• Title/Summary/Keyword: improved type

Search Result 4,740, Processing Time 0.041 seconds

Comparison of Doses of Single Scan PBS and Layered Rescanning PBS Using Moving Phantom in Proton Therapy (양성자 치료에서 Moving Phantom을 이용한 Single Scan PBS와 Layered Rescanning PBS의 선량비교)

  • Kim, Kyeong Tae;Kim, Seon Yeong;Kim, Dae Woong;Kim, Jae Won;Park, Ji Yeon;Jeon, Sang Min
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose : We apply the Layered Rescanning PBS designed to complement the Pencil Beam Scanning(PBS), which is vulnerable to moving organs with the Moving Phantom, and compare the homogeneity with the single scan PBS. Methods and materials: Matrix X (IBA, Belgium) and Moving Phantom (standard imaging, USA) were used. A dose of 200 cGy was measured in the AP direction on a hypothetical tumor $10{\times}10{\times}5cm$. The plan type was planned as 4 kinds of sinlge scan PBS, rescan number 4, 8, 12 times. Were measured three times for each types. During the measurement, the respiratory cycle of the Moving Phantom was generally set to 4 seconds per cycle, and the movement radius in the S-I direction was set to 2 cm. In addition, beam on time was measured. Results : The mean values of $D_{max}$ in the PTV were $246.47{\pm}18.8cGy$, $223.43{\pm}8.92cGy$, and $222.47{\pm}7.7cGy$, $213.9{\pm}6.11cGy$ and the mean values of $D_{min}$ were $165.53{\pm}4.32cGy$, $173.13{\pm}11.94cGy$, $184.13{\pm}8.04cGy$, $182.67{\pm}4.38cGy$ and the mean values of $D_{mean}$ $192.77{\pm}6.98cGy$, $196.7{\pm}4.01cGy$, $198.17{\pm}4.96cGy$, $195.77{\pm}3.15cGy$ respectively. As the number of rescanning increased, the Homogeneity Index converged to 1. The beam on time was measured as 2:15, 3:15, 4:30, 5:37 on average. In the measurement process, in the low dose layer of the MU, the problem was found that it was not rescanned as many times as the set number of rescan. Conclusions : In the treatment of tumors with long-term movements, the application of layered rescanning PBS showed a more uniform dose distribution than single scan PBS. And as the number of rescan increase, the distribution of homogeneity is uniform. Compared with single scan plan and 12 rescan plan, HI value was improved by 0.32. Further studies are expected to be applicable to patients who can not be treated with respiratory synchronous radiation therapy.

Anomaly Detection for User Action with Generative Adversarial Networks (적대적 생성 모델을 활용한 사용자 행위 이상 탐지 방법)

