• Title/Summary/Keyword: incineration system

Search Result 144, Processing Time 0.026 seconds

Prediction of greenhouse gas emission from municipal solid waste for South Korea

  • Popli, Kanchan;Lim, Jeejae;Kim, Hyeon Kyeong;Kim, Young Min;Tuu, Nguyen Thanh;Kim, Seungdo
    • Environmental Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.462-469
    • /
    • 2020
  • This study is proposing a System Dynamics Model for estimating Greenhouse Gas (GHG) emission from treating Municipal Solid Waste (MSW) in South Korea for years 2000 to 2030. The government of country decided to decrease the total GHG emission from waste sector in 2030 as per Business-as-usual level. In context, four scenarios are generated to predict GHG emission from treating the MSW with three processes i.e., landfill, incineration and recycling. For prior step, MSW generation rate is projected for present and future case using population and waste generation per capita data. It is found that population and total MSW are directly correlated. The total population will increase to 56.27 million and total MSW will be 21.59 million tons in 2030. The methods for estimating GHG emission from landfill, incineration and recycling are adopted from IPCC, 2006 guidelines. The study indicates that Scenario 2 is best to adopt for decreasing the total GHG emission in future where recycling waste is increased to 75% and landfill waste is decreased to 7.6%. Lastly, it is concluded that choosing proper method for treating the MSW in country can result into savings of GHG emission.

Estimation of polycyclic aromatic hydrocarbons emission from sewage sludge of sewerage treatment plants in Korea

  • Kim, Dong-Hwan;Hwang, Jong-Seob;Lee, Min-Hee;Ok, Gon
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.85-88
    • /
    • 2003
  • Polycyclic aromatic hydrocarbons (PARs) are an important group of organic contaminants present in sewage sludge, due to their persistence, toxic, bioaccumulative and long range transfer. These characters make themselves as Persistent Organic Pollutants(POPs) in Long Range Transboundary Air Pollutions convention(LRT AP) of Europe. A method of the gas chromatographic-mass spectrometric (GC-MS) determination of PARs present in sewage sludge was developed and applied to analyzed samples from five sewerage treatment plants (SWTPs), having different treatment types. PARs were extracted from freeze-dried samples by toluene 16 hours in a soxhlet extraction system. The sludge extracts were cleaned-up by an activated silica gel column chromatography. The sum of the 16 US Environmental Protection Agency PARs sewage sludge samples varied from 2.44 to 4.82 ${\mu}g$/g. Concentration of emission carcinogen PARs(PARcarc), such as Benzo(a)anthracene, Benzo(b)fluoranthene, Benzo(k)fluoranthene, Benzo(a)pyrene, Dibenzo(a, h)anthracene and Indeno(1, 2, 3-cd)pyrene ranged from 0.62 to 1.03 ${\mu}g$/g. The total amount of PAHs emission from sewage sludge in Korea was calculated as a top-down approach. PARs and $\sum$PAHcarc from sewage treatment plants had several pathway each by-products. In the ocean dumping, PAHs and $\sum$PAHcarc emissions were 1155.95 kg/year and 5040.32 kg/year. In recycle, PAHs and $\sum$PAHcarc emissions were 98.36 kg/year and 428.87 kg/year. In the landfill, PAHs and $\sum$PAHcarc emissions were 190.40 kg/year and 830.21 kg/year. In the incineration, PAHs and $\sum$PAHcarc emission were 33.10 kg/year and 830.21 kg/year. (In case of incineration, the whole provisions of PARs and $\sum$PAHcarc contained to flowed in sludge was supposed to be exhausted to environment through exhaust after incineration.)

  • PDF

A Study on the Chlorobenzene and Chlorophenol Behavior in Plasma Type Pyrolysis/Gasfication/Melting Process (플라즈마 방식 열분해 가스화용융시설의 공정별 클로로벤젠 및 클로로페놀 배출거동에 관한 연구)

