• 제목/요약/키워드: in-line measurement system

검색결과 998건 처리시간 0.03초

반도체레이져를 이용한 온도 및 농도의 계측 (Temperature and Concentration measurement using Semi-conductor diode laser)

  • 정대헌;노동순;지전유이
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.168-174
    • /
    • 2000
  • A diode laser sensor system based on absorption spectroscopy techniques has been developed to measure $CO_2$ concentration and temperature non-intrusively in high temperature combustion environments using a 2.0 ${\mu}m$ DFB(Distributed Feedback) laser. Two optics was fabricated in pig-tail fashion and all optical components were implemented in a single box. The evolution of measurement sensitivity was done using test cell by changing sweep frequency and $CO_2$ concentration. Gas temperature was determined from the ratio of integrated line strengths. Species concentration was determined from the integrated line intensity and the measured temperature. The result show that the system has 2% error in wide operation frequency range and accuracy of $CO_2$ concentration was about 3%. The system was applied to measure temperature and concentration in the combustion region of a premixed $CH_4$ +air triangular flame. The measurement results of gas temperature agreed well with thermocouple results. Many considerations were taken into account to reduce optical noise, etalon effect, beam steering and base line matching problem. The evaluations results and actual combustion measurement demonstrate the practical and applicability for in-situ and real time combustion monitoring in a practical system.

  • PDF

마이크로프로세서를 이용한 R-R 구간 측정 (Measurement of R-R Intervals with a Microprocessor)

  • 박경수;이동하
    • 대한인간공학회지
    • /
    • 제4권2호
    • /
    • pp.3-10
    • /
    • 1985
  • This article developes a cost-effective on-line measurement system of R - R intervals in ECG. The system is composed of a R peak detector, a timer and an Apple II computer (a 6502 microprocessor and memories). The system measures the R - R intervals in msec and stores them in a disk, for off-line analysis. A circuit diagram of the R peak detector and programs for controlling the microprocessor are presented.

  • PDF

HFPD 검출법을 이용한 지중 케이블 실선로 진단 (Diagnosis of power cable system based on the HFPD detection at on-site)

  • 이전선;김충식;이동근;공충호;석광현;이경욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.97-100
    • /
    • 2004
  • HFPD(High Frequency Partial Discharge) measurement has been widely performed to diagnosis of cable system in the world although Korea just begin. The efficiency of measurement has been reported and proved by many researchers who are engaged in the diagnosis of high power apparatus. LG Cable has investigated the technology of diagnosis for cable system by means of PD measurement for 10 years. In this paper, PD measurement with portable device was performed to evaluate the quality of the 154kV transmission line and the 22.9kV XLPE cable line. Test results are shown that the HFPD detection technology is very attractive for the diagnosis of power cable system by high detection sensitivity at on-site.

  • PDF

제어 신호를 이용한 고속철도 전장품의 특성 및 고장 분석 (Characteristics and Fault Analysis of Electric Devices for High-Speed Railway using Control Signal)

  • 한영재
    • 한국전기전자재료학회논문지
    • /
    • 제19권12호
    • /
    • pp.1128-1133
    • /
    • 2006
  • The most important thing to secure safety and reliability of railway vehicles is to verify performance characteristics of equipments, and related companies or research institutes had many efforts to verify performances and functions of equipments synthetically and efficiently. KHST(Korean High Speed Train) has been developed by KRRI (Korea Railroad Research Institute). An electric railway system is composed of high-tech subsystems, among which main electric equipment such as transformers and converter are critical components determining the performance of rolling stock. We developed a measurement system for on-line test and evaluation of performances of KHST. The measurement system is composed of software part and hardware part. Perfect interface between multi-users is possible. A new method to measure temperature was applied to the ]measurement system. By using the system, fault diagnosis and performance evaluation of electric equipment in Korean High Speed Train was conducted during test running.

활선상태 접지특성 측정시스템 개발 (A Development of the Measuring System for Grounding Properties in Liveline)

  • 최남호;문영표;정재기;박강식;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.36-40
    • /
    • 2002
  • This paper presents the results of a investigation, a development of the measuring system for grounding properties in live-line. The importance of the grounding system and it's property has been increased with the development, enlarge in capacity, of electrical industry. Moreover, with the rapid growth of communication and precision industry, now, we should consider the grounding properties to ensure the stable and/or safe operation. But the conventional measuring system is not proper to measure the grounding properties of the system, voltage applied. So, in this investigation, we proposed a new method for live-line measurement and develope the system. And through the field test we could confirm the superior performance of th developed system.

