• Title/Summary/Keyword: impressed current

Search Result 88, Processing Time 0.027 seconds

The Performance of Cathodic Protection with ICCP

  • Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1286-1290
    • /
    • 2004
  • This paper describes the anti-corrosion system on underwater structures of ships. Metals and alloys have several positions in the series such as immunity, corrosion and passivity. The iron potential has to change from the corrosion position to the anodic protection or cathodic protection for preventing corrosion by providing corrosion protection system such as ICCP(Impressed Current Cathodic Protection). The purpose of ICCP system is to eliminate the rusting or corrosion, which occurs on metal immersed in water. The system includes a power supply unit, which consists of a transformer, a converter. a controller, etc. This paper presents the protection performance of ICCP under dynamic condition such as velocity. The variation of potential and current density with time and environment factors are also described Finally, the experimental results will be explained and analysed.

Influence on Lead Wire Method of Distributed ICCP Systems for Mitigation of DC Traction Interference (전철 간섭 대책용 분포형 외부전원시스템의 배관인출 방법에 따른 영향)

  • Lee, H.G.;Ha, Y.C.;Ha, T.H.;Bae, J.H.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.282-284
    • /
    • 2005
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the influence on lead wire method of distributed ICCP(impressed current cathodic protection) systems for mitigation of DC traction interference using the simulation software CatPro.

  • PDF

Influence on Parallel Pipelines of Distributed ICCP Systems for Mitigation of DC Traction Interference (전철 간섭 대책용 분포형 외부전원시스템이 병행하는 배관에 미치는 영향)

  • Lee, H.G.;Ha, Y.C.;Ha, T.H.;Bae, J.H.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.285-287
    • /
    • 2005
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the influence on parallel pipelines of distributed ICCP(impressed current cathodic protection) systems for mitigation of DC traction interference using the simulation software CatPro.

  • PDF

Anode Location of Distributed ICCP Systems for Mitigation of DC Traction Interference on Buried Pipelines (전철 간섭 대책용 분포형 외부전원시스템의 양극위치)

  • Lee, H.G.;Ha, T.H.;Ha, Y.C.;Bae, J.H.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1660-1662
    • /
    • 2005
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the anode location of distributed impressed current cathodic protection systems for the mitigation of DC traction interference on buried pipelines using the simulation software CatPro. We can get a fix on the anode location.

  • PDF

Evaluation of Steel Corrosion and Flexural Strength Coated with Cementitious Repair Material (시멘트계 보수재료로 코팅된 강재의 부식 및 휨강성 평가)

  • Yoon, Yong-Sik;Kim, Tae-Sang;Kim, Ho-Ryong;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.3
    • /
    • pp.243-249
    • /
    • 2016
  • The present work is for an evaluation of resistance to corrosion in steel coated with cementitious repair material, so that 3 cases of steel plate(Normal, Welding, Welding & coating case) are subjected to ICM(Impressed Current Method) for acceleration of corrosion for 7days. Tested and estimated corrosion ratio through Faraday's Law are compared, and the related flexural strength are evaluated. In Normal and Welding cases, similar level of corrosion ratio(70%) is evaluated, however only 17% level of corrosion ratio is evaluated in the Welding & coating case, which indicates that cementitious repair material is effective to anti-corrosion due to a block of chloride penetration. The flexural test results are consistent with those in accelerated corrosion test, which shows a significant flexural strength in Welding & coating case by 3.4times greater than the others. The cementitious material repair coating is evaluated to be effective to anti-corrosion in welding of steel plate.

Experimental Study on Artificial Crack Healing for Concrete Using Electrochemical Deposition Method (전기화학적 전착기법을 활용한 콘크리트의 인공 균열치유에 관한 실험적 연구)

  • Lee, Chang-Hong;Song, Ha-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.4
    • /
    • pp.409-417
    • /
    • 2009
  • In this study, autogenous crack healing and artificial crack healing using electrochemical electro deposition method were conducted to compare in the aspects of corrosion monitoring. Furthermore, the analysis of impressed voltage characteristics, galvanic current and linear polarization resistance comparison, and photo image processing technique were performed for quantitative comparisons of healing ratio. As a result, it was found that, in view of impressed voltage of artificial crack healing, the measured voltage was increased as time goes by. From the galvanic test results of artificial crack healing, the current vs. potential distribution value were formed widely in comparison with autogenous crack healing. In this point, it was shown that artificial crack healing has more eleatic resistance capacity than autogenous crack healing technique. Finally, it was found that artificial crack healing was 1.63 times higher than autogenous healing in view of crack healing ratio.

