• 제목/요약/키워드: indirect flux estimation

검색결과 32건 처리시간 0.021초

A Novel Position Sensorless Speed Control Scheme for Permanent Magnet Synchronous Motor Drives

  • Won, Tae-Hyun;Lee, Man-Hyung
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제2B권3호
    • /
    • pp.125-132
    • /
    • 2002
  • PMSMS (permanent magnet synchronous motors) are widely used in industrial applications and home appliances because of their high torque to inertia ratio, superior power density, and high efficiency. For high performance control, accurate informations about the rotor position is essential. Sensorless algorithms have lately been studied extensively due to the high cost of position sensors and their low reliability in harsh environments. A novel position sensorless speed control for PMSMs uses indirect flux estimation and is presented in this paper. Rotor position and angular velocity are estimated by the proposed indirect flux estimation. Linkage flux and magnetic field flux are calculated by the voltage equations and the measured phase current without any integration. Instead of linkage flux calculation with integral operation, indirect flux and differential magnetic field are used for the estimation of rotor position. A proper rejection technique fur current noise effect in the calculation of differential linkage flux is introduced. The proposed indirect flux detecting method is free from the integral rounding error and linkage flux drift problem, because differential linkage flux can be calculated without any integral operation. Furthermore, electrical parameters of the PMSM can be measured by the proposed TCM (time compression method) for soft starting and precise estimation of rotor position. The position estimator uses accurate electrical parameters that are obtained from the proposed TCM at starting strategy. In the operating region, a proper compensation method fur temperature effect can compensate fir the estimation error from the variation of electrical parameters. The proposed novel position sensorless speed control scheme is verified by the experimental results.

공간전압 벡터제어를 통한 유도전동기의 새로운 벡터제어성능연구 (A new vector control performance for induction motor with SVPWM)

  • 변윤섭;장동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2246-2248
    • /
    • 2001
  • This paper presents a new vector control scheme for induction motor. An exact knowledge of the rotor flux position is essential for a high-performance vector control. The position of the rotor flux is measured in the direct schemes and estimated in the indirect schemes. Since the estimation of the flux position requires a priori knowledge of the induction motor parameters, the indirect schemes are machine parameter dependent. The rotor and stator resistance among the parameters change with temperature. Variations in the parameters of induction machine cause deterioration of both the steady state and dynamic operation of the induction motor drive. Several methods have presented to minimize the consequences of parameter sensitivity in indirect scheme. In this paper, new estimation scheme of rotor flux position is presented to eliminate sensitivity due to variation in the resistance. The simulation is executed to verify the proposed vector control performance and to compare its performance with that of indirect and direct vector control.

  • PDF

Indirect Detection of Rotor Position of Switched Reluctance Motor Based on Flux Linkage Analytic Model

  • Zhou, Yongqin;Hu, Bo;Wang, Hang;Jin, Ningzhi;Zhou, Meilan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.829-837
    • /
    • 2018
  • In this paper, a flux linkage model based on four magnetization curves fitting is proposed for three-phase 12/8 switched reluctance motor (SRM), with the analysis of the basic principle of flux detection method and function analysis method. In the model, the single value function mapping relationship between position angle and flux is established, which can achieve a direct estimation of rotor position. The realization scheme of SRM indirect position detection system is presented. It is proved by simulation and experiment that the proposed scheme is suitable for rotor position detection of SRM, and has high accuracy of position estimation.

새로운 유도전동기 벡터제어 기법 (A new vector control method for induction motor)

  • 변윤섭;왕종배;백종현;박현준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.680-687
    • /
    • 2000
  • In this paper we present a new vector control scheme for induction motor. An exact knowledge of the rotor flux position is essential for a high-performance vector control. The position of the rotor flux is measured in the direct scheme or estimated in the indirect schemes. Since the estimation of the flux position requires a priori knowledge of the induction motor parameters, the indirect schemes are machine parameter dependent. The rotor resistance and stator resistance among the parameters change with temperature. Variations in the parameters of induction machine cause deterioration of both the steady state and dynamic operation of the induction motor drive. Several methods have been presented to minimize the consequences of parameter sensitivity in indirect scheme. In this paper new estimation scheme of rotor flux position is presented to eliminate sensitivity due to resistance change with temperature. Simulation results are used to verify the performance of the proposed vector control scheme.

  • PDF

회전자와 고정자 저항 변동에 영향을 받지 않는 유도전동기의 새로운 벡터제어 기법 (A new vector control approach for induction motor without influence of rotor resistance and stator resistance variation)

  • 변윤섭;백종현;왕종배;박현준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2371-2373
    • /
    • 2000
  • This paper presents a new vector control scheme for induction motor. An exact knowledge of the rotor flux position is essential for a high-performance vector control. The position of the rotor flux is measured in the direct scheme and estimated in the indirect schemes. Since the estimation of the flux position requires a priori knowledge of the induction motor parameters, the indirect schemes are machine parameter dependent. The rotor and stator resistance among the parameters change with temperature. Variations in the parameters of induction machine cause deterioration of both the steady state and dynamic operation of the induction motor drive. Several methods have presented to minimize the consequences of parameter sensitivity in indirect scheme. In this paper, new estimation scheme of rotor flux position is presented to eliminate sensitivity due to variation in the resistance. The simulation is executed to verify the proposed vector control performance and to compare its performance with that of indirect vector control.

