미치는 영향 (Effect of Tip Clearance on the Performance of a Turbopump Inducer)

  • 홍순삼;김진선;최창호;김진한
    • 한국유체기계학회 논문집
    • /
    • 제9권1호
    • /
    • pp.19-24
    • /
    • 2006
  • Experiments are carried out to investigate the effect of radial tip clearance on a turbopump inducer, which has two blades with inlet tip blade angle of 7.8 degree and tip solidity of 2.7. Hydraulic and cavitation tests are performed for three cases of tip clearance ratio, that is, 0.026, 0.053, and 0.079. With increase in the tip clearance, inducer head and pressure on the inducer tip decrease. Attached cavitation and cavitation surge are observed in the cavitation tests. In the attached cavitation one cell rotates at the same rotational speed as that of the inducer. Cavitation performance deteriorates with increase in the tip clearance. The level of casing vibration increases in the cavitation condition and the level is very high when the attached cavitation appears.

인듀서와 임펠러 축방향 간극이 터보펌프 성능에 미치는 영향 (Effects of axial distance between inducer and impeller on the performance of the turbopump)

  • 최창호;김대진;홍순삼;김진한
    • 한국유체기계학회 논문집
    • /
    • 제11권5호
    • /
    • pp.37-43
    • /
    • 2008
  • An inducer is employed in a modern rocket feed system because it allows a turbopump system to operate at a high speed with low inlet pressures so as to minimize the weight and the size of the system. Cavitation performance can be improved by installing an inducer to the pump, enabling to increase the operational speed of the pump. The main purpose of an inducer is to increase the static pressure prior to an impeller to enable the impeller to operate satisfactorily under cavitation environments. In the present study the effects of axial distance between the inducer and the impeller on the performance of the pump were studied using both experimental and computational methods. Two inducers with different axial length were used for the experiments and the pump performances were measured. The experimental results show that the suction performance decreases as the axial gap between the inducer and impeller is increased.

액체로켓용 터보펌프 인듀서/임펠러 상호작용에 대한 연구 (Numerical Studies on the Inducer/Impeller Interaction of a Liquid Rocket Engine Turbopump System)

  • 최창호;차봉준;양수석
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.33-40
    • /
    • 2002
  • The hydraulic performance analysis of a pump system composed of an inducer and impeller for the application on turbopumps has been performed using three-dimensional Wavier-Stokes equations. A simple mixing-plane method and a full interaction method are used to simulate inducer/impeller interactions. The computations adopting two methods show almost similar results due to the weak interaction between the inducer and impeller since the inducer outlet blade angle is rather small. But, because the inducer and the impeller are closely spaced near the shroud region at the interface, flow angles at the impeller inlet show different results between two methods. Thus, the full interaction method predicted about $2\%$ higher pump performance than the mixing-plane method. And the effects of prewhirl at the impeller inlet are also investigated. As the inlet flow angle is increased, the head rise and the efficiency are decreased. The computational results are compared with experimental ones. The computational results at the design point show good agreements with experimental data. But the computation was found to under-predict the head rise at high mass flow rates compared to the experiment, further study must be followed in terms of the computation and experiment.

  • PDF

액체로켓용 터보펌프 인듀서/임펠러 상호작용에 대한 연구 (Numerical Studies on the Inducer/Impeller Interaction Liquid Rocket Engine Turbopump)

  • 최창호;김진한
    • 한국유체기계학회 논문집
    • /
    • 제6권4호
    • /
    • pp.50-57
    • /
    • 2003
  • The hydraulic performance analysis of a turbopump with an inducer for a liquid rocket engine was performed using three-dimensional Navier-Stokes equations. A simple mixing-plane method and a full interaction method were used to simulate inducer/impeller interaction. Two methods show almost similar results due to the weak interaction between the inducer and impeller since the inducer outlet blade angle is lather small. But, when the inducer and the impeller are closely spaced near the shroud region, flow angles at the impeller inlet show different results between two methods. Thus, the full interaction method predicts about $2\%$ higher pump performance than the mixing-plane method. And the effects of prewhirl at the impeller inlet are also investigated. As the inlet flow angle is increased, the head rise and the efficiency are decreased. The computational results are compared with measured ones. The computational results at the design point show good agreements with experimental data, however under-predicts the head rise at high mass flow rates compared to the experiment.

