EFFECT OF IMPRESS10N TECHNIQUE ON THE ACCURACY OF MASTER CAST FOR IMPLANT PROSTHESIS
![]() |
Kim Young-Oh
(Department of Prosthodontics, Graduate School, Chonnam National University)
Yang Hong-So (Department of Prosthodontics, Graduate School, Chonnam National University) Vang Mong-Sook (Department of Prosthodontics, Graduate School, Chonnam National University) Park Sang-Won (Department of Prosthodontics, Graduate School, Chonnam National University) Park Ha-Ok (Department of Prosthodontics, Graduate School, Chonnam National University) Lee Jai-Bong (Dept. of Prosthodontics, College of Dentistry, Seoul National University) |
1 | Branemark PI. Zarb GA. Albreksson T. Tissue-integrated prostheses. Quintessence publish Company 1990;233-240 |
2 | Barrett MG. de Rijk WG. Burgess JO. The accuracy of six impression techniques for osseointegrated implants. J Prosthodont 1993:2:75-82 DOI ScienceOn |
3 | Assif D. Fenton A, Zarb G. Schmitt A. Comparative accuracy of implant impression procedures. Int J Periodont Rest Dent 1992;12:113-121 |
4 | Rodney J, Johansens R, Harris W. Dimensional accuracy of two implant impression copings. J Dent Res 1991:70:385 |
5 | Misch CE. Density of bone : Effect on treatment plans, surgical approach, healing, and progressive loading. Int J Oral Maxillofac Implants 1995;10:303-311 |
6 | Henry PJ. An alternative method for the production of accurate casts and occlusal records in osseointegrated implant rehabilitation. J Prosthet Dent :1987:58:694-697 DOI ScienceOn |
7 | Wee AG. Comparison of impression materials for direct multi-implant impressions. J Prosthet Dent 2000: 83: 323-331 DOI ScienceOn |
8 | Phillips KM. Nicholls JI, Ma T. Rubenstein J. The accuracy of three implant impression technique: A three-dimensional onal analysis. Int J Oral Maxillofac Implant 1994:9:533-540 |
9 | Lorenxoni M. Pertl C. Penkner K. Polansky R. Sedaj B. Wegscheider WA. Comparison of the transfer precision of three different impression materials in combination with transfer caps for the Frialit-2 system. Journal of Oral Rehabilitation 2000:27:629-638 DOI ScienceOn |
10 | Misch CE. Contemporary implant dentistry, Mosby Year Book. Inc. St. Louis 1993 |
11 | Jemt T. In vivo measurements of precision fit involving implant-supported prostheses in the edentulous jaw. Int J Oral Maxillofac Implants 1996:11:151-8 |
12 | Liou AD. Nicholls JI. Yuodelils R. Brudvik JS. Accuracy of replacing three tapered transfer impression copings in two elastomeric impression material. Int J Periodont Rest Dent 1993:6:377-383 |
13 | Adell R, Lekhalm U, Radder B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981: 10:387-416 DOI |
14 | Clelland NL, Carr AB, Gilat A. Comparison of strains transferred to a bone simulant between as-cast and post-soldered implant frameworks for a five-implant-supported fixed prosthesis. J Prosthodont 1996; 5: 193-200 DOI ScienceOn |
15 | Sones AD. Complications with osseointegrated implants. J Prosthet Dent 1989;62: 581-585 DOI ScienceOn |
16 | Branemark PI. Zarb GA. Albrektsson T. Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry. Chicago. Quintessence Publ Co 1985;117-128 |
17 | Sellers GC. Direct assembly framework for osseointegrated implant prosthesis. J Prosthet Dent 1989; 62: 662-668 DOI ScienceOn |
18 | Carr AB. A comparison of impression techniques for a five implant mandibular model. Int J Oral Maxillofac Implants 1991 ;6:448-455 |
19 | Han ET. Kim YS. Kim CW. A comparative analysis of the accuracy of implant impression techniques by using strain gauge. J Korean Academy of Prosthodontics 1995;33:539 |
20 | Worthington P, Bolendef CL, Taylar TD. The Swedish system of osseo-integrated implants: problems and complications encountered during a 4-year trial period. Int J Oral Maxillofac Implants 1987; 77-84 |
21 | Tautin FS. Impression making for osseointegrated denture. J Prosthet Dent 1985 :54: 250-251 DOI ScienceOn |
22 | Carr AB. Master J. The accuracy of implant verification casts compared with casts produced from a rigid transfer coping technique. J Prosthet Dent 1996:5:248-52 |
23 | Craig RG. Restorative Dental Materials. St Louis. CV Mosby Co. 1989:293-346 |
24 | Burguete RL. Johns RB. King T. Patterson EA. Tightening characteristics for screwed joints in osseointegrated dental implants. J Prosthet Dent 1994;71:592-599 DOI ScienceOn |
25 | Rangert B. Jemt T. Jorneus L. Forces and movements on Branemark implants. Int J Oral Maxillofac Implants 1990:4:241-247 |
26 | Assif D. Marshak B, Schmidt A. Accuracy of implant impression techniques. Int J Oral Maxillofac Implants 1996: 11 :216-22 |
27 | Spector M. Donovan TE. Nicholls JI. An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 1990:63:444-7 DOI ScienceOn |
28 | Humphries RM. Yaman P. Bleom TJ. The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants 1990;5:331-336 |
29 | Zarb GA. Schmitt A. The longitudinal clinical effectiveness of osseo-integrated dental implants. The Tronto study. Part Ill: Problem and complications encountered. J Prosthet Dent 1990;64:185 |
![]() |