• Title/Summary/Keyword: in-position

Search Result 26,493, Processing Time 0.047 seconds

The Knee Joint Position Sense in Healthy Women (정상 성인 여성의 무릎관절 위치감각)

  • Yang, Kyung-Hye;Lee, Hyun-Ok
    • PNF and Movement
    • /
    • v.8 no.1
    • /
    • pp.31-39
    • /
    • 2010
  • Purpose : The purpose of this study is to ascertain whether age, body mass index(BMI) and exercise frequency(EF) are correlated with knee joint position sense in healthy women. Methods : Healthy women of 150 who participated in this study were tested knee joint position sense; each reposition error was analyzed according to the age, BMI and EF. Reposition error was measured with a Myrin goniometer. Results : The age groups, BMI groups and EF groups demonstrated significant differences of the knee joint position sense. The older the healthy women are, the higher BMI is, and the lower EF is, the more decreased knee joint position sense has become. Conclusion : The older the women are, the higher BMI is, and the lower EF is, the more decreased the knee joint position sense in healthy women is. Therefore it needs to be considered to require management of obesity and regular exercise for prevention of knee injuries due to decreased joint position sense.

  • PDF

Computation of Sun Position for the Sun Tracking Control System of Solar Concentrator (집광식 태양열 집열기의 태양추적장치를 위한 태양위치계산)

  • Park, Y.C.;Kang, Y.H.
    • Solar Energy
    • /
    • v.18 no.4
    • /
    • pp.87-94
    • /
    • 1998
  • This work presents a method to compute the sun position(azimuth and elevation), sunrise and sunset times. Accurate computation of sun position is very important to the precise tracking of the sun for the solar concentrator, which enables the maximum collection of solar energy. Methods to compute the sun position are available in the literature already. However most of them do not have accuracy verification, thus makes hard in selecting the most accurate sun position computation method. We first select the most accurate sun position computation method among the methods presented in the literature by comparing the computed sun position with Korean Almanac of Korea Astronomy Observatory. Then a procedure to compute the sunrise and sunset times is presented. Computed sun position shows $0.02^{\circ},\;0.6^{\circ}$ and one minute differences in azimuth, elevation and sunrise/sunset times respectively compared with Korean Almanac.

  • PDF

Study of Patient's Position to Reduce Late Complications in High Dose Rate Intracavitary Radiation of the Uterine Cervix Cancer (자궁경부암의 고선량율 강내 방사선치료 시 부작용을 줄이기 위한 적정 치료 자세의 연구)

  • Yun, Hyong-Geun;Shin, Kyo-Chul
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.477-483
    • /
    • 1998
  • Purpose : Radiation proctitis and radiation cystitis are frequent and problematic late complications in patients treated with radiation for the uterine cervix cancer. Authors tried to find out the better patient's position in high dose rate intracavitary radiation to reduce the radiation dose of bladder and rectum. Materials and Methods : In 13 patients, Foley Catheters were inserted to patient's bladder and rectum and were ballooned with radioopaque dye. After insertion of a tandem and two ovoids, semi-orthogonal anteroposterior and lateral films were taken in both lithotomy and supine position. The rectal point and bladder point were defined according to the criteria recommended in the ICRU Report 38 with modification. Using these films, all patients' bladder and rectal dose were calculated in both positions (the radiation dose of A point was set to 400 cGy). And also, the distance of bladder and rectum from uterine cervical os was calculated in both positions. Results : The average radiation dose of rectum was 240.7 cGy in lithotomy position and 278.3 cGy in supine position, and the average radiation dose of bladder was 303.5 cGy in lithotomy position and 255.8 cGy in supine position. After the paired t-test, the radiation dose of rectum in lithotomy position was marginally significantly lower than that in supine position, while the radiation dose of bladder in lithotomy position was significantly higher than that in supine position. On the other hand, the average distance between rectum and cervical os was 35.2 mm in lithotomy position and 32.3 mm in supine position. and the average distance between bladder and cervical os was 30.4 mm in lithotomy position and 34.0 mm in supine position. After the paired t-test. the distance between rectum and cervical os in lithotomy position was significantly longer than that in supine position, while the distance between bladder and cervical os in lithotomy position was significantly shorter than that in supine position. Conclusion : The radiation dose of bladder can be reduced in supine position and the radiation dose of rectum can be reduced in lithotomy position, so we can choose appropriate position in each patient.

