• 제목/요약/키워드: increasing rate of power generation

검색결과 106건 처리시간 0.025초

용접흄 충 금속함량 변화에 관한 연구 (A Study on the Content Variation of Metals in Welding Fumes)

  • 윤충식;박동욱;박두용
    • 한국환경보건학회지
    • /
    • 제28권2호
    • /
    • pp.117-129
    • /
    • 2002
  • Concentration of welding fumes and their components is known to be hazardous to welder and adjacent worker. To determine the generation rates of metals in fumes, $CO_2$ flux cored arc welding on stainless steel was performed in well designed fume collection chamber. Variables were different products of flux cored wire(2 domestic products and 4 foreign products) and input energy(low-, optimal- , high input energy). Mass of welding fumes was determined by gravimetric method(NIOSH 0500 method), and 17 metals were analysed by inductively coupled plasm-atomic emission spectroscopy(NIOSH 7300 method). Flux cored wire tube and flux were analysed by scanning electron microscopy to determine their metal composition. 17 metals were classified by their generation rates. Generation rates of iron, manganese, potassium and sodium were all above 50mg/min at optimal input energy level. Generation rates of chromium and amorphous silica were 25~50mg/min. At 1~25mg/min level, nickel, titanium, molybdenum, and aluminum were included. Copper, zinc, calcium, lead, magnesium, lithium, and cobalt were generated below 1 mg/min. Generation rates of metal components in fumes were influenced by input energy, types of flux cored wire. Flux cored wire was consisted of outer shell tube and inner flux. Iron, chromium, and nickel were the major components of outer tube. Flux contained iron, chromium, nickel, potassium, sodium, silica, and manganese. The use of flux cored wire can increase the hazards by increasing the amounts of fumes formed relative to that of solid wire. The reason might be the direct transfer of elements from the flux, since the flux is fine power. Ratio of metals to the fume of flux cored wire was lower than that of solid wire because non-metal components of flux were transferred. Total metal content of fumes in flux cored arc welding was 47.4(24.3~57.2) percent that is much lower than that of solid wire, 75.9 percent. We found that generation rates of iron, manganese, chromium and nickel, all well known to cause work related disease to welder, increased more rapidly with increasing input energy than those of fumes. To reduce worker exposure to fumes and hazardous component at source, further research is needed to develop new welding filler materials that decrease both the amount of fumes and hazardous components.

넓은 출력 범위를 갖는 CMOS line driver에 관한 연구 (A study of SMOS line driver with large output swing)

  • 임태수;최태섭;사공석진
    • 전자공학회논문지S
    • /
    • 제34S권5호
    • /
    • pp.94-103
    • /
    • 1997
  • It is necesary that analog buffer circuit should drive an external load in the VLSI design such as switched capacitor efilter (SCF), D/A converter, A/d converter, telecommunicatin circuit, etc. The conventional CMOS buffer circuit have many probvlems according as CMOS technique. Firstly, Capacity of large load ar enot able to opeate well. The problem can be solve to use class AB stages. But large load are operated a difficult, because an element of existing CMOS has a quadratic functional relation with inptu and outut voltage versus output current. Secondly, whole circuit of dynamic rang edecrease, because a range of inpt and output voltages go down according as increasing of intergration rate drop supply voltage. In this paper suggests that new differential CMOS line driver make out of operating an external of large load. In telecommunication's chip case transmission line could be a load. It is necessary that a load operate line driver. The proposal circuit is planned to hav ea high generation power rnage of voltage with preservin linearity. And circuit of capability is inspected through simulation program (HSPICE).

  • PDF

Assessment of electricity demand at domestic level in Balochistan, Pakistan

  • Urooj, Rabail;Ahmad, Sheikh Saeed
    • Advances in Energy Research
    • /
    • 제5권1호
    • /
    • pp.57-64
    • /
    • 2017
  • Electricity is basic need for country development. But at the present time proper planning and policy is require at high pace for power generation network extension due to the increasing population growth rate. Present study aimed to analyze the present and future demand for electricity at household level in Province of Balochistan of Pakistan via simulation modeling. Data of year 2004-2005 was used as baseline data for electricity consumption to predict future demand of electricity at both rural and urban domestic level up to subsequent 30 years, with help of LEAP software. Basically three scenarios were created to run software. One scenario was Business-As-Usual and other two were green scenarios i.e., solar and wind energy scenarios. Results predicted that by using alternative energy sources, demand for electricity will be fulfill and will also reduce burden on non-renewable energy sources due to the greater potential for solar and wind energy present in Balochistan.

