• Title/Summary/Keyword: indocyanine green(ICG)

Search Result 42, Processing Time 0.025 seconds

Indocyanine Green Excretion Test in Korean Black Goats (한국 흑염소에 있어서 Indocyanine Green 배설시험)

  • Lee Sung-Yub;Lee Chang-Woo
    • Journal of Veterinary Clinics
    • /
    • v.4 no.2
    • /
    • pp.473-481
    • /
    • 1987
  • This experiment was performed in order to establish a proper method to determine the half life of indocyanine green(ICG T$\frac{1}{2}$) and its fractional clearance rate(KICG) and investigate the applicability of indocyanine green ( ICG ) excretion test in hepatotoxicity experiment in Korean black goats. The results were as follows : 1. Maximum absorbance of ICG in plasma was at 810 nm in this experiment. 2. The coefficient of correlation between the results obtained by standard method and potassium cyanide method was 0.99 and the regression equation between two methods was y=0.9996 x+0.0065. 3. As the disappearance curve of ICG plotted in semi-log graph revealed linear pattern at least for 6 minutes after injection, the postinjection blood samples were decided to collect at 2 and 6 minutes after ICG injection. 4. ICG T$\frac{1}{2}$ and KICG values were not affected by dose level of ICG. 5. When 0.25 mg of ICG per kg body weight was administered the normal data of ICG T$\frac{1}{2}$ and KICG in Korean black goa were 1.468${\pm}$0.197 minutes(mean${\pm}$SD) and 0.482${\pm}$0.076/minutes respectively. 6. After administration of carbon tetracholride. the ICG T$\frac{1}{2}$ started to increase acutely from day 1, revealed the peak at day 3, and then returned almostly but not completely to preinjection level at day 14. The ICG T$\frac{1}{2}$ value was suggested to be a sensitive indicator of hepatic injury in Korean black goats.

  • PDF

Indocyanine green excretion test and changes of plasma enzyme activities in Korean native cattle and dairy cattle (한우 및 유우에서의 indocyanine green 배설시험 및 혈장효소 활성치의 변화)

  • Son, Min-soo;Kim, Cheol-ho;Choi, IL-kwan;Kim, Jin-gu;Hur, Ju-hyeong;Kang, Chung-boo
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.4
    • /
    • pp.677-681
    • /
    • 1992
  • This experiment was carried out to establish a proper method of indocyanine green(ICG) excrection test for a applicable liver function test in three Korean native cattle average weighing about 450kg and dairy cattle parity of 3~5. The results obtained the half life($T^1/_2$), fractional clearance rate(KICG), retention rate and plasma enzyme activities before or after injection of ICG were as follows. 1. The maximum absorbance of ICG in plasma was at 805nm. 2. Average half life and fractional clearance rate following the injection of ICG 0.25mg/kg body weight were $5.53{\pm}1.27$ minute and $0.131{\pm}0.031$/minute in Korean native cattle, $4.55{\pm}0.68$ minute and $0.156{\pm}0.031$/minute in dairy cattle, respectively. The ICG removal rate was exponentially liner for the first 15 minutes after injection both of Korean native cattle and dairy cattle. 3. Average plasma retention rate when 10, 15, 30 minutes after injection was $35.7{\pm}13.9$, $23.2{\pm}7.1$, $10.8{\pm}3.5%$ in Korean native cattle, $26.8{\pm}3.3$, $14.2{\pm}1.2$, $5.5{\pm}2.2%$ in dairy cattle, respectively. 4. Plasma enzyme activities(AST, ALT, r-GTP) were no variation among the before, during and after injection of ICG. From these results, ICG excretion test to cattle is applicable to evaluation of liver funtion in both clinical and research, and adopted the 15 minutes plasma sample as the sample taken at the ideal time for comparative purposes.