  • Choi, Nam woong;Kim, Wooju
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.3
    • /
    • pp.43-62
    • /
    • 2019
  • At one time, the anomaly detection sector dominated the method of determining whether there was an abnormality based on the statistics derived from specific data. This methodology was possible because the dimension of the data was simple in the past, so the classical statistical method could work effectively. However, as the characteristics of data have changed complexly in the era of big data, it has become more difficult to accurately analyze and predict the data that occurs throughout the industry in the conventional way. Therefore, SVM and Decision Tree based supervised learning algorithms were used. However, there is peculiarity that supervised learning based model can only accurately predict the test data, when the number of classes is equal to the number of normal classes and most of the data generated in the industry has unbalanced data class. Therefore, the predicted results are not always valid when supervised learning model is applied. In order to overcome these drawbacks, many studies now use the unsupervised learning-based model that is not influenced by class distribution, such as autoencoder or generative adversarial networks. In this paper, we propose a method to detect anomalies using generative adversarial networks. AnoGAN, introduced in the study of Thomas et al (2017), is a classification model that performs abnormal detection of medical images. It was composed of a Convolution Neural Net and was used in the field of detection. On the other hand, sequencing data abnormality detection using generative adversarial network is a lack of research papers compared to image data. Of course, in Li et al (2018), a study by Li et al (LSTM), a type of recurrent neural network, has proposed a model to classify the abnormities of numerical sequence data, but it has not been used for categorical sequence data, as well as feature matching method applied by salans et al.(2016). So it suggests that there are a number of studies to be tried on in the ideal classification of sequence data through a generative adversarial Network. In order to learn the sequence data, the structure of the generative adversarial networks is composed of LSTM, and the 2 stacked-LSTM of the generator is composed of 32-dim hidden unit layers and 64-dim hidden unit layers. The LSTM of the discriminator consists of 64-dim hidden unit layer were used. In the process of deriving abnormal scores from existing paper of Anomaly Detection for Sequence data, entropy values of probability of actual data are used in the process of deriving abnormal scores. but in this paper, as mentioned earlier, abnormal scores have been derived by using feature matching techniques. In addition, the process of optimizing latent variables was designed with LSTM to improve model performance. The modified form of generative adversarial model was more accurate in all experiments than the autoencoder in terms of precision and was approximately 7% higher in accuracy. In terms of Robustness, Generative adversarial networks also performed better than autoencoder. Because generative adversarial networks can learn data distribution from real categorical sequence data, Unaffected by a single normal data. But autoencoder is not. Result of Robustness test showed that he accuracy of the autocoder was 92%, the accuracy of the hostile neural network was 96%, and in terms of sensitivity, the autocoder was 40% and the hostile neural network was 51%. In this paper, experiments have also been conducted to show how much performance changes due to differences in the optimization structure of potential variables. As a result, the level of 1% was improved in terms of sensitivity. These results suggest that it presented a new perspective on optimizing latent variable that were relatively insignificant.

A study on non-existence information of the information disclosure system : focused on the central administrative agencies (정보공개제도상의 정보부존재에 관한 고찰 중앙행정기관을 중심으로)

  • Kim, You-seung;Choi, Jeong Min
    • The Korean Journal of Archival Studies
    • /
    • no.46
    • /
    • pp.153-187
    • /
    • 2015
  • This study aims to discuss issues about non-existent information of the information disclosure system and to provide alternative strategies for the issues. For the theoretical discussion it reviews the definitions and standards of non-existent information and analyzes legal aspects and statistical changes of non-existent information. Furthemore, in order to discuss a current status and problems of non-existent information at the central administrative agencies, it analyzes the cases of the non-existent information notification. According to analysis results, non-existent information status of the surveyed institutions is a total of 4,421 cases for three years and it shows the continuous increasing trend year after year. The number of institutions that have the number of non-existent information equal to the number of nondisclosures or over it reached about 40%. It means excluding non-existent information from the reasons of nondisclosure influenced disclose rates and nondisclosure rates of many agencies. In the type analysis of the non-existent information reasons, the most main reason, the case of not producing or receiving the requested information by public institutions takes over 75% among the whole reasons. The next reason is the case of collecting or processing information takes over 7-10%. This study found the operational issues, as analyzing notifications of non-existent information. The operational issues are 1) the incomplete explanation of non-existent information, 2) the unclear scope of the collection and processing, 3) the problem of the transfer processing, and 4) the problem of recording management. Therefore, this study suggested some improvements of the perspective and the technical and procedural aspects. First, information disclosure issues including non-existent information are to be understood as an extension of records management. Second, disclosure service should improve overall based on advanced understanding. Third, the management procedures of non-existent information should be improved. Fourth, specific guidelines for handling non-existent information should be developed.

