• Title/Summary/Keyword: in vivo측정

Search Result 627, Processing Time 0.027 seconds

In vitro and in vivo Responses of MFO Systems in Olive Flounder (Paralichthys olivaceus) Exposed to TBT and TPT for Short-term Period (유기주석화합물에 단기간 노출시킨 넙치 간장 약물대사효소의 in vivo 및 in vitro 반응)

  • 전중균;이지선;전미정;심원준;임한규
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.1
    • /
    • pp.177-183
    • /
    • 2004
  • Cytochrome P45O (CYP) contents and 7-ethoxyresorufin-O-deethylase (EROD) activity were determined in hepatic microsome of olive flounder (Paralichthys olivaceus) exposed to tributyltin chloride (TBTC), tributyltin oxide (TBTO), and triphenyltin chloride (TPTC). In addition, effects of in vivo (intraperitoneal injection of 7.5 mg $kg^{-1}$ BW) exposure of flounder to TPTC on CYP, NADPH cytochrome c reductase, NADH cytochrome b5 yeductase and EROD levels were measured. In in vitro exposure of hepatic microsome to organotins, TBTC, TBTO and TPTC reduced CYP contents and inhibited EROD activity. The TPTC was the strongest inhibitor, which is followed by TBTO and TBTC. The degree of inhibition, especially EROD acitivity, depended on the exposure duration. In addition, all the target enzymes in flounder were inhibited by TPTC with the in vivo exposure to TPTC. As EROD activity was the most sensitive to the inhibitions and demonstrated good reproducibility of the results, it could be used as a helpful tool toy monitor effects of organotin compounds on mixed funciton oxygenase system in marine fish.

Phantom Glucose Measurement by Near Infrared Reflection (근적외선 반사를 이용한 인체 팬텀의 글루코즈 농도 측정)

  • 전계진;황인덕;조혜민;한상준;윤길원
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.250-251
    • /
    • 2002
  • 혈당의 비침습적인 측정의 필요성은 잦은 채혈로 인한 감염의 우려, 필요할 때마다 채혈의 고통 없이 혈당을 측정할 수 있다는 장점 때문에 지난 20여 년 동안 활발히 연구되어 왔다. 근적외선 및 원적외선 흡수분광법, 라만분광법, Polarization rotation 또는 Stimulated Raman 측정법, 온도측정법, 통계적 분석법, 전처리연구 등 많은 분야에서 접근하고 있지만 아직까지는 in vivo 측정에 성공하고 있지 못하고 있다 [1]. (중략)

  • PDF

Measurement of Skin Dose for Rectal Cancer Patients in Radiotherapy using Optically Stimulated Luminescence Detectors (OSLDs) (광자극발광선량계(OLSDs)를 이용한 직장암 방사선치료 환자의 피부선량 측정)

  • Im, In-Chul;Yu, Yun-Sik;Lee, Jae-Seung
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.86-92
    • /
    • 2011
  • This study used the optically stimulated luminescence dosimeters (OSLDs), recently, received the revaluation of usefulness in vivo dosimetry, and the diode detecters to measure the skin dose of patient with the rectal cancer. The measurements of dose delivered were compared with the planned dose from the treatment planning system (TPS). We evaluated the clinical application of OSDs in radiotherapy. We measured the calibration factor of OSLDs and used the percent depth dose to verified, also, we created the three point of surface by ten patients of rectal cancer to measured. The calibration factors of OSLD was 1.17 for 6 MV X-ray and 1.28 for 10 MV X-ray, demonstrating the energy dependency of X-ray beams. Comparison of surface dose measurement using the OSLDs and diode detectors with the planned dose from the TPS, The skin dose of patient was increased 1.16 ~ 2.83% for diode detectors, 1.36 ~ 2.17% for OSLDs. Especially, the difference between planned dose and the delivery dose was increased in the perineum, a skin of intense flexure region, and the OSLDs as a result of close spacing of measuring a variate showed a steady dose verification than the diode detecters. Therefore, on behalf of the ionization chamber and diode detecters, OSLDs could be applied clinically in the verification of radiation dose error and in vivo dosimety. The research on the dose verification of the rectal cancer in the around perineal, a surface of intense flexure region, suggest continue to be.