파키스탄 파트린드댐의 저수지 퇴사관리를 위한 배사효과 분석 (Analysis of Sediment Flushing Effect for Reservoir Sedimentation Management of the Patrind Dam in Pakistan)

  • 노준우;박진혁;허영택;김상호
    • 한국물환경학회지
    • /
    • 제29권6호
    • /
    • pp.799-807
    • /
    • 2013
  • Reservoir sedimentation is one of the major concerns for sustainable reservoir operation. Since sediment concentration of the rivers in the Himalayan Mountain is very high, a proper sediment management scheme is necessary. This paper presents long-term reservoir sedimentation and sediment flushing based on the gate operation. Focused on the reservoir to be constructed for the Patrind hydropower project in Pakistan, 4 different flushing scenarios were proposed in this study to prevent successive sedimentation. By extending flushing period and by increasing the flushing discharge for 2 times, the flushing rate increases up to 53.2% and 43.6% in proportion to flushing period and discharge, respectively. Based on the simulation presented in this paper, it is expected to establish efficient sediment management plan to increase hydro power generation and sediment flushing simultaneously.

독립형 태양광 발전 시스템의 무정전 전력공급을 위한 시스템 용량 최적 선정에 관한 연구 (A Study on the Optimal System Sizing of the Standalone Photovoltaic Power Generation System for Uninterruptible Power Supply)

  • 김기영;최우진
    • 전력전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.77-85
    • /
    • 2018
  • Renewable energy has been increasingly used and widely acclaimed as one of the solutions to rampant environmental problems. Among numerous kinds of renewable sources, the penetration rate of the PV system is relatively higher than that of others due to ease of installation. However, one disadvantage of the PV system is its dependence on weather condition. The PV system is especially critical when it is used for standalone systems because it cannot operate when the power generated from a PV module is not enough. Therefore, PV systems are often used with an energy storage system, such as batteries, to store backup energy when the weather condition is insufficient to supply power to the system. Blackout time can be reduced by increasing the size of the energy storage system, but it is a trade-off with system cost. In this work, optimal sizing of a standalone PV system is proposed to supply power to the system without blackout. The sizing of PV modules and batteries is performed by a simulation based on actual irradiation data collected during the past five years. The Life cycle costing of each system is evaluated to determine an optimal set of PV modules and batteries among several different combinations. The standalone PV system designed by the proposed method can supply power to the system with no interruption as long as the weather condition is similar to those of the past five years.

이류체 노즐을 이용한 유전체장벽방전 플라즈마 가스의 OH 라디칼 생성 향상 (Enhancement of OH Radical Generation of Dielectric Barrier Discharge Plasma Gas Using Air-automizing Nozzle)

  • 박영식
    • 한국환경과학회지
    • /
    • 제27권8호
    • /
    • pp.621-629
    • /
    • 2018
  • Many chemically active species such as ${\cdot}H$, ${\cdot}OH$, $O_3$, $H_2O_2$, hydrated $e^-$, as well as ultraviolet rays, are produced by Dielectric Barrier Discharge (DBD) plasma in water and are widely use to remove non-biodegradable materials and deactivate microorganisms. As the plasma gas containing chemically active species that is generated from the plasma reaction has a short lifetime and low solubility in water, increasing the dissolution rate of this gas is an important challenge. To this end, the plasma gas and water within reactor were mixed using the air-automizing nozzle, and then, water-gas mixture was injected into water. The dissolving effect of plasma gas was indirectly confirmed by measuring the RNO (N-Dimethyl-4-nitrosoaniline, indicator of the formation of OH radical) solution. The plasma system consisted of an oxygen generator, a high-voltage power supply, a plasma generator and a liquid-gas mixing reactor. Experiments were conducted to examine the effects of location of air-automizing nozzle, flow rate of plasma gas, water circulation rate, and high-voltage on RNO degradation. The experimental results showed that the RNO removal efficiency of the air-automizing nozzle is 29.8% higher than the conventional diffuser. The nozzle position from water surface was not considered to be a major factor in the design and operation of the plasma reactor. The plasma gas flow rate and water circulation rate with the highest RNO removal rate were 3.5 L/min and 1.5 L/min, respectively. The ratio of the plasma gas flow rate to the water circulation rate for obtaining an RNO removal rate of over 95% was 1.67 ~ 4.00.