The Study on the Embedded Active Device for Ka-Band using the Component Embedding Process (부품 내장 공정을 이용한 5G용 내장형 능동소자에 관한 연구)

  • Jung, Jae-Woong;Park, Se-Hoon;Ryu, Jong-In
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.3
    • /
    • pp.1-7
    • /
    • 2021
  • In this paper, by embedding a bare-die chip-type drive amplifier into the PCB composed of ABF and FR-4, it implements an embedded active device that can be applied in 28 GHz band modules. The ABF has a dielectric constant of 3.2 and a dielectric loss of 0.016. The FR-4 where the drive amplifier is embedded has a dielectric constant of 3.5 and a dielectric loss of 0.02. The proposed embedded module is processed into two structures, and S-parameter properties are confirmed with measurements. The two process structures are an embedding structure of face-up and an embedding structure of face-down. The fabricated module is measured on a designed test board using Taconic's TLY-5A(dielectric constant : 2.17, dielectric loss : 0.0002). The PCB which embedded into the face-down expected better gain performance due to shorter interconnection-line from the RF pad of the Bear-die chip to the pattern of formed layer. But it is verified that the ground at the bottom of the bear-die chip is grounded Through via, resulting in an oscillation. On the other hand, the face-up structure has a stable gain characteristic of more than 10 dB from 25 GHz to 30 GHz, with a gain of 12.32 dB at the center frequency of 28 GHz. The output characteristics of module embedded into the face-up structure are measured using signal generator and spectrum analyzer. When the input power (Pin) of the signal generator was applied from -10 dBm to 20 dBm, the gain compression point (P1dB) of the embedded module was 20.38 dB. Ultimately, the bare-die chip used in this paper was verified through measurement that the oscillation is improved according to the grounding methods when embedding in a PCB. Thus, the module embedded into the face-up structure will be able to be properly used for communication modules in millimeter wave bands.

A study on the effect of collimator angle on PAN-Pelvis volumetric modulated arc therapy (VMAT) including junction (접합부를 포함한 PAN-전골반암 VMAT 치료 계획 시 콜리메이터 각도의 영향에 관한 고찰)

  • Kim, Hyeon Yeong;Chang, Nam Jun;Jung, Hae Youn;Jeong, Yun Ju;Won, Hui Su;Seok, Jin Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.61-71
    • /
    • 2020
  • Purpose: To investigate the effect of collimator angle on plan quality of PAN-Pelvis Multi-isocenter VMAT plan, dose reproducibility at the junction and impact on set-up error at the junction. Material and method: 10 adult patients with whole pelvis cancer including PAN were selected for the study. Using Trubeam STx equipped with HD MLC, we changed the collimator angle to 20°, 30°, and 45° except 10° which was the default collimator angle in the Eclipse(version 13.7) and all other treatment conditions were set to be the same for each patient and four plans were established also. To evaluate these plans, PTV coverage, coverage index(CVI) and homogeneity index (HI) were compared and clinical indicators for each treatment sites in normal tissues were analyzed. To evaluate dose reproducibility at the junction, the absolute dose was measured using a Falmer type ionization chamber and dose changes at the junction were evaluated by moving the position of the isocenter in and out 1~3mm and setting up the virtual volume at the junction. Result: CVI mean value was PTV-45 0.985±0.004, PTV-55 0.998±0.003 at 45° and HI mean value was PTV-45 1.140±0.074, and PTV-55 1.031±0.074 at 45° which were closest to 1. V20Gy of the kidneys decreased by 9.66% and average dose of bladder and V30 decreased by 1.88% and 2.16% at 45° compared to 10° for the critical organs. The dose value at the junction of the plan and the actual measured were within 0.3% and within tolerance. At the junction, due to set-up error the maximum dose increased to 14.56%, 9.88%, 8.03%, and 7.05%, at 10°, 20°, 30°, 45°, and the minimum dose decreased to 13.18%, 10.91%, 8.42%, and 4.53%, at 10°, 20°, 30°, 45° Conclusion: In terms of CVI, HI of PTV and critical organ protection, overall improved values were shown as the collimator angle increased. The impact on set-up error at the junction by collimator angle decreased as the angle increased and it will help improve the anxiety about the set up error. In conclusion, the collimator angle should be recognized as a factor that can affect the quality of the multi-isocenter VMAT plan and the dose at the junction, and be careful in setting the collimator angle in the treatment plan.

