• Title/Summary/Keyword: indoor product

Search Result 108, Processing Time 0.022 seconds

Estimation of the Formaldehyde Concentration of Subterranean Shopping Centers according to their Spatial Configuration and Renovation (지하도상가의 리모델링 및 공간 특성에 따른 포름알데히드 농도 분석)

  • Sim, Kyung-Sub;Kim, Hyunsoo;Yu, Seulgi;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.25 no.3
    • /
    • pp.182-187
    • /
    • 2014
  • Underground shopping center has become a important commercial facility due to their good accessibility to the public transport. However, underground shopping center has high risk of air contaminants emission like formaldehyde and lowered indoor air quality. In this study, formaldehyde concentration of the underground shopping center was estimated according to the renovation and characteristics of space. It was found that newly renovated underground shopping center has low formaldehyde concentration. In case of closed entrance type, the formaldehyde concentration was 320 % higher than open type. Formaldehyde concentration was varied by product type and especially, high formaldehyde concentration was measured near the stores selling nail polish and cosmetics. It is important to apply appropriate ventilation system according to characteristics of space.

  • PDF

Properties of Radon Absorbed Blast Furnace Slag Matrix using Palm Activated Carbon (야자활성탄을 활용한 라돈흡착형 고로슬래그 경화체의 특성)

  • Lee, Jae-Hoon;Park, Chae-Wool;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.160-161
    • /
    • 2019
  • Recently, a bed company's product has detected a certain level of radon or higher, making it a popular search word on portal sites. Because of this problem, people are becoming more interested in radon. The government plans to support the establishment of a radon alert system for households through a radon concentration survey of 10,000 households. The use of palm charcoal as an indoor finishing material will reduce the risk of lung cancer through radon reduction. The experiment used a method of replacing palm activated carbon with blast furnace slag, and the adsorption performance of radon tends to increase as the replacement rate of palm activated carbon increases.

  • PDF

Formaldehyde Deodorization Effect and Far-Infrared Emission Characteristics of Ceramics Prepared with Sawdust, Risk Husk, and Charcoal: Effect of Material Mixing Ratio

  • HWANG, Jung-Woo;OH, Seung-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.50 no.2
    • /
    • pp.104-112
    • /
    • 2022
  • Indoor air quality is a very important environmental factor in modern society. However, air pollutants generated from various interior construction materials significantly affect the human body, including formaldehyde (HCHO) and volatile organic compounds that threaten public health by deteriorating indoor air quality. Effective in removing these harmful substances are porous materials, such as woodceramics. In this study, charcoal, a porous material, was added to rice husk, an agricultural by-product, and sawdust generated during the sawing process to prepare boards and ceramics at different mixing ratios, and the HCHO deodorization performance and far-infrared emission characteristics were measured. As the mixing ratio of charcoal increased, the deodorization rate of the boards and ceramics tended to increase. Overall, the deodorization rate was measured to be 80% to 90%, indicating that the boards and ceramics prepared with charcoal are suitable to be used for the purpose of deodorization. The effect of the material mixing ratio on far-infrared emissivity and emission power was insignificant.

Characteristics of Exposure Distribution to Hazard Factors in Indoor Swimming Pool Activity Areas in Gwangju (수영장 활동공간 내 유해인자 노출특성 연구)