50kW급 계통연계형 태양광발전시스템의 시뮬레이터 구현 (Implementation of the 50kW Utility Interconnected Photovoltaic System Simulator)

  • 정병호;박정민;조금배;백형래;정수복
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.21-27
    • /
    • 2005
  • This paper summarizes the results of these efforts by offering a photovoltaic system structure in 50kW middle scale applications installed in Cho-sun University dormitory roof. The combination of photovoltaic system components are interconnected and system monitoring system will be summarized for the purpose of the increasing safety in this article. This paper describes configuration of utility interactive photovoltaic system which generated electric power supplies to dormitory. In order to installing the middle or large scale photovoltaic system, It must investigated the optimal design of system, compute quantity of power generation, economic rate of return and so on. In this paper represent 50kW utility photovoltaic system examination and developed simulation results. The performance of photovoltaic system has been evaluated and analyzed with simulation. The results obtained in this research will be much useful to prior investigation for installing utility interactive photovoltaic system.

50kw급 PV시스템 시뮬레이터의 구현 및 경제성 분석에 관한 연구 (Implementation of the 50kW Utility Interconnected PV System Simulator and the Study of Financial Analysis)

  • 이강연;김용구;신석두;김형곤;전형석;김병철;민완기;김남오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 정기총회 및 학술대회 전문대학교육위원
    • /
    • pp.157-159
    • /
    • 2008
  • This paper summarizes the results of these efforts by offering a photovoltaic system structure in 50kW. The combination of photovoltaic system components are interconnected and system monitoring system will be summarized for the purpose of the increasing safety in this article. This paper describes configuration of utility interactive photovoltaic system which generated electric power supplies to dormitory. In order to installing the middle or large scale photovoltaic system, It must investigated the optimal design of system, compute quantity of power generation, economic rate of return and so on. In this paper represent 50kW utility photovoltaic system examination, developed simulation results and financial analysis. The performance of photovoltaic system has been evaluated, analyzed with simulation and financial analysis results. The results obtained in this research will be much useful to prior investigation for installing utility interactive photovoltaic system.

  • PDF

고주파 유도결합 플라즈마의 전자에너지 분포 계측 (II) (Measurement of Electron Energy Distribution of the Radio-Frequency Inductively Coupled Plasma)

  • 황동원;하장호;전용우;최상태;박원주;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1803-1805
    • /
    • 1998
  • Electron temperature, electron density and electron energy distribution function were measured in Radio-Frequency Inductively Coupled Plasma(RFICP) using a probe method. Measurements were conducted in argon discharge for pressure from 10 mTorr to 40 mTorr and input rf power from 100W to 600W and flow rate from 3 sccm to 12 sccm. Spatial distribution electron temperature and electron density and electron energy distribution function were measured for discharge with same aspect ratio(R/L=2). Electron temperature was found to depend on pressure, but only weakly on power. Electron density and electron energy distribution function strongly depended on both pressure and power. Electron density and electron energy distribution function increased with increasing flow rate. Radial distribution of the electron density and electron energy distribution function were peaked in the plasma center. Normal distribution of the electron density electron energy distribution function were peaked in the center between quartz plate and substrate. These results were compared to a simple model of ICP, then we found out the generation mechanism of Radio-Frequency Inductively Coupled Plasma.

  • PDF

대형병원에서 마이크로터빈 이용한 열병합시스템 에너지성능 및 경제성 분석 (The Energy Performance & Economy Efficiency Evaluation of Microturbine Installed in Hospital buildings)

  • 김병수;길영욱;홍원표
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.176-183
    • /
    • 2009
  • 대형병원의 에너지 소비패턴을 분석한 후 마이크로가스터빈을 적용할 경우 기존 시스템 대비 냉난방에너지 절감량 및 전기에너지 절감량과 경제성분석을 통해 대형병원의 에너지 소비량을 절감하기 위한 에너지성능평가 모의연구를 수행하였다. 0.5[MW]급 마이크로 가스터빈을 설치한 후 에너지 성능분석을 한 결과 터빈에서의 발전효율은 30[%]이며, 전기는 건물에서 사용되는 조명에너지 뿐만 아니라 전체 전기에너지의 40[%]을 절감할 수 있는 것으로 분석되었다. 또한 터빈에서 발전되는 전기량과 배열을 냉난방에너지원으로 이용할 경우 전체 시스템효율은 70[%]로 상승할 뿐만 아니라 난방에너지의 56[%], 냉방에너지의 67[%]를 절감할 수 있는 것으로 분석되었으며 현가등가법에 의한 시스템 투자회수 기간이 약 9년으로 분석되었다.