실내 급.배기구 위치변화에 따른 실 공기유동에 관한 연구 (A Study on the Indoor Airflow Pattern by Changing the Location of Mechanical Terminal Unit)

  • 최정민;조성우
    • 설비공학논문집
    • /
    • 제21권3호
    • /
    • pp.193-200
    • /
    • 2009
  • The ventilation system of apartments can be divided by supply and exhaust fan, supply fan and exhaust free and supply free and exhaust fan. Recently, the individual ventilation system and central ventilation system which is combined cooling system with duct system are applied to apartment ventilation system. The airflow pattern is affected by location of supply unit and exhaust unit in indoor. This study is to investigate the proper distance between supply unit and exhaust unit using CFD. As a result of this study, the proper distance between supply unit and exhaust unit could be suggested at the interval of 3 m in supply and exhaust fan system and 2.5 m in supply fan and exhaust free.

VAV 터미널 박스의 최소풍량 제어방식 비교 연구 (A Study on the Comparison Analysis of Minimum Airflow Control Logic of VAV Terminal Box)

  • 조영흠;강수현;성윤복
    • 한국태양에너지학회 논문집
    • /
    • 제32권4호
    • /
    • pp.96-102
    • /
    • 2012
  • The minimum airflow of VAV terminal boxes is a key factor for comfort, indoor air quality(IAQ) and energy cost. If the minimum airflow is not reasonable, it would waste energy and make IAQ problems. There are two types of VAV terminal box control logic. One is the single maximum, another is the dual maximum control logic. Dual maximum control logic is more efficiency way to reduce the energy consumption. It has a minimum airflow set point and a heating maximum set point. It allows the minimum airflow set point to be much lower than single maximum control logic. A building simulation was conducted to evaluate the energy consumption and the IAQ according to the control logic of the V AV terminal box. In the simulation, dual maximum control logic can save the energy up to 6.5% compared to the single maximum control logic.

강의실에서 환기시스템과 난방시스템의 풍량에 따른 PMV와 $CO_2$ 농도 특성 비교 (Comparison of the PMV and $CO_2$ concentration Characteristic in the Lecture Room with a Different Airflow rate of the Ventilation System and Heating System for heating season)

  • 한창우;노광철;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.411-416
    • /
    • 2006
  • In this paper, we performed the experimental and numerical study on the thermal comfort(TC) and indoor air quality(IAQ) in the lecture room with a different airflow rate of the ventilation system and heating system for heating season. Through the experimental results, we found out that there was considerably difference of the PMV but there was little difference of $CO_2$ concentration with a different heating system. From a numerical results, the best operating condition was that discharge airflow rate of SAC is 29 CMM and supply airflow rate of the ventilation system is 1,200 CMH from a viewpoint of TC and IAQ.

  • PDF

30CMM급 태양기공 전기집진 설비의 실내분진 정화 능력에 관한 실험연구 (An Experimental Study of 30CMM Solar Transpired Collector and Cyclone(STCC) System on Indoor Air Dust Removal Performance)

  • 노지희;박상현;강은철;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제25권3호
    • /
    • pp.37-45
    • /
    • 2005
  • Higher requirement of advanced building design code and the development of construction technique have resulted in more thermal and air tight buildings. This has caused the sick building syndrome in a indoor air quality has been relatively getting worse. A new concept with a solar fresh air heating and electrostatic precipitator or called as STCC(Solar Transpired Collector and Cyclone) has been proposed to solve this IAQ issue. This paper describes the assessment study of STCC system under different outdoor airflow rates. The experiment was carried out under real condition with 30CMM STCC system test facility. Incense smoke was used to study the particle concentration decay trends under outdoor airflow rates 0CMM, 10CMM, 20CMM, 30CMM, with applied voltages of 5kV and 15kV for collecting and discharging electrodes of an Electrostatic Precipitator. Result shows that the particle decay increases by increasing the outdoor airflow rates. The collection efficiency, dust cleaning effectiveness(P) and application area calculation result comparisons have also been studied. This factors could be used to estimate how a dust of indoor air quality(IAQ) and removed for a building space with a STCC system.

빌딩 내의 공기유동량 예측을 위한 누입 및 환기모델의 개발 (Development of an Infiltration and Ventilation Model for Predicting Airflow Rates within Buildings)

  • 조석호
    • 한국환경과학회지
    • /
    • 제23권2호
    • /
    • pp.207-218
    • /
    • 2014
  • A ventilation model was developed for predicting the air change per hour(ACH) in buildings and the airflow rates between zones of a multi-room building. In this model, the important parameters used in the calculation of airflow are wind velocity, wind direction, terrain effect, shielding effect by surrounding buildings, the effect of the window type and insect screening, etc. Also, the resulting set of mass balance equations required for the process of calculation of airflow rates are solved using a Conte-De Boor method. When this model was applied to the building which had been tested by Chandra et al.(1983), the comparison of predicted results by this study with measured results by Chandra et al. indicated that their variations were within -10%~+12%. Also, this model was applied to a building with five zones. As a result, when the wind velocity and direction did not change, terrain characteristics influenced the largest and window types influenced the least on building ventilation among terrain characteristics, local shieldings, and window types. Except for easterly and westerly winds, the ACH increased depending on wind velocity. The wind direction had influence on the airflow rates and directions through openings in building. Thus, this model can be available for predicting the airflow rates within buildings, and the results of this study can be useful for the quantification of airflow that is essential to the research of indoor air quality(temperature, humidity, or contaminant concentration) as well as to the design of building with high energy efficiency.

