• 제목/요약/키워드: indoor airflow

검색결과 79건 처리시간 0.025초

기술사 마당 - 주방 후드 부스타 배기 방식

  • 진남기
    • 기술사
    • /
    • 제45권6호
    • /
    • pp.44-51
    • /
    • 2012
  • Local functional, closed the hood and exhaust are classified as open-style hood. Around the closed hood contaminants prevent the spread of contaminants. Surrounded Some pollutants (open-style hood is used in cases where the odor, vapor diffusion, and inferior) of indoor allowed to Hood expressions, which are used for kitchen, laboratory, factory canopy is typical. Contamination that occurs during cooking, kitchen ventilation barrier materials are the biggest problem, its solution by introducing fresh outside air in the kitchen troubleshoot and. Study on the kitchen exhaust airflow for my kitchen, and perform a number of each Institute and at the University of hydrodynamic analysis is investigated.

  • PDF

탑상형 아파트의 여름철 통풍성능 개선에 대한 연구 (A Study on the Improvement of Cross Ventilation Efficiency in a Tower Type Apartment in Summer Season)

  • 조근제;장현재
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.299-304
    • /
    • 2012
  • In terms of plane structure, tower-type apartments have several disadvantages compared to flat-type apartments in the aspect of ventilation rate. Such disadvantages may not produce good indoor cooling effects with natural ventilation inside the heated apartments in hot summer days, so they may cause high energy consumption by an increase in cooling load. The purpose of this study is to investigate ways for improving the indoor thermal environment of tower-type apartments in summer by conducting quantitative evaluations of the airflow distribution in households.

  • PDF

철도 전동차내의 실내공기질 평가 - 온도 및 습도를 중심으로 - (Evaluation of Indoor Air Quality in the Railroad Electric Rolling Stock - Focused on Temperature and Humidity -)

  • 박덕신;배상호;정우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.610-615
    • /
    • 2003
  • Electric rolling stock is one of major public transportation because of an increase in population and heavy traffic problems. The passengers under the influenced of indoor air quality such as air temperature, relative humidity and air velocity. Ventilation system on passenger cars should be designed for the health and comfort of the passengers. One of the main aim is to create an acceptable thermal environment without draught problems. The draught sensation increases when the air temperature decreases and the air velocity increases. Airflow in passenger cars is turbulent. Lateral temperature and humidity gradients in the electric rolling stock have been studied. And, the difference in the mean temperature and relative humidity measured at 0.7, 0.9, 1.2, 1.7 m above from the floor.

  • PDF

주동형태 변화에 따른 아파트 단지내 기류분석 및 단위주호의 환기성능에 관한 연구 (A Study on the Air Flow Characteristics in an Apartment Complex and Ventilation Performance of an Individual Unit for Improving IAQ)

  • 이정현;이승희;김태연
    • KIEAE Journal
    • /
    • 제5권3호
    • /
    • pp.11-16
    • /
    • 2005
  • The recent trends of high-density and high-rise in apartment housing have caused the problems of decrease in ventilation rates and increase of indoor pollutant contaminants. SHS(Sick House Syndrome) has now become a major issue and threats the health of residents. To solve these indoor air problems, increase in ventilation rate is considered as one of the most efficient approach. Thus, the recent housing development is pursuing improvement in the site design and the layout of apartment building blocks to promote natural ventilation is now investigated as one of the fundamental solutions. This study was focused on the air flow characteristics of outdoor environment in an apartment complex to keep the pollutants out of the site. Age of air and pressure difference have been used as indices of the outdoor air quality. Four different types of apartment building layouts have been analyzed by CFD simulation. This study again selected a real apartment housing complex as a case study model. By analyzing the pressure differences between the front and rear of an apartment building block, the ventilation performance in each individual unit was evaluated, and its impact on ventilation performance is investigated by analyzing the stagnant air around the apartment building blocks. During this process, existing patterns of apartment housing layout have been evaluated, and the most appropriate site layout has been chosen to analyze the outdoor airflow patterns. Based on the analysis of airflow patterns of site layout, the possibilities of improving ventilation performance of an individual apartment housing is proposed.

