• Title/Summary/Keyword: increase treatment efficiency

Search Result 899, Processing Time 0.028 seconds

Characteristics of COD Removal in the Electrolytic Treatment of Dyeing-Wastewater (전기분해에 의한 염색폐수의 COD 제거 특성)

  • 강광남;윤용수
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.2
    • /
    • pp.139-146
    • /
    • 1998
  • The characteristics of color and COD removal for dyeing-wastewater using electrochemical reaction were investigated. >From the result, the removal efficiency of color and COD were increased with increase of temperature, decrease of electrode distance, increase of electrolyte concentration and increase of potential and these were obtained above 99%, above 75% within 30 min, individually. Cause of higher COD removal efficiency, it is more suitable that dyeing-wastewater is treated by electrolytic treatment prior to biological treatment. It is concluded that the electrolytic treatment of dyeing-wastewater can be used as the effective and economical method in practical treatment.

  • PDF

The Investigation of COD Treatment and Energy Consumption of Urban Wastewater by a Continuous Electrocoagulation System

  • DEDE SAGSOZ, Yesim;YILMAZ, Alper Erdem;EKMEKYAPAR TORUN, Fatma;KOCADAGISTAN, Beyhan;KUL, Sinan
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.261-268
    • /
    • 2022
  • In this study, electrochemical treatment of urban wastewater with electrical conductivity of 1000 μS cm-1 and chemical oxygen demand of 250 mg L-1 was investigated using the variables of initial pH value, current density and flow rate. Electrocoagulation was used, in which aluminum and stainless steel were selected, as the electrochemical treatment process. The electrocoagulation process was operated in continuous mode. The data obtained in experimental studies show that the best COD removal efficiency occurred in experiments where the initial pH value was 6. The increase in current density from 5 A to 15 A decreased the removal efficiency from 79 to 67%. The increase in flow rate under constant current density also reduced the efficiency of removal as expected. In experiments in which current density and flow rate were examined together, the increase in flow rate allowed the application of higher current densities. This situation led to considerable reductions in energy consumption values, even if the COD removal efficiency did not significantly increase. The high COD removal obtained with the use of high flow rate and high current density indicates that the electrocoagulation process can be used for high flow rate municipal wastewater treatment.

Analysis of Light Traits in a Solar Light-collector Device and its Effects on Lettuce Growth at an Early Growth Stage (태양광 집광장치의 광 특성분석 및 유묘기 상추의 생장에 미치는 영향)

  • Lee, Sanggyu;Lee, Jaesu;Won, Jinho
    • Journal of Environmental Science International
    • /
    • v.28 no.11
    • /
    • pp.1019-1025
    • /
    • 2019
  • The aim of this study was to analyze the light traits in a solar light-collector device and its effects on lettuce growth at an early growth stage. The three hyper parameters used were the reflector diameter (2 cm and 4 cm), coating inside the reflector (chrome-coated, non-coated) and distance from the light fiber (15 cm and 20 cm). The results showed that light efficiency, which is the ratio of light intensity inside the fiber to the solar intensity, improved by 41.1 % when using a 2 cm diameter chrome-coated reflector at a distance of 15 cm from the light fiber; whereas it only improved by 20.6% when a non-coated reflector was used. As the reflector size was increased to 4 cm, the light efficiency for the coated and non-coated reflectors increased by 28.5 % and 26.4 %, respectively, hence, no significant difference was observed. When the light fiber was placed at a distance of 20 cm, the increase in light efficiency with coating treatment was 8 % higher than without coating treatment. We also compared the efficiency of light-fiber treatment with that of LED treatment in our lettuce nursery, and observed that the plants exhibited better growth with light-fiber treatment. We observed an average increase of 1.7 cm in leaf height, $7cm^2/plant$ increase in leaf area, and 32 mm increase in root length upon light-fiber treatment as opposed to those observed with LED treatment. These findings indicate that the collector light-fiber is economically feasible and it improves lettuce growth compared with the LED treatment.

