• Title/Summary/Keyword: incomplete combustion

Search Result 141, Processing Time 0.029 seconds

Evaluating GHG Emissions Reduced by Real-time Traffic Information in Gasoline Vehicle (실시간교통정보 이용에 따른 가솔린차량의 온실가스 저감효과 평가)

  • Kim, Jun-Hyung;Um, Jung-Sup
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.4
    • /
    • pp.443-453
    • /
    • 2011
  • Real-time Traffic Information Service could play a key role in reducing incomplete combustion time remarkably since it can provide traffic information in real-time basis. Emission characteristics of test engines were studied in terms of travel distance and speed. The present study focused on a north district in Daegu, 12 km. The driving for the emission test was done at 8AM, 3PM, 7PM which represents various traffic conditions. The reduced emissions of Greenhouse Gases (GHG) have been measured for a travel distance running at different loads (conventional shortest route and Real-time Traffic Information) and GHG ($CO_2$, $CH_4$, $N_2O$) are all inventoried and calculated in terms of existing emission factors. The emission of GHG has been shown to reduce linearly with travel distance: $CO_2$ (9.15%), $CH_4$ (18.43%), $N_2O$(18.62%).

A Study on the Safety Improvement of Carbon Black Manufacturing Process (카본블랙 제조공정의 안전성 향상에 관한 연구)

  • Joo, Jong-Yul;Jeong Phil-Hoon;Sung-Eun, Lee
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.153-161
    • /
    • 2023
  • Carbon black is a material in the form of fine black powder obtained by incomplete combustion or pyrolysis of hydrocarbons, and is composed of 90-99% carbon, and the rest is composed of hydrogen and oxygen. In the event of an emergency during the manufacture of carbon black, the generated tail gas should be safely discharged through an emergency line to prevent fire, explosion, and environmental pollution accidents caused by the tail gas. If the pressure continues to rise, the pressure control valve shall operate and the rupture plate shall be ruptured sequentially and the tail gas shall be discharged to the vent stack through the emergency line. As an emergency emission system, even if some untreated substances in the tail gas are released into the atmosphere, they are lighter than air, so it is safe to discharge them to a safe place through the Vent Stack. If the gas pressure is rising or worse, it is discharged from the Vent Stackine, and discharging fuel.

Investigation on Diesel Injection Characteristics of Natural Gas-Diesel Dual Fuel Engine for Stable Combustion and Efficiency Improvement Under 50% Load Condition (천연가스-디젤 혼소 엔진의 50% 부하 조건에서 제동효율 및 연소안정성 개선을 위한 디젤 분무 특성 평가)

  • Oh, Sechul;Oh, Junho;Jang, Hyungjun;Lee, Jeongwoo;Lee, Seokhwan;Lee, Sunyoup;Kim, Changgi
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.3
    • /
    • pp.45-53
    • /
    • 2022
  • In order to improve the emission of diesel engines, natural gas-diesel dual fuel combustion compression ignition engines are in the spotlight. In particular, a reactivity controlled compression ignition (RCCI) combustion strategy is investigated comprehensively due to its possibility to improve both efficiency and emissions. With advanced diesel direct injection timing earlier than TDC, it achieves spontaneous reaction with overall lean mixture from a homogeneous mixture in the entire cylinder area, reducing nitrogen oxides (NOx) and particulate matter (PM) and improving braking heat efficiency at the same time. However, there is a disadvantage in that the amount of incomplete combustion increases in a low load region with a relatively small amount of fuel-air. To solve this, sensitive control according to the diesel injection timing and fuel ratio is required. In this study, experiments were conducted to improve efficiency and exhaust emissions of the natural gas-diesel dual fuel engine at low load, and evaluate combustion stability according to the diesel injection timing at the operation point for power generation. A 6 L-class commercial diesel engine was used for the experiment which was conducted under a 50% load range (~50 kW) at 1,800 rpm. Two injectors with different spray patterns were applied to the experiment, and the fraction of natural gas and diesel injection timing were selected as main parameters. Based on the experimental results, it was confirmed that the brake thermal efficiency increased by up to 1.3%p in the modified injector with the narrow-angle injection added. In addition, the spray pattern of the modified injector was suitable for premixed combustion, increasing operable range in consideration of combustion instability, torque reduction, and emissions level under Tier-V level (0.4 g/kWh for NOx).

