• 제목/요약/키워드: induced voltage/power

검색결과 319건 처리시간 0.032초

Implementation of Under Voltage Load Shedding for Fault Induced Delayed Voltage Recovery Phenomenon Alleviation

  • Lee, Yun-Hwan;Park, Bo-Hyun;Oh, Seung-Chan;Lee, Byong-Jun;Shin, Jeong-Hoon;Kim, Tae-Kyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.406-414
    • /
    • 2014
  • Significant penetration of induction motor loads into residential neighborhood and commercial regions of local transmission systems at least partially determine a vulnerability to a fault induced delayed voltage recovery (FIDVR) event. Highly concentrated induction motor loads with constant torque could stall in response to low voltages associated with system faults. FIDVR is caused by wide spread stalling of small HVAC units (residential air conditioner) during transmission level faults. An under voltage load shedding scheme (UVLS) can be an effective component in a strategy to manage FIDVR risk and limit the any potential disturbance. Under Voltage Load Shedding take advantage of the plan to recovery the voltage of the system by shedding the load ways to alleviation FIDVR.

교류 AT급전방식에서 병렬급전시 변전소간 전압위상차에 의한 루프전류에 관한 연구 (A Study on the Loop Current Induced by Voltage Phase Difference Substations during Parallel Feeding under the Alternating Current AT Electric Power Feeding Method)

  • 박재석;송중호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1997-2004
    • /
    • 2011
  • The $2{\times}25kv$ AT electric power feeding method in the A.C. electric train adopts the one-phase power feeding method as the standard due to a voltage phase difference, and the distance between the two neighboring substations is 50km due to voltage drop. The one-phase power feeding method makes the system operation feasible, while making it unfavorable for power supply. Moreover, railroad involves large-capacity single-phase load, and if it is expected to continue to rise, it is necessary to research on measures to stabilize the supply of power to railroad cars with the existing facilities. In this study, a parallel power feeding method between neighboring substations is proposed to stabilize the supply of electric power to electric railroad cars under the 2*25kv AT power feeding method and the loop current induced by voltage phase difference between the two neighboring substations during parallel power feeding is investigated.

  • PDF

Control and Analysis of Vienna Rectifier Used as the Generator-Side Converter of PMSG-based Wind Power Generation Systems

  • Zhao, Hongyan;Zheng, Trillion Q.;Li, Yan;Du, Jifei;Shi, Pu
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.212-221
    • /
    • 2017
  • Permanent-Magnet Synchronous Generators (PMSGs) are used widely in Wind Power Generation Systems (WPGSs), and the Vienna rectifier was recently proposed to be used as the generator-side converter to rectify the AC output voltage in PMSG-based WPGS. Compared to conventional six-switch two-level PWM (2L-PWM) converters, the Vienna rectifier has several advantages, such as higher efficiency, improved total harmonic distortion, etc. The motivation behind this paper is to verify the performance of direct-driven PMSG wind turbine system based-Vienna rectifier by using a simulated direct-driven PMSG WPGS. In addition, for the purpose of reducing the reactive power loss of PMSGs, this paper proposes an induced voltage sensing scheme which can make the stator current maintain accurate synchronization with the induced voltage. Meanwhile, considering the Neutral-Point Voltage (NPV) variation in the DC-side of the Vienna rectifier, a NPV balancing control strategy is added to the control system. In addition, both the effectiveness of the proposed method and the performance of the direct-driven PMSG based-Vienna rectifier are verified by simulation and experimental results.

가공배전선에 의한 유도전압 특성 분석 (An Analysis of the Induced Voltage characteristic on 22.9kV-Y Distribution Lines)

  • 임용훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.500-502
    • /
    • 2003
  • This paper reviews calculating of induced voltage onto a communication line from 22.9kV-Y Distribution Lines. The coexistence of both power line and communication line in parallel generates the induction of significant longitudinal voltage in the weak current line. In order to evaluate a precise induced voltage, this paper indicated some problems about coefficient and numerical formula. It also presents some induced voltage production technology standard application.