  • PDF

한국 환경에 적합한 기동형 수중음향측정체계 운용 개념 연구 (Study on the Operational Concept of Underwater Acoustic Measurement System in Korean Sea)

  • 도경철;손권;최재용
    • 한국군사과학기술학회지
    • /
    • 제6권2호
    • /
    • pp.45-54
    • /
    • 2003
  • The radiated-noise of combat ship is very important in the point of detection and vulnerability assessment. Therefore several kind of underwater acoustic measurement method has been developed. This paper reviews the various measurement concepts and proposes a procedure to select the better one under consideration of measurement conditions. And this paper recommends the portable drift type, which has vertical line array, as the most efficient measurement method in Korean sea.

Novel Calibration Method for the Multi-Camera Measurement System

  • Wang, Xinlei
    • Journal of the Optical Society of Korea
    • /
    • 제18권6호
    • /
    • pp.746-752
    • /
    • 2014
  • In a multi-camera measurement system, the determination of the external parameters is one of the vital tasks, referred to as the calibration of the system. In this paper, a new geometrical calibration method, which is based on the theory of the vanishing line, is proposed. Using a planar target with three equally spaced parallel lines, the normal vector of the target plane can be confirmed easily in every camera coordinate system of the measurement system. By moving the target into more than two different positions, the rotation matrix can be determined from related theory, i.e., the expression of the same vector in different coordinate systems. Moreover, the translation matrix can be derived from the known distance between the adjacent parallel lines. In this paper, the main factors effecting the calibration are analyzed. Simulations show that the proposed method achieves robustness and accuracy. Experimental results show that the calibration can reach 1.25 mm with the range about 0.5m. Furthermore, this calibration method also can be used for auto-calibration of the multi-camera mefasurement system as the feature of parallels exists widely.

시운전시험을 통한 고속전철 전장품의 성능 특성 (A Study on Performance Characteristic of Electric Equipments for High Speed Train by on-Line Test)

  • 한영재;김석원;김기환;한성호;이수길;김종영;노애숙
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1404-1407
    • /
    • 2004
  • An electric railway system is composed of high-tech subsystems, among which main electric equipments such as transformers, converter and traction motors are critical components determining the performance of rolling stock. We developed a measurement system for on-line test and evaluation of performances of Korean High Speed Train. The measurement system is composed of software part and hardware part. Perfect interface between multi-users is possible. A new method to measure temperature was applied to the measurement system. By using the system, measurement and evaluation for the performance of electric equipments in Korean High Speed Train was conducted during test running.

  • PDF

산업플랜트용 서지 측정 분석 장치 개발 (Development of the Surge Measurement System for Low Voltage Power Line of Industrial Plants)

  • 김영진;김재형;장석훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1698-1699
    • /
    • 2007
  • This paper deals with the surge measurement system for low voltage power line of industrial plants. It consists of a capacitive divider, A/D conversion part, signal processing and control part. A FPGA and a DSP board were designed to fast signal processing and control. Also, in order to measure lightning surge and switching surge for a long time, data backup device was applied by using SD memory. A performance of the measurement system was verified through evaluation test using impulse calibration generator.

  • PDF

고압전력선 통신을 위한 임피던스 측정 및 정합 방안 연구 (Impedance Measurement and Matching Technique for Medium-Voltage Powerline Communication)

  • 이재조;유정훈;홍충선;이대영
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권5호
    • /
    • pp.345-352
    • /
    • 2004
  • Currently, high data rate PLC(Power Line Communications), up to 100 Mbps, which use frequency bandwidth between 2 MHz and 30 MHz is investigated very hard, and commercial PLC modem for low voltage powerline network (indoor) is coming soon into communication market. For the purpose of developing a fit communication system which has little distortion of signal and attenuation, it is surely necessary to know about channel environments of powerline. Especially, the impedance measurement of the powerline and impedance matching are very important. As is known, since medium-voltage powerline (22.9 ㎸) is still working, it is not so simple to measure the powerline impedance. In our study, a portable impedance measurement equipment is developed. It consists of coupling capacitor, a drain coil and impedance matching transformer. The equipment is easily connected to medium voltage line and impedance of power line is measured using a network analyzer. Also, measurement results are used for impedance matching of PLC signal. In fact, matching transformer with several different impedances are used. The matching transformer is connected between coupling capacitor and signal port. In this paper, the developed portable impedance measurement equipment and impedance measurement results are presented. Also impedance matching technique using matching transformers will be explained. We showed the result of the improved performance by the impedance matching.