• Title/Summary/Keyword: indoor Plant

검색결과 255건 처리시간 0.507초

Particulate Matter Removal of Indoor Plants, Dieffenbachia amoena 'Marianne' and Spathiphyllum spp. according to Light Intensity (광량에 따른 실내식물 디펜바키아와 스파티필럼의 미세먼지 제거능)

  • Kwon, Kei-Jung;Park, Bong-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • 제46권2호
    • /
    • pp.62-68
    • /
    • 2018
  • This study investigated the effect of light intensity on the removal of particulate matter by Dieffenbachia amoena 'Marianne' and Spathiphyllum spp.. An acrylic chamber ($600{\times}800{\times}1200mm$, $L{\times}W{\times}H$) modeled as an indoor space and a green bio-filter ($495{\times}495{\times}1000mm$, $L{\times}W{\times}H$) as an air purification device were made of acrylic. The removal of particulate matter PM10 and PM1, the photosynthetic rate, stomatal conductance, and number of stomata of Dieffenbachia amoena 'Marianne' and Spathiphyllum spp. were measured according to three different levels of light intensity (0, 30 and $60{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}PPFD$). Regarding the length of time taken for PM10 to reach $1{\mu}g$, the Dieffenbachia amoena 'Marianne' showed a significant difference according to the presence or absence of light, and there was no significant difference shown between light intensity of 30 and $60{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}PPFD$. As for the Spathiphyllum spp., there was no significant difference between 0 and $30{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}PPFD$, while a significant difference was shown at $60{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}PPFD$. After 90 minutes, the PM1, PM10, and $CO_2$ residuals of the Spathiphyllum spp. were lowest at $60{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}PPFD$. The remaining amount of PM1 and PM10 was lower with the Spathiphyllum spp. than with the Dieffenbachia amoena 'Marianne', even at $0{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}PPFD$. With both plants, the higher the light intensity, the higher the photosynthetic rate, while the stomatal conductance did not show any significant difference. Spathiphyllum spp. showed a higher photosynthetic rate and stomatal conductance and a greater number of stomata than Dieffenbachia amoena 'Marianne', and stomata were observed in both the front and back sides of the leaves. The air purification effect of Spathiphyllum spp. is considered to be better than Dieffenbachia amoena 'Marianne' at the same light intensity due to such plant characteristics. Therefore, in order to select effective indoor plants for the removal of particulate contamination in an indoor space, the characteristics of plants such as the photosynthetic rate and the number and arrangement of stomata according to indoor light intensity should be considered.

Estimation of Soil Cooling Load in the Root Zone of Greenhouses (온실내 근권부의 지중냉각부하 추정)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • 제11권4호
    • /
    • pp.151-156
    • /
    • 2002
  • Root zone cooling, such as soil or nutrient solution cooling, is less expensive than air cooling in the whole greenhouse and is effective in promoting root activity, improving water absorption rate, decreasing plant temperature, and reducing high temperature stress. The heat transfer of a soil cooling system in a plastic greenhouse was analyzed to estimate cooling loads. The thermal conductivity of soil, calculated by measured heat fluxes in the soil, showed the positive correlation with the soil water content. It ranged from 0.83 to 0.96 W.m$^{[-10]}$ .$^{\circ}C$$^{[-10]}$ at 19 to 36% of soil water contents. As the indoor solar radiation increased, the temperature difference between soil surface and indoor air linearly increased. At 300 to 800 W.m$^{-2}$ of indoor solar radiations, the soil surface temperature rose from 3.5 to 7.$0^{\circ}C$ in bare ground and 1.0 to 2.5$^{\circ}C$ under the canopy. Cooling loads in the root zone soil were estimated with solar radiation, soil water content, and temperature difference between air and soil. At 300 to 600 W.m$^{-2}$ of indoor solar radiations and 20 to 40% of soil water contents,46 to 59 W.m$^{-2}$ of soil cooling loads are required to maintain the temperature difference of 1$0^{\circ}C$ between indoor air and root zone soil.