Evaluation of Corrosion Resistance with Grout Type and Tendon (그라우트 품질을 고려한 텐던의 부식저항성 평가)

  • Ryu, Hwa-Sung;An, Ki-Hong;Koh, Kyung-Taek;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.76-82
    • /
    • 2018
  • Grout in duct is very effective protection from tendon corrosion in PSC(Prestressed Concrete) structure. In the work, durability and mechanical tests are performed for two types of grout which are conventionally used one and the improved grout with reduced w/c (water to cement) ratio and silica fume. Tendon system with 1000mm height is prepared and various tests including strength, flow, absorption, and bleeding ratio are conducted. ICM(Impressed Current Method) is adopted for corrosion acceleration in tendon with 12.7mm diameter inside grout. For 2 and 4 days, corrosion acceleration is performed for 2 different type of grout and corrosion amount is investigated. The improved grout shows higher compressive strength by 10 MPa and lower absorption ratio by 50% than the conventional one. It also provides an excellent corrosion reduction to 39.8 %~48.2 % for 2~4 days of acceleration period.

Anti-Corrosion Property of Geopolymer Evaluated by an Impressed Current Cathodic Protection Method, Exposed to Marine Environment (염해환경에서 외부전원법에 의한 지오폴리머 시험체 보강철근의 방식특성 평가)

  • Lee, Hae-Seung;Cho, Ggu-Hwan;Park, Dong-Cheon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.5
    • /
    • pp.397-405
    • /
    • 2014
  • There are many literatures reporting that the service life of re-bars in concrete structures is reduced in the oceanic environment due to chloride attack. To solve this problem, this study used geo-polymer as a mix material for concrete to increase its resistance to salt damage, and the external voltage method, one of the electric methods, is was applied to evaluate the likelihood of re-bars in the oceanic structure being exposed to the extreme salt environment. The items evaluated include the natural potential of re-bars and the corrosion rate. The results of the tests showed that in all of the salt environmental conditions (submerged zone, tidal zone, and crack), the tested materials were remarkably effective compared with ordinary concrete. The corrosion protective property was found not only in the evaluation of the natural potential but also in the evaluation of the corrosion rate, suggesting that the external voltage method can be used stably for geo-polymer RC structures in an extreme salt environment.

Evaluation of Load Capacity Reduction in RC Beam with Corroded FRP Hybrid Bar and Steel (철근부식을 고려한 FRP Hybrid Bar 및 일반 철근을 가진 RC 보의 내력저하 평가)

  • Oh, Kyung-Suk;Moon, Jin-Man;Park, Ki-Tae;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.2
    • /
    • pp.10-17
    • /
    • 2016
  • Steel corrosion is a very significant problem both to durability and structural safety since reinforcement has to support loads in tensile region in RC(Reinforced Concrete) member. In the paper, newly invented FRP Hybrid Bar and normal steel are embedded in RC beam member, and ICM (Impressed Current Method) is adopted for corrosion acceleration. Utilizing the previous theory of Faraday's Law, corrosion amount is calculated and flexural tests are performed for RC beam with FRP Hybrid Bar and steel, respectively. Corrosion amount level of 4.9~7.8% is measured in normal RC member and the related reduction of flexural capacity is measured to be -25.4~-50.8%, however there are no significant reduction of flexural capacity and corrosion initiation in RC samples with FRP Hybrid Bar due to high resistance of epoxy-coated steel to corrosion initiation. In the accelerated corrosion test, excellent performance of anti-corrosion and bonding with concrete are evaluated but durability evaluation through long-term submerged test is required for actual utilization.

A Study on the Corrosion Control and Protection of 154kV Underground Pipe-type Oil Filled (POF) Cable (154kV 지중 POF 케이블의 부식방지(腐蝕防止)에 관한 연구(硏究))

  • Lee, D.I.;Kim, J.B.;Jeong, D.W.;Kim, D.K.;Lee, J.B.;Jeong, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.161-165
    • /
    • 1990
  • KEPCO has experienced eight oil leakage failures due to POF cable corrosion in the 154KV underground POF cable transmission line since the line was operated in 1976. Experimentally, We have verified that the cause of the failure is electrolytic corrosion of the cable owing to subway leakage current. For the countermeasure, We adopted the total Cathodic Protection System by the use of Victim Anode, Forced Drainage Method and Impressed Current Method with polarization cell.

  • PDF