• Title/Summary/Keyword: implant stability

Search Result 495, Processing Time 0.027 seconds

상악동저 점막 거상술을 이용한 인공치아 임프란트 동시 식립술 후 예후에 관한 임상적 연구 (SUBANTRAL AUGMENTATION WITH AUTOGENOUS BONE GRAFT FOR SIMULTANEOUS IMPLANT INSTALLATION)

  • 김명진;김태영;황경균;유상진;명훈;김수경;김종원;김규식
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권6호
    • /
    • pp.644-651
    • /
    • 2000
  • In cases of severe alveolar bony resorption in the edentulous posterior maxillae, implant placement is limited anatomically due to maxillary sinus. If the ridge is atrophic, the various bone grafting methods are required for the ridge augmentation. But the result of the onlay grafting procedure is not always promising. On the posterior maxilla, maxillary sinus mucosa lifting and bone grafting into the sinus floor, subantral augmentation(SA) technique are recommended. Various SA procedures have been developed for implant installation. We perfer to simultaneous block bone graft and implant installation through the residual alveolar ridge into the grafted block bone to fix the grafted bone and to gain the primary stability of the installed fixture. When a sagittal skeletal discrepancy in present due to the severe alveolar bony resorption of the maxilla, the advancement of the maxilla by Le Fort I osteotomy simultaneously with installation of implant fixtures combined with sinus lifting and interpositional bone graft procedure can be indicated. We applied various SA techniques for implant installtion to the 46 edentulous posterior maxillae, and total 154 implants were installed at our department from 1992 to 1999. Various SA techniques were classified in detail and the indications of each techniques were discussed. The changes of residual bony height following SA procedure were studied. The results were as follows. 1. The SA procedure combined with bone graft and simultaneous fixture installation were performed in 41 cases, 126 fixtures were installed and 5 fixtures were removed out of them. Le Fort I osteotomy procedure combined with sinus lifting and interpositional bone graft simultaneous with fixture installation were performed in 5 cases. Total 28 fixtures were installed and 2 fixtures were removed so far. 2. Autogenous block bone graft into sinus floor were performed in 35 cases, autogenous particulated marrow cancellous bone(PMCB) graft in 9 cases, and demineralized human bone powder in 2 cases. The donor site for bone graft were anterior iliac bone in 39 cases, posterior iliac bone in 3 cases and mandibular symphysis in 1 case and mandibular ramus in 1 case. 3. In 9 cases with which SA procedure had been performed with the block bone graft, the change of pre- and postoperative residual bony height were measured using MPR(multiplanar reformatted)-CT. The mean residual bony height was 8.0mm preoperatively, 20.2mm at 6 months following up operation and we gained average 12.2mm alveolar bony height. So, we can recommend this one-stage subantral augmentation and fixture installation technique as a time conserving, safe and useful method for compromised posterior edentulous maxilla.

  • PDF

Volumetric stability of autogenous bone graft with mandibular body bone: cone-beam computed tomography and three-dimensional reconstruction analysis

  • Lee, Hyeong-Geun;Kim, Yong-Deok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제41권5호
    • /
    • pp.232-239
    • /
    • 2015
  • Objectives: The purpose of this study was to estimate the volumetric change of augmented autobone harvested from mandibular body cortical bone, using cone-beam computed tomography (CBCT) and three-dimensional reconstruction. In addition, the clinical success of dental implants placed 4 to 6 months after bone grafting was also evaluated. Materials and Methods: Ninety-five patients (48 men and 47 women) aged 19 to 72 years were included in this study. A total of 128 graft sites were evaluated. The graft sites were divided into three parts: anterior and both posterior regions of one jaw. All patients included in the study were scheduled for an onlay graft and implantation using a two-stage procedure. The dental implants were inserted 4 to 6 months after the bone graft. Volumetric stability was evaluated by serial CBCT images. Results: No major complications were observed for the donor sites. A total of 128 block bones were used to augment severely resorbed alveolar bone. Only 1 of the 128 bone grafts was resorbed by more than half, and that was due to infection. In total, the average amount of residual grafted bone after resorption at the recipient sites was $74.6%{\pm}8.4%$. Conclusion: Volumetric stability of mandibular body autogenous block grafts is predictable. The procedure is satisfactory for patients who want dental implants regardless of atrophic alveolar bone.

