• 제목/요약/키워드: indoor air quality(IAQ)

검색결과 186건 처리시간 0.025초

공동주택에서 환기장치류 가동특성에 따른 실내공기질 변화특성에 관한 연구 (The Effects to Indoor Air Quality as Ventilation System Operation in Apartment House Using CFD Simulation)

  • 김석근;이정재
    • 설비공학논문집
    • /
    • 제19권2호
    • /
    • pp.142-148
    • /
    • 2007
  • The purpose of this study is to suggest the effective ventilation strategies and control methods that can minimize energy cost maintaining acceptable IAQ level in apartment house. The effects of the air-cleaning and heat-recovery ventilation system on IAQ under various operating conditions are investigated based on the experimental and CFD analyzed results. The results can be summarized as follows. (1) When a ventilator is not operated, the concentration of several pollutants may highly show in the house even though environment-friendly building materials are applied. Therefore, a mechanical ventilation system is required to obtain proper ventilation. (2) The pollutant concentration is noticeably deceased under air-cleaning/ventilation mode of air-clinic system, however, pollutant of kitchen is stagnant, because fresh air is not carried into the kitchen. (3) When air-clinic system is only equipped at master bedroom and living room, the system does not effectively deliver fresh air throughout the whole house, and then high pollutant concentration is obtained in each room. In contrast the average pollutant concentration meets the guideline when air-clinic system is installed at each room. (4) The air-cleaning/ventilation mode significantly affects on room ventilation in comparison with ventilation mode only.

공동주택의 실내공기환경 개선에 관한 연구 (A Study on the Improvement of Indoor Air Quality in Apartment Buildings)

  • 이상형;박진철;이언구
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.397-412
    • /
    • 1996
  • This study aims to present the fundamental strategies to improve the Indoor Air Quality (IAQ) in apartment buildings. To investigate the concentration of indoor air pollutants such as radon, formaldehyde, and VOCs, both the document survey and the field measurement were conducted. In addition, to identify the source of the air pollutants, the laboratory experiment was carried out for various building materials. Finally, the minimum period to be reserved befor3e building occupation to ensure healthy IAQ, which largely depends on the ventilation rates, was simulated using a simple compuer program. The results of this study can be summarized as follows: 1. In case of newly-constructed apartment houses, concentrations of formaldehyde, VOCs and radon were found to exceed the standard. Meanwhile, at existing apartment houses, concentrations of VOCs, particularly toluene and xylene, highly exceeded the standasrd level. Concentrations of formaldehyde and radon, however, had been lowered according to the duration of occupation. 2. The laboratory experiment of concentration of pollutants per square meter of building material surface area showed that radon gas was much emitted from the gypsumboard; formaldehyde from flooring and wallpaper; and VOCs from paints and kitchen furnishings. The emission rates of formaldehyde and VOCs were proportional to air temperature. 3. According to the simulation of the minimum period to be reserved before occupation, newly-constructed airtight houses required about 190-200 days, and naturally ventialted houses with fully-open-windows required about 20-45days, in order to keep the level of radon gas lower than standard. Therefore, with the current practice, the date of occupation should be delayed for about 15 days.

  • PDF

실내공기질의 건강성능 평가모델 연구 (A Health Performance Evaluation Model of Building Indoor Air Quality)

  • 정기;이동훈;최재휘;김선국
    • KIEAE Journal
    • /
    • 제10권3호
    • /
    • pp.3-10
    • /
    • 2010
  • As indoor air quality directly affects health and comforts of the residents, researchers from different countries have continued to explore criteria by which indoor air quality can be indicated in a scientific and quantitative manner over the past several decades. However, there are many possibilities that can deteriorate indoor air quality. Due to the uncertainty of influence factors, it is quite difficult to develop a correct evaluation model and quantitative method. Furthermore, the effects from the indoor air pollutants have different levels, leading to the difficulties to apply the regular standard. This study aims to propose evaluation criteria by using the FD-AHP analysis. Obtained findings will be beneficial to construct apartment buildings, commercial buildings and others health performance evaluation framework.

아파트 실내공기질 현장측정에 의한 전열교환 청정환기유니트 성능평가 (IAQ Field Survey in an Apartment Housing Equiped for Heat Recovery Ventilation System with Air Cleaning Function)

  • 이정재;이중훈;이승민
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.688-693
    • /
    • 2005
  • Nowaday the natural ventilation rate decreases because the apartment housing is being air-tight. Therefore, Indoor Air Quality (IAQ) and indoor environment grow worse. Especially, Formaldehyde (HCHO), Volatile Organic Compounds (VOCs) which is emitted from the building materials and coating material etc. occur Sick House Syndrome that cause negative impact on resident's respiratory system and body. Therefore in construction field, it will be a important issues that development of a ventilation system with high effectiveness which can exhaust the contaminant out of the building quickly. In this research we evaluated 'wall attachable duct-less Heat Recovery Ventilation (HRV) system with air cleaning function'. We executed a synthetic evaluation about indoor air environment under various operating condition installing the system in real scale apartment house that is built in Anyang city. HRV system with air cleaning function showed good performance by removing HCHO, VOCs with less ventilation energy.

