• Title/Summary/Keyword: implant structure

Search Result 256, Processing Time 0.026 seconds

Proposition of a New Implantable Acoustic Sensor Based on Technology Evaluation of Fully Implantable Hearing Aids (완전 이식형 보청기 기술 평가 기반의 새로운 이식형 음향센서 제안)

  • Cho, Jin-Ho;Woo, Seong Tak;Lim, Hyung-Gyu;Jung, Eui Sung;Lee, Jyung Hyun;Lee, Seung-Ha;Seong, Ki Woong
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.178-184
    • /
    • 2014
  • Key components of implantable hearing aids are consist of an acoustic sensor that collect external sound by suppressing the body noise, a signal processor module for compensation algorithm of hearing loss, and a output transducer which has tiny size but have high efficiency, respectively. In the partial implantable hearing aids, technologies of transducer and signal processor are so matured that can be applied not too much difficulty. However, due to the difficulties in implantable acoustic sensor technology, such as minimization of masticatory sound and damage of sensor's membrane from external impact, practical use of fully implantable hearing aids have not successful so far. In this paper, we have proposed a novel implantable acoustic sensor which has trans-tympanic structure, and is verified that the proposed method can be very useful for fully implantable hearing aids by cadaveric experiments.

Relationship between Interdental Papilla Existence & Distance from Interdental Alveolar Crest to Contact Point in the Posterior Dentition of Korean adults (한국인 구치열에서 치간유두 존재와 치아접촉점과 치간골 거리와의 관계)

  • Kim, Hyun-Chul;Jeon, Yong-Seon;Chang, Moon-Taek;Kim, Hyung-Seop;Park, Jung-Mi
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.3
    • /
    • pp.625-631
    • /
    • 2001
  • The anatomic structure around interproximal area plays an important role not only in the natural teeth, but also in the implant. The loss of papilla can lead to cosmetic deformity, phonetic problem, food impaction on the anterior dentition, and masticatory problem, food impaction and proximal caries on the posterior dentition. The purpose of this study was to evaluate the relationship between interdental papilla existence and distance from contact point to alveolar crest in Korean posteior dentition. 45 Korean adult patients(31males, 14 females) participated in this study. Measurements were carreid out total 126 interproximal areas, 18 first premolar, 31 second premolar, 40 first molar, and 37 second molar areas. Papilla index was recorded as suggested by Jemt. Distance between contact point and alveolar crest measrued by Florida $probe^{R}$, after flap elevation. Each distance was measured 10 times by every 0.1mm unit. The results showed that the mean Papilla index 1.37 and mean distance between contact point and alveolar crest was 7.44mm. The correlation between the Papilla index and distance was high negative correlation(Pearson correlation=-0.47), and it was statistically significant(P=0.000) When the distance between contact point and alveolar crest was 5mm, the loss of papilla was appeared almost in half cases. When the distance was 6mm, the papilla loss was present 95%, when 7mm, the papilla loss was 100%.

  • PDF

Use of 3D Printing Model for the Management of Fibrous Dysplasia: Preliminary Case Study

  • Choi, Jong-Woo;Jeong, Woo Shik
    • Journal of International Society for Simulation Surgery
    • /
    • v.3 no.1
    • /
    • pp.36-38
    • /
    • 2016
  • Fibrous dysplasia is a relatively rare disease but the management would be quite challenging. Because this is not a malignant tumor, the preservation of the facial contour and the various functions seems to be important in treatment planning. Until now the facial bone reconstruction with autogenous bone would be the standard. Although the autogenous bone would be the ideal one for facial bone reconstruction, donor site morbidity would be the inevitable problem in many cases. Meanwhile, various types of allogenic and alloplastic materials have been also used. However, facial bone reconstruction with many alloplastic material have produced no less complications including infection, exposure, and delayed wound healing. Because the 3D printing technique evolved so fast that 3D printed titanium implant were possible recently. The aim of this trial is to try to restore the original maxillary anatomy as possible using the 3D printing model, based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. And we molded Titanium mesh to reconstruct three-dimensional maxillary structure during the operation. This prefabricated Titanium-mesh implant was then inserted onto the defected maxilla and fixed. Three dimensional printing technique of titanium material based on the computer simulation turned out to be successful in this patient. Individualized approach for each patient could be an ideal way to restore the facial bone.