전열교환기의 세대내 풍량 분배를 위한 CFD를 이용한 최적설계방안 (Optimal Design for Airflow Distribution of Total Heat Exchanger in House Using CFD)

  • 김진호;송난정;이건태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.701-705
    • /
    • 2009
  • After revision of law of architecture in 2006, all houses which have more 100 households must has ventilation unit for the indoor air quality. Optimal design of the natural and the mechanical ventilation has being considered. In this paper, it is carried out about optimal design for airflow distribution of total heat exchanger in houses using CFD. As the result, first design of ventilation has some problem in porch area. Adding diffusers in porch area and changing diffuser schedule make more efficient ventilation than original design.

  • PDF

환기 중인 온실의 공기유동에 관한 실험적 연구 (Experiment on Airflow in Ventilated Greenhouse)

  • 윤남규;김문기
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.429-433
    • /
    • 1999
  • The experiment was conducted to predict air movements and to analyzxe the ventilation characteristics in ventilated greenhouse. Relatively high wind velocity was checked near windward inlet, but near leeward outlet and indoor very low wind velocity near to zero was checked . Despite of much influent air, indoor temperature was watched as high values uniformly due to inadequate air flow in greenhouse and low ventilation efficiency of the greenhouse.

  • PDF

공동주택의 기밀성능에 따른 실외 유입 및 실내 발생 PM2.5의 계절별 실내농도 기여도 분석 (Seasonal Contribution of Indoor generated- and Outdoor Originating PM2.5 to Indoor Concentration Depending on Airtightness of Apartment Units)

  • 박보람;최동희;강동화
    • 대한건축학회논문집:구조계
    • /
    • 제36권2호
    • /
    • pp.155-163
    • /
    • 2020
  • Indoor airborne particles are consisted of outdoor- and indoor-generated particles, which can be characterized by their compositions, generation features and toxicity. The identification of source contribution of indoor and outdoor origin to indoor particles is important to understand PM2.5 transport in a building as well as its impact on occupant health. The objective of this study is to investigate seasonal source contribution to indoor PM2.5 concentration depending on airtightness of apartment units. To evaluate the source contribution, particle transport including penetration, generation, exfiltration in an apartment housing unit was simulated by using CONTAM with particle and airflow simulation parameters obtained from field measurements. The result showed that the outdoor source contribution to indoor air was relatively dominant in the leaky housing unit during spring (77.2%) and winter (73.9%), and the indoor source was dominant in the airtight housing unit during summer (60.3%) and fall (60.7%). These results indicate the seasonal health risk of indoor PM2.5 can be varied according to airtightness of apartment units.

건축자재로부터 방출되는 라돈의 실내 확산에 대한 수치해석적 연구 (Numerical Study on Indoor Dispersion of Radon Emitted from Building Materials)

  • 박훈채;최항석;조승연;김선홍
    • 대한환경공학회지
    • /
    • 제36권5호
    • /
    • pp.325-332
    • /
    • 2014
  • 전 세계적으로 라돈에 대한 관심이 증대되면서 실내 라돈 농도를 저감하기 위한 노력이 여러 분야에서 진행 중이다. 실내 라돈의 저감 기술 개발을 위해서는 라돈의 실내 유입 및 방출 차단에 대한 예측 및 평가방법에 대한 기술 개발이 필요하다. 따라서 본 연구에서는 건축자재에서 방출되는 라돈의 실내 확산을 전산모델링 하여 해석적 방법과 비교하였으며, CFD 해석을 통하여 환기조건, 환기량, 건축자재 변화에 따른 건물 내 기류 특성과 라돈 농도를 평가하였다. 실내 라돈 농도는 실내 기류의 재순환 영역이 형성되는 곳에서 높게 분포하였으며, 환기량이 증가할수록 감소하였다. 건축자재별 실내 라돈 농도는 시멘트 벽돌이 가장 높았으며, 그 다음 에코카라트, 석고보드 순으로 나타났다. 본 연구의 결과는 실내 라돈 저감을 위한 건축재료의 선정과 실내 라돈 예측 및 평가 방법으로 적용이 가능할 것으로 판단된다.