Physical stability of arginine-glycine-aspartic acid peptide coated on anodized implants after installation

  • Huh, Jung-Bo;Lee, Jeong-Yeol;Jeon, Young-Chan;Shin, Sang-Wan;Ahn, Jin-Soo;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.84-91
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the stability of arginine-glycine-aspartic acid (RGD) peptide coatings on implants by measuring the amount of peptide remaining after installation. MATERIALS AND METHODS. Fluorescent isothiocyanate (FITC)-fixed RGD peptide was coated onto anodized titanium implants (width 4 mm, length 10 mm) using a physical adsorption method (P) or a chemical grafting method (C). Solid Rigid Polyurethane Foam (SRPF) was classified as either hard bone (H) or soft bone (S) according to its density. Two pieces of artificial bone were fixed in a customized jig, and coated implants were installed at the center of the boundary between two pieces of artificial bone. The test groups were classified as: P-H, P-S, C-H, or C-S. After each installation, implants were removed from the SRPF, and the residual amounts and rates of RGD peptide in implants were measured by fluorescence spectrometry. The Kruskal-Wallis test was used for the statistical analysis (${\alpha}$=0.05). RESULTS. Peptide-coating was identified by fluorescence microscopy and XPS. Total coating amount was higher for physical adsorption than chemical grafting. The residual rate of peptide was significantly larger in the P-S group than in the other three groups (P<.05). CONCLUSION. The result of this study suggests that coating doses depend on coating method. Residual amounts of RGD peptide were greater for the physical adsorption method than the chemical grafting method.

Cervical spine reconstruction after total vertebrectomy using customized three-dimensional-printed implants in dogs

  • Ji-Won Jeon;Kyu-Won Kang;Woo-Keyoung Kim;Sook Yang;Byung-Jae Kang
    • Journal of Veterinary Science
    • /
    • 제25권1호
    • /
    • pp.2.1-2.14
    • /
    • 2024
  • Background: Sufficient surgical resection is necessary for effective tumor control, but is usually limited for vertebral tumors, especially in the cervical spine in small animal neurosurgery. Objective: To evaluate the primary stability and safety of customized three-dimensional (3D)-printed implants for cervical spine reconstruction after total vertebrectomy. Methods: Customized guides and implants were designed based on computed tomography (CT) imaging of five beagle cadavers and were 3D-printed. They were used to reconstruct C5 after total vertebrectomy. Postoperative CT images were obtained to evaluate the safety and accuracy of screw positioning. After harvesting 10 vertebral specimens (C3-C7) from intact (group A) and implanted spines (group B), implant stability was analyzed using a 4-point bending test comparing with groups A and C (reconstituted with plate and pins/polymethylmethacrylate after testing in Group A). Results: All customized implants were applied without gross neurovascular damage. In addition, 90% of the screws were in a safe area, with 7.5% in grade 1 (< 1.3 mm) and 2.5% in grade 2 (> 1.3 mm). The mean entry point and angular deviations were 0.81 ± 0.43 mm and 6.50 ± 5.11°, respectively. Groups B and C significantly decreased the range of motion (ROM) in C3-C7 compared with intact spines (p = 0.033, and 0.018). Both groups reduced overall ROM and neutral zone in C4-C6, but only group B showed significance (p = 0.005, and 0.027). Conclusion: Customized 3D-printed implants could safely and accurately replace a cervical vertebra in dog cadavers while providing primary stability.

이개연골과 측두근막의 자가복합이식술에 의한 외상성 복시현상과 안구함몰의 치험례 (CORRECTION OF POSTTRAUMATIC DIPLOPIA AND ENOPHTHALMOS USING AUTOGENOUS COMPOSITE CONCHAL CARTILAGE AND TEMPORAL FASCIAL;A CASE REPORT)

  • 김일규;이성준;하수용
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제12권1호
    • /
    • pp.114-120
    • /
    • 1990
  • This is a case report of correction of posttraumatic diplopia and enophthalmos using autogenous composite conchal cartilage and temporal fascia. The results are as follows. 1. Diplopia and enophthalmos may be persistent complications in zygomatic complex fracture. 2. The concha is a reservior of autogenous cartilage which leaves no cosmetic and functional deformity in reconstruction of orbital floor. 3. Warpping the cartilage in temporal fascia may serve to increase implant stability and get graft with smooth edge. 4. Donor incision lines are well hidden within the scalp and in auriculocephalic fold.