  • Shin, Chan-Ki;Shin, Dae-Yun;Kim, Ki-Heon;Son, Ji-Whan
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.2
    • /
    • pp.9-20
    • /
    • 2007
  • The incineration process has commonly used for wastes amount reduction and thermal treatments of pollutants as the technologies accumulated. However, the process is getting negative public images owing to matter of hazardous pollutants emission. Specially dioxins became a main issue and were mostly emitted from municipal solid wastes incineration. In this reason, pyrolysis/gasification/melting process is presented as an alternative of incineration process. The pyrolysis/gasification/melting process, a novel technology, is middle of verification of commercial plant and development of technologies in Korea. But the survey about the pollutant emission from the process, and background data in these facilities is necessary. So in this survey, t is investigated that the behavior of chlorobenzenes and chlorophenols in plasma type pyrolysis/gasification/melting plant of pilot scale. We investigated discharging behavior of each phase of chlorobenzene through each process in the plsasma type pyrolysis/gasification/melting process. From this result, it was found that about 99 percent of particle-phase chlorobenzene was removed, but on the other hand gas-phase chlorobenzene was increased by about 600 percent through heat exchanger, flue gas cooling, system and semi dry absorption bag filter(SDA/BF). Also, this investigation presented that di-chlorobenzene(DCB) tri-chlorobenzene(TCB), tetra-chlorobenzene(TeCB), penta-chlorobenzene (PCB), except mono-chlorobenzene(MCB) and hexa-chlorobenzene(HCB) were increased through the flue gas cooling system and the semi dry absorption bag filter(SDA/BF). It was investigated that concentration of particle-phase chlorophenol was decreased by about 66 percent, but on the other hand, concentration of gas-phase chlorophenol was increased by about 170 percent through heat exchanger, flue gas cooling system, and semi dry absorption bag filter(SDA/BF). Also, it was found that di-chlorophenol(DCP), tri-chlorophenol(TCP), and penta-chlorophenol(PCP) were increased through the flue gas cooling system, and the semi dry absorption bag filter(SDA/BF). It can be considered that small-scale pilot facility and short investigation period might cause the concentration increase through the flue gas cooling system and the semi dry absorption bag filter(SDA/BF). A further study on real-scale pilot facility and accurate investigation may be required.

Radiological Safety Assessment for KAERI Incineration Plant on the Basis of Trial Burn Results (시험소각결과에 기준한 한국원자력연구소 소각시설의 방사학적 안전성 평가)

  • Yang, Hee-Chul;Kim, Bong-Hwan;Kim, Chang-Hee;Park, Won-Man;Jeong, Myung-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.2
    • /
    • pp.109-114
    • /
    • 1998
  • Radiological safety for the conventional operation of Demonstration-Scale Incineration Plant (DSIP) was assessed on the basis of the results of trial burns using the simulated and real radioactive wastes. Radiation dose assessments for routine releases on an annual basis as well a several severe accidental releases on a short-term basis (2h) revealed that there would be no significant environmental impact when low-level waste Is incinerated in DSIP. For semivolatile radioactive cesium species, expected emission concentrations slightly exceeded 10% of maximum permissible concentration. Removal characteristics of the bag filter for condensed-phase cesium species was investigated by the trial burns of simulated waste with inactive cesium tracer. In the off-gas before passing through bag filter, distributions of condensed cesium species in the transition size ranging between the diffusional and inertial region are less than 5%. The overall collection efficiency of the bag filter for cesium species was higher than 99.9%, showing enough decontamination capability as a primary filter for the low-temperature dry off-gas system in radwaste incineration plant.

  • PDF

Thermal Hydraulic Power Analysis of the HYPER Target Beam Window (미임계로 표적빔창의 열수력 해석)

  • Song Min-Geun;Ju Eun-Sun;Choi Jin-Ho;Song Tae-Young;Tak Nam-Il;Park Won-Sok
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.39-42
    • /
    • 2002
  • The nuclear transmutation technology to Incinerate the long lived radioactive nuclides and produce energy during the incineration process is believed to be one or the best solutions. HYPER(${\underline{HY}}brid {\underline{P}}ower {\underline{E}}xtraction {\underline{R}}$eactor)is the accelerator driven transmutation system which is being developed by KAERI(Korea Atomic Energy Research Institute). Lead-bismuth(Pb-Bi) is adopted as a coolant and spallation target material. In this paper, we performed the thermal-hydraulic analysis of HYPER target using the commercial code FLUENT, and also calculated thermal and mechanical stress of the beam window using the commercial code ANSYS. It is found that there is an optimum value for the window diameter and the maximum allowable beam current can be increased to 17.3 mA for the inner diameter of windows, 40 cm. Finally, the other shapes such as uniform or scanned beam were considered. The results of FLUENT calculations show that the uniform type is preferable to the other shapes of the beam in terms of the window and target cooling and the maximum window temperature is lower than that of the parabolic beam by $58 ^{\circ}C$ for the beam current, 13 mA.