A Study on the Treatment of Wastewater Containing Surfactants (계면활성제를 함유한 폐수의 효율적 처리 방법에 관한 연구)

  • Shin, Myoung-Ok;Chung, Moonho
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.3
    • /
    • pp.109-120
    • /
    • 1997
  • The purpose of this study is to evaluate the effectiveness of wastewater treatment containing surfactant. For that, comparative analysis of effectiveness of Featon Oxidation, Aluminum Sulfate, PAC (Poly Aluminum Chloride) on the treatment of the synthetic wastewater containing LAS (Linear Alkyl Sulfate), a main component of the commercial detergent was carried. Then, the optimum pH, the dosage of reagents, and the concentration of the LAS in each treatment were determined. The results of the study were summarized as following. 1. In Fenton Oxidation, optimal pH was 3 and 97.92% removal of LAS was achieved. However, the increase of the pH reduced the efficiency of LAS removal. The proper chemical dosages of FeSO$_4$ and $H_2O_2$ were 300 mg/l and the increase of dosages didn't affected the removal efficiency. Therefore, it was concluded that the economic chemical dosage was 300 mg/l of FeSO$_4$ and $H_2O_2$. 2. In case of Alum treatment, optimal pH was 11 with 61.13% removal efficiency. At other pH range, the removal efficiency was very low indicating that removal efficiency is greatly influenced by pH. The proper chemical dosage was 200 mg/l with the removal efficiency of 77.65%. The increase of chemical dosage, however, reduced the removal efficiency. 3. In case of using PAC, optimal pH was 6 with 97.99% removal efficiency. The result showed that wastewaters containing surfactant were almost completely removed at pH 6 by PAC. Removal efficiency was decreased by increasing PAC dosage higher than 400 mg/l and dosage over 700 mg/l of PAC abolished the treatment. 4. The comparative analysis of three methods revealed that the effective pH ranges were at pH 2-5 with Fenton oxidation, at pH 6-11 with PAC, and pH 11 with Alum. The removal efficiencies at these pH were 83.95-97.92%, 75.98-97.99% and 61.13%, respectively. 5. Increase in LAS concentration reduced the removal efficiencies of all three methods. In the case of PAC or Alum treatment, treatment abolished at LAS concentration higher than 700 mg/l.

  • PDF

Effect of Ozonation Consistency on the Ink Removal Efficiency and Pulp Characteristics (오존 처리농도가 ONP의 탈묵 효율 및 펄프 특성에 미치는 영향)

  • 조병묵;원종명
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.3
    • /
    • pp.18-23
    • /
    • 2001
  • The effect of pulp consistency on the deinking properties in the ozone deinking of ONP was investigated in order to develop the environmentally friendly deinking method. The pulp consistency and ozone treatment time were varied for this purpose. Higher pulp consistency during ozone treatment gave better ink removal efficiency than the conventional deinking method. In was also found that the increase of pulp consistency can decrease the ozone treatment time which can meet the deinking quality. WRV of ozone deinked pulp obtained at 10% and 30% of pulp consistencies was lower than those of the conventional deinking method. However, the higher pulp consistency during ozone treatment improved WRV. Highest brightness was obtained at the ozone treatment condition of 30% pulp consistency and 10 minutes. The lower brightness at the other ozone treatment condition should be originated from the excessive decrease of ink particle size and then decrease of true ink removal efficiency. Scott bond was increased with the increase of pulp consistency and treatment time. However, the improvement of breaking length with ozone treatment was no significant.

  • PDF

Analysis of sewage treatment process for the improvement of T-N removal process (T-N 제거공정 개선을 위한 하수처리장 공정 분석)

  • Shin, Choon Hwan
    • Journal of Environmental Science International
    • /
    • v.27 no.2
    • /
    • pp.99-107
    • /
    • 2018
  • In order to design the improvement process for T-N removal, the treatment process of Suyoung, Gangbyeon, and Noxan sewage treatment plants (STP) in Busan was anlayzed. Suyoung STP shows a T-N removal efficiency of about 69.8% with MLE(Modified Ludzack ettinger) and A2O+MBR. However, it is necessary to improve the process to maintain over DO of 1 mg/L and is required to install a flow control tank to minimize the rainfall effect. Gangbyun STP shows a about 70.2% T-N removal efficiency with A2O+GFF(gravity fiber filtration). However, in order to improve T-N removal efficiency, it is needed to install MLE process to treat recycle water. Noksan STP shows a T-N removal efficiency of about 71.0% with MLE+Chemical treatment and shows stable T-N concentration in effluent. However, it is required a toxic chemical management process because bad wastewater flows into the STP, also is necessary a process improvement in order to increase internal recycling ratio. Especially, it is required a process improvement to increase HRT of nitrification tank because Suyoung and Gangbyeon STPs shows low nitrification efficiency during winter season.