Changes in Characteristics of Semi-cured Pig Manure Liquid Fertilizer according to the Storage Duration and Aeration (반부숙상태 돈분뇨 액비의 저장기간 및 폭기여부에 따른 특성 변화)

  • Jeong, Kwang-Hwa;Park, Hoe-Man;Lee, Dong-Jun;Kim, Jung-Kon;Kim, Hyunjong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.4
    • /
    • pp.109-122
    • /
    • 2022
  • Currently, most of the pig manure generated from pig farms in Korea is in the form of a slurry with a moisture content of about 97%. Pig manure slurry is a mixture of pig manure and cleaning water in the pig house. In this study, changes in properties of pig manure liquid fertilizer according to whether air was supplied or not and with the passage of storage period were analyzed for 120 days. During the experimental period, the degree of maturity of the pig manure liquid fertilizer was higher in the experimental closed batch reactors supplied with air than in the same type reactors not supplied with air. As the liquid fertilizer storage period elapsed, there was a tendency that liquid fertilizer was converted to a state of complete maturity. In the batch reactor in which air was supplied, the moisture content of pig manure slurry, which had a moisture content of 97.90%, was reduced to 96.82% at the end of the experiment. On the other hand, the moisture content in the reactor without air was reduced to 97.33%. The pH of the liquid fertilizer, which was 8.82 at the start of the experiment, changed to 7.57 in the reactor with air supplied and 8.75 in the reactor without air at the completion of the experiment. The nitrogen content in the liquid fertilizer was 0.198 mg/L on average at the start of the experiment and it was lowered to 0.076 mg/L in the air supplied reactor at the end of the experiment. On the other hand, the nitrogen content of the liquid fertilizer was lowered to 0.121 mg/L in the reactor to which air was not supplied. The phosphoric acid (P2O5) concentration in the liquid decreased higher in the liquid fertilizer filled in the reactor without air than the liquid fertilizer filled in the reactor with air supplied as the storage period elapsed. Considering the experimental results, it is considered that the quality of pig manure liquid fertilizer is improved when air is supplied to pig manure slurry and the storage period of pig manure slurry is longer.

Study on the Multilevel Effects of Integrated Crisis Intervention Model for the Prevention of Elderly Suicide: Focusing on Suicidal Ideation and Depression (노인자살예방을 위한 통합적 위기개입모델 다층효과 연구: 자살생각·우울을 중심으로)

  • Kim, Eun Joo;Yook, Sung Pil
    • 한국노년학
    • /
    • v.37 no.1
    • /
    • pp.173-200
    • /
    • 2017
  • This study is designed to verify the actual effect on the prevention of the elderly suicide of the integrated crisis intervention service which has been widely provided across all local communities in Gyeonggi-province focusing on the integrated crisis intervention model developed for the prevention of elderly suicide. The integrated crisis intervention model for the local communities and its manual were developed for the prevention of elderly suicide by integrating the crisis intervention theory which contains local community's integrated system approach and the stress vulnerability theory. For the analysis of the effect, the geriatric depression and suicidal ideation scale was adopted and the data was collected as follows; The data was collected from 258 people in the first preliminary test. Then, it was collected from the secondary test of 184 people after the integrated crisis intervention service was performed for 6 months. The third collection of data was made from 124 people after 2 or 3 years later using the backward tracing method. As for the analysis, the researcher used the R Statistics computing to conduct the test equating, and the vertical scaling between measuring points. Then, the researcher conducted descriptive statistics analysis and univariate analysis of variance, and performed multi-level modeling analysis using Bayesian estimation. As a result of the study, it was found out that the integrated crisis intervention model which has been developed for the elderly suicide prevention has a statistically significant effect on the reduction of elderly suicide in terms of elderly depression and suicide ideation in the follow-up measurement after the implementation of crisis intervention rather than in the first preliminary scores. The integrated crisis intervention model for the prevention of elderly suicide was found to be effective to the extent of 0.56 for the reduction of depression and 0.39 for the reduction of suicidal ideation. However, it was found out in the backward tracing test conducted 2-3 years after the first crisis intervention that the improved values returned to its original state, thus showing that the effect of the intervention is not maintained for long. Multilevel analysis was conducted to find out the factors such as the service type(professional counseling, medication, peer counseling), characteristics of the client (sex, age), the characteristics of the counselor(age, career, major) and the interaction between the characteristics of the counselor and intervention which affect depression and suicidal ideation. It was found that only medication can significantly reduce suicidal ideation and that if the counselor's major is counseling, it significantly further reduces suicidal ideation by interacting with professional counseling. Furthermore, as the characteristics of the suicide prevention experts are found to regulate the intervention effect on elderly suicide prevention in applying integrated crisis intervention model, the primary consideration should be given to the counseling ability of these experts.

