• Title/Summary/Keyword: implant restoration

Search Result 366, Processing Time 0.025 seconds

Influence of crown-to-implant ratio of short vs long implants on implant stability and marginal bone loss in the mandibular single molar implant (하악 구치 단일임플란트 수복에서 임플란트 길이에 따른 치관-임플란트 비율이 임플란트안정성 및 변연골소실에 주는 영향)

  • Baek, Yeon-Wha;Kim, Bongju;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.280-289
    • /
    • 2018
  • Purpose: The purpose of this randomized clinical trial is to determine whether implant length and the crown-to-implant (C/I) ratio influence implant stability and peri-implant marginal bone loss (MBL). Materials and Methods: 46 patients with single tooth missing in the posterior molar region of the mandible were included in this study. 19 implants (CMI IS-III $active^{(R)}$ long implant) of 5.0 mm diameter and 10 mm length were installed for the control group, while 27 implants (CMI IS-III $active^{(R)}$ short implant) of 5.5 mm diameter and 6.6, 7.3 or 8.5 mm length were placed for the experimental group. Each implant was inserted and immediately loaded using the digitally pre-fabricated surgical template and provisional restoration. The CAD-CAM monolithic zirconia crown was fabricated at 3 months after the surgery as a definitive restoration. The ISQ value and the MBL was measured at 48 weeks after the surgery. The correlation between the C/I ratio, MBL, and secondary implant stability was analyzed. Results: Successful results in terms of ISQ and MBL were achieved with both groups. There was no significant difference between the groups in terms of ISQ values and MBL at 48 weeks after the surgery (P > 0.05). No significant correlation was found between the C/I ratio and secondary stability as well as the C/I ratio and the MBL (P > 0.05). Conclusion: The influence of C/I ratio in both groups was not shown on the stability nor the marginal bone loss in implants supporting single crown of the mandible. Short implant could be a preferable alternative option in the reduced bone height mandible under the limited condition despite its higher C/I ratio.

Minimal invasive horizontal ridge augmentation using subperiosteal tunneling technique

  • Kim, Hyun-Suk;Kim, Young-Kyun;Yun, Pil-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.41.1-41.6
    • /
    • 2016
  • Background: The goal of this study was to retrospectively evaluate the prognosis of minimal invasive horizontal ridge augmentation (MIHRA) technique using small incision and subperiosteal tunneling technique. Methods: This study targeted 25 partially edentulous patients (10 males and 15 females, mean age $48.8{\pm19.7years$) who needed bone graft for installation of the implants due to alveolar bone deficiency. The patients took the radiographic exam, panoramic and periapical view at first visit, and had implant fixture installation surgery. All patients received immediate or delayed implant surgery with bone graft using U-shaped incision and tunneling technique. After an average of 2.8 months, the prosthesis was connected and functioned. The clinical prognosis was recorded by observation of the peri-implant tissue at every visit. A year after restoration, the crestal bone loss around the implant was measured by taking the follow-up radiographs. One patient took 3D-CT before bone graft, after bone graft, and 2 years after restoration to compare and analyze change of alveolar bone width. Results: This study included 25 patients and 39 implants. Thirty eight implants (97.4 %) survived. As for postoperative complications, five patients showed minor infection symptoms, like swelling and tenderness after bone graft. The other one had buccal fenestration, and secondary bone graft was done by the same technique. No complications related with bone graft were found except in these patients. The mean crestal bone loss around the implants was 0.03 mm 1 year after restoration, and this was an adequate clinical prognosis. A patient took 3D-CT after bone graft, and the width of alveolar bone increased 4.32 mm added to 4.6 mm of former alveolar bone width. Two years after bone graft, the width of alveolar bone was 8.13 mm, and this suggested that the resorption rate of bone graft material was 18.29 % during 2 years. Conclusions: The bone graft material retained within a pouch formed using U-shaped incision and tunneling technique resulted with a few complications, and the prognosis of the implants placed above the alveolar bone was adequate.