  • PDF

BAT-AEL Calculation in Waste Incineration Facility (폐기물 소각시설 최적가용기법 연계배출수준 (BAT-AEL) 설정)

  • Shin, Sujeong;Park, Jae-Hong;Lee, DaeGyun;Kim, Dai-Gon;Bae, YeonJoung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.144-155
    • /
    • 2018
  • As the public interest in environmental issues increased, the "Act On The Integrated Control Of Pollutant-Discharging Facility" was enacted. Through the integrated environmental pollution prevention act in which 19 industries with large environmental impacts are sequentially applied, pollutants can be managed in a medium-integrated manner and integrated permission of the business unit is possible and BAT can be applied to enable a scientific and proactive environmental management system. In addition, if the facility with BAT works normally, the pollutant emission is offered with the range of lower limit to upper limit. This study analyzed the overview of Best Available Techniques-Associated Emission Levels (BAT-AEL), and its setting procedure and method, and then suggested the BAT-AEL of a waste incineration facility. In comparative analysis on Emission Limit Values (ELVs) of EU, this study tries to propose improvement matters and development directions if the relevant standard is revised.

Hepatotoxicity Assessment of Derived Product from Pyrolysis System for Waste Plastic Recycling (폐플라스틱 재활용을 위한 열분해공정 파생물질의 간독성 평가)

  • Shin Hea Soon
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.2
    • /
    • pp.201-206
    • /
    • 2004
  • Recently, waste plastic recycling technology is transforming from Incineration system to pyrolysis gasification system which can derive the resources from environmental waste and charge no more environmental burden to nature. The present study was carried out to investigate the potential acute toxicity of derived product of pyrolysis gasifications system for recycling of waste plastic by a single oral dose in Sprague-Dawley Rats. In order to evaluate the hepatotoxic effects of derived product of pyrolysis gasification system, activities of serum transaminase were measured in rats. No related changes in survivals, clinical signs and the ratio of the liver to body weights of rats were monitored. The results showed that the single oral administration of material of pyrolysis system for recycling of waste plastic did not induce any toxic effect at orally single dose level of 0 and 100, 200, 400, 800mg/kg body weight in rats. We could not find out any significant tocxicity induced by single oral administrate of material of pyrolysis system for recycling of waste plastic.

A Study on the Optimal Design of Urban Utility Systems (부하에 따른 도시기반 공급.처리시스템의 최적설계에 관한 연구)

  • Lee, Tae-Won;Kim, Yong-Ki
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.732-737
    • /
    • 2001
  • The mathematical method was developed and numerical analyses were carried out with various parameters to provide substantial data for optimal design and operation of urban utility systems. The composition of systems and their specifications, such as co-generation system, heat pump system, incineration system and other heating and cooling system could be obtained through these analyses for various resource and energy requirements in urban area. As results the system constituents and operating characteristics, and their economic performances such as the value of objective function, initial and an operating costs were discussed for various load patterns. The effective system design method and the excepted effects of the several unused energy recovery systems were also briefly discussed with the variation of the buildings and facilities species and their capacities.

  • PDF

A Study on the Design Method and the Effect Analysis for the Introduction of the Integrated System Model of Individual Urban Utility Plants (에너지공급시설 및 환경기초시설의 복합화 방안 및 적용효과 분석)

  • Lee, Tae-Won;Kim, Yong-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.235-240
    • /
    • 2005
  • Recently urban utility plants in urban areas of Korea, such as energy supply systems, municipal waste incineration systems, sewage treatment systems and so on, have caused some critical troubles, for instance the insensitive response to the seasonal or daily variation of loads, the low system efficiency and inefficient use of energy because of the large-scale system located a great distance. Therefor the design method of optimal integrated system model of various urban utility plants proposed in this study suitably to the present situation of Korea. Also, the effect analysis for the introduction of compound utility plants was studied for a new town model on a 60,000 persons scale. As the results we found that the complex plant was superior to individual urban utility plant in side of the initial investment expenses, the operating cost and other reasons.

  • PDF

Determination of Residual Pesticides in Recycle Product of Waste Plastic Pyrolysis (폐비닐 열분해 재활용품 중의 잔류농약 분석)

  • Shin Hea Soon;Shim Sung Hoon
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.3
    • /
    • pp.315-320
    • /
    • 2004
  • Environmental waste treatment technology is transforming from incineration system to pyrolysis gasification system. And there it is necessary for our country to adapt gasification system urgently to prevent the land pollution and lack of landfill area. The objective of this study was to determine the pesticides residues of derived product of pyrolysis gasification system for recycling of waste plastic by gas chromatograph-mass selective detector and nitrogen phosphorus detector. The residual pesticides were not detected in derived product of waste recyling. But some pesticide was detected on raw level (0.02 ~ 0.05 ppm) in waste plastic sample.