Changes in fish species composition after fishway improvement in Songrim weir, Yeongok stream (연곡천 송림보에서 어도의 개선에 따른 어류 종 조성 변화)

  • Yun, Young-Jin;Kim, Ji Yoon;Kim, Hye-Jin;Bae, Dae-Yeol;Park, Gu Seong;Nam, Chang Dong;Lim, Kyung Hun;Lee, Moon-Yong;Lee, Seong-Yong;Moon, Kyeong-Do;Lee, Eui-Haeng;An, Kwang-Guk
    • Korean Journal of Environmental Biology
    • /
    • v.39 no.2
    • /
    • pp.195-206
    • /
    • 2021
  • In 2020, South Korea initiated research and development of a longitudinal connectivity evaluation between upstream and downstream based on stream ecosystem health. This study analyzed the migration of upstream and downstream migratory fish species, fish distribution characteristics, trophic guilds, tolerance guilds, and species composition changes from 2015 to 2020 at Songrim weir in Yeongok stream, where the cross-structure of an ice harbor-type fishway for fish movement was recently improved. A total of 5,136 fish, including 36 species, were collected and three major migratory fishes were identified, namely, Tribolodon hakonensis, Plecoglossus altivelis altivelis, and Oncorhynchus keta. According to the comparative analysis before (Pre-I) and after (Post-I) improvement of the fishway, the relative abundance of primary freshwater fish increased in the upstream section, while the number of migratory fishes decreased. The fish species that used the fishway in the Songrim weir were Tribolodon hakonensis (58.4%) and Plecoglossus altivelis altivelis(11.8%). According to the Wilcoxon Signed-Rank Test migratory fish showed a statistically significant difference (p<0.05) in the upstream and downstream, showing a biological improvement effect of the crossstructure. On the other hand, the annual change of migratory fish based on the MannKendall trend test did not significantly increase or decrease (p>0.05). Therefore, in the fish passage improvement project, it is necessary not only for physical, hydrological, and structural tests, but also for pre- and post-biological tests on the use and improvement effect of fishway.

Preservation of the Posterior Ligaments for Preventing Postoperative Spinal Instability in Posterior Decompression of Lumbar Spinal Stenosis: Comparative Study between Port-Hole Decompression and Subtotal Laminectomy (요추부 척추관 협착증의 후방 감압술에서 후방 인대의 보존 여부와 술 후 척추 불안정성과의 연관성: 포트홀(Port-Hole) 감압술과 후궁 아전절제술 간 비교 연구)