Restoration of IARPD in partially edentulous patients with bone defects due to osteomyelitis treatment (골수염 치료로 인해 골결함이 있는 부분무치악 환자에서 IARPD 수복)

  • Park, Se-Hyun;Sung, Han-Gyul;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.359-369
    • /
    • 2021
  • Implant prostheses and removable partial dentures are mainly used as treatment methods for partial edentulous patients who have lost a number of teeth. The implant-assisted removable partial denture (IARPD) is strategically selected. The defect in maxillofacial structure due to osteomyelitis, a type of facial bone infection, causes dysfunction such as mastication, swallowing, and pronunciation, as well as social and psychological effects, so a removable restoration is required to restore the supporting tissue. Design of abutment and partial dentures is an essential factor in the success of treatment. In this case, IARPD, which has superior retention and stability compared to traditional removable partial dentures, can have a good prognosis. In a partial edentulous patient with bone defects due to osteomyelitis treatment, the stability of the denture was secured with IARPD restoration. Moreover, maintenance problem that may occur in the future was minimized by providing an appropriate denture design and occlusal scheme through several provisional restorations. This case can be expected to have a favorable prognosis in the long term.

Management of prosthodontic patients with severe gag reflex using the questionaire and behavior technique: A case report (심한 구역반사를 보이는 환자에서 문진표와 행동 요법을 이용한 임플란트 고정성 보철 수복 증례)

  • Sohn, Changmo;Kim, Yu-Jin;Lee, Cheon-Seo;Choi, Na-Rae;Kwon, Eun-Young;Kim, So-Yeun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.333-340
    • /
    • 2021
  • Although gag reflex is an essential function and a useful physiological defense mechanism, it can become an obstacle in a dental treatment. In this case, a questionnaire was designed and used in consultations to objectify the factors associated with gag reflex. Based on the questionnaire, various treatment protocols were planned, such as behavioral control, which is a systematic desensitization that adapts by placing dental instruments in the oral cavity, and habit control to eliminate vomiting habits after drinking. Except for the placement of the implant fixture under general anesthesia, all restoration procedures were performed in the outpatient clinic in the same manner as the conventional implant fixed prosthetic restoration. The systematic desensitization and behavior technique were repeated until the patient was able to endure discomfort and relieve gag reflex in dental treatment. The patient was successfully received the implant-fixed prosthetic restoration in the partial edentulous region.

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.

The implant overdenture on the edentulous mandible using CAD/CAM system: A case report (CAD/CAM system을 이용한 하악 임플란트 피개의치 수복증례)

  • Lee, Si-Eun;Lee, So-Hyoun;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.66-73
    • /
    • 2015
  • Alveolar bone loss and deformation can be a risk factor in removable prosthetic restoration treatment for partially or fully edentulous patients. The use of implants to solve this problem could improve the support, retention and stability of removable restoration. Attachments used in implant overdenture are versatile. The attachment should be selected according to the patients' conditions. Milled bar has been chosen when readymade bar could not be used because of the narrow distance between implants or firm stability and support of supra-structure were needed. Milled bar design is able to provide cross arch stabilization and comfortability to patients. However, it needs skilled laboratory procedures. Recently, the fabrication of milled bar has become simple and its suitability has been improved through the development of CAD/CAM system. In a 67-year-old female Alzheimer's disease patient with 8 implant fixtures on the fully edentulous site of mandible, implant overdenture with using milled bar and magnet attachment was planned. As rapid treatment was required, CAD/CAM system was used to make a simple laboratory procedure instead of a traditional fabrication process. With this system, implant overdenture with milled bar can be fabricated esthetically and functionally.

The comparison between 2 wide implants and 3 regular implants in mandibular posterior area (하악 대구치부위의 고정성 보철물에서 2개의 장폭경과 3개의 표준 임프란트의 비교)

  • Yoo, Ho-Sun;So, Sung-Soo;Han, Dong-Hoo;Cho, Kyoo-Sung;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.577-588
    • /
    • 2002
  • Osseointegrated implants have been established as the standard treatment modality for full/partial edentulous patients since the 1960's, and the long term results for full edentulous patients have proven to be successful. Based on these results osseointegrated implants are now widely used for partial edentulous patients. There has been an increased interest towards the efficacy of wide implants, despite many reports mentioning the lower success rate of wide implants compared to regular implants. Recently, mandibular molar area defects are commonly restored using 2 wide implants, but it is not determined whether which treatment modality-3 regular implants or 2 wide implants-shows superior success rate. In this study, 2 wide implants and 3 regular implants used for the restoration of mandibular molar area are used to compare the survival rate of 1-4 years, and to analyze and compare the failure factors. The following conclusions could be drawn from this study. 1. Wide implants and regular implants showed 94.5% and 97,6% of survival rate respectively. After prosthodontic work, the survival rate was 100% and 98.1% for wide implants and regular implants respectively. 2. 5 failed implants have been removed. 2 wide implants and 1 regular implant have been removed due to failure of osseointegration. 1 wide implant was removed due to abscess formation caused by over-heating, and 1 regular implant was removed due to mechanical failure caused by over-loading within the first year of function. 3. No statistically significant difference was observed with respect to the amount of marginal bone loss of wide and regular implants.(P>0.05) In conclusion, restoration of the mandibular molar area using 3 regular implants was found to be a good treatment modality, and 2 wide implants could he considered a good treatment modality when success factors are taken into account.