공조풍량별 식생바이오필터의 입자상 오염물질 저감효과 연구 (A Study on Particulate Matter Reduction Effects of Vegetation Bio-Filters by Airflow Volume)

  • 최부헌;김태한
    • 반도체디스플레이기술학회지
    • /
    • 제20권4호
    • /
    • pp.89-95
    • /
    • 2021
  • As the influence of fine dust on society spreads gradually, the public's interest in indoor air is increasingly rising. Air-purifying plants are drawing keen attention due to their natural purifying function enabled by plant physiology. However, as their fine dust reduction mechanism is limited to adsorption only, vegetation bio-filters that optimize purification effects through integration with air-conditioning systems is rising as an alternative. In accordance with the relevant standard test methods, this study looked into the fine dust reduction assessment method by air-conditioning airflow volume that can be used for the industrial spread of vegetation bio-filters. In the case of PM10 at 300 ㎍/m3, it was in the order of EG-B(3,500CMH, 29 min.) < EG-A (2,500CMH, 37 min.) < CG(0CMH, 64 min.) for reaching the maintenance level (100 ㎍/m3) of publicly used facilities. For reaching the WHO Guideline(50 ㎍/m3) requirement, it was in the order of EG-B (51 min.) < EG-A (160 min.) < CG (170 min.). In the case of PM2.5, it was in the order of EG-B (26 min.) < EG-A (33 min.) < CG (57 min.) for reaching the maintenance level (50 ㎍/m3) of publicly used facilities. It was in the order of EG-B (48 min) < EG-A (140 min) < CG (158 min) for reaching the WHO Guideline (25 ㎍/m3) requirement. The findings from the analysis showed that fine dust can be reduced most efficiently when the system is operated at 3,500CMH level. The limitation of this study is that due to the absence of a way of assessing the stress of plants in vegetation bio-filters, generating optimal air-conditioning air flow of the relevant system and economics analysis against the existing facility-type air purification system have been clarified, which should be explored further though follow-up studies.

조명기구의 발열부하 저감을 위한 배기풍량 연구 (A Study of Exhaust Air Flow for Cooling Load Reduction from Interior Lighting)

  • 오병길;정민호;김회서
    • 설비공학논문집
    • /
    • 제23권9호
    • /
    • pp.604-609
    • /
    • 2011
  • The increased quality of life requires indoor illumination environment to have illumination with higher intensity. The increase in indoor illumination goes hand in hand with increase in indoor heat load. Of late, the internal heat in the cooling load has been growing gradually and the proportion of the lighting load has been bigger in the cooling load. The objective of the experiment here is to estimate the proper exhaust air flow displacement to remove heat from different types of lighting equipment. The heat causing the cooling load in lighting equipment is the ratio of heat per watt and the ratio of space for heat. Experimental measurements of the constant temperature and humidity in chambers that exhaust air flow by changing the exhaust calorific value was measured. Using the Airflow exhaust heat from lighting fixture of this study should help to reduce House cooling load.

생물안전 3등급시설의 공기환경 예측 및 공조부하 절감에 대한 해석 (An Analytical Study on the Prediction of Indoor Air Quality and the Reduction of Air Conditioning Load in Bio Safety Level 3 Laboratory)

  • 홍진관;박현진
    • 설비공학논문집
    • /
    • 제24권11호
    • /
    • pp.813-822
    • /
    • 2012
  • In this study, the multizone simulation for biosafety of BSL3 lab. and energy simulation are carried out simultaneously by using linked model of CONTAM and TRNSYS. In BSL3 lab., annual energy consumption is approximately five to ten times more than the magnitude of the office building. This is because required air change rate is extremely large and it is difficult to maintain room pressure difference efficiently. To maintain pressure difference between laboratory rooms through sealing condition of doors and proper airflow control is significant. In this study, to predict indoor environment of the BSL3 lab.(Influenza A research lab.), the multizone simulation for four kinds of biohazard scenario is also performed as part of risk assessment. Multizone and energy simulation results by using linked model show that these approaches are used as a tool for the energy efficient design and operation method for the safer BSL3 lab. facilities.