Thermal Characteristics of Living Leaves in Pinus Densiflora with Heat Flux (복사열 증가에 따른 소나무 생엽의 열적특성 분석)

  • Park, Young-Ju;Lee, Hae-Pyeong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.75-82
    • /
    • 2010
  • To study the combustion characteristics of forest fuel by fire intensity, the experiment of combustion characteristics on Pinus Densiflora living leaves, which is the weakest species to the forest fire, was delivered, using variables of heat flux(25 kW/$m^2$, 50 kW/$m^2$, 75 kW/$m^2$). With the equipment of Cone calorimeter, the characteristics of ignition, heat, smoke release, CO and $CO_2$ release, and mass loss were analyzed. Pinus Densiflora living leaves containing moisture of 60.66% were not ignited at the heat flux of variables 25 kW/$m^2$, 50 kW/$m^2$, 75 kW/$m^2$. In proportion to the heat flux value, heat release amount and heat release rate reached maximum value rapidly: higher variables came to the maximum by the half rapidity and the maximum value were twice higher than the former lower variables respectively. As for the smoke release, the less heat flux the variable had, the more smoke release it had, due to incomplete combustion. The release amount of CO and $CO_2$ had more maximum value as the heat flux increased and more radiant heat meaned more carbon oxide. When the forest fire breaks out, therefore, a great amount of CO and $CO_2$ will be released by Pinus Densiflora.

A Study on the Fire Prevention Activities and Suppression Measures of Utility-Pipe Conduit (지하공동구 화재예방활동 및 진압대책에 관한 연구)

  • Lee, Jung-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.63-68
    • /
    • 2010
  • Utility-Pipe Conduit is, Housing and city effectively accommodate what they absolutely need power, communications, gas, pipeline, water supply, drainage, energy facilities etc, according to expansion of urban infrastructure are derived, several ways to solve problems in, collection facilities in place are maintained and managed facility. If Utility-Pipe Conduit is damaged, as well as national security, because their impact on society as a whole, by introducing large vulnerability in the fire prevention activities and suppression measures and disaster for our situation by introducing measures, comprehensive analysis of the fire risk, it shall establish fire prevention activities and suppression through analysis of Utility-Pipe Conduit design, institutional issues, the problem of fire protection facilities, fire spread phenomenon etc. Because of Utility-Pipe Conduit is an enclosed place, so incomplete combustion due to lack of oxygen supply that there are problem such dark smoke, carbon monoxide etc, toxic combustion products and heat generation and visual impairment is an issue difficult to enter. As well as fire prevention activities, the fire In light of the particularity of the under ground than above ground fire, so this phenomenon is weak fire fighting that fire to become effective fire fighting tactics, basically it is necessary difficulty softening, non-burn softening and prevent combustion expansion of the cable is installed on the Utility-Pipe Conduit, having to considering the specificity of the response command system and relevant organizations to establish an on-site, Structural identification and other information gathering required to record of Response agencies, keep air conditioning system 24 hours and strengthening Virtual Total Training of Response agen

A Study on the Mechanical and Combustion Characteristics According to Fiber Reinforcements Weight Fraction of FRTP (섬유강화재 함유율에 따른 FRTP의 기계적 특성 및 연소특성에 관한 연구)

  • Kim, Kyoung-Jin;Eom, Sang-Yong;Kim, Ki-Hwan
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.21-28
    • /
    • 2019
  • To examine the mechanical and combustion characteristics of FRTP, either polycarbonate or nylon were used as a matrix, and either glass fiber or carbon fiber were used as the fiber reinforcement. The fiber reinforcement content was differentiated at 0~40 wt%. The tensile strength and heat distortion temperature increased with increasing reinforcement content. When the fiber reinforcement content was above 30 wt%, the flammability rating showed V-0. As the fiber reinforcement content increased from 0 to 40 wt%, the peak heat release rate of polycarbonate decreased by approximately 51% and that of nylon decreased by approximately 24%. The rate of CO generation decreased for a period of time, and then increased. This appears to have resulted from incomplete combustion. The rate of CO2 generation shows a similar tendency with the heat release rate. As fiber reinforcement content levels increased from 0 to 40 wt%, the CO2 peak rate of polycarbonate generation decreased by approximately 50% and that of nylon decreased by 28%.

Characteristics of Particle Number and Exhaust emission by Alteration of MTBE Contents in Gasoline (휘발유의 MTBE 함량 변화에 따른 입자개수 및 배출가스 특성)

  • Lim, Taeyoon;Song, Hoyoung;Park, Cheonkyu;Hwang, Inha;Ha, Jonghan;Na, Byungki
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.42-47
    • /
    • 2015
  • While the oxygen content of gasoline for automobiles in Korea is regulated to less than 2.3 weight %, European and World-Wide Fuel Charter (WWFC) regulate it to less than 2.7 weight %. The oxygen content of oxygen-containing materials increases the octane number of the fuel due to the secondary combustion in the internal combustion engine. It has been reported to be effective in reducing emissions, such as CO, HC, which is caused by incomplete combustion. Before 2000s in the United States and Europe, there has been many researches about vehicle application of the changes in oxygen content of gasoline. However, there are not many domestic researches which reflect the improvement of the fuel quality and automotive technology. In this study, fuels of three different oxygen contents were applied to GDI and MPI engines. As a result, the changes of fuel consumption and emission gas were very similar depends of the oxygen content changes. The PN in GDI engine was decreased as the oxygen content was increased.

