• 제목/요약/키워드: in-plane seismic performance

검색결과 60건 처리시간 0.023초

대각보강된 철근콘크리트 연결보의 변위비 기반 취약도 함수 개발 (Drift Ratio-based Fragility Functions for Diagonally Reinforced Concrete Coupling Beams)

  • 이창석;한상환;고혜영
    • 한국지진공학회논문집
    • /
    • 제23권2호
    • /
    • pp.131-140
    • /
    • 2019
  • Diagonally reinforced concrete coupling beams (DRCBs) have been widely adopted in reinforced concrete (RC) bearing wall systems. DRCBs are known to act as a fuse element dissipating most of seismic energies imparted to the bearing wall systems during earthquakes. Despite such importance of DRCBs, the damage estimation of such components and the corresponding consequences within the knowledge of performance based seismic design framework is not well understood. In this paper, drift-based fragility functions are developed for in-plane loaded DRCBs. Fragility functions are developed to predict the damage and to decide the repair method required for DRCBs subjected to earthquake loading. Thirty-seven experimental results are collected from seventeen published literatures for this effort. Drift-based fragility functions are developed for four damage states of DRCBs subjected to cyclic and monotonic loading associated with minor cracking, severe cracking, onset of strength loss, and significant strength loss. Damage states are defined in a consistent manner. Cumulative distribution functions are fit to the empirical data and evaluated using standard statistical methods.

보단부 회전형감쇠기를 이용한 대형구조물의 진동제어 (Vibration Control of Large Scale Structure with Beam-End Rotation Type Friction Damper)

  • 이상현;우성식;정란;조승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.452-458
    • /
    • 2007
  • The vertical extension of a building in general remodeling process increases both gravity and seismic loads by simply adding masses to the building. In this study, a vertical extension structural module (VESM) is proposed for enhancing seismic performance of the existing buildings by utilizing the story-increased parts. The proposed VESM is composed of steel column, steel beam, and beam-end rotational damper. The steel columns are connected to the shear walls and transfer the wall rotation in out-of plane to the steel beam, and then the beam-end rotational damper dissipates the earthquake-induced energy. Numerical analysis result from a cantilever beam of which end-rotation is restricted by rotational damper indicates that the displacement, base shear, and base overturning moment of the existing structures showing cantilever behavior can be significantly reduced by using the proposed method. Also, it is observed that friction-type rotational damper is effective than viscous one.

  • PDF

Seismic response control of irregular asymmetric structure with voided slabs by distributed tuned rotary mass damper devices

  • Shujin Li;Irakoze Jean Paula;Ling Mao
    • Earthquakes and Structures
    • /
    • 제25권6호
    • /
    • pp.455-467
    • /
    • 2023
  • This study focuses on demonstrating the effectiveness of vibration control of tuned rotary mass damper (TRMD) for reducing the bidirectional and torsional response of the irregular asymmetric structure with voided slabs under earthquake excitations. The TRMD arranged in plane of one-story eccentric structure is proposed as a distributed tuned rotary mass damper (DTRMD) system. Lagrange's equation is used to derive the equations of motion of the controlled system. The optimum position and number of TRMD are numerically investigated under harmonic excitation and the control effects of different distributions are discussed. Furthermore, a shaking table test is conducted under different excitation cases, including free vibration, forced vibration and seismic wave to investigate the absorption performance of the device. The numerical simulations of different distributions of the TRMDs show that the DTRMDs are more effective in reduction of the displacement response of the asymmetric structure under the same mass ratio, even when the degree of eccentricity becomes large. However, with small degree of eccentricity, the unreasonable asymmetrical arrangement may cause the increase of the peak value of the rotational angular displacement. Finally, the experimental investigations exhibit similar results of translational displacement of the structure. It is concluded that the vibration of the irregular asymmetric structure can be controlled more economically and effectively by reducing the mass ratio through reducing the quantity of TRMDs at the high stiffness end.

Knee - Brace를 활용한 비정형 필로티 건물의 내진보강방안에 대한 해석적 연구 (Analytical Study on the Seismic Retrofit Method of Irregular Piloti Building Using Knee-Brace)