  • Jung, Yu-Hun;Na, Hwa-Yeop;Choe, Saehun;Kim, Jin;Lee, Joon-Ha
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.71-77
    • /
    • 2020
  • Purpose: To determine if sparing the interspinous and supraspinous ligaments during posterior decompression for lumbar spinal stenosis is significant in preventing postoperative spinal instability. Materials and Methods: A total of 83 patients who underwent posterior decompression for lumbar spinal stenosis between March 2014 and March 2017 with a minimum one-year follow-up period, were studied retrospectively. The subjects were divided into two groups according to the type of surgery. Fifty-six patients who underwent posterior decompression by the port-hole technique were grouped as A, while 27 patients who underwent posterior decompression by a subtotal laminectomy grouped as B. To evaluate the clinical results, the Oswestry disability index (ODI), visual analogue scale (VAS) for both back pain (VAS-B) and radiating pain (VAS-R), and the walking distance of neurogenic intermittent claudication (NIC) were checked pre- and postoperatively, while simple radiographs of the lateral and flexion-extension view in the standing position were taken preoperatively and then every six months after to measure anteroposterior slippage (slip percentage), the difference in anteroposterior slippage between flexion and extension (dynamic slip percentage), angular displacement, and the difference in angular displacement between flexion and extension (dynamic angular displacement) to evaluate the radiological results. Results: The ODI (from 28.1 to 12.8 in group A, from 27.3 to 12.3 in group B), VAS-B (from 7.0 to 2.6 in group A, from 7.7 to 3.2 in group B), VAS-R (from 8.5 to 2.8 in group A, from 8.7 to 2.9 in group B), and walking distance of NIC (from 118.4 m to 1,496.2 m in group A, from 127.6 m to 1,481.6 m in group B) were improved in both groups. On the other hand, while the other radiologic results showed no differences, the dynamic angular displacement between both groups showed a significant difference postoperatively (group A from 6.2° to 6.7°, group B from 6.5° to 8.4°, p-value=0.019). Conclusion: Removal of the posterior ligaments, including the interspinous and supraspinous ligaments, during posterior decompression of lumbar spinal stenosis can cause a postoperative increase in dynamic angular displacement, which can be prevented by the port-hole technique, which spares these posterior ligaments.

Characteristics and Quality Control of Precipitable Water Vapor Measured by G-band (183 GHz) Water Vapor Radiometer (G-band (183 GHz) 수증기 라디오미터의 가강수량 특성과 품질 관리)

  • Kim, Min-Seong;Koo, Tae-Young;Kim, Ji-Hyoung;Jung, Sueng-Pil;Kim, Bu-Yo;Kwon, Byung Hyuk;Lee, Kwangjae;Kang, Myeonghun;Yang, Jiwhi;Lee, ChulKyu
    • Journal of the Korean earth science society
    • /
    • v.43 no.2
    • /
    • pp.239-252
    • /
    • 2022
  • Quality control methods for the first G-band vapor radiometer (GVR) mounted on a weather aircraft in Korea were developed using the GVR Precipitable Water Vapor (PWV). The aircraft attitude information (degree of pitch and roll) was applied to quality control to select the shortest vertical path of the GVR beam. In addition, quality control was applied to remove a GVR PWV ≥20 mm. It was found that the difference between the warm load average power and sky load average power converged to near 0 when the GVR PWV increased to 20 mm or higher. This could be due to the high brightness temperature of the substratus and mesoclouds, which was confirmed by the Communication, Ocean and Meteorological Satellite (COMS) data (cloud type, cloud top height, and cloud amount), cloud combination probe (CCP), and precipitation imaging probe (PIP). The GVR PWV before and after the application of quality control on a cloudy day was quantitatively compared with that of a local data assimilation and prediction system (LDAPS). The Root Mean Square Difference (RMSD) decreased from 2.9 to 1.8 mm and the RMSD with Korea Local Analysis and Precipitation System (KLAPS) decreased from 5.4 to 4.3 mm, showing improved accuracy. In addition, the quality control effectiveness of GVR PWV suggested in this study was verified through comparison with the COMS PWV by using the GVR PWV applied with quality control and the dropsonde PWV.