  • PDF

The Effects of Qigong Position on Heart Rate Variability (심박변이도에 기공(氣功) 자세(姿勢)가 미치는 영향)

  • Jung, Dae-Sun;Park, Ji-Ha;Park, Soo-Jin;Han, Chang-Hyun;Lee, Sang-Nam
    • Korean Journal of Oriental Medicine
    • /
    • v.17 no.2
    • /
    • pp.85-100
    • /
    • 2011
  • Objectives : This study aimed to investigate the effect of four common types of Qigong position (standing, sitting, supine, and horse-riding position) on the autonomic nervous system. Method : Thirty healthy subjects participated in this study once a week for four weeks. Heart Rate Variability (HRV) was measured three times (before, during, and after the position) while the subject maintained one of four positions for ten minutes. Result : There were significant changes HRV in the standing position. In the sitting position, both the sympathetic and parasympathetic nerves were activated. On the other hand, in the spine position, heart rate (HR) was decreased. Activation of sympathetic and parasympathetic nerves was also observed in this position. Significant increases of indices related to awakening and concentration were observed accompanied by increase of HR and a sympathetic nerve was activated in the riding-horse position. Conclusions : In the present study, it was shown that each Qigong position caused various and significant changes in autonomic nervous system. It would be expected that these results can be applied to choose appropriate Qigong position according to objective of Qigong therapy although it is remained to further evaluate the effects of long-term maintenance of Qigong positions and repeated Qigong training.

Identification of English Labial Consonants by Korean EFL Learners (한국 EFL 학생들의 영어 순자음 인지)

  • Cho, Mi-Hui
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.12
    • /
    • pp.186-191
    • /
    • 2006
  • The perception of English labial consonants was investigated via experiment where 40 Korean EFL learners identified nonwords with the target labial consonants [p, b, f, v] in 4 different prosodic locations: initial onset position, intervocalic position before stress, intervocalic position after stress, and final coda position. The overall result showed that the proportion of perception accuracy of the target consonants was rather low, amounting to only 55%. There was also a positional effect since the accuracy rates for perceiving the four target consonants differed by position. Specifically, the average accuracy rate of the target consonant identification was higher in intervocalic position before stress (70%) and initial onset position (67%) than in intervocalic position after stress (45%) and final coda position (36%). Further, the accuracy rate for [f] is was high in all prosodic locations except intervocalic position after stress. The perception patterns were accounted for by the markedness and perceptual factors in conjunction with stress location.

  • PDF

The Effect of Pelvic Inclination on Voice Production in sitting (앉은 자세에서 골반 경사도가 음성에 미치는 영향)

  • Choe, Jeong Hui
    • The Journal of the Convergence on Culture Technology
    • /
    • v.1 no.2
    • /
    • pp.91-95
    • /
    • 2015
  • The purpose of this study was to evaluate the difference voice production, according to the pelvic inclination while in the sitting position. Measure the sound produced(pitch) in three positions with the Praat program. position: anterior tilt position, posterior tilt position, neutral position(seat surface tilted 15 degrees). We found that the mean values of pitch were statistically significant different according to three types of sitting positions (p<0.05). The following result was observed: anterior tilt position > posterior tilt position > neutral position. There was significant difference in the neutral position. This finding suggests that the seat surface inclinations have an effect on speech production. Especially, neutral position may be an effective posture that may help increases the speech production.

On-line Compensation Method for Magnetic Position Sensor using Recursive Least Square Method (재귀형 최소 자승법을 이용한 자기 위치 센서의 실시간 보상 방법)

  • Kim, Ji-Won;Moon, Seok-Hwan;Lee, Ji-Young;Chang, Jung-Hwan;Kim, Jang-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2246-2253
    • /
    • 2011
  • This paper presents the error correction method of magnetic position sensor using recursive least square method (RLSM) with forgetting factor. Magnetic position sensor is proposed for linear position detection of the linear motor which has tooth shape stator, consists of permanent magnet, iron core and linear hall sensor, and generates sine and cosine waveforms according to the movement of the mover of the linear motor. From the output of magnetic position sensor, the position of the linear motor can be detected using arc-tan function. But the variation of the air gap between magnetic position sensor and the stator and the error in manufacturing process can cause the variation in offset, phase and amplitude of the generated waveforms when the linear motor moves. These variations in sine and cosine waveforms are changed according to the current linear motor position, and it is very difficult to compensate the errors using constant value. In this paper, the generated sine and cosine waveforms from the magnetic position sensor are compensated on-line using the RLSM with forgetting factor. And the speed observer is introduced to reduce the effect of uncompensated harmonic component. The approaches are verified by some simulations and experiments.