A Study on the Reduction of Volatile Organic Compounds by Fatsia japonica and Ardisia pusilla (팔손이와 산호수에 의한 휘발성유기화합물 저감효과에 관한 연구)

  • Song, Jeong Eun
    • KIEAE Journal
    • /
    • 제12권4호
    • /
    • pp.77-82
    • /
    • 2012
  • This study conducted the experiment of reduction of Volatile Organic Compounds(VOCs) and Formaldehyde concentration by Native plants, Fatsia japonica and Ardisia pusilla. The two plants are advantageous in that they are highly available as they grow wild, and being easy to get. Fatsia japonica is a plant of its wide and large leaf diverged 7 or 8 parts, which is thought to have a high effect of air purification. Ardisia pusilla has a smaller leaf than Fatsia japonica, which is characterized by more leaves and beautiful. Field measurements were performed using Fatsia japonica and Ardisia pusilla which were verified as air-purifying plants in Korea. The effect of reducing the concentration of VOCs and Formaldehyde by plant studied in a full scale mock-up model. The dimensions of the two models were equal. The concentration of Benzene, Toluene, Ethylbenzene, Xylene, Stylene, Formaldehyde were monitored, since they were known as most toxic materials. The concentration of VOCs was monitored three hours after the plants were placed and three days after the plants were placed. Field measurements were performed in models where the plants were placed and were not. As a result, they had all an effect of reducing pollution. In all cases of experiment of planting and growing volume, the more planting volume, the more excellent the effect. Toluene was more effective in Fatsia japonica and Ardisia pusilla planted, Formaldehyde was more effective in Fatsia japonica planted respectively. In planting and growing and placing experiment, the placement at sunny spot was more effective than that at scattered growing. When Fatsia japonica was placed at sunny spot, the reduction effect of Formaldehyde was the most excellent, and when Ardisia pusilla was placed at sunny spot, the reduction effect of Toluene was the most effective.

Studies on Effects of Interior Plantscaping as Related to the Air Ions (공기이온으로 본 실내녹화 효과에 관한 연구)

  • Kim, Tae-Soon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • 제6권3호
    • /
    • pp.1-8
    • /
    • 2003
  • This study was carried out in order to investigate of effects of environmental conditions which influence negative ions development. Negative ions are nature' most powerful air-cleaning agents, are created by nature, and found at their most optimal levels where the air is most pure and healthy. Negative ions are regarded as one of the important factors which indicate the quality of the air. Therefore, the focus of this study was to clear relationship among negative ions development induced by plant cultivar and environmental conditions such as air temperature, light intensity and relative humidity. As the results of this study, it was found that negative ions development was promoted during the period with plants compared to the period without plants. In Particular, negative ions development was high under air temperature $20^{\circ}C$, relative humidity 90% and dark condition. Temperature and humidity factors on this experiment was strongly affected on negative ions development, but light intensity had almost slight effect. It was shown that these results can contribute to the application of environmental control techniques to negative ions. Among plant cultivar of Spathiphyllum spp. Mentha spicata, and Cupressu arizonica, Mentha spicata was higher negative ions than the other plants, and also the leaves were higher than the stems and roots. The effect of plants on the perception of the inte끼r air quality may, therefore, be one explanation of this results about negative ions. on the other hand, it seems that a green indoor environment might be an increase in general well-being due to the plants.

A Super-resolution TDOA estimator using Matrix Pencil Method (Matrix Pencil Method를 이용한 고분해능 TDOA 추정 기법)

  • Ko, Jae Young;Cho, Deuk Jae;Lee, Sang Jeong
    • Journal of Navigation and Port Research
    • /
    • 제36권10호
    • /
    • pp.833-838
    • /
    • 2012
  • TDOA which is one of the position estimation methods is used on indoor positioning, jammer localization, rescue of life, etc. due to high accuracy and simple structure. This paper proposes the super-resolution TDOA estimator using MPM(Matrix Pencil Method). The proposed estimator has more accuracy and is applicable to narrowband signal compared with the conventional cross-correlation. Furthermore, its complexity is low because obtained data directly is used for construction of matrix unlike the MUSIC(Multiple Signal Classification) which is one of the well-known super-resolution estimator using covariance matrix. To validate the performance of proposed estimator, errors of estimation and computational burden is compared to MUSIC through software simulation.

