• 제목/요약/키워드: indirect composite

검색결과 115건 처리시간 0.026초

중합 조건에 따른 간접복합레진의 굴곡강도 (Flexural strength of indirect composite resin with different polymerization conditions)

  • 금영희;김부섭
    • 대한치과기공학회지
    • /
    • 제35권4호
    • /
    • pp.333-341
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the flexural strength of indirect composite resins with different polymerization conditions. Methods: Ten specimens ($2mm{\times}2mm{\times}25mm$) of each composite resins (Tescera (T), Gradia (S) and Sinfony (S)) were fabricated by two polymerization methods : manufacturers's and light heat pressure. Composite resins polymerized by manufacturers's method and light heat pressure served as control (TS, GS and SS) and experimental groups (TE, GE and SE), respectively. The composite resins were tested for flexural strength and the surface of composite resins were observed with scanning electron microscope (SEM) under X1,000 magnification. Results: The flexural strength values of cured composite resin decreased in the following order: TE (195.4MPa), TS (179.8MPa), GE (169.9MPa), SE (137.7MPa), SS (111.1MPa) and GS (100.9MPa) groups. Conclusion: The flexural strength values between the control and the experimental groups were not significantly different although experimental groups showed higher flexural strength values than control groups.

법랑질에 의한 수종의 간접복합레진의 마모에 관한 연구 (AN IN-VITRO WEAR STUDY OF INDIRECT COMPOSITE RESINS AGAINST HUMAN ENAMEL)

  • 이현정;전영찬;정창모;정희찬
    • 대한치과보철학회지
    • /
    • 제45권5호
    • /
    • pp.611-620
    • /
    • 2007
  • Statement of problem: Second-generation indirect composite resins have been improved flexural strength, compressive strength, hydrolytic degradation resistance, wear resistance compared to first-generation indirect composite resins, but there are still some problems as hydrolysis and low wear resistance. Some manufacturers claim that wear resistance of their materials has been improved, but little independent study has been published on wear properties of these materials and the properties specified in the advertising materials are largely derived from in-house or contracted testing. Purpose: This study was to evaluate the wear of indirect composite resins (SR Adore, Sinfony, Tescera ATL) and gold alloy against the human enamel. Material and method: Extracted human incisors and premolars were sectioned to $2{\times}2{\times}2mm$ cube and embedded in the clear resin and formed conical shaped antagonist to fit the jig of pin-on-disk tribometer. Total 20 antagonists were stored in distilled water. Five disk samples, 24mm in diameter and 1.5mm thick, were made for each of three groups of indirect composite resins and gold alloy group, and polished to #2,000 SiC paper on auto-polishing machine. Disk specimens were tested for wear against enamel antagonists. Wear test were conducted in distilled water using a pin-on-disk tribometer under condition (sliding speed 200rpm contact load 24N, sliding distance 160m). The wear of the enamel was determined by weighing the enamel antagonist before and after test, and the weight was converted to volumes by average density. The wear tracks were analyzed by scanning electron microscopy and surface profilometer to elucidate the wear mechanisms. Statistical analysis of the enamel wear volume, wear track depth and wear tract width of disk specimens were accomplished with one-way ANOVA and the means were compared for significant differences with Scheffe's test. Results: 1. The enamel wear was most in gold alloy, but there were no statistically significant differences among all the groups (P>.05). 2. In indirect composite resin groups, the group to make the most shallow depth of wear tract was Sinfony, followed by Tescera ATL, SR Adoro (P<.05). Gold alloy was shallower than Sinfony, but there was no statistically significant difference between Sinfony and gold alloy (P>.05). 3. The width of wear tract of SR Adore was larger than the other groups (P<.05), and there were no statistically significant differences among the other groups (P>.05). 4. SEM analysis revealed that Sinfony and gold alloy showed less wear scars after test, Tescera ATL showed more wear scars and SR Adore showed the most. Conclusion: Within the limits of this study, Sinfony and gold alloy showed the least wear rates and showed similar wear patterns.

직접법과 간접법으로 수복한 복합레진의 1년간의 임상적인 평가 (1 YEAR FOLLOW-UP STUDY OF DIRECT AND INDIRECT COMPOSITE RESTORATIONS)

  • 박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.284-289
    • /
    • 2002
  • Background : The purpose of the present study was to evaluate the direct and indirect composite restorations which had been placed for 1 year Methods : The composite restorations which had been placed between 1999. Mar and 1999, Dec was evaluated after 1 year For direct restorations. Spectrum (Dentsply, USA) and Z100 (3M, USA) were used in the anterior teeth and Surefil (Dentsply, USA) were used. For class V restorations of anterior and posterior teeth. Spectrum was used. For indirect restorations, Targis/Vectris system (Vivadent/Ivoclar, Liechtenstein) was used 2 examiners evaluated marginal quality, proximal contact. discoloration, presence of 2$^{nd}$ caries, loss of filling and hypersensitivity of restorations. The restorations was clinically evaluated by modified methods based on USPHS. Results : 60 teeth were evaluated. 59 were clinically acceptable and 1 restoration which was placed in class v cavity in the posterior tooth was fallen out. In most cases, the restorations were clinically accept-able. For restorations which had been directly placed in the class II cavities, loose proximal contact was indicated as the main complaints. Conclusions : Most of Anterior and posterior restorations which bad been directly or indirectly placed for 1 year were clinically acceptable. For posterior teeth, loose proximal contact was indicated as the main problem in the directly placed Class II restorations. Long term clinical study is needed.

