• Title/Summary/Keyword: implantation rate

Search Result 388, Processing Time 0.034 seconds

Studies on Culture and Transfer of Mouse Embryos Biseeted at Various Cell Stages (생쥐배의 발생단계별 미세분할, 배양 및 이식 관한 연구)

  • 강대진;박희성;이효종;박충생
    • Journal of Embryo Transfer
    • /
    • v.4 no.1
    • /
    • pp.28-34
    • /
    • 1989
  • These experiments were carried out to determine the effect of cell stage in embryo bisection on the sub-Sequent in vitro and in vivo development in mouse. The embryos of ICR mouse were microsurgicaily bisected at 2-cell, 4-cell, 8-cell, morula and blastocyst stage using a microsurgical blade attached a micromanipulator. These demi-embryos without zona pellucida were cultured up to blastocyst stage and transferred to pseudopregnant mice, and the development of these demi-embryos was compared with the results of intact embryos of the corresponding cell stage. The successful rate of mouse embryo bisection at 4-cell stage (59.0%) was significantly (p <0.05) lower than those at 8-cell (75.6%), 2ce11 (80.7%) or morula stage (84.8%), and highest at blastocyst stage (95.7%). When the bisected embryos without any damage from microsurgery were cultured in vitro up to blastocyst,the in vitro de'velopment of demi-embroys bisected at morula to blastocyst was 91.6 to 95.3%, which was similar to the culture result of intact embryos of corresponding stage. However, the in vitro development of demi-em-bryos bisected at 2- to 8-cell stage was signiflcantiy (p <0.05) lower.The post-transfer implantation rate of demi-embryos developed in vitro to eu-blastocyst were 19.6 and 25.4% in demi-embryos bisected at morula and blastocyst stage,respectively and not significantly (P <0.05)different from the result of intact embryos of the same stage. However, the implantation rates of demi-embryos bisected at 2- or 8-cell stage were significantly (P <0.05) lower than the result from the intact embryos of the corresponding stage.

  • PDF

Factors affecting the ongoing pregnancy rate in women with repeated implantation failure undergoing an endometrial receptivity array

  • Hyun Kyoung Lee;Kyoung Yong Moon;Haerin Paik;Byung Chul Jee
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.50 no.4
    • /
    • pp.277-284
    • /
    • 2023
  • Objective: In this retrospective study, we analyzed factors influencing the ongoing pregnancy rate (PR) in women with repeated implantation failure (RIF) undergoing embryo transfer with endometrial receptivity array (ERA). Methods: Eighty-three consecutive personalized embryo transfers (pETs) with ERA, from 54 women with RIF, were selected from June 2020 to April 2022. Vitrified blastocyst transfer was timed based on ERA results. Results: The ongoing PR per pET was 33.7%. Using ERA, the endometrium was identified as pre-receptive in 26 cycles, early receptive in 25 cycles, receptive in 31 cycles, and late receptive in one cycle. With cycles categorized into three receptivity phases (pre-receptive, early receptive, or receptive), no significant differences were found in the clinical PR (27.3%, 55.6%, and 40%, respectively) or ongoing PR (9.1%, 55.6%, and 40%, respectively) after a single blastocyst transfer. Similarly, no significant differences were observed in the clinical PR or ongoing PR after the transfer of two or more blastocysts. Among women with ongoing pregnancy relative to those without, age at first pET was significantly lower (35 years vs. 39 years, p=0.001), while blastocyst score (23 vs. 18, p=0.012) and the proportion of blastocyst scores >18 (71.4% vs. 38.9%, p=0.005) were significantly higher. In multiple logistic regression analysis, the woman's age (odds ratio [OR], 0.814; 95% confidence interval [CI], 0.706 to 0.940; p=0.005) and blastocyst score >18 (OR, 3.052; 95% CI, 1.075 to 8.665; p=0.036) were identified as significant factors influencing ongoing pregnancy. Conclusion: In pET with ERA, ongoing pregnancy was closely associated with woman's age and blastocyst quality.

