• Title/Summary/Keyword: incandescent lamp

Search Result 105, Processing Time 0.025 seconds

Electromagnetic Properties of Ring -Shaped Electrodeless Fluorescent Lamps for Ferrite Core (페라이트를 이용한 환형 무전극 램프의 전자계 특성)

  • Jo, Ju-Ung;Lee, Seong-Jin;Choi, Yong-Sung;Kim, Yong-Kab;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.249-251
    • /
    • 2003
  • The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. Therefore, the line time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250[kHz] and some specific conditions.

  • PDF

Electromagnetic Field Analyses of Electrodeless Fluorescent Lamp (무전극 전구형 형광램프의 전자계 해석)

  • Kim, Kwang-Soo;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dea-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.67-70
    • /
    • 2002
  • The electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. but Increasing awareness of electromagnetic compatibility(EMC) issues in lighting application, the problems of interference generation by electrodeless fluorescent lighting system have been highlighted. In this paper, Maxwell 2D finite element analysis program(ansoft) is used to obtain electromagnetic properties associated with the coil and nearby structures. and also evaluated Flux, B, H, by changing the input current.

  • PDF

A Study on Emission Characteristics of Ne Gas Using a Single Langmuir Probe Method in Radio-Frequency Inductively Coupled Plasma (13.56MHz ICP에서 단일 탐침법에 의한 Ne 가스의 발광특성 연구)

  • Jo, Ju-Ung;Choi, Yong-Sung;Kim, Yong-Kab;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.150-152
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. The electrodeless fluorescent lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, electron temperature and electron density were measured in a radio-frequency inductively coupled plasma using a Langmuir probe method for emission characteristics. Measurement was conducted in an Ne discharge for pressure from 10 [mTorr] and input RF power 100 [W] to 150 [W]. As for the electron density, a electron temperature was more distinguished for a emission characteristic. The results of ideal may contribute to systematic understanding of a electrodeless fluorescent lamps of emission characteristics.

  • PDF

A Study on Emission Characteristics of Ar, Ne Gas Using a Single Langmuir Probe Method in Radio-Frequency Inductively Coupled Plasma (13.56MHz ICP에서 단일 탐침법에 의한 Ar, Ne 가스의 발광특성 연구)

  • Jo, Ju-Ung;Choi, Yong-Sung;Kim, Yong-Kab;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.167-170
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. The electrodeless fluorescent lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, electron temperature and electron density were measured in a radio-frequency inductively coupled plasma using a Langmuir probe method for emission characteristics. Measurement was conducted in an Argon, Ne discharge for pressure from 1 [mTorr] and input RF power 10 [W] to 150 [W]. As for the electron density, a electron temperature was more distinguished for a emission characteristic. The results of ideal may contribute to systematic understanding of a electrodeless fluorescent lamps of emission characteristics.

  • PDF

Optical and Electromagnetic Distribution of Ring-shaped Electrodeless Fluorescent Lamps (환형 무전극 램프의 광학적, 전자계적 특성)

  • 조주웅;이성진;최용성;김용갑;박대희
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.161-163
    • /
    • 2003
  • Ring-shaped electrodeless fluorescent lamp is removed the internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250[㎑]and some specific conditions. The optical measurement measured luminance and a temperature and an optical spectrum distribution for 10 minutes in a one minute interval at the same time.

  • PDF

Study on the Gathering Effects of Anchovy Scoop Net in the neighboring waters of the Cheju Island (제주도 근해 멸치 분기초망의 집어효과에 관한 연구)