Naturalization of Implant Prostheses (자연감 있는 임플란트 보철물)

  • Kim, Dae-Hyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.8 no.1
    • /
    • pp.96-103
    • /
    • 1999
  • Restoration of missing oral tissues by using implant therapy is one of viable options in prosthodontic treatment. The purpose of oral rehabilitation are function, esthetics and phonetics. Recently, with the increasing esthetic demand of the patient, dentists and laboratory technicians are more concern ed about natural appearance of implant prostheses. There are so many factors which affect final esthetic results of treatment such a shape, color, proportion, gingival contour etc. To provide natural and vivid looking artificial prostheses to a patient, the careful diagnosis, treatment plan and laboratory Support is crucial. Several cases will be reviewed and discussed in terms of material, gingival shape, contour, speech and connection mode etc. to fabricate natural looking implant prostheses.

  • PDF

Clinical Evaluation of Simultaneous Implants Placement Following Augmentation of the Maxillary Sinus with Deproteinized Bovine Bone (탈단백 우골을 이용한 상악동 거상술 후 즉시 임플란트 식립에 대한 임상적 평가)

  • Kim, Hyun-Kuk;Kim, Jin-Wook;Kim, Chin-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.3
    • /
    • pp.249-255
    • /
    • 2011
  • Purpose: Placement of endosseous implants in the atrophic maxilla is often restricted because of the lack of supporting bone. In this article, augmentation of the maxillary sinus floor with deproteinized bovine bone to enable insertion of endosseous implants is described. The technique is aimed at providing a cortical layer on top of the graft to ensure a reliable seal of the maxillary sinus and to achieve optimal stability of the bone graft in case of simultaneously placement of dental implants. Methods: The procedure was used in 200 patients (839 implants), using deproteinized bovine bone. The mean follow-up was 28.5 months. No inflammation of the bone grafts nor of the maxillary sinus occurred. The patients received implant supported overdentures or bone-anchored bridges. Results: The survival rate of implant restoration of this study was 97.6%. The total average of marginal bone loss in radiographs was $0.20{\pm}0.38$ mm. Insufficient primary stability, bony quality, and infection were thought to be associated factors in the failed cases. Conclusion: This study documented that deproteinized bovine bone, when used as a grafting material for augmentation of the sinus floor, may lead to proper osseointegration of a endosseous implant.

THE MANAGEMENT OF A COMPLEX IMPLANT CASE USING CAD-CAM TECHNOLOGY: A CLINICAL REPORT

  • Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.634-638
    • /
    • 2008
  • PURPOSE: The application of computer-aided technology to implant dentistry has created new opportunities for treatment planning, surgery and prosthodontic treatment, but the correct selection and combination of available methods may be challenging in times. Hence, the purpose of this case report is to present a combination of several computer-aided tools as approaches to manage complicated implant case. MATERIAL AND METHODS: A 47 year-old female patient with severe dental anxiety, high expectations, financial restrictions and poor compliance presented for a fixed rehabilitation. A CT scan with a radiographic template obtained with software (SimPlant, Materialize, Leuven, Belgium) was used for treatment planning. The surgical plan was created and converted into a stereolithographic model of the maxilla with bone-supported surgical templates (SurgiGuide, Materialise, Leuven, Belgium), that allowed for the precise placement of 7 implants in a severely resorbed edentulous maxilla. After successful osseointegration, an accurate scan model served as the basis for the fabrication of a one-piece milled titanium framework using the Procera (Nobel Biocare, Gothenburg, Sweden) technology. The final rehabilitation of the edentulous maxilla was rendered in the form of a screw-retained maxillary metal-reinforced resin-based complete prosthesis. RESULTS: Despite challenging circumstances, 7 implants could be placed without bone augmentation in a severely resorbed maxilla using the SimPlant software for pre-implant analysis and the SurgiGuide-system as the surgical template. The patient was successfully restored with a fixed full arch restoration, utilizing the Procera system for the fabrication of a milled titanium framework.