시내버스 실내공기질 IAQ 종합지수 개발 (Development of IAQ Index for Indoor Air Quality in City Buses)

  • 전보일;곽민정;강상현;김종철;윤현준;김호현
    • 한국환경보건학회지
    • /
    • 제46권4호
    • /
    • pp.444-456
    • /
    • 2020
  • Objectives: This study developed an index for the indoor air quality management of city buses to allow the provision of indoor air quality information to city bus users. Methods: Nine city buses in Seoul were measured for PM10, PM2.5, CO2, temperature, and relative humidity through IoT sensors. Big data collected through the sensors was analyzed to identify indoor air quality on city buses and graded through the index. Results: As a result of dividing the measured city bus data into five grades through the IAQ index, PM10 was rated "good" for 30.4% of the total measured values, and 9.2% were rated "risky". For PM2.5, 67.7 percent were rated "good" and 0.4 percent were rated "risky". For CO2, 0.9% were 'good' and 1.1% were 'risky'. The results of the classification through the IAQ index for city buses showed that the impact of good, normal, sensitive, bad, and dangerous were 2.7, 38.8, 46.0, 12.4, and 0.1%, respectively. According to the analysis by measurement area, Seocho-gu, Gangnam-gu, Seongdong-gu, Gwangjin-gu, and Dobong-gu are "normal" and other areas (Seodaemoon-gu, Jongno-gu, Yongsan-gu, Jung-gu, Seongbuk-gu, Dongdaemun-gu, Junggye-gu, Gangbuk-gu, and Nowon-gu) are all rated "sensitive". Conclusions: When analyzing cases where PM10 and CO2 indices are in the "bad" zone, the concentration is generally found to increase during rush hour, during which there are a large number of passengers. It is expected that indoor air quality management in vehicles will be necessary during rush hour.

A Survey of Characterization Airborne Bio-aerosol Concentration in Public Facilities

  • Kim, Yoon-Shin;Roh, Young-Man;Hong, Seung-Cheol;Lee, Choel-Min;Jun, Hyung-Jin;Kim, Jong-Choel;Song, Min-Kyung
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 국제학술대회
    • /
    • pp.273-278
    • /
    • 2005
  • This study was performed to investigate the characteristics of distribution for airborne bio aerosol in 11 public facilities in Seoul from June to July. The collected samples are total suspended bacteria in indoor and outdoor Anderson six stage air sampler by the IAQ standard method of Ministry of Environment in Korea. The concentration of total suspended bacteria in the theater higher than IAQ standards. As the results of the survey, the most high indoor air mean concentration of bacteria $1273CFU/m^3$ was theater and the most high outdoor air mean concentration of bacteria $^229 CFU/m3$was Kindergarten. The mean concentration of bacteria in the theater was higher than the IAQ standards established by the Ministry of Environment, Republic of Korea. Moreover, this study was for investigation a part of indoor air pollution condition in public facilities. It means that this study can't represent fDr all of public facilities. Therefore, we suggest that long and middle term country plan for management of IAQ should be established through long-term and continuous investigation of IAQ condition. Also above consideration in mind, it is suggest that the research for source contribution of the results on these need further study.