  • PDF

Effect of Photothermal Therapy with Indocyanine Green in Multispecies Biofilm (Indocyanine Green을 이용한 광열 치료의 다종 우식원성 바이오필름에 대한 효과)

  • Kim, Myunghwan;Park, Howon;Lee, Juhyun;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.21-30
    • /
    • 2021
  • The purpose of this study is to investigate the antibacterial effects of indocyanine green (ICG) and near-infrared diode lasers on multispecies biofilms. Multispecies biofilms of Streptococcus mutans, Lactobacillus casei and Candida albicans were treated with different irradiation time using photosensitizer ICG and 808 nm near-infrared diode laser. Colony forming unit (CFU) was measured, and qualitative evaluation of biofilm was performed with confocal laser scanning microscopy (CLSM). Temperature measurement was conducted to evaluate photothermal effect. In the groups using ICG and diode laser, reduction in CFU was statistically significant, but the difference in antibacterial effect on L. casei and C. albicans with irradiation time was not significant, and similar results were confirmed with CLSM. Groups with ICG and diode laser showed higher temperature elevation than groups without ICG, and results of measured temperature were similar to the range of hyperthermia. In conclusion, ICG and near-infrared diode laser showed antibacterial effects on multispecies biofilms, but studies on protocol are necessary for clinical application.

Effect of Cimetidine on the Hepatic Blood flow -On the Basis of Pharmacokinetics of Indocvanine Green in Rats- (시메티딘이 간혈류량에 미치는 영향 - Rat에 있어서 Indocyanine Green의 체내 동태를 중심으로 -)

  • Lee, Yong-Bok;Koh, Ik-Bae
    • Korean Journal of Clinical Pharmacy
    • /
    • v.3 no.2
    • /
    • pp.163-168
    • /
    • 1993
  • The influence of cimetidine pretreatment(100mg/kg, single i.p.) on the hepatic blood flow was investigated using pharmacokinetic parameters of indocyanine green(ICG) in the rat on the basis of hepacc perfusion-limited model. ICG(1mg/kg) was respectively administered via femoral and portal vein to the control and to the cimetidine-pretreated rats. The rate constant K12, K20 and the systemic clearance(CLt) of ICG were significantly(p<0.05) decreased ill the cimetidine-pretrea-to(B rats, but no significant diffirences were observed in hematocrit and liver weight. The biliary excretion rates of ICG were also decreased regardless of the route of administration in the cimetidine-pretreated rats. And also the hepatic blood flow in rats was decreased about $16\%$ by cimetidine. It may be concluded that the decreased hepatic blood flow with cimetidine mainly contributed to the decreased hepatic uptake and the decreased systemic clearance of ICG.

  • PDF

Short-Wave Infrared Fluorescence-Guided Surgery Using Indocyanine Green in a Dog with a Cutaneous Mast Cell Tumor

  • Su-Hyeon Kim;Sungin Lee
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.395-399
    • /
    • 2022
  • A 6-year-old spayed, female golden retriever dog was presented with a skin mass on the dorsal region of the right carpus. The cytology result of the region revealed characteristics of mast cell tumors (MCTs). Short wave-infrared fluorescence-guided surgery using Indocyanine green (ICG) was performed to determine the surgical margin of the tumor. ICG was injected intravenously 24 hours before the surgery and the patient was hospitalized and carefully monitored. During the surgery, ICG fluorescence-based surgery was performed to identify the tumor and the surgical margin. The tumor was visible, and the skin mass was resected using NIR device for the guidance of the surgical margin of the tumor. Once the resection was complete, the surgical site was again inspected with SWIR fluorescence imaging to identify residual tumor cells. The resected tumor, using ICG navigation, was classified as low-grade cutaneous MCT and the margin was complete on the histopathological result. We report herein a case of resection of a cutaneous MCT in a dog using SWIR fluorescence imaging ICG which can be potentially used for the identification of tumors and evaluation of the surgical margin for complete resection.