Evaluation for Fundamental Properties of Concrete mixed with Pyroclastic Flow Deposit (화쇄류 퇴적물을 혼입한 콘크리트의 기초특성 평가)

  • Choi, Hyeong-Gil;Kim, Gyu-Yong;Noguchi, Takafumi
    • Journal of the Korea Concrete Institute
    • /
    • 제28권1호
    • /
    • pp.49-57
    • /
    • 2016
  • The aim of this study was to investigate the fundamental properties of pyroclastic flow deposit (PFD), and evaluate the fresh and strength properties of concrete mixed with PFD by indoor tests. The fresh properties, strength properties, shrinkage properties, and durability of the concrete mixed with PFD were also evaluated by outdoor plant tests. the harmful alkali-silica reaction did not occur by mixing concrete with PFD. ages. Moreover, no difficulty was found to be associated with concrete manufacture in the plant because no change in air contents and noticeable slump loss occurred by mixing concrete with PFD. The strength properties, shrinkage properties, and durability of the concrete mixed with PFD were also compared with those of normal concrete. With a suitable temperature control and curing method of concrete, the concrete mixed with PFD is considered to be useful in the construction material field.

Analysis of Growth Indicators of Applied Plants by AHU(Air Handling Unit)-linking with Artificial Soil-based Vegetation Bio-filters (인공토양기반 식생바이오필터의 AHU(Air Handling Unit) 연계를 통한 적용식물의 생육지표 분석)

  • Kim, Tae-Han;Lee, So-Dam;An, Byung-Ryul
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • 제21권3호
    • /
    • pp.99-110
    • /
    • 2018
  • Compared to yellow dust coming from China or particulate matter created naturally in spring due to Total Suspended Particulate(TSP), particulate matter in winter season have much more serious effect on human body as they penetrate cell membranes. Although such particulate matter are becoming a social issue, there are no concrete plans on how to reduce them. Air-purifying plants are limited in maintaining the indoor air quality of large area because it is usually difficult to quantify their performance. In order to improve this, a bio-filter that can be connected to air conditioner is suggested as an option. This study seeks to improve air conditioning model-based monitoring method for bio-filters from prior studies and objectify correlations between applied vegetation and growing environment into quantitative indicators. By doing so, this study seeks to provide criteria on plants applied to artificial soil-based vegetation bio-filters and basic information to set air-conditioning features. The study results confirmed significant tendency on the growing stability of each purifying plant in mechanical air-conditioning environment. Among three models selected for bio-filter vegetation models, epipremnum aureum showed high performance in quantitative indicators, including soil moisture, EC, and leaf temperature, etc., indicating that it would assure the highest growing stability in this test air-conditioning environment.

Study on Emission Control for Precursors Causing Acid Rain (VI) : Suitability of Aquatic Plant Biomass as a Co-combustion Material with Coal

  • Hauazawa, Atsushi;Gao, Shidong;Sakamoto, Kazuhiko
    • Asian Journal of Atmospheric Environment
    • /
    • 제2권2호
    • /
    • pp.102-108
    • /
    • 2008
  • In China, energy and environmental problems are becoming serious owing to rapid economic development. Coal is the most problematic energy source because it causes indoor and outdoor air pollution, acid rain, and global warming. One type of clean coal technology that has been developed is the coal-biomass briquette (or bio-briquette, BB) technique. BBs, which are produced from pulverized coal, biomass (typically, agricultural waste), and a sulfur fixation agent (slaked lime, $Ca(OH)_2$) under high pressure without any binder, have a high sulfur-fixation effect. In addition, BB combustion ash, that is, the waste material, can be used as a neutralization agent for acidic soil because of its high alkalinity, which originates from the added slaked lime. In this study, we evaluated the suitability of alternative biomass sources, namely, aquatic plants, as a BB constituent from the perspective of their use as a source of energy. We selected three types of aquatic plants for use in BB preparation and compared the fuel, handling, and environmental characteristics of the new BBs with those of conventional BBs. Our results showed that air-dried aquatic plants had a higher calorific value, which was in proportion to their carbon content, than agricultural waste biomass; the compressive strength of the new BBs, which depends on the lignin content of the biomass, was high enough to bear long-range intracontinental transport in China; and the new BBs had the same emission control capacity as the conventional BBs.