The Mechanical Properties and Biocompatibility of Functionally Graded Coatings(FGC) of Hydroxyapatite(HA) and Metallic Powders - Functionally Gradient Coatings of Thermal Spray in Air- (Hydroxyapatite (HA)와 금속 분말 경사 코팅의 기계적 특성 및 생체 적합성 - 대기 열용사 경사코팅 -)

  • Kim, Eun-Hye;Kim, Yu-Chan;Han, Seung-hee;Yang, Seok-Jo;Park, Jin-Woo;Seok, Hyun-Kwang
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.1
    • /
    • pp.13-20
    • /
    • 2009
  • This work presents functionally graded coatings (FGC) of hydroxyapatite (HA) and metallic powders on Ti-6Al-4V implants using plasma spray coating method. HA has been the most frequently used coating material due to its excellent compatibility with human bones. However, because of the abrupt changes in thermomechanical properties between HA and the metallic implant across an interface, and residual stress induced on cooling from coating temperture to room temperature, debonding at the interface occurs in use sometimes. In this work, FGC of HA and Ti or Ti-alloy powders is made to mitigate the abrupt property changes at the interface and the effect of FGC on residual stress release is investigated by evaluating the mechanical bond strength between the implant and the HA coating layers. Thermal annealing is done after coating in order to crystallize the HA coating layer which tends to have amorphous structure during thermal spray coating. The effects of types and compositional ratio of metallic powders in FGC and annealing conditions on the bond strength are also evaluated by strength tests and the microstructure analysis of coating layers and interfaces. Finally, biocompatibility of the coating layers are tested under ISO 10993-5.

A STUDY OF COMPARATIVE GROWTH DYNAMICS AND TOTAL PROTEINS BETWEEN GRANULATION TISSUE FIBROBLASTS AND NORMAL FIBROBLASTS (만성 염증시 치주 결체조직 세포 성장 및 총 단백질 변화에 관한 연구)

  • Lim, Jeong-Su;Oh, Kwi-Ok;Kim, Hyung-Sup
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.1
    • /
    • pp.135-143
    • /
    • 1993
  • The investigation was undertaken to determin the altered function and structure of granulation tissue fibroblasts. Human granulation-tissue fibroblasts were cultured from periodontal chronic inflammatory lesions (SBI index : above 3) and compared with healthy gingival connective tissues fibroblasts a control(SBI index : below 1). Granulation tissue fibroblasts proliferated with a slower growth rate and exhibited larger cell size than control cells. Total protein profile of granulation tissue fibroblasts was almost identical to that of control cells with some exception. These results support tha theory that granulation tissue fibroblasts represent a distinct phenotype of fibrotic cells.

  • PDF

Control of Defect Produced in a Retrograde Triple Well Using MeV Ion Implantation (MeV 이온주입에 의한 Retrograde Triple-well 형성시 발생하는 결합제어)

  • 정희석;고무순;김대영;류한권;노재상
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.17-20
    • /
    • 2000
  • This study is about a retrograde triple well employed in the Cell tr. of next DRAM and flash memory. triple well structure is formed deep n-well under the light p-well using MeV ion implantation. MeV P implanted deep n-well was observed to show greatly improved characteristics of electrical isolation and soft error. Junction leakage current, however, showed a critical behavior as a function of implantation and annealing conditions. {311} defects were observed to be responsible for the leakage current. {311} defects were generated near the R$\sub$p/ (projected range) region and grown upward to the surface during annealing. This is study on the defect behavior in device region as a function of implantation and annealing conditions.