Do customized orthodontic appliances and vibration devices provide more efficient treatment than conventional methods?

  • Aldrees, Abdullah M.
    • The korean journal of orthodontics
    • /
    • v.46 no.3
    • /
    • pp.180-185
    • /
    • 2016
  • The incorporation of technological advances in the field of clinical orthodontics to increase treatment efficiency has led to the development of customized appliances (Insignia$^{(R)}$), archwires (Suresmile$^{(R)}$), and the production of devices to enhance tooth movement (Acceledent$^{(R)}$). This review presents a comprehensive study of the literature concerning these products, and analyzes the available evidence of their efficiency. To date, one pilot study has evaluated the efficiency of the Insignia$^{(R)}$ system, three retrospective studies have assessed the efficiency of the Suresmile$^{(R)}$ system, and a few Acceledent$^{(R)}$ reports have described its effect on treatment time. Critical appraisal of the reviewed papers revealed that the efficiency of the Insignia$^{(R)}$ system cannot be confirmed based on the available evidence, while the use of Suresmile$^{(R)}$ can reduce overall treatment time in simple cases. The acceleration of tooth movement by Acceledent$^{(R)}$ devices has not yet been confirmed.

Treatment Study of Textile Wastewater by Fenton's Oxidation (펜톤 산화반응에 의한 염색폐수처리 연구)

  • 박영규
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.20-25
    • /
    • 2000
  • The wastewater treatment for the purpose of water-recycling was performed using Fenton's & ozone's methods. These methods were used to increase the treatment efficiency of textile wastewater and to search for the optimal operating conditions. The optimal conditions by Fenton process were determined so that input amounts of $FeSO_4{\cdot}7H_2O$ and $H_2O_2$ were $7.2mM/{\;}{\ell}$ and $49.0m/{\;}{\ell}$ respectively, treatment by ozone process had 92% removal efficiency at ozone concentration of 9.73g/min and $130mM/{\;}{\ell}$ of $H_2O_2$.

  • PDF

Efficiency enhancement of the organic light-emitting diodes by oxygen plasma treatment of the ITO substrate

  • Hong, J.W.;Oh, D.H.;Kim, C.H.;Kim, G.Y.;Kim, T.W.
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc2
    • /
    • pp.193-197
    • /
    • 2012
  • Oxygen plasma has been treated on the surface of indium-tin-oxide (ITO) to improve the efficiency of the organic light-emitting diodes (OLEDs) device. The plasma treatment was expected to inject the holes effectively due to the control of an ITO work-function and the reduction of surface roughness. To optimize the treatment condition, a surface resistance and morphology of the ITO surface were investigated. The effect on the electrical properties of the OLEDs was evaluated as a function of oxygen plasma powers (0, 200, 250, 300, and 450 W). The electrical properties of the devices were measured in a device structure of ITO/TPD/Alq3/BCP/LiF/Al. It was found the plasma treatment of the ITO surface affects on the efficiency of the device. The efficiency of the device was optimized at the plasma power of 250 W and decreased at higher power than 250 W. The maximum values of luminance, luminous power efficiency, and external quantum efficiency of the plasma treated devices increase by 1.4 times, 1.4 times, and 1.2 times, respectively, compared to those of the non-treated ones.

Effect of Plant Coverage on the Treatment Efficiency of Nitrogen and Phosphorus in Vegetative Filter Strips (식생피도가 식생여과대의 질소 및 인 처리효율에 미치는 영향)

  • Lee, Byungsoo;Gil, Kyungik
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.499-503
    • /
    • 2008
  • In order to control the non-point source pollution, a vegetative filter strips (VFS) was set up and the site-monitoring was performed. The objective of this study is to investigate the influence of the plant coverage on treatment efficiency of total nitrogen (T-N) and total phosphorus (T-P) using vegetative filter strips. According to the results, it seemed that the treatment efficiencies of T-N and T-P were closely related with the plant coverage ratio. The results showed that treatment efficiency of T-P average 50% at higher than 50% of the plant coverage and 20~23% at lower than 50% of the plant coverage. Also, the treatment efficiency of T-N increased with the increase of the plant coverage ratio.