STABILITY CHANGES OF IMMEDIATELY LOADED AND DELAYED LOADED IMPLANTS IN EDENTULOUS MANDIBLE (하악 무치악에서 즉시하중과 지연하중간 임플랜트의 안정성 변화)

  • Jung, Hye-Eun;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra;Yi, Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.250-262
    • /
    • 2007
  • Statement of problem: It was reported high success rate of implant-supported fixed prostheses using with $5{\sim}6$ implants on anterior mandible. Recently, immediate loading protocol was focused to overcome disadvantages of classic 2-stage delayed loading protocol. Purpose: This clinical study was to evaluate stability changes with time of immediately loaded and delayed loaded implants in edentulous mandible and to compare stability changes with time according to implantation sites. Materials and methods: Five or six implants were placed on anterior mandible depending on the arch shape. The immediately loading group was consisted of 8 patients received their prostheses within $24{\sim}48$ hours after implantation. The delayed loading group was consisted of 8 patients received their definitive prostheses following classical prosthetic procedures after a healing period of 3 months. All patients were recalled every 6 months for check-up. The evaluations of radiographic examination, ISQ value measurement and recording of complication were done. To evaluate marginal bone level, intraoral periapical radiographs were taken with long cone paralleling technique. At every evaluation recall, all prostheses were removed and ISQ values were measured with OsstellTM on individual implants. Results: 1. None of implants was failed. All implants showed stable marginal bone levels and ISQ values. 2. Marginal bone level changes with time showed statistically significant difference between immediately loading group and delayed loading group (P<0.001). 3. ISQ value changes with time did not show statistically significant difference between immediately loading group and delayed loading group (P=0.079). ISQ value decreased with time in both groups, however, all implants showed stable ISQ value at 30 months-recall evaluation. 4. Marginal bone level changes with time did not show statistically significant differences among implantation sites (P=0.604). 5. ISQ value changes with time showed statistically significant differences among implantation sites (P=0.047). ISQ values of most posterior implants decreased with time comparing to other implants. Conclusion: Although the marginal bone level of the terminal abutment didn't different with the other implants, ISQ value of the terminal abutment was lower than that of the other implants. Therefore, further clinical evaluation would be needed in this point of view.

Effect of Heparin-binding Epidermal Growth Factor (HB-EGF) on Integrin $\alpha_{\nu}-\betaFe_3$ Expression in Preimplantation Mouse Embryos

  • Lim, Jung-Jin;Shin, Hyun-Sang;Lee, Ji-Won;Kang, Sue-Man;Lee, Sung-Eun;Kang, Han-Seung;Kim, Moon-Kyoo
    • Proceedings of the Korean Society of Embryo Transfer Conference
    • /
    • 2002.11a
    • /
    • pp.102-102
    • /
    • 2002
  • Heparin-bindin epidermal growth factor (HB-EGF) is one of the EGF family to be expressed at the time of implantation in the mouse uterus. Although HB-EGF has been shown to stimulate the development of embryo and uterus in the mouse, its correlation between cell adhesion molecules remains undefined. Integrin $\alpha$$_{ν}$$\beta$$_3$, one of the cell adhesion molecules, is an important mediator of cell-substratum and cell-cell adhesion in implantation. In the present studies, we investigated the effects of HB-EGF on the embryonic development, initiation of implantation and expression of integrin $\alpha$$_{ν}$$\beta$$_3$ in in vitro culture, blocking of HB-EGF, RT-PCR and immunofluores cence analysis. The results showed that HB-EGF significantly improved the developmental rate of hatched embryos (24.1%, p<0.01) and outgrowth embryos (42.5%, p<0.01). On the other hand, this growth factor showed no offset before the hatching embryonic stage. Analysis of RT-PCR showed that HB-EGF upregulated the expression level of integrina $\alpha$$_{ν}$$\beta$$_3$ subunit genes on the preimplantation embryo and outgrowth of blastocyst (120hr and 144hr after hCG injection). Immunofluorescence analysis showed that the integrin $\alpha$$_{ν}$$\beta$$_3$ subunits localized at the pericellular borders and cell-cell contact areas. Increase in fluorescence intensity was observed in the HB-EGF treated embryos. Intrauterine injection of an anti-HB-EGF antiserum at day 3 significantly decreased the number of implantation sites (14.4, p<0.01) and significantly increased the number of recovered embryos(6.4, p<0.05) at day 5. From these results, it imply that HB-EGF improve the embryo development and accelerated the expression of integrin $\alpha$$_{ν}$$\beta$$_3$ in the preimplantation mouse embryos.