초고층 주거건물에서 굴뚝효과와 외풍영향에 인한 실내 환기 기류해석 및 평가에 관한 연구 (A Numerical Analysis on the Indoor Air Ventilation by Stack Effect and Outdoor Wind in a High-rise Residential Building)

  • 김치완;임태건;안영철
    • 설비공학논문집
    • /
    • 제23권12호
    • /
    • pp.828-835
    • /
    • 2011
  • The purpose of this study is to analyze and evaluate the 3 types of indoor ventilation methods such as natural, mechanical, and hybrid ventilation in high-rise building which is affected by stack effect and outdoor air pressure. For the evaluation of the ventilation capacity, CFD simulation was performed in a typical high-rise residential building. The results of the simulations are as follows: 1) Natural ventilation method is not enough to the regulation. 2) In case of mechanical ventilation, congested area is occurred but meets the regulation. 3) In case of hybrid ventilation with stack effect, all the areas of indoor meet the regulation and congested area is reduced. 4) In case of high-rise building, the differences of ventilation rate among houses in the building are not large because the mechanical ventilation is main factor.

아파트 평면형에 따른 여름철 맞통풍 효과 비교 (A Comparative Study on the Cross-Ventilation Effect by the Floor Plan Type of Apartment House during Summer)

  • 김정민;최윤정
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2005년도 추계학술대회 논문집
    • /
    • pp.301-306
    • /
    • 2005
  • The purpose of this study is to make clear the cross-ventilation effect by floor plan type in apartment house during summer. The questionnaire survey was carried out during the 26$^{th}$ of August ${\sim}$ the 4$^{th}$ of September 2004. The respondents were 174 residents living in two subject apartment estates. One subject estate (we call A estate) was consisted apartment houses having cross-ventilation floor plan. The other subject estate (we cail B estate) was constructed apartment houses having ordinary floor plan. The field measurements of indoor thermal elements reflecting natural cooling effect by cross-ventilation were carried out at A house in A estate and at B house in B estate. The measurements in two subject houses were taken on simultaneously the 27$^{th}$ of August. The residents living in A apartment estate planed cross-ventilation type show positive responses on thermal sensation and airflow sensation. The averages indoor temperature and air velocity in the A house were 0.9 $^{\circ}$C lower and 0.29 m/s higher than the B house. Therefore, it was found that indoor thermal environment during summer in the house having cross-ventilation floor plan maintained more comfortable than the house having ordinary floor plan by natural cooling effect of cross-ventilation.

  • PDF

PFT법에 의한 수직적 3 ZONE 분할 조건에서의 환기량 측정 (Ventilation Measurement with PFT in Three-storied Detached House)

  • 김훈
    • 설비공학논문집
    • /
    • 제25권9호
    • /
    • pp.506-515
    • /
    • 2013
  • The PFT (PerFluorocarbon Tracergas Technique) is of advantage to field surveys for evaluating the ventilation condition, due to its simplicity and convenience. On the other hand, it requires researchers to make some additional considerations that include uncertainties, such as the substance concentration distribution in indoor air, representativeness of a sampler, deviation of emission sources, and analysis error. In this study, the PFT and $CO_2$ tracer gas methods were applied simultaneously, to evaluate the accuracy of PFT on six ventilation conditions in the three-storied detached house. The air exchange and the outdoor air introduction a between and into zones were measured. As the results, deviations of PFT concentration distributions were observed at a sufficiently low level for an accurate determination for a house where the interior height was large, and there were relatively many partition walls. However, when a uniform airflow appeared in the indoor air, it was also validated that the indoor air would be exhausted without sufficient mixing, and consequently the measurement error of the PFT would be large.