복합재 주익 무인항공기의 낙뢰보호 설계와 피격영역 해석 (Protection Design and Lightning Zone Analysis for Unmanned Aerial Vehicle with Composite Wings)

  • 우희채;김용태
    • 한국군사과학기술학회지
    • /
    • 제26권3호
    • /
    • pp.302-312
    • /
    • 2023
  • This paper describes the analysis of lightning strike zoning, the indirect lightning data simulation and the protection design for lightning indirect effects of equipment by lightning strike for unmanned aircraft consisting of composite wings. Through the analysis of lightning strike zoning according to the external shape of unmanned aerial vehicles, the structure areas that should be protected during lightning strike is derived, and the protection requirements of lightning indirect effects for flight critical equipments and equipment that must be operated upon lightning strike was derived. Lightning protection levels according to the location of mounting equipment and surrounding structure materials for each equipment was derived, and the protection design of the unmanned aerial vehicle with composite structures was also proposed from direct effect of lightning. Later, the lightning protection technology will be verified by the ground test of lightning direct and indirect effects.

Techniques and Characteristics of Indirect Restorations

  • Cho, Kyung-Mo
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.593-593
    • /
    • 2001
  • Esthetic restoration techniques can be categorized into "Direct techniques" consist only of intraoral procedures and "Indirect techniques" include intraoral as well as extraoral laboratory steps. Those made extraorally exhibit generally enhanced esthetic potential and anatomy and better hardness and wear resistance, indirect esthetic restorations numerously applied in contemporary dentistry. Indirect restorative materials can be divided into two categories; composite resin-based materials and ceramic-based materials. These materials shows various were resistance, modulus of elasticity, repair postenital, chemical stability, and different laboratory procedures. In this session, benefit of indirect techinques, case selection of this kind of restorations, and material characteristics and fabrication produre of those materials will ber reviewed; Targis, Sculpture, Belleglass, and Post-curing of restorative composite resins in resin-based materials; Dicor, Empress, Cerec, Celay, and conventional firing porcelain in ceramic based materials.

  • PDF

4종의 간접법용 복합 레진의 기계적 특성 비교 (COMPARISON OF MECHANICAL PROPERTIES IN 4 INDIRECT COMPOSITE RESIN)

  • 김길수;윤태호;송광엽;안승근
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.21-33
    • /
    • 2007
  • Statement of problem: The esthetic component of dental care has become increasingly more important, while new tooth-colored materials are continually marketed. Various new indirect composite materials have been developed with required advantages. The most recent development in the indirect composites has been the introduction of the second-generation laboratory composite or poly-glass materials. They are processed by different laboratory techniques based on combinations of heat, pressure, vacuum and light polymerization. Although, second generation products became available in 1995, their characteristics and clinical performance have not been adequately investigated. Purpose: The aim of this study was to measure the mechanical properties of the second generation indirect resin system and compare these with an existing universal direct composite resin. Material and method: In this study four indirect composite material (Adoro LC, BelleGlass HP, Tescera, Synfony) were tested for flexural strength, wear resistance, hardness and their degree of conversion against Z250, a light cure direct composite. Results: Within the limitations of this study, the following conclusions were drawn: 1. From the abrasion wear result, Adoro showed the least volume loss while Synfony showed the greatest volume loss. Z250 and BelleGlass HP didn't show significant difference (p>0.05), but they showed significant difference with other groups (p<0.05). From the attrition wear, BelleGlass HP showed the least volume loss and it didn’t show significant difference with Tescera (p>0.05). While Synfony showed the greatest volume loss that it showed significant difference with other groups (p>0.05). 2. Mean values of flexural strength by means of three point bending test was in the order of Z250, Adoro, Belleglass HP, Tescera and Synfony. Mean elastic modulus was in the order of Z250, BelleGlass HP, Tescera, Adoro and Synfony. 3. The result of Vicker‘s microhardness value showed that significantly higher value in Z250 (p<0.05), and is in the order of BelleGlass HP, Tescera, Adoro and Synfony. 4. The degree of conversion measured by FT-IR showed significantly higher value in BelleGlass HP (p<0.05), and is in the order of Adoro, Synfony, Tescera and Z250. Conclusion: Significant differences were found in the flexural strength, wear resistance, hardness and their degree of conversion.

