Numerical Study on Indoor Dispersion of Radon Emitted from Building Materials  

Park, Hoon Chae (Department of Environmental Engineering, Yonsei University)
Choi, Hang Seok (Department of Environmental Engineering, Yonsei University)
Cho, Seung Yeon (Department of Environmental Engineering, Yonsei University)
Kim, Seon Hong (Department of Environmental Engineering, Yonsei University)
Publication Information
Abstract
Growing concerns about harmful influence of radon on human body, many efforts are being made to decrease indoor radon concentration in advanced countries. To develop an indoor radon reduction technology, it is necessary to develop a technology to predict and evaluate indoor inflow and emission of radon. In line with that, the present study performed computational modelling of indoor dispersion of radon emitted from building materials. The computational model was validated by comparing computational results with analytical results. This study employed CFD (Computational Fluid Dynamics) analysis to evaluate the radon concentration and the airflow characteristics. Air change rate and ventilation condition were changed and several building materials having different radon emission characteristics were considered. From the results, the indoor radon concentration was high at flow recirculation zones and inversely proportional to the air change rate. For the different building materials, the indoor radon concentration was found to be highest in cement bricks, followed by eco-carats and plaster boards in the order. The findings from this study will be used as a method for selecting building materials and predicting and evaluating the amount of indoor radon in order to reduce indoor radon.
Keywords
Indoor Radon; Building Material; CFD; Indoor Airflow;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Kim, Y. S., "Indoor raton levels in four different areas in Korea," Kor. J. Environ. Health Soc., 16(1), 1-7(1990).   DOI
2 International Agency for Research on Cancer, "Monographs on the evaluation on carcinogenic risk to humans: Man-made fibres and radon," (1988).
3 Page, S., "EPA's strategy to reduce risk of radon," J. Environ. Health, 56(5), 27-36(1993).
4 Grader, J. B., "Indoor air issue," Architectural Technology(1986).
5 Park, J. C., Lee, S. H. and Lee, E. K., "A study on the characteristics of radon concentration in newly-constructed apartment houses," Proceeding of annual conference of the architectural institute of Korea planning & Design, Architectural Institute of Korea, AIK, pp. 349-354(1994).
6 Fang, J. B. and Persily, A. K., "Computer simulations of airflow and radon transport in four large buildings," Environmental Protection Agency(1995).
7 Wang, F. and Ward, I. C., "The development of a radon entry model for a house with a cellar," Building Environ., 35(7), 615-631(2000).   DOI   ScienceOn
8 Zhou, W., Lida, T., Moriizumi, J., Aoyagi, T. and Takahashi, I., "Simulation of the concentration and distributions of indoor radon and thoron," Radiation Protection Dosimetry, 93(4), 357-367(2001).   DOI   ScienceOn
9 Akbari, K., Mahmoudi, J. and Ghanbari, M., "Influence of indoor air conditions on radon concentration in a detached house," J. Environ. Radioactivity, 116, 166-173(2013).   DOI   ScienceOn
10 Kim, S. A., "Plane change and tendency of 85 $m^2$ area for exclusive use of the apartment house," Engineering & Construction Technology Review, pp. 17-25(2003).
11 Ju, Y. J., "The measurement of radon-222 concentration for release gas into the atmosphere from the building material," Mater's thesis, Graduate School of Chosun University(2012).
12 Petropoulos, N. P., Anagnostakis, M. J. and Simopoulos, S. E., "Building materials radon exhalation rate: ERRICCA intercomparison exercise results," Sci. Total Environ., 272(1), 109-118(2001).   DOI   ScienceOn
13 Word Health Organization, "WHO handbook on indoor radon: A public health perspective," (2009).
14 Lee, E. K., Lee B. D. and Park J. C., "A study on the indoor air quality in newly-constructed apartment houses," Proceeding of annual conference of the architectural institute of Korea planning & Design, Architectural Institute of Korea, AIK, pp. 311-316(1994).