  • PDF

성인 교정치료를 위한 피질골절단술(Corticotomy)의 임상 적용 (CLINICAL USE OF CORTICOTOMIES IN ADULT ORTHODONTICS)

  • 이백수;황혜욱;정규림
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제21권3호
    • /
    • pp.303-311
    • /
    • 1999
  • In adult patients, the corrections of their malocclusion may be more difficult and require longer treatment time due to thicker layer of cortical bone and reduced blood supply. Recently, various methods such as surgery, implant for anchorage and corticotomy have been tried to overcome these problems. Corticotomy is a surgical technique in which a fissure is made through the cortical bone that surrounds a tooth so that the tooth is embedded within a block of bone that is connected to adjacent blocks through only the medullary bone. Technique of corticotomy has been widely used for correction of maxillary transverse deficiency, but hasn't actively in other fields of orthodontics. We applied corticotomies in many types of orthodontic treatment and had satisfactory results. We suggested clinical application of corticotomy in adult orthodontics to reduce treatment period and to achieve better stability after orthodontic treatment.

  • PDF

$TiSi_2$ SALICIDE CONTACT의 전기적 특성 (Electrical Characteristics of $TiSi_2$ Salicide Contact)

  • 이철진;양지운;이내인;성영권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.178-182
    • /
    • 1991
  • Contact resistance and contact leakage current of the $Al/TiSi_2/Si$ system are investigated for $N^+\;and\;P^+$ junctions. Titanium disilicide is one of the most common silicides because of its thermal stability, ability, to form selective formation and low resistivity. In this paper, the effect of RTA temperature and Junction implant dose are characterized. The $TiSi_2$ contact resistance to $N^+$ silicon is lower than that of Al to $N^+$ silicon, but $TiSi_2$ of contact resistance to $P^+$ silicon is higher than that of Al to $P^+$ silicon. The $TiSi_2$ of contact leakage current to $N^+\;and\;P^+$ silicon is similar to that of Al contact.

  • PDF

Ti Self-Aligned Silicide를 이용한 Contact에서의 전기적 특성 (Electrical Characteristics of Ti Self-Aligned Silicide Contact)

  • 이철진;허윤종;성영권
    • 대한전기학회논문지
    • /
    • 제41권2호
    • /
    • pp.170-177
    • /
    • 1992
  • Contact resistance and contact leakage current of the Al/TiSiS12T/Si system are investigated for NS0+T and PS0+T junctions. SALICIDE (Self Aligned Silicide) process was used to make the Al/TiSiS12T/Si system. Titanium disilicide is one of the most common silicides because of its thermal stability, ability to form selective formation and low resistivity. In this paper, RTA temperature effect and Junction implant dose effect were evaluated to characterize contact resistance and contact leakage current. The TiSiS12T contact resistance to NS0+T silicon is lower than that to PS0+T silicon, and TiSiS12T of contact leakage current to NS0+T silicon is lower than that to PS0+T silicon. Contact resistance and contact leakage current of the Al/TiSiS12T/Si system by this method were possible for VLSI application.

Ridge augmentation in implant dentistry

  • Kim, Young-Kyun;Ku, Jeong-Kui
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권3호
    • /
    • pp.211-217
    • /
    • 2020
  • In patients with insufficient bone height and width, the successful placement of dental implants is difficult with regards to maintaining an ideal pathway and avoiding important anatomical structures. Vertical and/or horizontal ridge augmentation may be necessary using various bone substitute materials and bone graft procedures. However, effective one-wall reconstruction has been challenging due to its poor blood supply and insufficient graft stability. In this paper, the authors summarize current evidence-based literature based on the author's clinical experience. Regarding bone substitutes, it is advantageous for clinicians to select the types of bone substitutes including autogenous bone. The most important consideration is to minimize complications through principle-based ridge augmentation surgery. Ridge augmentation should be decided with complete consent of the patients due to the possible disadvantages of surgery, complications, and unpredictable prognosis.

Immediate Loading of Narrow Diameter Implants at the Mandibular Incisor Area Using Full Digital Flow: A Case Report

  • Ahn, Ji Ho;Lim, Young-Jun;Baek, Yeon-Wha;Lee, Jungwon
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.92-99
    • /
    • 2022
  • This case report describes the immediate loading of narrow diameter implants in the mandibular incisor area using full-digital flow. The 3-dimensional position of the implants was planned using digital software, and the corresponding surgical template was fabricated. The implants were inserted immediately after extraction and on the same day, the interim abutment and bridge were placed. At 8 weeks after surgery, the stability of the implants was measured and a digital impression was made using a scan body. Customized titanium abutments and a cement-type full zirconia bridge were delivered. At 36 weeks' follow-up, no clinical or radiographic complications were detected, and the patient was satisfied with the results.