  • PDF

Accessory mental foramen: A rare anatomical variation detected by cone-beam computed tomography

  • Torres, Marianna Guanaes Gomes;Valverde, Ludmila De Faro;Vidal, Manuela Torres Andion;Crusoe-Rebello, Ieda Margarida
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.61-65
    • /
    • 2015
  • The mental foramen is a bilateral opening in the vestibular portion of the mandible through which nerve endings, such as the mental nerve, emerge. In general, the mental foramen is located between the lower premolars. This region is a common area for the placement of dental implants. It is very important to identify anatomical variations in presurgical imaging exams since damage to neurovascular bundles may have a direct influence on treatment success. In the hemimandible, the mental foramen normally appears as a single structure, but there are some rare reports on the presence and number of anatomical variations; these variations may include accessory foramina. The present report describes the presence of accessory mental foramina in the right mandible, as detected by cone-beam computed tomography before dental implant placement.

Project Management based Analysis for the Enterprise 6 Sigma Success Factors (프로젝트 경영관점에서의 전사 6 시그마 성공요인 분석)

  • Mhun, Young-Soo;Bae, Suk-Joo
    • Journal of Applied Reliability
    • /
    • v.11 no.1
    • /
    • pp.59-81
    • /
    • 2011
  • Six Sigma has been disseminated into a variety of areas. It is believed that a stepwise understanding of Six Sigma's DMAIC is required for successes of unit projects. Meanwhile, infra-structure factors, such as leadership, organization, personnel management, educational system, etc., are also important to safely implant the Six Sigma into the whole enterprise and to thoroughly create the culture of innovation and enterprise. Careful analysis of those elements makes it possible to draw common connection between Project Management and the Six Sigma. This study drives the success elements for the successful adoption of the Six Sigma in the Korea Western Power Co., Ltd., of which management was evaluated as one of the tops based on the results of 2007 Management Innovation Assessment and arranges the similarity of like this factor and Enterprise Project Management. The results of this study are expected to provide a useful guideline for the adoption of the Six Sigma in whole company level.

Micro Tube Pump for an Implantable Drug Infusion Device (이식형 약물 주입 장치용 마이크로 튜브 펌프)

  • Bach, Du-Jin;Park, Jun-Woo;Lee, Duck-Hee;Lee, Chul-Han;Hong, So-Young;Jo, Yung-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.1
    • /
    • pp.40-45
    • /
    • 2008
  • This paper proposes a tube pump composed of small-sized cams and followers for an implantable intrathecal drug infusion device. Each followers is driven by a cam and liquid is discharged by a sequential reciprocal motion of the followers. The advantage of this structure is that it allows the pump to be clean and valveless. To design a small-sized, low power pump some analysis were performed to determine the design parameters of the cam, follower and the tube. To verify the feasibility of the experiment, a prototype was manufactured and its operating characteristics were investigated. Experimental results were in accordance with the expected results obtained from analysis.

Development of physically based 3D computer simulation code TRICSI for ion implantation into crystalline silicon

  • Son, Myung-Sik;Lee, Jun-Ha;Hwang, Ho-Jung
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.1 no.1
    • /
    • pp.1-12
    • /
    • 1997
  • A new three-dimensional (3D) Monte Carlo ion implantation simulator, TRICSI, has been developed to investigate 3D mask effects in the typical mask structure for ion implantation into crystalline silicon. We present the mask corner and mask size effects of implanted boron range profiles, and also show the calculated damage distributions by applying the modified Kinchin-Pease equation in the single-crystal silicon target. The simulator calculates accurately and efficiently the implanted-boron range profiles under the relatively large implanted area, using a newly developed search algorithm for the collision partner in the single-crystal silicon. All of the typical implant parameters such as dose, tilt and rotation angles, in addition to energy can be used for the 3D simulation of ion implantation.