• Title/Summary/Keyword: in-line coagulation

Search Result 32, Processing Time 0.02 seconds

A Novel Anticoagulant Protein with High Affinity to Blood Coagulation Factor Va from Tegillarca granosa

  • Jung, Won-Kyo;Jo, Hee-Yeon;Qian, Zhong-Ji;Jeong, Young-Ju;Park, Sae-Gwang;Choi, Il-Whan;Kim, Se-Kwon
    • BMB Reports
    • /
    • v.40 no.5
    • /
    • pp.832-838
    • /
    • 2007
  • A novel inhibitory protein against blood coagulation factor Va (FVa) was purified from muscle protein of granulated ark (Tegillarca granosa, order Arcoida, marine bivalvia) by consecutive FPLC method using anion exchange and gel permeation chromatography. In the results of ESI-QTOF tandem mass analysis and database research, it was revealed that the purified T. granosa anticoagulant protein (TGAP) has 7.7 kDa of molecular mass and its partial sequence, HTHLQRAPHPNALGYHGK, has a high identity (64%) with serine/threonine kinase derived from Rhodopirellula baltica (order Planctomycetales, marine bacteria). TGAP could potently prolong thrombin time (TT), corresponding to inhibition of thrombin (FIIa) formation. Specific factor inhibitory assay showed that TGAP inhibits FVa among the major components of prothrombinase complex. In vitro assay for direct-binding affinity using surface plasmon resonance (SPR) spectrometer indicated that TGAP could be directly bound with FVa. In addition, the binding affinity of FVa to FII was decreased by addition of TGAP in dose-dependant manner ($IC_{50}$ value = 77.9 nM). These results illustrated that TGAP might interact with a heavy chain of FVa ($FVa_H$) bound to FII in prothrombin complex. The present study elucidated that non-cytotoxic T. granosa anticoagulant protein (TGAP) bound to FVa can prolong blood coagulation time by inhibiting conversion of FII to FIIa in blood coagulation cascade. In addition, TGAP did not significantly (P < 0.05) show fibrinolytic activity and cytotoxicity on venous endothelial cell line (ECV 304).

Evaluation of Pilot scale Coagulation system Design for CSOs treatment (CSOs 처리를 위한 실증규모 응집침전시스템의 설계평가)

  • Lee, Seung-Chul;Ha, Sung-Ryong
    • Journal of Wetlands Research
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • A pilot scale coagulation system, which has a function of physicochemical treatment, was developed to treat Combined sewer overflows(CSOs). This coagulation system requires evaluation of optimum design factors whether it has reflected those of lab scale system, moreover, the pilot scale system can be evaluated differently according to the characteristics of influent CSOs even though it has reflected lab scale's design factors. We conducted an experiment using lab scale system that could treat $1m^3$ of CSOs in a day, and also pilot-scale system with $100m^3/day$ CSOs flowed into the Cheongju sewage treatment plant. Therefore the aim of this study is to evaluate a hydraulic similarity between the design factors of pilot scale and those of lab scale coagulation system, and to evaluate feasibility of the coagulation system for the CSOs treatment with optimum operation conditions. From the result of pilot-test, we drew the optimum operation factors of in line mixer and flocculator having similarities with those of lab scale system as well as the optimum coagulant dose. Finally we confirmed that the coagulation system has feasibility to treat the CSOs with high removal efficiency.

Evaluation of Flow Characteristics within In-Line Mixer for Water Treatment using CFD Technique (CFD모사 기법을 이용한 관내 혼화장치내 흐름 특성 평가)

  • Park, Dae-Jin;Park, Young-Oh;Park, No-Suk;Kim, Seong-Su;Wang, Chang-Kuen
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.351-358
    • /
    • 2008
  • The modified in-line mixer which was suggested in this study for small water treatment facilities was evaluated on the performance of coagulation. For the objectives of this research, computational fluid dynamics(CFD) simulation was applied for analysis of flow characteristics within the modified in-line mixer. For verifying the results of CFD simulation, wet tests for the pilot plant were conducted. The wet test was to measure the actual coagulant dispersion distribution on the overall cross-section at a distance of 5.5D from the chemical injection point. From the results of CFD simulation and wet test, it was shown that the coagulant dispersion within the modified in-line mixer was occurred more uniformly than within the existing PDM(Pump diffusion Mixer). The results have confirmed the modified in-line mixer had several advantages compared with the existing PDM in terms of dispersion efficiency.