  • PDF

The Occupant Perception and Investigation of Indoor Air Quality at Home in Seoul

  • Sohn, Jong-Ryeul;Kim, Young-Whan;Byeon, Sang-Hoon
    • 환경위생공학
    • /
    • 제18권1호
    • /
    • pp.51-57
    • /
    • 2003
  • 최근 산업장 뿐만아니라 주택에서의 실내환경오염은 대단히 중요한 관심사이다. 특히 미국 EPA에서는 성인이 하루에 약 80 % 이상을 실내 공간에서 생활하고 있는 것으로 보고하고 있으며, 이러한 생환 방식의 변화에 인한 최근 도시화 지역에서의 실내 공기질(indoor air quality)의 문제가 새로운 환경 이슈로 부각되고 있고, 일본을 비롯한 구미 각 국에서도 21세기 환경문제 중 실내환경(indoor environment) 문제를 최우선으로 다루고 있다. 그러므로 본 연구에서는 주택에서의 실내공기질을 평가하기 위하여 설문지를 통하여 인식도를 조사하고 그를 토대로 6개의 다른 주거환경을 가진 주택을 대상으로 실내공기오염도를 측정하였다. 본 연구에서 평가한 측정항목은 온도, 습도, CO, $CO_2$, 호흡성분진, 포름알데히드, 총부유세균(TBC)이었으며, 주택의 지역 및 계절별로 나누어 측정하였는데, 측정결과 호흡성분진은 주택 5,6 에서 국내의 기준을 초과하였으며, 총부유세균은 흥콩과 싱가폴의 실내기준 권고치인 $500{\;}CFU/m^3$을 초과였고, HCHO는 모든 대상 주택에서 초과하였다. 또한 통계적으로 분석한 결과 주택의 건축년도와 CO, TBC가 0.01 수준에서 유의성 관계를 나타냈으며, 습도는0.05 수준에서 유의성을 나타냈다. 또한 주택의 거주자 500인을 대상으로 조사한 설문지 결과에서는 대부분 응답자가 실내공기오염에 대하여 인식하고있으며, 실내오염으로 인해 피로>두통>눈 아픔>기침 등을 호소하고 있으며, 실내공기정화장치가 필요하다고 응답하였다. 결론적으로 본 연구의 목적은 주택에서의 실내공기질을 평가하여 실내공기질의 중요성을 인식시키고, 그에 대한 구체적인 대책방안을 제시하여 관련 기준을 준비하는데 기초적인 자료를 마련하고 주민들이 쾌적한 삶을 유지하는데 기여하고자 한다.

사무실 근로자들의 실내공기질 인식에 관한 기초 조사 (K대학교를 중심으로) (A study on university office worker's perception of indoor air quality (Focused on K university))

  • 신은영;김광희
    • 교육녹색환경연구
    • /
    • 제16권3호
    • /
    • pp.69-76
    • /
    • 2017
  • 실내공기질(Indoor Air Quality, IAQ)은 실내에 상주하는 이용자의 심신에 영향을 주는 공기의 질이라고 정의할 수 있으며, 보통 일상생활을 영위하는 건물 내부의 공기상태이다. 과거에 비해 많은 사람들이 실내에서 거주하는 시간이 증가하였고, 생활수준이 높아짐에 따라 건강에 영향을 미치는 실내공기질에 대한 관심이 증대되고 있다. 사무실 근로자의 경우, 하루의 약 97%인 23시간 12분을 실내에서 보내는 것으로 조사되었는데, 오랜 시간 거주하는 근로자의 특성상 실내공기질은 건강뿐 아니라 업무 생산성과 효율성에도 영향을 미치는 것으로 발표되었다. 따라서 향후, 대학 사무공간의 실내공기질의 개선을 위해서는 전 세계적으로 공인된 미국의 냉동공조학회(ASHRAE)의 권고 사항처럼 1시간에 6회 이상의 공기 교환이 이루어 져야 할 것이며, 질 높은 쾌적함을 위해서 온습도 및 기류까지 고려한 환기시스템 계획이 세워져야 한다. 또 외기공기 유입을 막아 무조건적인 에너지 비용의 저감만을 강요할 것이 아니라, 적절한 환경 제공을 통해 기대되는 근로자의 의료비 절약과 생산성 향상을 통한 수익 발생 등의 요인을 고려해야 할 것이다.

시스템 에어컨 설치 공간의 실내공기질 특성에 관한 연구 (A Study on Characteristics of Indoor- Air-Quality in Interior Space Equipped with System Air-Conditioner)

  • 이상원;김종민;염승원;조대근;최재붕;김석우
    • 설비공학논문집
    • /
    • 제20권5호
    • /
    • pp.304-313
    • /
    • 2008
  • This paper investigates the indoor-air-quality (IAQ) characteristics of the interior space equipped with system air-conditioner. The behaviors of individual variables such as temperature, humidity and concentration of carbon dioxide ($CO_2$) that influence on IAQ of the interior space were characterized under various cooling conditions by numerical and experimental studies. The numerical analysis predicting the temperature behavior of the interior space was conducted, and its results showed a good agreement with the experimental ones. The $CO_2$ concentration and humidity were measured and their time dependent behaviors were monitored and analyzed. From the results, it was found that there existed the differences of the time-dependent behaviors of IAQ variables according to the locations. In addition, it is demonstrated that the large discharge angle of $45^{\circ}$ made the temperature profile more irregular and the high discharge flow of 5.34 m/s produced similar temperature profiles at three different sensing locations. Finally, the humidity of interior space was less sensitive to the changes of the air cooling conditions than the case of temperature and the $CO_2$ concentration increase mainly depended on the number of individuals inside the space.