Value of Indocyanine Green Videoangiography in Deciding the Completeness of Cerebrovascular Surgery

  • Moon, Hyung-Sik;Joo, Sung-Pil;Seo, Bo-Ra;Jang, Jae-Won;Kim, Jae-Hyoo;Kim, Tae-Sun
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.349-355
    • /
    • 2013
  • Objective : Recently, microscope-integrated near infrared indocyanine green videoangiography (ICG-VA) has been widely used in cerebrovascular surgery because it provides real-time high resolution images. In our study, we evaluate the efficacy of intraoperative ICG-VA during cerebrovascular surgery. Methods : Between August 2011 and April 2012, 188 patients with cerebrovascular disease were surgically treated in our institution. We used ICG-VA in that operations with half of recommended dose (0.2 to 0.3 mg/kg). Postoperative digital subtraction angiography and computed tomography angiography was used to confirm anatomical results. Results : Intraoperative ICG-VA demonstrated fully occluded aneurysm sack, no neck remnant, and without vessel compromise in 119 cases (93.7%) of 127 aneurysms. Eight clipping (6.3%) of 127 operations were identified as an incomplete aneurysm occlusion or compromising vessel after ICG-VA. In 41 (97.6%) of 42 patients after carotid endarterectomy, the results were the same as that of postoperative angiography with good patency. One case (5.9%) of 17 bypass surgeries was identified as a nonfunctioning anastomosis after ICG-VA, which could be revised successfully. In the two patients of arteriovenous malformation, ICG-VA was useful for find the superficial nature of the feeding arteries and draining veins. Conclusion : ICG-VA is simple and provides real-time information of the patency of vessels including very small perforators within the field of the microscope and has a lower rate of adverse reactions. However, ICG-VA is not a perfect method, and so a combination of monitoring tools assures the quality of cerebrovascular surgery.

In Vivo Enhanced Indocyanine Green-Photothermal Therapy for a Subconjunctival Tumor

  • Kim, Chang Zoo;Lee, Sang Joon;Hwang, Sang Seok;Chae, Yu-Gyeong;Kwon, Daa Young;Ko, Taek Yong;Kim, Jun Hyeong;Jung, Min Jung;Masanganise, Rangarirai;Oak, Chulho;Ahn, Yeh-Chan
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.311-321
    • /
    • 2021
  • Indocyanine green (ICG) is a dye approved for use in clinical diagnostics. ICG remains in the intravascular space following intravenous administration, due to its ability to rapidly bind to the plasma proteins, and its therapeutic potential has been studied in well-vascularized cutaneous tumors. Here we have evaluated the clinical response of a subconjunctival tumor to photothermal therapy (PTT) using an ICG-enhanced near-infrared diode laser and its adverse effects, in a rabbit. 22 male New Zealand white rabbits with subconjunctival tumors were enrolled (control group 6, laser-only group 8, laser-with-ICG group 8). Rabbits in the laser-with-ICG group received ICG (twice, 2 mg/kg each time, intravenously) directly followed by irradiation with a diode laser (λ = 810 nm). Rabbits in the laser-only group were irradiated with the diode laser. ICG angiography, ultrasonography, and pathologic examination were performed to evaluate PTT response at specific time points (0, 2, and 4 weeks after PTT). Two weeks after initial treatment, the eight rabbits treated by laser with ICG showed a 100% response rate. There was no clinical response in both laser-only and control groups. ICG-PTT is a potential and effective palliative therapeutic modality for subconjunctival tumors.

Indocyanine green excretion test and changes of plasma enzyme activites in dogs (개에서의 indocyanine green 배설시험 및 혈장효소 활성치의 변화)