  • Lee, Youn-Goog;Kim, Nan-Hee;Choi, Young-Seop;Kim, Sun-Jung;Park, Ju-Hyun;Kang, Yu-Mi;Bae, Seok-Jin;Seo, Kye-Won;Kim, Jong-Min
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.2
    • /
    • pp.150-158
    • /
    • 2020
  • Objective: This study is designed to measure the concentration of DBPs (disinfection by-products) in pool water and in air and to estimate the carcinogenic potential through the evaluation of inhalation exposure. Methods: The subjects were six indoor swimming pools with many users in Gwangju. Samples of pool water and indoor air were taken every one month from August 2018 to August 2019 and analyzed for eight swimming pool standards. Three-liter air samples were collected and the VOCs were analyzed using GC/MS directly connected to thermal desorption. Results: pH was 6.8-7.5 and the concentration of free residual chlorine in pool water was 0.40-0.96 ?/ℓ. Physicochemical test items such as KMnO4 consumption and heavy metal items such as Aluminum met existing pool hygiene standards. No VOC materials were detected except for the DBPs. The concentration of THMs in the pool water was 11.05-41.77 ㎍/L and the THMs mainly consist of Chloroform (63-97%) and BDCM (3-31%). The concentration of indoor air THMs is 13.24-32.48 ㎍/㎥ and consists of Chloroform. The results of carcinogenic assessment of chloroform in the indoor swimming pool via inhalation exposure were 2.0 to 6.4 times higher than the 'acceptable risk level' suggested by the US EPA. Conclusions: The concentration of THMs in the pool water is 11.05-41.77 ㎍/L, most of which is chloroform. In addition, the concentration of indoor air THMs is 13.24-32.48 ㎍/㎥. The result of carcinogenic assessment of chloroform was 2.0 to 6.4 times higher than the 'acceptable risk level' suggested by the US EPA.

Exposure Assessment and Health Risk of Polybrominated Diphenyl Ether (PBDE) Flame Retardants in Indoor Environments of Children's Facilities in Korea

  • Kim, Ho-Hyun;Yang, Ji-Yeon;Jang, Yun-Suk;Lee, Yong-Jin;Lee, Chung-Soo;Shin, Dong-Chun;Lim, Young-Wook
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.4
    • /
    • pp.247-262
    • /
    • 2011
  • This study assessed the health risks of childhood exposure to PBDEs via different possible pathways in children's facilities and indoor playgrounds. When PBDE contamination was measured, it was determined through multiple routes, including inhalation of indoor dust, dermal contact with product surfaces and children's hands, and incidental dust ingestion. Samples were collected from various children's facilities (playrooms, daycare centers, kindergartens, and indoor playgrounds) during summer (Jul-Sep, 2007) and winter (Jan-Feb, 2008). The hazard index (HI) was estimated for non-carcinogens, and PBDEs, such as TeBDE, PeBDE, HxBDE, and DeBDE, were examined. The sensitivity to the compounds did not exceed 1.0 (HI) for any of the subjects in any facility. However, current data about toxicity does not reflect effects that were fully sensitive in children, so there is uncertainty in the dose-response data. The contribution rates of PBDEs were 71.4 to 96.1% and 3.7 to 28.2% for intake and inhalation exposure, respectively, indicating that intake of floor dust and inhalation are the primary routes.

Study on a Applicability of the Low Noise Labeling System for a Construction Machinery (건설기계 저소음표시제도 도입에 관한 연구)

  • Gu, Jinhoi;Lee, Wooseok;Seo, Chungyoul;Lee, Jaewon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.11
    • /
    • pp.982-986
    • /
    • 2013
  • The noise emitted from construction machinery has long been a cause of environmental disputes, especially to the nearby residents. In 2008, the Ministry of Environment adopted the construction machinery noise labeling system to encourage the development of the low noise construction machinery. After the implementation of the noise labeling system of the construction machinery, the noise emitted from the construction machinery has been decreased over the six years. But, as the quality of life improves, a growing number of people desire more comfortable and quite living environment. Under the situation, new systems like the low noise labeling system are considered to encourage the development of the low noise construction machinery. In accordance with the low noise labeling system, the construction machinery satisfying the standard of low noise are qualified to attach the low noise label in front of the products. Thus, the product qualified the low noise certification will be incentivized by the choice of the consumer. In this paper, we have studied the necessity of the low noise labeling system for the construction machinery and the considerations to adopt the low noise labeling system of construction machinery. And we have studied appropriate criterion to judge the low noise construction machinery. The considerations studied in this paper will be helpful to adopt the low noise labeling system of construction machinery in the future.

