• Title/Summary/Keyword: impression technique

Search Result 176, Processing Time 0.03 seconds

EFFECT OF IMPRESS10N TECHNIQUE ON THE ACCURACY OF MASTER CAST FOR IMPLANT PROSTHESIS (인상채득법이 임플랜트 주모형의 정확성에 미치는 영향)

  • Kim Young-Oh;Yang Hong-So;Vang Mong-Sook;Park Sang-Won;Park Ha-Ok;Lee Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.63-72
    • /
    • 2006
  • Purpose: The purpose of this study was to compare the accuracy of master cast fabricated by using different impression methods at the different impression levels. Material and Method: The master model used in this study was resin block having low implant analogs. Impression method studied were 1) direct method on future level (Group FIX-D), 2) Indirect method on fixture level(Group FIX-I), 3) Modified indirect method on fixture level(Group FD(-M), 4) Direct method on abutment level(Group AB-D) and 5) Indirect method on abutment level(Group AB-I). Each of the five groups took 10 impressions. Fifty impressions were made for master cast by using Impregum $F^(R)$ impression material loaded on individual tray. Three dimensional measuring microscope was used to measure the inter-implant distance. Error rate of each inter-implant distance were calculated and evaluated. Results: The results were as follows. 1. Group FIX exhibited higher accuracy than group AB. 2 In group FIX, modified indirect method showed the highest accuracy, while indirect method showed the lowest accuracy. In group Ab, indirect method showed the higher accuracy than direct method. 3. Group FIX showed larger horizontal error than group AB. But, group AB showed the larger vertical error than group FIX. 4. Group Fix-M showed smallest vertical and horizontal error.

Comparison of the accuracy of implant digital impression coping (임플란트 디지털 인상용 코핑의 정확성 비교)

  • Ahn, Gyo-Zin;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.1
    • /
    • pp.29-40
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the accuracy of impression taking method using the encoded healing abutment, scan body and pick-up impression coping with different implant angulations. Materials and Methods: Master model was fabricated by 3D printer and three implants were placed into the model with 0°, 10° and 20° mesial angulation. The abutments were secured to each implants and master model was scanned to make a reference model. Group P model was fabricated using pick-up impression copings and model was scanned after securing the abutments. Encoded healing abutment (Group E) and scan body (Group S) were secured on the master model and digital impression was taken using intraoral scanner 15 times each. Each STL files of test groups were superimposed with reference model using best fit alignment and root mean square (RMS) value was analyzed. Results: The RMS values were lowest in Group P, followed by Group S and Group E. Group P showed significant difference with Group S and E (P < 0.05) while there was no significant difference between Group S and E. Correlation between implant angulation and RMS value was significant in Group E (P < 0.05). Conclusion: The pick-up impression coping method showed higher accuracy and there was no significant difference in accuracy between the healing abutment and the scan body. The clinical use of the encoded healing abutment is possible, but it should be used with caution in the case of angulated implant.

Role of span length in the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques

  • Zhou, Ying;Li, Yong;Ma, Xiao;Huang, Yiqing;Wang, Jiawei
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.2
    • /
    • pp.124-129
    • /
    • 2017
  • PURPOSE. This study evaluated the effect of span length on the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques. MATERIALS AND METHODS. Models with two solid abutment analogs at different inter-abutment distances were digitized using a laboratory scanner. Frameworks of two-, three-, and four-unit fixed prostheses were designed by a computer. Six dots with a diameter of 0.2 mm were preset on the surface of each framework. A total of 54 implant-supported cobalt chromium frameworks were fabricated by milling, selective laser melting (SLM), and cast techniques. The frameworks were scanned and exported as Stereolithography files. Distances between two dots in X, Y, and Z coordinates were measured in both the designed and fabricated frameworks. Marginal gaps between the framework and the abutments were also evaluated by impression replica method. RESULTS. In terms of distance measurement, significant differences were found between three- and four-unit frameworks, as well as between two- and four-unit frameworks prepared by milling technique (P<.05). Significant differences were also noted between two- and three-unit frameworks, as well as between two- and four-unit frameworks prepared by cast technique (P<.05). The milling technique presented smaller differences than the SLM technique, and the SLM technique showed smaller differences than the cast technique at any unit prostheses (P<.05). Evaluation with the impression replica method indicated significant differences among the span lengths for any fabrication method (P<.05), as well as among the fabrication methods at any unit prostheses (P<.05). CONCLUSION. The adaptation of implant-supported cobalt chromium frameworks was affected by the span length and fabrication method.

Use of intraoperative impression smear cytology to guide successful treatment of a large renal cyst in a dog: a case report

  • Balda, Ignacio Otero;Vagias, Michail;Cassidy, Joseph;O'Brien, Peter J.;Mullins, Ronan A.
    • Journal of Veterinary Science
    • /
    • v.23 no.2
    • /
    • pp.34.1-34.7
    • /
    • 2022
  • A 13-yr-old Shih tzu was referred for surgical management of right-sided cranial abdominal mass, which corresponded to large, cavitated renal mass on ultrasonography, and was suspected to represent neoplasia. Intraoperative impression smear cytology (ISC) of the renal mass wall was consistent with benign renal cyst (RC), without evidence of neoplasia or infection. Deroofing and omentalisation were performed and histopathology was consistent with benign RC. Chronic kidney disease was diagnosed 4 mon postoperatively, however, the dog was asymptomatic, without cyst reoccurrence. Intraoperative ISC is an expedient and inexpensive diagnostic technique that can guide most appropriate treatment in dogs with large RCs.