  • SOHN Tae-Jun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.21 no.3
    • /
    • pp.184-192
    • /
    • 1988
  • Anchovy, Engraulis Japonica were caught by scoop net with fishing lamp in the surrounding water of Cheju and Seogwipo, and their gathering depth, gathering effects, change of catch by the age of the moon and submarine illumination were investigated from May to August 1985. Fish finder (SR-385) and fishing lamp (1 Kw incandescent) were set up at one meter of starboard of scoop net and one meter ahead of the prow together with two meters above the water surface respectively. The submarine illumunation was measured at 2m interval to both vertical direction of 0~18m and horizontal direction of 0~12m form the standard point which is to be 0.1m depth right under the fishing lamp. The catch of anchovy by scoop net was almost $90\%$ of total amount during the early period and the late period in moon age while as low as $10\%$ only was cought during the middle period. The catching depth of anchovy shoals by scoop net with fishing lamp was approximately 2~5m and submarine illuminations were 20~42 Lux, 24~48 Lux in Cheju and Seogwipo respec lively. Submarine illumination which could be cought by scoop net with fishing lamp should be 7~12 times lighter than before gathering since the shoals swiming at 10~15m depth which is 1.7~7 Lux illumination made by 1 Kw. AC 100V incandescent lamp, a surface gathering lamp of 2m high above anchovy scoop net came up to 2~5m depth which is 20~42 Lux illumination. The catching depth of anchovy by scoop net was 2~3m and this could be increased to 4m even though the AC voltage was decreased from 100V to 80V at final fishing stage.

  • PDF

Design and Fabrication of a LED Floodlight for Naval Vessels (함정용 LED 투광등 설계 및 제작)

  • Kim, Se-Jin;Kil, Gyung-Suk;Kim, Dong-Geon;Kim, Il-Kwon;Song, Dong-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.10
    • /
    • pp.771-777
    • /
    • 2013
  • This paper dealt with the development of a LED floodlight for naval vessels to replace the conventional floodlight using an incandescent and a halogen lamp. We found a technical solution for current problems of conventional lights and also improved optical characteristics by developing a LED floodlight which has a typical long-lived light source with high efficiency. To satisfy the requirements specified in Korea Standard Vessels (KS V), the optical structure was designed with selected LED package and lens. A LED module was composed of 10 LEDs in series for stable luminous output, and an aluminium heat sink was adopted for effective heat-radiation design. The LED floodlight was fabricated as a module type so that it can easily replace the conventional light source. The power consumption of the prototype floodlight was only a tenth of a conventional one with the same optical performance. Also, a test showed the floodlight satisfied the electrical, optical and environmental requirements of the standards.

Color Temperature Measurement and Classification of Ambient Light Sources Using two Color Sensors, Yellow and Cyan (옐로우와 사이안 두 광센서를 사용한 주위 조명광의 색온도 측정 및 분류)

  • Choi, Duk-Kyu;Kwon, Yong-Dae;Kwon, Ki-Ryong;Sohng, Kyu-Ik
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.6
    • /
    • pp.409-417
    • /
    • 1998
  • Originally, the reference white of the NTSC system used to be CIE illuminant C of 6774K. However, that of color television receiver has been adjusted to 9300K as a result of consumer preference for a very bluish white for monochrome television. Recent studies have revealed that the preferred color temperature of display white should be 3000K or 4000K higher than that of surround illuminant. Therefore it is required to classify ambient lighting source. In this paper, a efficient method that can distinguish the ambient incandescent lamp from fluorescent lamp under television viewing condition is developed using only two color sensors, yellow and cyan. Experimental results show that the proposed method is very useful for the discrimination of ambient lighting source, fluorescent of 6000K and incandescent lamp of 3000K. The system was also tested for mixture of these light sources.

  • PDF

Electromagnetic distribution looped Electrodeless Fluorescent Lamps (환형 무전극 램프의 전자계 분포특성)

  • Jo, Ju-Ung;Lee, Seong-Jin;Choi, Yong-Sung;Kim, Yong-Kab;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.312-315
    • /
    • 2003
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250[kHz] and some specific conditions.

  • PDF

A study on Electromagnetic Propertie of the Ring-shaped electrodeless fluorescent lamp (동근형 무전극 형광램프의 전자계 특성)

  • Lee, Seong-Jin;Kim, Nam-Kun;Park, No-Jun;Lee, Jong-Chan;Jung, Young-II;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.220-221
    • /
    • 2006
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved Quality of the lighting space. Above all, the advantages of ring-shaped electrodeless fluorescent lamp are the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps last up to 60,000 hours, There are intended as a highly efficient replacement for the incandescent reflector lamp in many applications. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250 kHz and some specific conditions. In addition, the optical characteristics of ring-shaped electrodeless fluorescent lamp were measured including light flux, efficiency and color temperature for each case.

  • PDF