Optimization of Chemical Coagulation for Wastewater Treatment in a Confectionery Factory (제과공장 폐수의 화학적 응집공정 최적화)

  • Keum, Seung-Hae;Chang, Kyu-Sub;Song, Kyung-Bin;An, Gil-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.318-323
    • /
    • 1995
  • To improve wastewater treatment in a confectionery factory and to optimize chemical coagulation process, this study was performed. $COD_{Mn}$ and total solid of untreated wastewater were $200{\sim}820ppm\;and\;860{\sim}1350ppm$, respectively. Composition of total solid was sugar 40%, protein 10%, hexane-soluble 20%, and ash 30%. Turbidity at 650 nm and the amount of suspended solid (SS) showed correlation, thus turbidity could be used for the on-line measurement of SS. The most effective combination of coagulants for the removal of $COD_{Mn}$ and SS was that of $Al_2(SO_4)_3\;and\;Ca(OH)_2$. The optimal concentration of $Al_2(SO_4)_3\;and\;Ca(OH)_2$ was 480 ppm and 200 ppm, respectively. Optimal retention time of wastewater for $Al_2(SO_4)_3$ addition $Ca(OH)_2$ addition : flocculation was 2 : 2 : 10 min. Multiple treatment of $Al_2(SO_4)_3:Ca(OH)_2$ overcame coagulation inhibition by gelatin and detergent, and addition of microbial sludge reduced it.

  • PDF

A Study on the Applicability of PDA Technique in the P-CAP System for T-P Removal of STP Effluent (하수처리장 방류수의 총인 제거를 위한 P-CAP 시스템에서 PDA 기법의 활용가능성에 대한 연구)

  • Choi, Choongho;Maeng, Sungkyu;Sim, Jaehwi;Choi, Jinho;Song, Kyungguen;Lee, Byungha;Cha, Hoyoung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.729-742
    • /
    • 2012
  • Recently, to using chemical coagulation process for T-P removal in STP effluent as tertiary treatment process is generalized in the country. The importance of analysis technique to save the treatment & maintenance cost during coagulation process is becoming more increased each day. Thus, it is necessary for the analysis technique during coagulation process to be presented well the characteristic of coagulation in field apply. There are a few analysis techniques such as Jar Test, zeta potential analysis and streaming current detecting techniques. But there are difficult to apply in field immediately due to long test time and difficult analysis techniques. And using PDA technique, it is reviewed applicability of the techniques as field index on pilot plant of P-CAP system The P-CAP system is composed of an in-line static mixer, a Flocculation Tank and the CAP reactor with 2 stage weir for effluent. Pre-test is performed to fix the mixing velocity in the Flocculation Tank using the PDA equipment and it fixed with 30RPM. Also, Jar Test is performed to select optimum dose of each coagulant for each T-P concentration level of influent. Result of continuous test on pilot plant of P-CAP system, the FSI in the Flocculation Tank is increased consistently by increasing each dosing concentration of coagulant such as LAS and PAC in the low level influent T-P concentration comparatively. It is considered that formed Al-hydroxide complexes for dosed coagulant are caused FSI variation. Furthermore, it seems that FSI value in the high level influent T-P concentration appeared lower than the opposite influent condition relatively because it is formed simultaneously Al-hydroxide complexes as solid type and Al-phosphorus complexes as soluble type. Thus, relation of FSI by PDA technique and T-P removal of final effluent on pilot plant of P-CAP system are very limited for the kind of coagulant and the characteristics of influent. And it though that FSI value by PDA technique with analyzing of turbidity in Flocculation Tank will be used restrictedly on field as the relative field-index.

Analysis of the cost effectiveness according to T-P standard enforcement of public sewage treatment facilities (공공하수처리시설의 총인기준 강화에 따른 비용효과분석)

  • Jeong, Won-Gu;Rim, Jay-Myung
    • Journal of Industrial Technology
    • /
    • v.31 no.A
    • /
    • pp.135-145
    • /
    • 2011
  • This study was conducted to analyze the cost effectiveness in line with total phosphorus standard enforcement of public sewage treatment facilities. The additional cost for the total phosphorus removal process was calculated to analyze the cost effectiveness of the advanced water purification process. The analysis results showed that the T-P removal by coagulation sedimentation was more efficient than the advanced water purification facilities in terms of facilities investment cost, and if the coagulation filteration was used for T-P removal, the activated carbon process among the advanced water purification techniques was more efficient in terms of facilities investment cost. In this study, the effects of the T-P removal process that will be additionally introduced according to the tightening of the effluent T-P standard were analyzed within a limit. The actual benefits of improved T-P concentration in the water source will provide diverse values, including the leisure water, environment improvement water, eco-system in the water source and industrial water, in addition to the advanced water purification.

  • PDF

Development of Water Reusing System by Using Net3FM (Net Fit Fiber Filter Module) (그물망 압착식 섬유여과장치를 이용한 물 재이용 시스템 개발)

  • Kim, Jeongsook;Kim, Mi-Ran;Jo, Myung-Chan;Jang, Jeong-Gook
    • Journal of Environmental Science International
    • /
    • v.21 no.12
    • /
    • pp.1523-1528
    • /
    • 2012
  • This study was carried out to develop pilot plant Net3FM(Net Fit Fiber Filter Module) system and to suggest optimum operating condition for municipal wastewater reuse. SS concentration of biologically treated sewage effluent was reduced from 1.5~5.4mg/L to 0.4~1.0mg/L without coagulant injection in Net3FM system, and the SS removal efficiency was average 84.7%. And also, the removal efficiencies of COD and T-P were decreased slightly due to the SS removal by filtration. Coagulation-Filtration test was conducted to enhance the removal efficiencies of SS and T-P. The optimum dosage of coagulant was injected automatically by auto-controlling system, which is controlled by detecting value of turbidity of secondary sewage effluent. SS, COD and T-P concentrations in filtrated effluent were 0.21~0.57, 1.6~6.2 and 0.137~0.392mg/L with coagulant injection by in-line mixer in Net3FM system, respectively. The removal efficiencies of SS and T-P were highly increased to 92.8% and 89.8%, respectively. It was due to the combined the processes of coagulation and filtration. Net3FM system was evaluated that the removal efficiency of pollutants in secondary sewage effluent and the utilization potential as reclaimed water technology were very high.