Difference of Muscle Activity by Pelvic Tilt in Side-Lying Hip Abduction

  • Kim, Hae-Joong;Lee, Han-Suk;Jung, Hyung-Gook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.3
    • /
    • pp.59-66
    • /
    • 2017
  • PURPOSE: This study was to evaluate the muscle activity of gluteus medius, tensor fascia latae, and quadratus lumborum during side-lying abduction exercise in various pelvic tilting positions. METHODS: We measured the activity of three muscles in three pelvic tilt positions for 17 normal subjects with performing the side-lying hip abduction. Three pelvic tilt positions were posterior tilt, neutral tilt and anterior tilt. We used the mean value after participants performed the hip abduction three times each position. RESULTS: The activity of gluteus medius within three pelvic positions showed the highest activity in pelvic posterior tilt position and the lowest in pelvic neutral tilt position (p = .04). The activity of tensor fascia latae showed the lowest in pelvic posterior tilt position and the highest in pelvic posterior tilt position (p = .00). The activity of quadratus lumborum revealed the lowest activity in pelvic neutral tilt position and the highest in pelvic anterior tilt position (p = .00). The activity of selective gluteus medius activation according to pelvic displacement showed the highest activity in pelvic neutral tilt position and lowest in pelvic anterior tilt position (p = .00). CONCLUSION: Hip abduction with Pelvic posterior tilt position may be effective in increasing gluteus medius and may be effective in strengthening exercise program for the gluteus medius. In addition, Hip abduction with pelvic neutral position may have an effect on the selective gluteus medius, which is considered to be effective in the exercise program for muscle reeducation training of the gluteus medius.

Analysis and Suggestions of the Librarians Public Servants in USA, UK and Korea (영미 및 한국의 사서직제 분석과 시사점)

  • Yoon Hee-Yoon
    • Journal of Korean Library and Information Science Society
    • /
    • v.36 no.2
    • /
    • pp.121-140
    • /
    • 2005
  • The purpose of this paper is to analyze the public servant and librarian position in USA, UK, and Korea and to give suggestions to improve the position classification of librarianship in Korea. Professional librarian positions in USA and UK are very useful to understand the excellency of position classification system. On the other hand, librarian positions in Korea is useful to catch the present situation of librarianship and its backwardness. This paper can use for the grounds of an improvement of the librarian position in Korea. In order to improve current position classification of librarianship. we have to overcome a theoretical and actual weakness of the libraries and librarians and to act as the main stream for position reform.

  • PDF

The Design, Fabrication, and Characteristic Experiment for Control Rod Position Indicator Using Reed Switch in System-Integrated Modular Advanced Reactor (리드스위치를 이용한 일체형원자로용 제어봉 위치지시기 설계 제작 및 특성해석)

  • Hur, Hyung;Kim, Jong-In;Kim, Kern-Jung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.8
    • /
    • pp.452-461
    • /
    • 2003
  • The reliability and accuracy of the information on control rod position are very important to the reactor safety and the design of the core protection system. A survey on the RSPT(Reed Switch Position Transmitter) type control rod position indicator system and its actual implementation in the existing nuclear power plants in Korea was performed first. The control rod position indicator having the high performance for SMART was developed on the basis of RSPT technology identified through the survey. The arrangement of permanent magnet and reed switches is the most important procedure in the design of control rod position indicator. The hysteresis of reed switches is one of the important factors in a repeat accuracy of control rod position indicator as well. This paper investigates efficiency of the magnetic flux concentrator and the hysteresis using FEM and verified differences in physicals characteristics by comparing the results of FEM and those of the experiment. As a result, it is shown that the characteristics of prototype control rod position indicator have a good agreement with the results of FEM.