• 제목/요약/키워드: indoor air quality

검색결과 1,009건 처리시간 0.023초

A Pilot Study of Improving the Atmospheric Environment of Classroom for Students' Learning Activities

  • Kim, Tae-Han;Lee, Hanju;Choi, Boo-Hun;Hyun, Hye Sun
    • 인간식물환경학회지
    • /
    • 제24권2호
    • /
    • pp.179-194
    • /
    • 2021
  • Background and objective: Plant-based biofilter system has become a promising candidate for improving indoor air quality due to its eco-friendly and sustainable nature. However, it remains controversial whether indoor air purification using a biofilter is effective. Methods: This study used the one-group pre- and post-test design to analyze the effects of the operation of the plant-based biofilter system on indoor air quality, students' perception of indoor air quality, health effects, and subjective and objective attentiveness. Results: Results of this study show that the application of the plant-based biofilter system changed the air environment in the classroom. The operation of the plant-based biofilter system significantly decreased PM2.5 and PM10 and slightly increased temperature and humidity. Satisfaction with air quality and subjective attentiveness were significantly improved but objective attentiveness and health effects were not improved. Conclusion: Further studies need to be conducted for improving indoor air quality of schools and evaluating the health effects and attention of occupants to present the objective performance of the plant-based biofilter system.

VAV/BPFS를 이용한 실내공기 오염물질의 효율적 제어 (Effective Control of Indoor Air Pollutant using VAV/BPFS)

  • 최성우
    • 한국환경과학회지
    • /
    • 제7권3호
    • /
    • pp.327-334
    • /
    • 1998
  • The oil crisis of the 1970s and the rise in oil prices motivated people to implement energy conservation strategies. Buildings were fitted with additional Insulation and reduced ventilation rates. The reduction of mechanical and natural ventilation rate led to Increases In Indoor pollutant concentrations which result- ed In Increased health risks from Indoor exposure to pollutants. The variable-air-volume /bypass fitration system/VAV/BPFS) is a variation of the conventional VAV systems, The VAV/BPFS is an electronically controlled system that provides costegectlve thermal comfort and acceptable indoor air quality Under controlled conditions In a chamber, a series experiments were performed to compare the ability of a VAV/BPFS to remove Indoor aerosol concentration and to reduce energy consumption no that ability of conventional VAV system. Results show that the VAV/BPFS Increases the effective ventilation rate and removes indoor air pollutant, and maintains acceptable indoor air Quality without sacrificing energy consumption.

  • PDF

군 내무실의 실내공기질 개선을 위한 환기량 산정에 관한 연구 (A Study on the Calculation of Ventilation Rate for the Improvement of Indoor Air Quality on the Barracks)

  • 최정민;유진상;정영일
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.1043-1049
    • /
    • 2005
  • The purpose of this study is to improve indoor air quality of the barracks which have been changed from floor-type living barracks to bed-type living barracks since 2003. Therefore, the ventilation rates of newly constructed two type barracks were simulated with the various building materials including VOCs and HCHO components. And indoor air quality of two type living barracks was measured by the field experiments. With these steps, the measures for upgrading indoor air quality depending on building material types and ventilation rate are suggested.

학교건물의 실내공기환경 개선방안에 관한 건축계획적 연구 (Architectural Implementation of the Indoor Air Quality in the Elementary School Classroom)

  • 구재오;배선철;김곤
    • KIEAE Journal
    • /
    • 제7권1호
    • /
    • pp.15-22
    • /
    • 2007
  • Indoor air quality(IAQ) problems are not limited to large office buildings that are inadequately operated. In fact, many school buildings have significant potentials of air pollution and indoor air pollutants may be of particular concern because it is estimated that most young students who are physically weak to the pollutants spend about 90% of their time in classrooms. The goal of the study is to provide academic and architectural information on the major factors that influence indoor air quality in the elementary school. In order to gain a better understanding of IAQ problems in schools, a series of measurement studies of indoor air quality were designed and 3 different elementary school buildings located in Chuncheon were selected. The levels of CO, $CO_2$, and total volatile organic compounds(TVOCs) including formaldehyde(HCHO), major concern of this study, were measured in absence of students after class. As the results, it is noticeable that most indoor air pollution comes from sources inside the building, which are, for example, adhesives, upholstery, manufactured wood products, art and scientific supplies. The level of CO was measured similarly to that of outdoors, which means no impact on the indoor air problems since it is lower than the code. Ventilation played an important role in the level of $CO_2$ of which difference was 1.7 times in rough and 230 % of difference in the level was detected among the 3 school buildings. This concludes that indoor air problems might be result of poor building design with inadequate location of corridors within space organization or occupant activity patterns of ventilation.