A Study on the Efficiency Estimation of Halogen free Fire Resistance Cable (저독성 내화전선 케이블의 성능평가에 관한 연구)

  • 윤헌주;홍진웅;유동일;윤재선;곽동일
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.18-23
    • /
    • 2002
  • Efficiency estimation of toxicity free resistance cable experiments were conducts to understand toxicity free fire ersistance polyolefin insulation material and smoke density characteristic and combustion gas corrosion analysis. A main cause of fire-growth and generating toxic gas when it burns, should be dealt with great care in life safety design. Similar patterned fire incidents such as, Inchon Live-Hof Pub Restaurant as, Sea-land Children Resort have proven that serious loss of lives were caused by hazardous gas generated fire resistance cable materials. In this paper, Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of 2.5$\pm40.04〔w/$\textrm{cm}^2$〕for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. Also, the fire gases was occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC which has high content of carbon in chemical compound.

Study of the Density of Smoke and Harmful Gases of Adhesive Indirect Moxibustion (접착식 간접구의 연기 밀도 및 유해가스 발생 확인 연구)

  • Kim, Eun-Jung;Kim, Yu-Jong;Hwang, Ji-Hoo;Cho, Hyun-Seok;Kim, Kyung-Ho;Lee, Seung-Deok;Kim, Kap-Sung
    • The Journal of Korean Medicine
    • /
    • v.33 no.1
    • /
    • pp.42-51
    • /
    • 2012
  • Objectives: We measured the density of smoke and harmful gases emitted from burning adhesive indirect moxa. Through the test we aimed to find out if there was an excessive amount of smoke emitted and if it included harmful gases. Methods: 9 types of adhesive indirect moxa were chosen. The buffer layers which do not burn during treatment were removed and 10g of each moxa were made into powder and put into a holder. A smoke density chamber (Smoke Density Chamber FTT. U.K) and Fourier transform infrared spectroscopy (FT-IR I 4001. MIDAC U.S.A.) were used to measure the density of smoke and harmful gases emitted from burning moxa by ISO 5659-2 test. Results: The result of measuring maximum smoke density showed that the regular indirect adhesive moxa (A-F) emitted high density smoke of 172.1-291.4Ds. The smokeless moxas, Seoam moxas, emitted the least amount of 3.4-5.5Ds. Concentrations of 7 typical harmful gases (CO, HCl, HCN, HBr, HF, SO2, NOx) were measured and all of the moxas emitted CO due to incomplete combustion. 4 types of moxa emitted NOx and all smokless moxas emitted NOx. HBr, HCN, HCl, HF, SO2 were not found in any of the moxas. Conclusions: The amount of harmful gases emitted from burning moxa was much lower than short-term exposure standards of chemical and physical factors (Ministry of Labor 2010-44). Further experiments measuring gases from moxa combustion should be done in larger environments similar to normal medical clinics.

Determination of Correlation between Cetane Number, Derived Cetane Number and Cetane Index for Diesel Fuel (경유연료의 세탄가, 유도세탄가 및 세탄지수의 상관관계 분석)

  • Jeon, Hwayeon;Kim, Ji Yeon;Kim, Shin;Yim, Eui Soon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1134-1144
    • /
    • 2018
  • Cetane Number is one of the quality standard for diesel, which assesses the compatibility of ignition quality of diesel compression in diesel engines. Cetane number must be upper 52 to keep the recent diesel quality standards. It is known that if cetane number is high, there will be shorter ignition delay periods than being lower. On the other hands, if cetane number is too high that exceeds the quality standard, there will increase the air pollution and decrease of the fuel efficiency because incomplete combustion. In South Korea, various methods are being used to measure the cetane number such as cetane number that used CFR engine, cetane index from calculate density and distillation temperature and derived cetane number to make up for CFR engine that ignition delay in high temperature is implemented. In this study will be conducted by collecting the diesel from the major oil companies, and try to analyze the correlation between the different methods of cetane number with various factors. At the results of this study, it was shown that the cetane index is high then cetane engine and derived cetane number. therefore it will be necessary to additional research for out of cetane number quality standards.