  • PDF

Effects of Vth adjustment ion implantation on Switching Characteristics of MCT(MOS Controlled Thyristor) (문턱전압 조절 이온주입에 따른 MCT (MOS Controlled Thyristor)의 스위칭 특성 연구)

  • Park, Kun-Sik;Cho, Doohyung;Won, Jong-Il;Kwak, Changsub
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.69-76
    • /
    • 2016
  • Current driving capability of MCT (MOS Controlled Thyristor) is determined by turn-off capability of conducting current, that is off-FET performance of MCT. On the other hand, having a good turn-on characteristics, including high peak anode current ($I_{peak}$) and rate of change of current (di/dt), is essential for pulsed power system which is one of major application field of MCTs. To satisfy above two requirements, careful control of on/off-FET performance is required. However, triple diffusion and several oxidation processes change surface doping profile and make it hard to control threshold voltage ($V_{th}$) of on/off-FET. In this paper, we have demonstrated the effect of $V_{th}$ adjustment ion implantation on the performance of MCT. The fabricated MCTs (active area = $0.465mm^2$) show forward voltage drop ($V_F$) of 1.25 V at $100A/cm^2$ and Ipeak of 290 A and di/dt of $5.8kA/{\mu}s$ at $V_A=800V$. While these characteristics are unaltered by $V_{th}$ adjustment ion implantation, the turn-off gate voltage is reduced from -3.5 V to -1.6 V for conducting current of $100A/cm^2$ when the $V_{th}$ adjustment ion implantation is carried out. This demonstrates that the current driving capability is enhanced without degradation of forward conduction and turn-on switching characteristics.

Lobaplatin-TACE Combined with Radioactive 125I Seed Implantation for Treatment of Primary Hepatocellular Carcinoma

  • Peng, Sheng;Yang, Qiu-Xia;Zhang, Tao;Lu, Ming-Jian;Yang, Guang;Liu, Zhen-Yin;Zhang, Rong;Zhang, Fu-Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5155-5160
    • /
    • 2014
  • Aim: To investigate the efficacy and safety of lobaplatin-transcatheter arterial chemoembolization (TACE) combined with radioactive $^{125}I$ seed implantation in treatment of primary hepatocellular carcinoma (HCC). Methods: 75 patients with primary HCC were enrolled in the study, among them 43 receiving lobaplatin-TACE (TACE group) and 32 lobaplatin-TACE combined with $^{125}I$ seed implantation (TACE+$^{125}I$ group). After treatment, the local remission rates and postoperative complications of two groups were compared using the Pearson Chi-square test. Overall survival in the two groups was calculated using Kaplan-Meier survival curves and the differences were tested using Log-rank test. Results: There were 7 cases of complete response (CR), 13 of partial response (PR), 6 of stable disease (SD) and 17 of progressive disease (PD) in the TACE group, with 13 cases of CR, 9 of PR, 5 of SD and 5 of PD in the TACE+$^{125}I$ group. The disease control rates of TACE and TACE+$^{125}I$ group were 60.5% (26/43) and 84.4% (27/32), respectively, with a significant difference between them (P < 0.05). The survival rates at 6, 12 and 18 months in the TACE group were 100.0%, 81.8% and 50.0%, respectively, and those in TACE+$^{125}I$ group were 100.0%, 93.8% and 65.6%. The mean survival times in the TACE and TACE+$^{125}I$ groups were 19.5 and 22.9 months, respectively. There was a significant difference in the overall survival rate between two groups (P < 0.05). No serious complications were encountered in either group. Conclusion: Lobaplatin-TACE combined with $^{125}I$ seed implantation is favorable and safe for treatment of primary HCC.

HISTOMORPHOMETRIC STUDY OF DENTAL IMPLANTS WITH DOUBLE ACID-ETCHED AND ANODIC OXIDIZED SURFACE IN THE RABBIT TIBIA (토끼 경골에서 치과용 임프란트의 이중 산부식 및 양극 산화 표면처리에 따른 조직계측학적 연구)