유전 알고리즘을 이용한 어린이 시설의 실내 공기질 분석 (Indoor air quality analysis based on genetic algorithm for childhood facilities)

  • 박서연;우창규
    • 한국입자에어로졸학회지
    • /
    • 제20권1호
    • /
    • pp.1-11
    • /
    • 2024
  • Children are vulnerable to bad indoor air quality, and many researches on indoor air quality have been done with various methodologies. Herein, we used the genetic algorithm, one of the optimization methods, for the analysis based on better estimation values that are not easy to measure. A children playroom and a Taekwondo gym were chosen for the different degree of physical activity. After estimation of the number of occupants, the generation degree of CO2 and PM2.5 were determined from the data of the indoor air quality monitors. Relative errors were below 1% for all cases. Due to many air-treating electronics, the PM2.5 in the children playroom was well-managed compared to that in the Taekwondo gym. The PM2.5-generating activities were calculated and that of the Taekwondo gym was higher than that of the children playroom. The PM2.5 generating values were on the positive relationship with CO2 generating values. This means that we can obtain meaningful information from limited measurement data. For the numerous children facilities, indoor air quality can be easily analyzed and this might contribute to enhancing the children health.

수도권 지하철 지하역사의 실내공기질 연구 (Study on the Air Quality of Metropolitan Subway Stations)

  • 조영민;박덕신;박병현;박은영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.77-82
    • /
    • 2005
  • Recently, people's rising interests toward a 'well-being' lifestyle together with research contributions are accelerating the concerns regarding indoor air pollution making indoor air quality management an emerging environmental challenge of the era. The Ministry of Environment began to regulate the air quality of railway stations last year. The newly established 'Indoor Air Quality Act' covers 17 facilities whereas only underground subway stations and underground markets were regulated by previous 'Underground Air Quality Management Act' of 1996. In this study, we carried out the measurement of temperature, relative humidity, CO(carbon monooxide), $CO_2$(carbon dioxide), HCHO(formaldehyde), PM-10(particulate matters), and VOCs(volatile organic compounds) in underground subway stations. Based on the obtained results, we will suggest a way to improve the indoor air quality of the subway stations.

  • PDF

중소도시 공동주택의 실내공기질(새집증후군) 실측에 관한 연구 (Field Measurements of Indoor Air Quality in Apartment Units at Medium-size Cities)

  • 윤재옥
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.81-86
    • /
    • 2010
  • The main sources of the new house syndrome(sometimes it called sick building syndrome) are a concentration of formaldehyde (HCHO) and a concentration of total volatile organic compounds(TVOC). I had field measurements of indoor air quality in the apartment unit at medium-size cities(Y city, C city). I measured indoor air temperature, HCHO concentration in 16 units, TVOC concentration in 6 units and air tightness in 7 units. And I measured outdoor air quality, HCHO concentration and TVOC concentration. Mean concentration of HCHO was $357{\mu}g/m^3$(2006 standard=$120{\mu}g/m^3$), mean concentration of TVOC was $3,092{\mu}g/m^3$ and mean effective air leakage area was 193 cm2. There was a close relation between the indoor air temperature and HCHO concentration, between the indoor air temperature and TVOC concentration. Air tightness also had relation.