Optimization Method of Kalman Filter Parameters Based on Genetic Algorithm for Improvement of Indoor Positioning Accuracy of BLE Beacon (BLE Beacon의 실내 측위 정확도 향상을 위한 Genetic Algorithm 기반 Kalman Filter Parameters 최적화 방법)

  • Kim, Seong-Chang;Kim, Jin-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.11
    • /
    • pp.1551-1558
    • /
    • 2021
  • Beacon signals used in indoor positioning system are reflected and distorted, resulting in noise signals. KF(Kalman Filter) has been widely used to remove this noise. In order to apply the KF, optimization process considering the signal type, signal strength, and environmental elements of each product is required. In this paper, we propose a solution to the optimization problem of KF Parameters using GA(Genetic Algorithm) in BLE(Bluetooth Low Energy) Beacon-based indoor positioning system. After optimizing KF Parameters by applying the proposed technique with a certain distance between Beacon and receiver, we compared the estimated distance passed through KF with the unfiltered distance. The proposed technique is expected to reduce the time required and improve accuracy of KF Parameters optimization in an indoor positioning system based on RSSI (Received Signal Strength Indication).

Design Development of wall mount type air purifier (벽걸이 형식을 도입한 공기청정기 디자인 개발)

  • Han, Il-Woo
    • Archives of design research
    • /
    • v.18 no.3 s.61
    • /
    • pp.219-222
    • /
    • 2005
  • This study is for the design developement of wall mount air purification device used for pleasant and clean resident environment. As more people have the high standard of living, they are interested in the air quality of indoor environment, since it is believed its relationship with human health. Now the social demand of air purifier is increasing. Its market is growing and there are various design products in the market. However, dominant current products are floor-based standing type, it needs much spaces to install for the air inhalation and exhaust. Therefore, this product provides the space-saved design. Its concept comes from existing wall mount type air conditioners. The effect of wall decoration is another merit of this proposal. It has an easy filtering change and cleaning system and a simple operation of multiple functions. This product also has the perfect-matched slim design that is consist of natural curves with rectangle for any indoor spaces.

  • PDF

Analysis of Installation Environment and Fire Risk of Induction Motors Installed in the Curing Process of a Rubber Product Manufacturing Plant (고무제품제조공장의 가류공정에 설치된 유도전동기의 설치환경 및 화재위험성 분석)

  • Jong-Chan Lee;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.23-29
    • /
    • 2023
  • This study analyzed the fire status of a rubber product manufacturing factory based on 19 years of fire data. Through the analysis of the current state of fire, electrical fires accounted for 58.19%, and among electrical fires, motor fires were the highest at 26.21%. For the motor fire occurrence process, the curing process accounted for the highest rate of 51.9%. Therefore, the installation environment was investigated for the motor in the curing process, and it was confirmed that the motor's maximum ambient temperature exceeded 40℃. In particular, in the case of the motor for curing operation, the motor was installed in a separate motor room, so the average indoor temperature was 48.10℃ and the motor frame's maximum temperature was 72.80℃. In this study, the risk of motor fire was confirmed through a field survey, and a safety management plan was derived by finding a process with high fire risk and conducting an experiment on the motor's installation environment and electrical characteristics in that process.

VOCs Emission Characteristics of Coating Materials for Wood Finishing (목재용 마감도료의 휘발성유기화합물 방출특성)

  • Park, Sang-Bum;Lee, Min;Lee, Sang-Min;Kang, Yeong-Seok
    • Journal of the Korea Furniture Society
    • /
    • v.26 no.1
    • /
    • pp.22-30
    • /
    • 2015
  • In order to prevent decay, distortion, bending, twist on wood products such as wooden furnitures, variety of coating materials were developed and used so far. The coating materials for wood finishing can be synthesized by natural resource or petroleum. However, these coating materials can cause contamination of indoor air quality due to emission of volatile organic compounds (VOCs). In this study, commercialized coating materials for wood finishing such as varnish, coat, and stain were evaluated on emission characteristics of VOCs. Among the varnish, eco-friendly products had about 15~46% lower TVOC emission ($1,042{\mu}g/m^2h{\sim}3,257{\mu}g/m^2h$, respectively, than typical product ($7,100{\mu}g/m^2h$). Natural resource based coating material showed lowest TVOC emission level. However, one of natural resource based waterborne stain showed higher TVOC emission level because waterborne stain already contained higher amount of natural VOC. Oil-based stain might not be suitable for indoor use on interior wall and furniture due to exceed amount of TVOC. Based on results, natural resource based coat or waterborne stain are recommenced to use on wood products.