Measurement of Dynamic Viscoelasticity of In-vivo Human Skin (In-vivo 피부의 동적 점탄성 측정)

  • Kwon H.J.;Kwon Y.H.;Jeong C.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.525-526
    • /
    • 2006
  • The products designed by human sensibility and ergonomics are given good impression. Especially the touch feeling on the human skin is very useful sensibility for quality of products. Elasticity and viscosity of human skin is very important element in product design based on ergonomics. In this paper, we describe a sophisticated method for measurement of dynamic viscoelasticity characteristics of human skin. For this measurement, we developed a measurement system assembled with load cell, actuator, amplifier and data acquisition system. The $MATLAB^{TM}$ is used to analyze the data and fit a approximation curves.

  • PDF

A study on correlation between frictional coefficients and subjective evaluation while rubbing cosmetic product on skin (화장품을 바를 때 피부 마찰계수의 변화와 주관적인 평가와의 상관관계 연구)

  • Kwon Young-Ha;Kwon Hyun-Joon;Rang Moon-Jeong;Lee Su-Min
    • Science of Emotion and Sensibility
    • /
    • v.8 no.4
    • /
    • pp.385-391
    • /
    • 2005
  • A frictional coefficients of in-vivo skin characteristic is the most important factor of the cutaneous mechanical properties ant the method of evaluating skin care in the fields of cosmetics products. In-vivo skin characteristic varies in many different ways depends on what is applied to the skin, loading condition, shape, surface roughness, and material of the probe. In this research, we designed a system which can be measured frictional coefficients of a human skin on real time. It consists of multi-components load-cell, actuator, linear motor and arm fixator. This measurement system was automatically controlled by computer. We measured frictional coefficients between probe an4 skin using this system ant inquired adjectives for subjective evaluation while rubbing cosmetic product on skin. Lastly, we analyzed correlation between two factors by calculating Pearson Correlation Coefficient. As a result, we could know that frictional coefficients varied from 0.17-1.2 according to cosmetic products, normal forte, materials and surface conditions of probe. We also confirmed sensual feelings of cosmetic products have close correlation with frictional coefficients.

  • PDF

Studies on the evaluation of efficacy of functional cosmetics(I) -Studies on the in vitro SPF test method of sunscreen products (기능성화장품의 기능성평가에 관한 연구(I) -자위선차단화장품의 in vitro 시험법 연구)

  • 손경훈;김영옥;이정표;양성준;백옥진;김원희;김종갑;허문영;최상숙
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.28 no.3
    • /
    • pp.171-184
    • /
    • 2002
  • The present study was undertaken to develop the in vitro sunprotection factor(SPF) measurement method having good correlation with in vivo method. As in vitro method, 8% homomentyl salicylate, P3 reference standard and sunscreens on market were measured using SPF 290 analyzer and were compared the SPF with labed value. In vitro SPF of 8% HMS and P3 reference standard were 4.59 $\pm$ 0.12 and 14.94 $\pm$ 0.83. There are good correlation, correlation factor were 0.9506 and 0.9769 respectively, between the in vitro and in vivo SPF for the sunscreen creams and lotions examined. Correlation factors of makeup base & liquid goundation, lotion labled with “shake before use”, compact powder were 0.8812, 0.8632 and 0.5984. The best sample applied method of compact powder was 1:0.8 mixture with cream base. These results suggest that the in vitro test method could be used as an alternative method for SPF.