  • PDF

전력 유도 발생 시 케이블 쉬스 접지 여부에 따른 유도 잡음 전압 영향 분석 (Analysis on the Effects of the Induced Noise Voltage with the Grounded or Non-grounded Cable Sheath in the Power Inducting Situation)

  • 이상무;최문환;조평동
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.285-288
    • /
    • 2007
  • This article presents the change characteristics of induced noise whether the sheath layer of the cable is grounded or not. As what affects the induced noise, there are power influence or longitudinal transverse voltages and its weighted filtered voltage. The sheath ground is basicaly predicted to have the effects of alleviation on the power influence. But practically the effects may not happen in the case of common cable's sheath layer. Rather there are cases that the ground of sheath affects so that the noise level could increase. So we need to scrutinize the effects of the sheath gorund in the measures for the protection against electromagnetic induction by powerline or traction line system. And the evaluation of using the designated shielding purpose cable is needed.

  • PDF

IGBT 직렬 연결시 과전압 제한을 위한 게이트 구동기법 (An Imrpoved Gate Control Scheme for Overvoltage Clamping under IGBT Series Connection)

  • 김완종;최창호;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권2호
    • /
    • pp.83-88
    • /
    • 1999
  • Series connection of power semiconductor devices is selected in high voltage and high power applications. It is important to prevent the overvoltage from being induced across a device above ratings by the proper voltage balancing in the field of IGBT series connection. In addition, the overvoltage induced by a stray inductance has to be limited in the high power circuit. This paper proposes a new gate control scheme which can balance the voltage properly and limit the overshoot by controlling the slope of collector voltage under the turn-off transient in the series connected IGBTs. The proposed gate control scheme changes the slope of collector voltage by sensing the collector voltage and controlling the gate signal actively. The new series connected IGBT gate driver is made and its validity is verified by the experimental results for series connected IGBT circuit.

  • PDF

유도전위 검출방식을 이용한 크레인의 고압 전선로 접근 경보장치 개발 (Development of the Power Line Proximity Warning Apparatus for Mobile Crane using the Induced Voltage Measurement)

  • 최삼진;박찬원;김일환
    • 산업기술연구
    • /
    • 제21권A호
    • /
    • pp.213-219
    • /
    • 2001
  • This paper describes the power line proximity warning device for mobile crane by using the induced voltage measurement method. A mobile crane worker can be easily exposed to dangerous electrical shock and the electrocution while this are working at near the high-voltage electrical lines. In this paper, the derivation electric-potential of the power lines are simulated and microprocessor-based detecting device and transmitter/receiver modules are introduced to show a solution for the dangerous mobile crane working environment.

  • PDF

지중송전선로와 병행하는 기설통신선의 유도전압 분석 (Analysis of Induced Voltage in Parallel Telecommunication Cables from Underground Power Cables)

  • 임광식;장우석;한창석;홍동석;유진선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.523-524
    • /
    • 2011
  • This paper covers induced voltage in parallel telecommunication cable with underground power cable to be linked between substations. The simulation was carried out the induced voltage in telecommunication cable according to the transposition of power cables and fault location for various conditions. This study based on the EMTP/ATPDraw with actual underground cable systems while the power cables are in steady state and transient state.

  • PDF

송전계통에서 고장에 따른 Gas Pipeline 유도전압 분석 (A Fault Effect to Induced Voltage of Gas Pipeline in Transmission Systems)

  • 김현수;이상봉;김철환
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1720-1725
    • /
    • 2008
  • Because of the continuous increasing of energy consumption, metallic pipelines are widely used to supply services to customers such as gas, oil, water, etc. Most common metallic pipelines are underground and are now frequently being installed in nearby electric power lines. In recent years, buried gas pipeline close to power lines can be subjected to hazardous induction effects, especially during single line to ground faults. because it can cause corrosion and it poses a threat to the safety of workers responsible for maintenance. Accordingly, it is necessary to take into consideration for analysis of induced voltage on gas pipelines in transmission lines. This paper analyzed the induced voltage on the gas pipelines due to the 154kV transmission lines in normal case and in different faulty case conditions using EMTP (Electro-Magnetic Transients Program).

On the Lightning Induced Voltage Along Overhead Power Distribution Line

  • Izadi, Mahdi;Ab Kadir, Mohd Zainal Abidin;Hajikhani, Maryam
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1694-1703
    • /
    • 2014
  • Lightning induced voltage is a major factor that causes interruptions on distribution lines. In this paper, analytical expressions are proposed to evaluate a lightning induced voltage on power lines directly in the time domain without the need to apply any extra conversions. The proposed expressions can consider the widely used current functions and models in contrast to the earlier analytical expressions which had a number of limitations related to the simplification of the channel base current and the current along the lightning channel. The results show that the simulated values based on the proposed method are in good agreement with the previous studies and the proposed expressions can be used for optimizing the insulation and protection level of existing and new lines being designed.