하계 공동주택 하이브리드 환기시스템 적용에 따른 실내공기 및 열 환경 평가 (Analysis of Indoor Air & thermal environment with Hybrid Ventilation system during summer)

  • 김상진;김은수;김태연;이승복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.387-392
    • /
    • 2006
  • The recent on indoor air problem has led to many studies on the methods and effects of ventilation for better indoor air quality. Although natural ventilation is the most effective and energy-saving method in residental housings, the small size of openable window has been a problem in high-rise residential buildings to ventilate only through natural ventilation. Consequently, the installation of mechanical ventilation system has been a requirement in residential buildings, and has caused other problems such as increase of energy consumption and SBS. Hybrid ventilation which uses forces of both natural and mechanical power has been introduced to solve the problem of increase in energy consumption with natural ventilation. In this paper, two types of hybrid ventilation systems in residential building were introduced. One type was with natural ventilation through vent grille in the window, and another type was with natural ventilation through ceiling duct while both types used mechanical ventilation system with the outlets. The indoor temperature distribution and pollution density distribution in summer while operating the ceiling air conditioner were analyzed through CFD simulation. In this paper, the optimal location of diffusers to achieve thermal comfort would be proposed.

  • PDF

카페트에서 방출되는 VOCs의 방출특성 (Emission Characteristics of Volatile Organic Compounds (VOCs) from a Carpet)

  • 신동민;김창녕;김동술
    • 설비공학논문집
    • /
    • 제15권1호
    • /
    • pp.40-49
    • /
    • 2003
  • This study has been conducted to identify and quantify the emissions of Volatile Organic Compounds (VOCs) from a new carpet. The carpet sample consists of polypropylene cushion and latex backing. The VOCs have been sampled on sorbent tubes and analyzed by thermal desorption unit and GC/MSD. For over 240 hours, concentration of VOCs has been measured in a small chamber made of stainless steel. With the measured data, emission factor and mass balance have been considered. The experiments have been conducted in accordance with ASTM D5116-97. The carpet has emitted a variety of VOCs, but in this study, 7 VOCs compounds have been considered: chlorobenzene, ethylbenzene, styrene, isopropylbenzene, bromobenzene, 2-chlorotoluene, and 1,2,3-trimethylbenzene. The results show that the concentrations of VOCs and the emission factors have exponentially decayed from relatively high level to low level with time. The gradients of the concentration of VOCs and emission factors are different for various components. It is found that styrene, 2-chlorotoluene are emitted more than others with higher concentrations.

도시철도 객실 공기질 개선을 위한 롤필터 개발연구 (Development of Air Cleaning Roll-Filter for Improving IAQ in Subway)

  • 권순박;박덕신;조영민;김종범;남궁석;한태우;조관현;김태성
    • 한국철도학회논문집
    • /
    • 제14권4호
    • /
    • pp.313-319
    • /
    • 2011
  • 현대사회는 많은 교통수단이 이용되고 있으며, 그 중 수도권 도시철도는 하루 평균 721만명이 사용하는 중요한 교통수단이다. 실내공기질에 대한 관심과 PSD의 설치로 인해 터널내공기질 문제에서 객실내 공기질로 이동하고 있다. 하지만 현재 객실내 공기질 향상을 위한 장치는 전무한 상태이며 기존 에어필터 기술 적용시 설치비용과 유지보수가 문제점으로 지적되고 있다. 연구의 최종목표는 미세먼지와 이산화탄소를 효과적으로 저감시킬수 있는 독립형 청정장치를 개발하는 것이고, 본 연구에서는 미세먼지 저감기능을 수행하는 롤필터 집진 장치개발을 목적으로 한다. 객실내 롤필터 집진장치를 설치할 수 있는 공간에 대해 조사하고, 이에 따른 도시철도 객실 먼지저감에 효과적인 시스템 구조를 제시하였으며, 적정 풍량을 산정하다. 유동해석과 먼지저감효율에 대한 수치해석적 연구를 통해 최적운영 조건을 분석하였다. 그리고 롤필터에 적용가능한 필터재질에 대하여 차압특성과 입자포집효율을 평가하여 객실 유닛에 가장 적합한 필터를 선정하였다.