The Use of MTT Assay, In Vitro and Ex Vivo, to Predict the Radiosensitivity of Colorectal Cancer (In-vitro와 Ex-vivo MTT Assay를 통한 직장암의 방사선치료 감수성 예측 가능성 검증)

  • Kim, Ji-Eun;Kim, Mi-Sook;Kang, Chang-Mo;Kim, Jong-Il;Shin, Hye-Kyung;Choi, Chul-Won;Seo, Young-Seok;Ji, Young-Hoon
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.166-172
    • /
    • 2008
  • Purpose: The measurement of radiosensitivity of individuals is useful in radiation therapy. Unfortunately, the measurement of radiation survival using a clonogenic assay, which is the established standard, can be difficult and time consuming. The aim of this study is to compare radiosensitivity results obtained from the MTT and clonogenic assays, and to evaluate whether the MTT assay can be used on clinical specimens. Materials and Methods: HCT-8, LoVo, CT-26, and WiDr were the colon cancer cell lines used for this study. The clonogenic assay was performed to obtain the cell survival curves and surviving fractions at a dose of 2 Gy ($SF_2$) as the standard technique for radiosensitivity. Also, the MTT assay was performed for each of the cell lines (in vitro). To simulate clinical specimens, the cell lines were inoculated into nude mice, removed when the tumors reached 1 cm in diameter, and chopped. Next, the tumors were subjected to the same process involved with the MTT assay in vitro. The inhibition rates (IR) of 10 Gy or 20 Gy of irradiation for in vitro and ex vivo were calculated based on the optical density of the MTT assay, respectively. Results: According to $SF_2$ and the cell survival curve, the HCT-8 and WiDr cell lines were more resistant to radiation than LoVo and CT-26 (p<0.05). The IR was measured by in vitro. The MTT assay IR was 17.3%, 21%, 30% and 56.5% for the WiDr, HCT-8, LoVo and CT-26 cell lines, respectively. In addition, the IR measured ex vivo by the MTT assay was 23.5%, 26%, 38% and 53% in the HCT-8, WiDr, LoVo and CT-26 tumors, respectively. Conclusion: The radiosensitivity measured by the MTT assay was correlated with the measures obtained from the clonogenic assay. This result highlights the possibility that the MTT assay could be used in clinical specimens for individual radiosensitivity assays.

Improvement of in vitro Sun Protection Factor Measurement (In vitro SPF 측정법 개선에 관한 연구)

  • 안성연;배지현;이해광;문성준;장이섭
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.1
    • /
    • pp.129-133
    • /
    • 2004
  • The major advantage of the in vitro test is that it is a rapid, objective and cost-effective screening methodology. In vitro tests can provide a formulation tool to identify new fillers that are optimized by combinations of old ones and they can be used to pre-screen protective formulas prior to in vivo testing in humans. Therefore, the accuracy of in vitro SPF measurement is very important. In this study, improvement of application method of samples was tried to improve the accuracy of in vitro SPF measurement. The outer part of Transpore$\^$(R)/ tape was used to apply samples as the substrates and the standard drying time was set at 15 min. The new method, topical applications at light scan areas, results in more accurate and reliable results. This result suggests that more accurate prediction system can be established for in vivo SPF with in vivo SPF measurement.

A Study on the Analysis of Ciliary Beat Frequency in Human Respiratory Tract n Vivo (레이저 산란 기법을 이용한 인체 기도 내 섬모 운동 신호의 분석에 관한 연구)

  • 이원진;이재서;이재서;이철희;권태영
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.339-344
    • /
    • 2000
  • The mucociliary system is one of the most important airway defense mechanisms in human body and impairment of ciliary movement results in various diseases in respiratory tract. In this study, we have developed a system that can measure ciliary movement in vivo and quantified ciliary beat frequency (CBF) through autoregressive (AR) power spectrum. To measure the frequency in vivo, we applied a photoelectric method that was composed of a laser light and a fiber optic probe. Scattered signals are transferred to a PC in which they are displayed on the monitor and its CBF is determined by the AR method in were acquired. For 8 normal subjects, the analyzed CBFs ranged from 5 to 10Hz and its mean was 7.3${\pm}$1.1Hz. This result showed similar aspects to the reported results of CBFs to data. We expect that this result will be applied in various clinical studies such as analysis of CBF changes by drugs or by diseaes.

  • PDF