키즈카페의 가구류 및 설치시설에 따른 실내공기질 비교 분석 (Kids Cafe Indoor Air Quality Analysis Based on Furniture and Installation Facilities)

  • 박영훈;김선웅;양희훈;정옥영;이상진
    • 한국가구학회지
    • /
    • 제24권1호
    • /
    • pp.70-78
    • /
    • 2013
  • Indoor air quality control has been strengthened within childcare facilities and welfare communities for the elderly and infirm. I have researched the indoor air quality of kids caf$\acute{e}$s. The quality was determined by the measurement of $CO_2$ and HCHO, and the result was used in understanding of the current status of indoor air quality control. The higher level of $CO_2$ and HCHO were found in the playground area where children use compared to the area for guardians in kids caf$\acute{e}$s. And the more people in the caf$\acute{e}$s, the more $CO_2$ and HCHO were generated. It is judged that kids furniture produce harmful substances for children. Hence, the government regulations for kids caf$\acute{e}$s should be improved by reinforcing the indoor air quality control, considering that the main customers are children not adults.

  • PDF

실내공기질을 고려한 공동주택의 하이브리드 환기 시스템의 운영에 관한 연구 (A Study on the Operational Strategy for Hybrid Ventilation System in Apartment unit focused on Indoor Air Quality)

  • 이용준;이승복;이경회
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.203-210
    • /
    • 2004
  • This dissertation identifies and investigates the possible control modes of hybrid ventilation system in applying to general apartments. It evaluates range of hybrid ventilation control modes in terms of indoor air quality, thermal comfort, and energy consumption in a living room and a kitchen of the $1000m^2$ apartment. The TRNSYS simulation program was used for evaluating the following four ventilation types : A ventilation mode relying on only infiltration for supplying air, A natural ventilation mode considering with weather condition, A hybrid ventilation (natural + mechanical ventilation) mode allowing minimum ventilation with no heat exchange, and a hybrid ventilation mode with heat exchange. This study shows the following results. As temperature being controlled by heating cooling equipments, there is without significant difference in thermal performance among ventilation types. Regarding Indoor Air quality, Indoor air contamination level of the hybrid ventilation case consistently keep the lower levels. The hybrid ventilation modes consume more energy by a 49% as compared to the A ventilation mode relying on only infiltration for supplying air. It is caused by the continuous ventilation for keeping good indoor air quality; the increase of energy consumption can be attributable to the increase of the heating energy. Therefore, the heat exchange between indoor and outdoor air is required during heating season in severe weather conditions. During the cooling seasons, Introducing natural ventilation can achieve energy saving by 40 ~ 45%. Thus, it can be an effective strategies for energy saving. Based on these results, a hybrid ventilation system can be suggested as an effective ventilation strategy for archiving high level of indoor air quality, thermal comfort, and energy consumption.

학교 실내 환경의 실내공기질 인식에 관한 연구 (A study of Recognition of Indoor Air Quality of Indoor Environment at School)

  • 홍은주;김정덕;전용택;이치원;문정숙;손부순
    • 환경위생공학
    • /
    • 제22권3호
    • /
    • pp.51-64
    • /
    • 2007
  • This research, selected for 40 classrooms(20 old, 20 new) in chungnam area from June 22 to July 19 and from November 21 to December 30, 2003, in order to study of Recognition of Indoor Air Quality of Indoor Environment at School. we used Questionnaire for 193 health teachers, 41 teachers, and 1,359 students. The results of study are as follows. 1. To the question 'Currently Were you damage caused by classroom air?', showed that worry class teachers more than students with 43.9% of class teachers, 35.9% of health teachers and 23.5% of students. 2. To the question 'What would be an efficient way to manage classroom sanitation?', 50% of class teachers, 40.5% of health teachers and 47.4% of students wanted 'installation of air purifier.' 3. To the question 'How are you getting information about indoor air pollution?', showed that all of 3 groups get information through on TV. 4. According to survey, Health teachers who act as health supervisors appeared to have more prior knowledge air quality than class teachers and students. The results of this research show insufficient understanding of health risks from indoor air pollution, and shows possible health problems to students from school indoor air pollution. Therefore, these results suggested that a logical and systematic education program for students about the importance of indoor air quality should be carried out.