A study on the inflammatory response induced by LPS of the Arthrospira platensis ethanol extract

  • Zhang, Shi Jie;Yang, Jae-Chan;Kim, Bo-Ae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.966-974
    • /
    • 2019
  • Arthrospira platensis has been reported to contain a variety of substances such as phycocyanin, ${\beta}$-carotene, vitamin E and other carotenoids. In this study, zebrafish were treated with indoor cultivation spirulina ethanol extracts(ICAE) to determine toxicity(coagulation rate, hatching rate, heart rate). We used the DCFH-DA staining method to detect the effect of reactive oxygen species(ROS) generation on lipopolysaccharide(LPS)-induced zebrafish embryos ROS various concentrations(0.01, 0.05, 0.1, 0.5mg/ml) of ICAE. Cell toxicity was measured by WST-1 assay on RAW 264.7 macrophage cell line. Also, measured the inhibitory effect of nitric oxide(NO) and prostaglandin $E_2$ ($PGE_2$) production in RAW264.7 macrophages induced by LPS at various concentrations of ICAE. The results of embryo coagulation rate, hatching rate, heart rate of zebrafish at various(0.01, 0.05, 0.1mg/ml) of ICAE was no toxicity. The ICAE treated group had an inhibitory effect on NO and $PGE_2$ production compared and decreased with concentration. The results of this study ethanol extract of Arthrospira platensis has an anti-inflammatory effect and suggest that is worthy of use cosmetics for skin protection.

Cause of Filtrate Deterioration and Its Improvement in Rapid Filtration (급속여과공정에서 여과수질 저하원인 및 개선방안)

  • Kim, Jin-Keun;Lee, Song-Hee;Kim, Jae-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.3
    • /
    • pp.333-339
    • /
    • 2010
  • Particle removal is an important step taken at water treatment plants (WTPs) for the safety of tap water due to its proportionality to the pathogen inactivation. Government promulgated a treatment technique for the optimization of filtration including continuous turbidity monitoring using on-line turbidimeters. Based on the turbidity measurements of 460 filters at 31 WTPs operated by K-water, the evaluation of filtration performance and the investigation of major causes related to particle breakthrough were explored. 98.1 % of the filters had an effluent turbidity measurement which was less than 0.1 NTU, but turbidity breakthrough of more than 0.3 NTU was noticed occasionally which is in violation of AWWA 5-Star guidelines. It was shown that the optimization of coagulation, filter-to-waste, the observance of optimal filtration velocity and backwashing process based on filtrate turbidity were crucial for the improvement of filtrate.

On-line Monitoring of the Flocs in Mixing Zone using iPDA in the Drinking Water Treatment Plant (정수장 응집혼화공정에서의 응집플럭 연속 모니터링)

  • Ga, Gil-Hyun;Jang, Hyun-Sung;Kim, Young-Beom;Kwak, Jong-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.4
    • /
    • pp.263-271
    • /
    • 2009
  • This study evaluated the flocs forming characteristics in the mixing zone to increase the coagulation effect in the drinking water plant. As a measuring tool of formed flocs, on-line particle dispersion analyzer (iPDA) was used in Y drinking water plant. To evaluate the forming flocs, many parameters such as poly amine, coagulant dosing amount, raw water turbidity, and pH was applied in this study. During the periods of field test, poly aluminium chloride (PACl) as a coagulant was used. With the increase of the raw water turbidities, poly amine was also added as one of aids for increasing in coagulation efficiency. The turbidity and pH of raw water was ranged from 7 to 9 and from 25 to 140 NTU, respectively. The increasing of raw water turbidity brought the bigger floc sizes accordingly. From a regression analysis, $R^2$ value was 0.8040 as a function of T, raw water turbidity. Floc size index (FSI) was obtained from a correlation equation as follows; FSI = 0.9388logT - 0.3214 Also, polyamine gave the bigger flocs the moment it is added to the coagulated water in the rapid mixing zone. One of parameters influencing the floc sizes was the addition of powdered active carbon(PAC) in the mixing zone. In case of higher turbidity of raw water, $R^2$ value was 0.9050 in the parameters of [PACl] and [PAC]; FSI = $0.0407[T]^{0.324}[PACI]^{0.769}[PAC]^{0.178}$ On-line floc monitor was beneficial to evaluate the flocs sizes depending on the many parameters consisting raw water properties, bring the profitable basic data to control the mixing zone more effectively.