  • PDF

유도전동기의 회전자저항 변동 보상을 위한 슬립주파수의 적응 조정 (Slip Frequency Andative Tunning for the Compensation of Rotor Resistance Variation of Induction Motor)

  • 이일형;이윤종
    • 한국안전학회지
    • /
    • 제9권4호
    • /
    • pp.42-48
    • /
    • 1994
  • A rotor flux error-based approach for correcting the rotor time constant estimation used in the slip frequency calculator of indirect field oriented controller is presented in this paper. The controller was derived from the d-q induction machine model. Slip frequency gain is dependent on the machine parameter errors. And parameter errors result in rotor flux error. Thus, estimated rotor flux is compared to commanded rotor flux. The error between them is used for the estimation of rotor time constant. Simulation results which demonstrate the performance of this approach are presented.

  • PDF

유도전동기의 통일적 벡터제어에 관한 연구 (A Study on Unified Vector Control of Induction Motor)

  • 김영대;이동철
    • 동력기계공학회지
    • /
    • 제5권3호
    • /
    • pp.95-103
    • /
    • 2001
  • This study is applied to common induction motor, and vector control is realized by using an indirect type of induction motor which has a simple composition. In this study extended Kalman filter is used from control theoretical viewpoint, and primary resistance and secondary resistance which change according to the temperature of motor are simultaneously estimated. This paper aims to research an indirect vector control in which the secondary resistance obtained from this estimation is consistent with secondary flux. This estimation is made by on-line estimation, but on-line estimation is difficult because extended Kalman filter takes long time in computation time. So off-line estimation was made on the assumption that the variation of temperature in motor is slow temporally.

  • PDF

속도제어를 위한 유도전동기 자속추정 시뮬레이터 적용에 관한 연구 (A Study on the Flux Estimation Simulator Application for the Induction Motor Speed Control)

  • 황락훈;나승권;최기호
    • 한국산학기술학회논문지
    • /
    • 제12권3호
    • /
    • pp.1289-1301
    • /
    • 2011
  • 본 논문에서는 전 속도 영역에서 안정적인 자속추정이 가능한 유도전동기 자속추정방법을 제안 하였다. 제안된 방법은 전압, 전류, 속도 등의 정보를 통하여 자속각을 연산하는 유도전동기 직접벡터제어방식을 이용하였다. 유도전동기 벡터제어에 있어서 자속정보는 필수적이기 때문에 정확한 자속을 추정하기 위한 방법으로 저속영역에서 는 전류모델 자속 추정기를, 고속영역에서는 전압모델 자속 추정기를 각각 이용함으로써 전 속도영역에서 정확한 자속을 추정할 수 있었다. 또한 기본적인 속도, 전류, 자속제어기는 PI제어기를 이용하였으며, 각각의 적분에 의한 오차를 보상하기 위하여 Anti-windup PI 제어기를 추가하였다. 제시한 제어기의 타당성을 알아보고자 Matlab / simulink를 이용하여 전류모델, 전압모델 자속 추정기를 설계하여 정확한 자속추정이 이루어짐을 확인하였으며, 유도 전동기 벡터제어 시 간접벡터와 직접벡터방식의 파라미터 영향에 따른 분석을 통해 보다 정밀한 제어가 이루어짐을 확인하였다. 이와 같은 시뮬레이션 결과를 분석 하여 제시한 알고리즘의 타당성을 입증하였다.

슬라이딩 모드 관측기에 의한 유도전동기 센서리스 벡터제어 (Sensorless Indirect Vector Control of Induction Motor using Sliding Mode Observer)

  • 신종렬;권순만;이종무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.340-342
    • /
    • 2005
  • This paper describes the speed-sensorless vector control system of a three-phase induction motor using sliding mode flux/speed observer. The sliding mode observer estimates the rotor speed. The error between the actual and observed currents converges to zero which guarantees the accuracy of the flux observer. The convergence of nonlinear time-varying observer along with the asymptotic stability of the controller was analyzed. To define the control action which maintains the motion on the sliding manifold, an "equivalent control" concept was used. It was simulated and implemented on a sensorless indirect vector drive for 750[W] three-phase induction motor. The simulation and experimental results demonstrated the effectiveness of the proposed estimation method.

  • PDF

비선형 관측기에 의한 유도전동기 간접 벡터제어 (Indirect Vector Control of Induction Motor using Nonlinear Observer)

  • 정삼용;이진섭;서진연;김동휘;최연옥;조금배
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.366-370
    • /
    • 1998
  • Indirect vector control for induction motors requires the use of observers for estimation or observation of rotor flux magnitude and position. In this paper, authors discribe the induction motor vector control and introduce a nonlinear observer, named ELO(extended Luenberger Observer), without simulation results as a preliminary work for trial application. Normally, design of nonlinear observer need coordinate transfromation and linearization through solving the partial different equation. However, ELO requires minimal solution of nonlinear partial differential equation. Simulation was performed by under the enviroment of Matlab and Simulink without the proposed observer because we are still working. Simulation was performed with conventional flux observer, a dc-ac inverter by SVPWM technique, a vector controller armed with multiple PI controllers

  • PDF