The neutral zone approach for restoration of patient with severe mandibular ridge resorption: A case report (하악 치조제가 심하게 흡수된 환자에서 중립대 인상을 통한 총의치 수복 증례)

  • Cheol Namgung
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.32 no.1
    • /
    • pp.8-15
    • /
    • 2023
  • In case with severely atrophied mandibular ridges, it may be difficult to achieve adequate retention and stability of dentures through the normal functional impression process of complete dentures. In these patients, an approach using the neutral zone raising technique may be an effective alternative. The neutral zone is defined as the area where the pressure of the tongue towards the outside of the mouth and the pressure of the cheek and lips towards the inside are balanced during the normal oral function of the muscular-nervous system. Complete dentures made through neutral zone impression not only improve retention and stability, but also provide adequate tongue space in the posterior teeth area. Additionally, food residues are reduced in the area around artificial teeth, and aesthetics are improved through appropriate facial support.

Computer-assisted Virtual Surgery and Splint Fabrication for Paediatric Mandible Fracture

  • Lee, Jung-woo
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.2
    • /
    • pp.87-89
    • /
    • 2015
  • Closed reduction using acrylic splints with circummandibular fixation has been known to be useful techniques in pediatric mandibular fractures. However, this technique has some shortcomings, including needs for impression taking or additional laboratory process, which can increase the exposure time of general anesthesia or make an additional sedation visit. Recently, the advancement of computer-aided maxillofacial surgery offers to clinicians to expansion of its application. This case report represents a technique of computer-assisted virtual reconstruction and computer-aided designed splint fabrication in a 2-year-old boy with mandibular body fracture.

A Study on Aesthetic Impression of Cinemagraphs Expressed in Advertising Media (광고매체에서 표현된 시네마그래프의 심미성 연구)

  • Kim, YoungIl;Kim, Hyeon-seok;Kim, Cheeyong
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.7
    • /
    • pp.1129-1135
    • /
    • 2017
  • Due to the development of the media, the digital image is gradually developed, giving some motion to the still image called Cinemagraphs, thereby enhancing the visual perceptional ventilation. In today's advertising media, visual stimuli are transmitted through Cinemagraphs. Demonstrate what is conveyed by aesthetics through case studies and experimental studies. In addition, through Cinemagraphs, the possibility of aesthetic technique is confirmed, and the features of Cinemagraphs will become a new trend in the field of design studying digital images. As IT technology becomes increasingly sophisticated and easy to make, it is expressed as a cultural symbolic pleasure of the masses. The value of future research will be significant.

Various Genioplasty techniques and case presentations (턱끝 성형술의 다양한 절골술식과 임상증례)

  • Choi, Jin Young
    • The Journal of the Korean dental association
    • /
    • v.58 no.2
    • /
    • pp.94-102
    • /
    • 2020
  • The form and location of chin is very important factor which determine the facial impression. Genioplasty is getting popular in order to improve the facial impression as facial beauty is considered as improvable factor. Through the geniplasty, chin can be moved to wanted location 3 dimensionally Genioplasty is relative simple but precise diagnosis and accurate surgical technique is very important for accurate and satisfying results. The form and shape of chin itself can be analysized and also must be evalulated in relation to the nose and lip and face. Author introduces the analysis of the chin, various surgical techniques of genioplasty and presents some cases.

  • PDF

Fabrication of complete denture using Centric tray and closed mouth technique for edentulous patient (과도한 치조제 흡수를 보이는 무치악 환자에서 Centric tray와 폐구법 인상을 이용한 총의치 수복 증례)

  • Jung, Sua;Ma, Boyoung;Yang, Hongso;Park, Sangwon;Lim, Hyun-Pil;Yun, Kwidug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.120-125
    • /
    • 2018
  • Conventional denture impression techniques have limitations for edentulous patients with severe alveolar bone resorption and can cause problems from excessive border extension. Especially when a patient has movable tissue it is difficult to make accurate impression, thus might interrupt stable seating of complete denture. Fabrication of complete denture using closed mouth technique for edentulous patient with severe ridge resorption is thought to provide better stability and retention. In this case, an 86-year-old patient had both edentulous jaws with epulis fissuratum on maxillary anterior ridge and severe mandibular ridge resorption. Thus, tentative vertical dimension was determined by using Centric trayand individual tray attached with gothic arch tracer was fabricated. Complete denture was fabricated using closed mouth technique and the patient was satisfied with better stability and retention of the complete denture.

Complete denture rehabilitation of edentulous patient with severe alveolar bone resorption using mandibular suction denture with closed mouth technique: a clinical report (치조골 흡수가 심한 완전 무치악 환자에서 폐구인상법을 이용한 총의치 수복 증례)

  • Ko, Chang Woo;Min, Byungkwee;Yang, Hong-so;Lim, Hyun-Pil;Yun, Kwidug;Shin, Jin-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.56-62
    • /
    • 2018
  • When it comes to treat patient with loss of vestibule, conventional denture impression have limitation which can cause problems of excessive border extension. Suction denture with closed mouth technique which was introduced to solve this problem, forms negative pressure being sealed denture flanges by mobile mucosa when the patient swallows and chews. Also, it can decrease patient's visiting time by taking impression and gothic arch tracing at once. In this case, considering patient's chief complain which is a loose fit of present lower denture, suction dentures with closed mouth technique was planned.