  • 유석형;김달기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권1호
    • /
    • pp.35-42
    • /
    • 2020
  • 필로티 건물의 평면 비정형으로 인한 비틀림 거동은 비틀림 회전 최외단 기둥에 과도한 층간변위를 일으키고 이로 인하여 기둥의 전단파괴를 유도할 수 있다. 필로티 건물의 비틀림 거동을 제어할 수 있는 내진보강 공법으로서 벽체 증설, 철골 프레임 또는 철골 가새 추가공법 등이 사용될 수 있으나 이와 같은 공법 들은 필로티 층의 공간 개방성을 저해할 우려가 있다. 따라서 본 연구에서는 필로티 층의 공간 개방성을 유지할 수 있는 내진보강 공법으로서 knee brace를 활용하기 위하여 knee brace 보강재 단면 형상 및 보강재 설치 각도 등을 변수로 보강된 필로티 건물에 대하여 선형동적해석 및 비선형 정적해석(pushover analysis)을 수행하고 내진성능 평가 및 knee brace의 비틀림 제어효과를 분석하였다. 연구 결과 knee brace로 보강 시 기둥의 전단력은 증가하였으나 비틀림 변형을 제어하는데 효과가 있는 것으로 나타났다. knee brace와 기둥 사이를 30°로 보강 시 60°의 경우보다 기둥의 전단력은 적게 증가하였으며, 단면형상 □, ◯ 그리고 H 순으로 기둥의 횡변위가 적게 발생하였다.

Torsional effects in symmetrical steel buckling restrained braced frames: evaluation of seismic design provisions

  • Roy, Jonathan;Tremblay, Robert;Leger, Pierre
    • Earthquakes and Structures
    • /
    • 제8권2호
    • /
    • pp.423-442
    • /
    • 2015
  • The effects of accidental eccentricity on the seismic response of four-storey steel buildings laterally stabilized by buckling restrained braced frames are studied. The structures have a square, symmetrical footprint, without inherent eccentricity between the center of lateral resistance (CR) and the center of mass (CM). The position of the bracing bents in the buildings was varied to obtain three different levels of torsional sensitivity: low, intermediate and high. The structures were designed in accordance with the seismic design provisions of the 2010 National Building Code of Canada (NBCC). Three different analysis methods were used to account for accidental eccentricity in design: (1) Equivalent Static Procedure with static in-plane torsional moments assuming a mass eccentricity of 10% of the building dimension (ESP); (2) Response Spectrum Analysis with static torsional moments based on 10% of the building dimension (RSA-10); and (3) Response Spectrum Analysis with the CM being displaced by 5% of the building dimension (RSA-5). Time history analyses were performed under a set of eleven two-component historical records. The analyses showed that the ESP and RSA-10 methods can give appropriate results for all three levels of torsional sensitivity. When using the RSA-5 method, adequate performance was also achieved for the low and intermediate torsional sensitivity cases, but the method led to excessive displacements (5-10% storey drifts), near collapse state, for the highly torsionally sensitive structures. These results support the current provisions of NBCC 2010.

대각 보강된 HPFRCCs 커플링 보의 전단강도 및 설계 (Shear Strength and Design of HPFRCCs Coupling Beam with Diagonal Reinforcement)

  • 박완신;윤현도;김선우;전에스더;김용철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.257-260
    • /
    • 2006
  • Coupled shear walls consist of two or more in-plane walls inter-connected with coupling beams. In order to effectively resist seismic loads, coupling beams must be sufficiently stiff, strong and posses a stable load-deflection hysteretic response. Much of requirements to the civil and building structures have recently been changed in accordance with the social and economic progress. Ductility of high performance fiber reinforced cementitious composites(HPFRCCs), which exhibit strain hardening and multiple crackling characteristics under the uniaxial tensile stress is drastically improved. This paper provides background for design guidelines that include a design model to calculate the shear strength of pseudo strain hardening cementitious composite steel coupling beam.

  • PDF

진동대실험을 사용한 비보강 및 ECC 자켓 보강 조적담장의 내진성능평가 (Seismic Performance Evaluation of Unreinforced and ECC-jacketed Masonry Fences using Shaking Table Test)

  • 이용훈;김진우;김재환;엄태성;이상현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권6호
    • /
    • pp.182-192
    • /
    • 2023
  • 본 연구에서는 동적 횡하중을 받는 조적 담장의 내진성능 향상을 위한 ECC(Engineered Cementitious Composite) 자켓의 효과를 실험적으로 검증하였다. 첫째로, 임팩트 해머 시험을 통해 비보강과 ECC로 보강된 조적 담장의 고유진동수와 모드 감쇠비, 변형 형상을 식별하여, 940mm의 비보강 조적담장과 970mm의 ECC 보강 담장이 각각 6.4, 35.3Hz의 고유진동수와 7.0, 5.3%의 감쇠비를 가지는 것을 확인하였다. 둘째로, 진동대를 사용하여 면외방향에 대한 지진파 실험을 수행하였고, El Centro(1940) 지진파를 25%부터 300%까지 스케일링하여 적용하였다. 비보강 조적담장의 경우, 50% 지진하중에서 벽돌과 줄눈 경계에 휨균열이 발생하였고, 다시 30%로 스케일링된 지반운동에서 면외방향으로 전도파괴되었다. 반면에 ECC로 보강된 조적담장은 300%의 지진하중에서도 균열이나 손상 없이 강건한 성능을 유지하였다. 마지막으로, 25~300%의 지반운동에 의한 비보강과 ECC 보강 조적담장의 밑면전단력과 설계기준에 따른 밑면전단력을 비교 및 평가하였다. 그 결과, 재현주기 1,000년의 지진에 대해 비보강 조적담장이 붕괴될 위험이 있는 데 반해, ECC 보강 담장은 4,800년 주기의 지진에도 안전한 것으로 추정되었다.