표면처리에 따른 금속과 간접복합레진간의 전단결합강도 비교연구 (Comparison of shearbond strength between metal and indirect resin according to the different conditionings)

  • 최수영;최현민;문홍석;심준성;박영범;이근우
    • 대한치과보철학회지
    • /
    • 제55권3호
    • /
    • pp.264-271
    • /
    • 2017
  • 목적: 본 연구에서는 4종의 간접복합레진에 대하여 금합금과 Ni-Cr합금에 대한 결합강도의 차이와 각각의 합금에 표면형태를 다르게 하여 일정한 온도의 증류수에 보관 전과 후에 전단결합강도의 차이가 있는지 알아보고자 하였다. 재료 및 방법: 금속 시편을 주조 제작하였는데, 금합금과 Ni-Cr합금의 표면형태를 flatting, bead, loop로 하여 4종의 간접복합레진(Gradia, Tescera Sinfony and in;joy)당 60개씩 총 240개를 준비하였다. 이후 금속표면에 각각의 제조사에서 지시한대로 간접 복합레진을 접착하였다. 간접복합레진의 중합 24시간 후에 만능시험기를 이용하여 전용 지그에 금속시편을 부착 후, 전단결합강도를 측정하였다. 또한 증류수에 240시간 보관 후에 같은 방법으로 전단결합강도를 측정하였다. 결과: 금속의 표면 형태에 따른 전단결합강도 측정에서 4종의 레진 모두 bead군에서 높은 결합강도를 보였고 loop, flatting 순이었다 (P < .05). 수조에서 240시간 보관 후에는 Gradia가 모든 군에서 다른 레진 군에 비해 비슷하거나, 통계적으로 유의하게 높은 (P < .05) 전단결합강도를 나타내었다. 결론: 금속표면의 형태에 따라, 금속의 종류에 따라, 물속 보관 전후에 따라 금속과 간접복합레진의 결합력의 차이를 나타내었고 추가 실험을 통해 최적의 조합에 따른 임상에서의 적용가능성을 보여주었다.

TARGIS & VECTRIS SYSTEM을 이용한 심미적 수복 (Esthetic Restoration Using Targis & Vectris System)

  • 최현식;황정원;신상완;서규원
    • 대한심미치과학회지
    • /
    • 제7권1호
    • /
    • pp.18-26
    • /
    • 1998
  • The improvement of esthetic dentistry has been accelerated from the development of composite resin and dentin-enamel adhesive since 1980's. The indirect composite resin restorations have more accurate proximal contact point and occlusal form than direct restoration. And the side effect of resin shrinkage is minimal because the amount of composite used in oral cavity is limited in cement space. As a results, marginal leakage, hypersensitivity, secondary caries, and discoloration are significantly diminished. The first generation laboratory composite resin used in indirect resin restoration had been widespread in 1980's and the second generation laboratory composite resins were developed in 1990's. The second generation laboratory composite resins are called Ceramic Polymer. The physical properties of Ceramic Polymer are improved because of high content of inorganic filler, and the esthetics and biocompatibility are better than that of the first generation resin. So the application range using composite resin have been broadened. The purpose of this paper is to introduce Targis & Vectris system that is classified to second generation laboratory composite and to report several cases in which the system was utilized for restoration.

  • PDF

3종의 간접수복용 복합레진의 굴곡강도 비교 및 표면관찰 (Evaluation of Flexural strength and surface porosity of three indirect composite resins)

  • 김준태;박진영;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.9-16
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate flexural strength, composite surface and fractured surface of three different indirect composite resins. Methods: Fifteen bar-shaped specimens ($25mm{\times}2mm{\times}2mm$) were fabricated for each FL group (Flow type and Light curing) and PLP group (Putty type and Light, Pressure curing) and PL group (Putty type and Light curing) according to manufacturer's instructions and ISO 10477. Fabricated specimens were stored in the distilled water for 24 hours at the temperature of $37^{\circ}C$. Three-point bending strength test was performed to measure flexural strength using universal testing machine at a crosshead speed of 1mm/min (ISO 10477). Surface and fractured surface of specimens were observed by digital microscope. Results were analyzed with Kruskal-wallis tests (${\alpha}=0.05$). Results: Mean (SD) of three different indirect composite resins were 83.38 (6.67) MPa for FL group, 139.90(16.53) MPa for PLP group and 171.72(16.74) MPa for PL group. Flexural strength were statistically significant (p<0.05). Differences were not observed at fractured surface among three groups. However, many pores over $100{\mu}m$ were observed at PL group in observing surface of specimen. Conclusion: Flexural strength of composite resins was affected by second polymerization method and content of inorganic filler.