  • Han, Ye-Sook;Kim, Il-Kyu;Chang, Keum-Soo;Park, Tae-Hwan;Jeon, Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.5
    • /
    • pp.434-444
    • /
    • 2006
  • This study was performed to evaluate the effects of three different implant surface treatments to the bone formation during osseous healing period under unloading conditions. Machined, double-acid etched and anodic oxidized implants were inserted into tibia of 3.0 - 3.5 kg NZ white male rabbits and 2 animals of each group were sacrificed at 2, 4 and 8 weeks. The specimens containing implant was dehydrated and embedded into hard methylmethacrylate plastic. After grinding to $50{\mu}m$, the specimens were stained with Villanueva bone stain. From each specimen, histomorphometric evaluation and the bone implant contact rate were analysed with optical microscope. The results were as follows; 1. In the scanning electronic microscopic examination, machined surface implant had several shallow and paralleled scratches on plain surface, double acid-etched implant had lots of minute wrinkles, rough valley and also irregularly located craters that looked like waves, anodic oxidized surface implant had porosity that minute holes were wholly distributed on the surface. 2. After 2 weeks of implantation, the percentages of bone-to-implant contact in the machined implant, double acid-etched implant and anodic oxidized implant were 26.85%, 62.64% and 59.82%, after 4 weeks of implantation they were 64.29%, 77.85% and 75.23%, and after 8 weeks they were 82.66%, 85.34% and 86.39%. 3. After 2 weeks of implantation, the percentages of bone area between threads in the machined implant, double acid-etched implant and anodic oxidized implant were 21.55%, 42.81%, and 40.33%, after 4 weeks of implantation they were 49.32%, 62.60% and 75.56%, and after 8 weeks they were 71.62%, 87.73% and 83.94%. In summary, percentages of implant surface contacted to bone trabeculae and bone formation area inside threads in double acid-etched implants and anodic oxidized implants were greater than machined implants in early healing stage. These results suggest that double acid-etched and anodic oxidized surface implants could reduce the healing period for osseointegration and may enable to do early function.

Early Outcomes of Sutureless Aortic Valves

  • Hanedan, Muhammet Onur;Mataraci, Ilker;Yuruk, Mehmet Ali;Ozer, Tanil;Sayar, Ufuk;Arslan, Ali Kemal;Ziyrek, Ugur;Yucel, Murat
    • Journal of Chest Surgery
    • /
    • v.49 no.3
    • /
    • pp.165-170
    • /
    • 2016
  • Background: In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods: Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. Results: The mean age of the patients was $71.15{\pm}8.60years$. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was $56.9{\pm}9.93$. The CPB time was $96.51{\pm}41.27minutes$ and the cross-clamping time was $60.85{\pm}27.08minutes$. The intubation time was $8.95{\pm}4.19hours$, and the intensive care unit and hospital stays were $2.89{\pm}1.42days$ and $7.86{\pm}1.42days$, respectively. The mean quantity of drainage from chest tubes was $407.69{\pm}149.28mL$. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was $687.24{\pm}24.76days$. The one-year survival rate was over 90%. Conclusion: In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.

AUTOTRANSPLANTATION OF THE MISSING TOOTH : THE REPORT OF CASES (결손치에서의 자가치아이식의 치험례)

  • Park, Jeong-Hoon;Kim, Woo-Taek;Min, Byeong-Jin;Lee, Won-Hak;Lee, Jeong-Gu
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.6
    • /
    • pp.480-483
    • /
    • 2002
  • Treatments for restoring the function and esthetics of missing teeth include fixed bridge, partial denture, orthodontic movement, implantation and autotransplantation. However, there is no absolute indications for each techniques. Due to undevelopment of root and root resorption after autotransplantation, the success rate of autotransplantation over the past decades have been low. Recently. with the study on biological principles of the healing of periodontal ligament, the success rate of autotransplantation began to improve. We report the cases of successful autotransplantation which resulted in ideal healing of periodontal ligament, gingiva and alveolar bone.

An Implementation of Embedded Linux System for Embossed Digit Recognition using CNN based Deep Learning (CNN 기반 딥러닝을 이용한 임베디드 리눅스 양각 문자 인식 시스템 구현)

  • Yu, Yeon-Seung;Kim, Cheong Ghil;Hong, Chung-Pyo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.2
    • /
    • pp.100-104
    • /
    • 2020
  • Over the past several years, deep learning has been widely used for feature extraction in image and video for various applications such as object classification and facial recognition. This paper introduces an implantation of embedded Linux system for embossed digits recognition using CNN based deep learning methods. For this purpose, we implemented a coin recognition system based on deep learning with the Keras open source library on Raspberry PI. The performance evaluation has been made with the success rate of coin classification using the images captured with ultra-wide angle camera on Raspberry PI. The simulation result shows 98% of the success rate on average.