비보강 조적벽체의 면내거동 해석 (Analysis on In-Plane Behavior of Unreinforced Masonry Walls)

  • 김장훈;권기혁
    • 한국지진공학회논문집
    • /
    • 제6권3호
    • /
    • pp.1-10
    • /
    • 2002
  • 비록 제한된 범위내에서나마 일련의 유한요소해석을 통하여 비보강 조적조 벽체의 면내방향 내진성능을 조사하였다. 이를 위하여 비보강 조적벽체는 연속체로 가정하여 등방성 평면응력요소로 취급하였으며, 비보강 조적조의 균열거동을 위하여 균열특성이 요소내에 분포하는 것으로 가정하는 분포균열모델을 사용하였다. 모두 70가지 서로 다른 경우의 비보강 조적벽체 모델을 해석하였는데, 축력비, 형상비 및 유효단면적비 등의 변수를 고려하였다. 해석결과 이들 변수가 비보강 조적벽체의 극한강도에 지대한 영향을 미치며 상호 작용하는 것으로 확인되었다. 비보강 조적벽체의 여러 가지 취성적 요인과 복합적인 파괴형태의 가능성을 감안하여 현재 우리 나라 규준에서 사용하고 있는 반응수정계수의 크기를 재고하여야 함이 지적되었다.

Ultimate shear strength prediction model for unreinforced masonry retrofitted externally with textile reinforced mortar

  • Thomoglou, Athanasia K.;Rousakis, Theodoros C.;Achillopoulou, Dimitra V.;Karabinis, Athanasios I.
    • Earthquakes and Structures
    • /
    • 제19권6호
    • /
    • pp.411-425
    • /
    • 2020
  • Unreinforced masonry (URM) walls present low shear strength and are prone to brittle failure when subjected to inplane seismic overloads. This paper discusses the shear strengthening of URM walls with Textile Reinforced Mortar (TRM) jackets. The available literature is thoroughly reviewed and an extended database is developed including available brick, concrete and stone URM walls retrofitted and subjected to shear tests to assess their strength. Further, the experimental results of the database are compared against the available shear strength design models from ACI 549.4R-13, CNR DT 215 2018, CNR DT 200 R1/2013, Eurocode 6 and Eurocode 8 guidelines as well as Triantafillou and Antonopoulos 2000, Triantafillou 1998, Triantafillou 2016. The performance of the available models is investigated and the prediction average absolute error (AAE) is as high as 40%. A new model is proposed that takes into account the additional contribution of the reinforcing mortar layer of the TRM jacket that is usually neglected. Further, the approach identifies the plethora of different block materials, joint mortars and TRM mortars and grids and introduces rational calibration of their variable contributions on the shear strength. The proposed model provides more accurate shear strength predictions than the existing models for all different types of the URM substrates, with a low AAE equal to 22.95%.

원심모형시험을 이용한 케이슨 안벽의 지진시 거동에 대한 수치해석 검증 (Verification of the Numerical Analysis on Caisson Quay Wall Behavior Under Seismic Loading Using Centrifuge Test)

  • 이진선;박태정;이문교;김동수
    • 한국지반공학회논문집
    • /
    • 제34권11호
    • /
    • pp.57-70
    • /
    • 2018
  • 본 논문에서는 항만구조물의 성능기반 내진설계 도입을 위해서 액상화를 포함하는 비선형 유효응력해석기법의 검증을 실시하였다. 중력식 케이슨안벽의 지진시 거동에 대해서 수치해석의 결과는 동적원심모형시험의 결과와 원형스케일로 직접 검증되었다. 중력식 안벽의 모형은 강성토조내에 지진시 과잉간극수압의 증가가 발생하는 포화 사질토 지반위에 조성되었으며, 원심가속도 60g하에서 높이 10m, 폭 6m의 케이슨 안벽을 묘사할 수 있다. 원심모형시험의 원형스케일과 동일하게 2차원 평면 변형율 조건하에서 비선형 유효응력 수치해석 모델을 구성하였다. 지반의 비선형 거동모델과 함께 Byrne의 액상화 모델을 사용하였으며, 경계요소를 적용하여 안벽과 지반의 분리거동을 묘사하였다. 검증결과, 안벽의 잔류변위를 포함하여 지반 및 안벽의 수평가속도와 안벽기초 하부 사질토 지반의 과잉간극수압 증가양상 모두 유사한 결과를 나타내었다.