터보펌프 인듀서의 비정상 캐비테이션에 관한 실험적 연구 (Experimental Study on the Unsteady Cavitation of Turbopump Inducer)

  • 홍순삼;김진선;최창호;김진한
    • 한국유체기계학회 논문집
    • /
    • 제8권1호
    • /
    • pp.23-29
    • /
    • 2005
  • Steady and unsteady cavitation characteristics of turbopump inducer were investigated in this paper. To investigate the effect of blade angle on the inducer performance, three inducers with inlet tip blade angle of $7.8^{\circ},\;7.0^{\circ},\;6.1^{\circ}$, respectively, were tested. For $7.8^{\circ},\;7.0^{\circ}$ inducers in the non-cavitating condition, head decreased linearly with flow rate, but head-flow rate curve had a dip at the flow coefficient ${\psi}=0.065$ for $6.1^{\circ}$ inducer. Attached cavitation and cavitation surge were found in the $7.8^{\circ},\;7.0^{\circ}$ inducers in the cavitation tests. During the attached cavitation one cell rotated at the same rotational speed as that of the inducer. The cavitation surge did not rotate and the oscillating frequency was $7{\sim}20\;Hz$. From the curve of the critical cavitation number versus flow rate, it was found that the steady cavitation performance of $6.1^{\circ}$ inducer was much lower than that of $7.8^{\circ},\;7.0^{\circ}$ inducers.

베어링 지지부가 터보펌프용 인듀서의 성능에 미치는 영향 (Effects of a Bearing Strut on the Performance of an Inducer for Turbopumps)

  • 최창호;노준구;김진선;홍순삼;김진한
    • 한국항공우주학회지
    • /
    • 제35권11호
    • /
    • pp.1022-1027
    • /
    • 2007
  • 베어링 지지부가 터보펌프용 인듀서의 성능에 미치는 영향에 대하여 실험적 및 계산적 연구가 수행되었다. 양정, 효율, 인듀서 슈라우드 압력 분포 등을 측정하였으며 유동해석 계산결과와 비교하였다. 유동해석결과는 실험결과와 비교하여 전체적으로 잘 일치하는 결과를 얻었다. 그러나 입구의 역류가 심해지는 저유량 작동조건에서는 계산값과 시험값이 다소의 차이를 보였다. 역류가 심해지는 저유량에서 베어링 지지부가 역류의 발달을 방해하여 인듀서의 수력성능을 향상시키는 것을 관찰하였으며, 베어링 지지부의 설치는 흡입성능에 큰 영향을 미치지 못함을 확인하였다.

흡수식 냉온수기내 용액펌프 Inducer의 Cavitation 불안정성에 대한 실험적 연구 (Experimental Study on Cavitation Instability of a Solution Pump Inducer in an Absorption Chiller-Heater)

  • 서민;이경훈;강신형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2434-2439
    • /
    • 2008
  • This paper was studied on the cavitation instability of a Solution Pump Inducer in an absorption chiller-heater. Inlet pressure of LiBr and rotational speed at nominal mode are 2,800 Pa and 3,500 rpm respectively. Due to the marginal operation of available NPSH, the cavitation performance of the inducer is critical for the stable operation without the deterioration of head performance. In the study, cavitation performance and its mode of instability was investigated experimentally. Water was used as the working fluid and the test inducer was scaled up as 1.75 times for detail measurements and flow visualization. Inlet pressure was controlled by a vacuum pump. This research focused on types of cavitation instability and phenomena to investigate the possibility of harmful damage due to cavitation instability. Casing wall pressure and instantaneous inlet pressure was measured to observe the unsteady flow characteristics. Through the visualization and spectrum analysis of pressure, the occurrence region and intensity of asymmetric cavitation and cavitation surge are analyzed in the test inducer.

  • PDF

터보펌프 인듀서의 비정상 캐비테이션에 관한 실험적 연구 (Experimental Study on the Unsteady Cavitation of Turbopump Inducer)

  • 홍순삼;김진선;최창호;김진한
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.333-339
    • /
    • 2003
  • Steady and unsteady cavitation characteristics of turbopump inducer were investigated in this paper. To see the effect of blade angle on the inducer performance, three inducers with inlet tip blade angle of $7.8^{\circ},\;7.0^{\circ},\;6.1^{\circ}$, respectively, were tested. For $7.8^{\circ},\;7.0^{\circ}$ inducers in the non-cavitating condition, head decreased linearly with flow rate, but head-flow rate curve had a dip at the flow coefficient ${\Phi}=0.065\;for\;6.1^{\circ}$ inducer. Rotating cavitation and cavitation surge were found in the $7.8^{\circ},\;7.0^{\circ}$ inducers in the cavitation tests. During the rotating cavitation one cell rotated at the same rotational speed as that of the inducer. The cavitation surge did not rotate and the oscillating frequency was $7{\sim}20\;Hz$. From the curve of the critical cavitation number versus flow rate, it was found that the steady cavitation performance of $6.1^{\circ}$ inducer was much lower than that of $7.8^{\circ},\;7.0^{\circ}$ inducers.

  • PDF

터보 펌프의 캐비테이션 실험 (Cavitation test of a high pressure turbo-pump)

  • 이종민;강신형;이경훈
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.353-360
    • /
    • 2003
  • Hydraulic performance and cavitation characteristics of fuel pump in turbo-pump were studied experimentally. The fuel pump has a centrifugal impeller with a separate inducer. In this paper, flow characteristics of inducer and impeller was experimentally investigated separately and together. Especially static pressure distribution of Inducer was examined in non-cavitation and cavitation conditions.

  • PDF