공동주택의 지하주차장 연결통로 및 엘리베이터 홀의 환기에 관한 실험적 연구 (An Experimental Study on Ventilation of Connection Passage and Elevator Hall of Underground Parking in the Apartment Houses)

  • 김일겸;박우철
    • 한국산학기술학회논문지
    • /
    • 제9권6호
    • /
    • pp.1523-1528
    • /
    • 2008
  • 본 논문에서는 지하주차장 연결통로 및 엘리베이터 홀의 기계식 환기장치의 설치 및 적용을 위한 기초자료를 얻기 위하여 공동주택 지하주차장에 환기장치를 설치하여 실험을 수행하였다. 엘리베이터 홀의 경우 침기 및 누기(자연환기)로 인하여 실제 환기회수는 계산환기회수의 5배 정도 크게 나타났다. 지하 주차장 연결통로 및 엘리베이터홀의 환기장치는 동시 급 배기로 설치하는 것이 좋으며, 설치가 어려울 때에는 차선책으로 급기만이라도 설치하는 것이 공기질 측면에서 좋을 것이라 판단된다. 겨울철 환기장치 가동에 따른 콜드 드래프트의 영향을 고려하여 환기장치의 급기부에 예열기를 설치하는데, 환기시스템의 가동유무 및 가동방법을 다르게 하여도 지하주차장 연결통로 및 엘리베이터 홀의 온도가 $7{\sim}8^{\circ}C$로 일정하게 유지되어 나타나므로 한국의 남부지역에서는 단순 급 배기 환기장치에 예열기를 설치하지 않아도 될 것으로 판단된다.

Photocatalysis of Low Concentration of Gaseous-Phase Benzene Using Visible-Light Irradiated N-doped and S-doped Titanium Dioxide

  • Jo, Wan-Kuen;Kim, Jong-Tae
    • Environmental Engineering Research
    • /
    • 제13권4호
    • /
    • pp.171-176
    • /
    • 2008
  • Studies on visible-light-driven photocatalysis of air pollutants at indoor air quality (IAQ) levels have been limited. Current study investigated visible-light derived photocatalysis with N-doped and S-doped titanium dioxide ($TiO_2$) for the control of benzene at indoor levels. Two preparation processes were employed for each of the two types of photocatalyst: urea-Degussa P-25 $TiO_2$ and titania-colloid methods for the N-doped $TiO_2$; and titanium isopropoxid- and tetraisopropoxide-thiourea methods for the S-doped $TiO_2$. Furthermore, two coating methods (EDTA- and acetylacetone-dissolving methods) were tested for both the N-doped and S-doped $TiO_2$. The two coating methods exhibited different photocatalytic degradation efficiency for the N-doped photocatalysts, whereas they did not exhibit any difference for the S-doped photocatalysts. In addition, the two doping processes showed different photocatalytic degradation efficiency for both the S-doped and N-doped photocatalysts. For both the N-doped and S-doped $TiO_2$, the photocatalytic oxidation (PCO) efficiency increased as the hydraulic diameter (HD) decreased. The degradation efficiency determined via a PCO system with visible-light induced $TiO_2$ was lower than that with UV-light induced unmodified $TiO_2$, which was obtained from previous studies. Nevertheless, it is noteworthy that for the photocatalytic annular reactor with the HD of 0.5 cm, PCO efficiency increased up to 52% for the N-doped $TiO_2$ and 60% for the S-doped $TiO_2$. Consequently, when combined with the advantage of visible light use over UV light use, it is suggested that with appropriate HD conditions, the visible-light-assisted photocatalytic systems can also become an important tool for improving IAQ.

폐열회수 환기시스템의 성능에 관한 실험적 연구 (An Experimental Study on Performance of Energy Recovery Ventilation System)

  • 김영수;최관수;김일수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권4호
    • /
    • pp.445-450
    • /
    • 2012
  • 가정과 같이 제한된 공간에서는 공조기의 온습도 조절이 어려워 질 수 있다. 최근에 들어서 사람들의 온습도에 대한 감성이 민감해 짐에 따라 실내 공기질에 대한 중요성이 부각되고 있다. 실내 공기질과 에너지 절약 사이의 모순을 해결 할 수 있는 방법으로 환기열회수장치를 제시하고 이러한 환기열회수 장치에 열전소자를 적용하여 온도 효율을 비교하고 시스템 능력을 검증해 보았다. 온도효율을 향상시키는데 전도성 가이드 베인과 단일 모터, 열전소자가 실험되었다. 단일 모터 사용시 23W를 절약 할 수 있었고 250 CMH의 능력을 가지는 개발된 시스템에서 통상적인 시스템과 비교해 냉방 주기 및 난방 주기에서 각각 4.01% 와 2.98%의 개선이 있었다.