An Investigation on Influence of Vibration Noise in Cooling Tower on Precision Equipments (산업용 냉각탑의 진동소음이 정밀장비에 미치는 영향에 대한 연구)

  • Lee, Jin-Kab
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제17권9호
    • /
    • pp.369-374
    • /
    • 2016
  • Cooling towers have been installed on rooftops or outside of buildings and widely applied to control the indoor temperature in residential areas and buildings. However, the noise and vibration resulting from their operation may cause problems in adjacent buildings. The purpose of this study is to measure the noise and vibration of an industrial cooling tower located adjacent to industrial plants and to investigate its influence on the surroundings according to an authorized evaluation standard. Further, in order to measure the effect of the vibration of the tower on the precision equipment inside the plant, an experiment is conducted to measure the vibration of the ground in the plant and the targeted precision equipment. The measurement results indicate that the noise in the cooling tower is 4 to 9 dB(A) higher than the maximum level defined in the standard of 68dB(A). The effect of the vibration of the tower on the precision equipment is comparatively minimal, because that in the supporting frame of the building is weaker than that on the floor where the precision equipment is located. The vibration of the floor on.

Differences on Growth of Two Quercus Species according to Indoor Light Intensity (자생 참나무속 2종의 실내 광량에 따른 생육 차이)

  • Park, Kyungtae;Lee, Cheol Hee;Oh, Chan-Jin;Cho, Ju Sung
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 한국자원식물학회 2019년도 추계학술대회
    • /
    • pp.58-58
    • /
    • 2019
  • 본 연구에서는 자생 참나무속 2종의 몇 가지 저광량 조건하에서 생육 및 엽록소 형광 반응을 조사하였다. 연구의 재료는 참가시나무(Quercus salicina Blume)와 붉가시나무(Q. acuta Thunb.)의 2년생 실생묘를 사용하였다. 다양한 실내 광환경조건을 조사하여 광량을 10, 50, 100 및 200 PPFD (${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$)로 설정하였으며, 실험기간 동안 광주기(12/12 h), 온도($25{\pm}1^{\circ}C$) 및 습도($55{\pm}3%$)를 동일하게 설정하여 총 8주간 재배하였다. 대조구는 유리온실에서 동일기간 동안 재배된 식물을 사용하였다. 연구의 결과, 참가시나무는 50 PPFD 이하에서 전체 식물 중 50%가 잎이 마르며 떨어지는 경향을 보였으며, 100 PPFD에서도 25%의 잎마름이 관찰되었다. 200 PPFD는 줄기직경을 제외한 초장, 엽수, 엽장, 엽폭 및 엽록소 함량(SPAD)이 대조구와 유사하거나 높았으며, 엽록소 형광 반응에서도 모든 측정값이 대조구와 유의한 차이를 보이지 않았다. 붉가시나무는 50 PPFD 이상의 광량에서는 줄기직경, 엽수, 엽장 및 SPAD가 대조구와 유사하거나 높은 결과를 보였으나, 모든 광량조건에서 초장과 엽폭이 대조구에 비해 유의적으로 낮았다. 엽록소 형광 반응은 모든 광량에서 대조구와 비슷한 양상을 보였으나, 10 PPFD는 초기형광값(Fo)과 비광학적 에너지의 손실(DIo/RC)이 대조구에 비해 유의적으로 낮은 결과를 보였다.

  • PDF