  • Kim, Cheol-ho;Choi, Il-kwan;Son, Min-soo;Kim, Jin-gu;Kang, Chung-boo
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.4
    • /
    • pp.671-675
    • /
    • 1992
  • This experiment was carried out to establish a proper method of indocyanine green(ICG) excretion test for a applicable liver function test in dogs. The half life(T1/2), fractional clearance rate(KICG) and retention rate after injection of ICG with or without administred carbon tetrachloride($CCl_4$) were also invested. The results obtained were as follows ; 1. The maximum absorbance of ICG in plasma was at 810nm. 2. Half life and fractional clearance rate when administered 0.25 and 0.50mg of ICG per Kilogram body weight were $6.33{\pm}0.58$ minutes and $0.11{\pm}0.99$/minute in the former, $10.01{\pm}1.0$ minutes and $0.07{\pm}0.007$/minute in the latter, respectively. The ICG removal rate was exponentially linear for the first 15 minutes after injection both, of 0.25 and 0.50mg of ICG. 3. One day following the administration of $0.0042m{\ell}\;CCl_4$ kilogram body weight which injected 0.50mg of ICG, half life was more longer and fractional clearance rate was significantly reduced than that of ICG single injection. 4. Plasma retention rate when 15, 30, 45 minutes after injection dose of 0.25 and 0.50mg ICG per Kilogram body weight, $14.7{\pm}4.8$, $5.1{\pm}3.1$, $2.6{\pm}1.6%$ in the former, $26.9{\pm}1.8$, $11.1{\pm}2.4$, $4.8{\pm}1.3%$ in the latter, respectively. However, after administration of $CCl_4$, plasma retention rate of ICG at a dose of 0.50mg, it was $39.3{\pm}0.9$, $16{\pm}2.9$, $10.7{\pm}0.1%$, respectively. 5. Plasma enzyme(AST, ALT, r-GTP) activities administered with $CCl_4$ were increased, but there was no change which injected any dose of single ICG injection. From these results, ICG excretion test to dog is applicable to evaluation of liver function in both clinical and research.

  • PDF

Study of Optimal Conditions Affecting the Photothermal Effect and Fluorescence Characteristics of Indocyanine Green

  • Seo, Sung Hoon;Bae, Min Gyu;Park, Hyeong Ju;Ahn, Jae Sung;Lee, Joong Wook
    • Current Optics and Photonics
    • /
    • v.5 no.5
    • /
    • pp.554-561
    • /
    • 2021
  • Indocyanine green (ICG) is a cyanine dye that has been used in medical diagnostics based on fluorescence imaging, and in medical therapy based on the photothermal effect. It is important to systematically understand the photothermal effect and fluorescence characteristics of ICG simultaneously. By varying a number of conditions such as laser power density, laser irradiation wavelength, concentration of ICG solution, and exposure time of laser irradiation, the intensity properties of fluorescence and the temperature change induced by the photothermal effect are measured simultaneously using a charge-coupled-device camera and a thermal-imaging camera. The optimal conditions for maximizing the photothermal effect are determined, while maintaining a relatively long lifetime and high efficiency of the fluorescence for fluorescence imaging. When the concentration of ICG is approximately 50 ㎍/ml and the laser power density exceeds 1.5 W/cm2, the fluorescence lifetime is the longest and the temperature induced by the photothermal effect rapidly increases, exceeding the critical temperature sufficient to damage human cells and tissues. The findings provide useful insight into the realization of effective photothermal therapy, while also specifying the site to be treated and enabling real-time treatment monitoring.

Endoscopic Fluorescence Angiography with Indocyanine Green : A Preclinical Study in the Swine

  • Cho, Won-Sang;Kim, Jeong Eun;Kim, Sae Hoon;Kim, Hee Chan;Kang, Uk;Lee, Dae-Sic
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.6
    • /
    • pp.513-517
    • /
    • 2015
  • Objective : Microscopic indocyanine green (ICG) angiography is useful for identifying the completeness of aneurysm clipping and the preservation of parent arteries and small perforators. Neuroendoscopy is helpful for visualizing structures beyond the straight line of the microscopic view. We evaluated our prototype of endoscopic ICG fluorescence angiography in swine, which we developed in order to combine the merits of microscopic ICG angiography and endoscopy. Methods : Our endoscopic ICG system consists of a camera, a light source, a display and software. This system can simultaneously display real-time visible and near infrared fluorescence imaging on the same monitor. A commercially available endoscope was used, which was 4 mm in diameter and had an angle of $30^{\circ}$. A male crossbred swine was used. Results : Under general anesthesia, a small craniotomy was performed and the brain surface of the swine was exposed. ICG was injected via the ear vein with a bolus dose of 0.3 mg/kg. Visible and ICG fluorescence images of cortical vessels were simultaneously observed on the display monitor at high resolution. The real-time merging of the visible and fluorescent images corresponded well. Conclusion : Simultaneous visible color and ICG fluorescent imaging of the cortical vessels in the swine brain was satisfactory. Technical improvement and clinical implication are expected.