서울시 일부 지하공간에서의 실내공기질에 관한 연구 (A Study on IAQ(Indoor Air Quality) for Underground Environments in Seoul)

  • 정진원;김윤신;권성안;홍승철;박원석;이상복;이홍석
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 1999년도 추계학술대회 논문집
    • /
    • pp.374-375
    • /
    • 1999
  • 오늘날 경제적 생활 환경의 개선으로 인하여 현대인의 생활에 많은 변화를 가져오고 있다. 제한된 공간에서 인간 활동은 지하생활공간이라는 새로운 활동영역을 창출하였고, 이에 따라 실내에서의 거주 시간은 더욱 증가하고 있다. 지하생활공간이라는 용어가 일반인들에게는 다소 생소하게 받아들여질 수 있지만 여기서 말하는 지하생활공간이라 함은 불특정 다수인이 이용하는 지하철, 지하상가, 지하주차장, 지하 보ㆍ차도, 지하터널 등을 말하며 개인의 생활 양식에 따라 단시간 이용하거나 또는 생활터전으로 장시간 거주할 수 있는 공간이라고 할 수 있다.(중략)

  • PDF

플라즈마 공정에 의한 Styrene 처리에 관한 성능 평가 및 부산물 동정 연구 (A Study on the Performance Evaluation and by-product of styrene decomposition by Non-thermal Plasma Processing)

  • 박정욱;전보경;최금찬
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 추계학술대회 논문집
    • /
    • pp.69-70
    • /
    • 2003
  • 최근 실내공기 질(IAQ : Indoor Air Quality)에 관한 인식이 높아지고 있으며 환경개선에 상응하는 기술 개발의 중요성이 크게 부각되고 있다. 실제 산업체에서는 여러 가스정화기술들이 오염물질제거에 이용되어 왔고, 그 한 분야인 N.T.P(Non-thermal plasma Process) 공정도 다양한 각도에서 연구가 수행되어 왔다. 그러나, 이 기술의 실용화를 위한 설계변수 개념의 연구는 부족한 실정으로, 이에 본 연구는N.T.P 공정에 의한 가스정화의 반 경험식 도출과 이를 이용한 성능 평가 고찰이 주목적이다. 또한, 반응기 통과 후 나오는 부산물을 동정하여, 차후 후단에 사용할 촉매를 결정 하고자 한다. (중략)

  • PDF

대학교 기숙사의 실내공기질 환경 개선에 관한 연구 (A Study on Environmental Improvement of Indoor Air Quality in University Dormitory)

  • 김호진;양정훈;석호태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1398-1405
    • /
    • 2008
  • As the structure, material and construction of building develop continuously, so the recent residential buildings are being large, high-rise and group. High-rise residential buildings consume a lot of energy on supplying cold and hot water. As well, high-rise residential buildings bring on discomfortable use and unexpected conditions on account of faucet outlet pressure rise and the difference of water supply pressure between top floor and bottom floor. Thus, the purpose of this study is to research on using conditions of cold and hot water supply system through survey and field measurement in high-rise residential buildings and to analyze problems.

  • PDF

실내공기질 공정시험법 중 VOCs 측정방법의 문제점 고찰 및 개선방안에 관한 연구 (Critical Evaluation of and Suggestions for the VOCs Measurement Method Established as the Korean Indoor Air Quality Standard Method)

  • 예진;정동희;백성옥
    • 한국대기환경학회지
    • /
    • 제30권6호
    • /
    • pp.586-599
    • /
    • 2014
  • During the last two decades, indoor air quality and volatile organic compounds (VOCs) have been of concern in Korean society due to their nature of potential health impacts. In order to investigate the pollution levels of VOCss in indoor environments, establishment of a solid test method for monitoring the airborne VOCss is essential. In Korea, a method based on adsorbent sampling and GC analysis coupled with thermal desorption was proclaimed as the Korea Standard Method for Indoor Air Quality Test. This study was carried out to examine some inherent problems of the VOCs measurement method. The VOCs method does not describe in detail preparing the standard samples. The standard samples may be prepared by impregnation of either liquid standard solutions or a mixture of standard gases. In this study, we investigated the optimal temperature condition for transferring the liquid standards onto a standard adsorbent tube. As a result, keeping the impregnation temperature at $250^{\circ}C$ will be recommended in regard of the boiling points of multiple target analytes and the thermal stability of the adsorbent. We also demonstrated some problems associated with handling of a syringe used for transferring the standard solutions onto the adsorbent tubes, and a best way to get rid of the syringe problems was suggested. Finally, a number of field works were conducted to evaluate the performance of adsorbent sampling methods. Comparison of different adsorbent tubes, i.e. tube packed with single sorbent (Tenax) and double sorbents (Tenax with Carbotrap), revealed that 30 to 40% differences between the two groups, implying that sampling efficiency is depending on the volatility and the strength of adsorbents. However, duplicate precisions for VOCs sampling with a same type of adsorbent and at same flow rates appeared to be satisfactory to be all within 20%, which is a quality control guideline. Distributed volume precisions were also found to be within a guideline value, 25%, although the precision was in general inferior to the duplicate precision. The Korea indoor VOCs test method should be more refined and improved in many aspects, particularly procedure and instrumentation for preparing the standard samples and specification of quality control assessment.