• Title/Summary/Keyword: implant guide

Search Result 111, Processing Time 0.025 seconds

Computer-guided implant surgery and immediate provisionalization by chair-side CAD-CAM: A case report (진료실 CAD-CAM에 의한 컴퓨터 가이드 임플란트 수술과 즉시 임시보철치료: 증례보고)

  • Hyun, Sang Woo;Lee, sungbok Richard;Lee, Suk Won;Cho, Young Eun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.478-486
    • /
    • 2021
  • This report demonstrates a method of generating a chair-side and computer-aided template for implant surgery based on the Top-Down and restoration-driven concept. Compared to the traditional CAD-CAM process which requires multiple steps to be taken between dental clinic and laboratory, this alternative procedure, VARO guide system (VARO Guide, CAD, Pre-Guide, VARO-mill, NeoBiotech, Seoul, South Korea) enables accurate and patient-friendly implant surgery as well as immediate provisional restoration in a single visit. First, bite-registration at centric jaw relation and CBCT were taken using the Pre-Guide. The CBCT data was then reorganized directly through the chair-side CAD, and we could determine the most appropriate 3-dimensional position of implant. The STL file was extracted and put into the chair-side CAM (VARO-mill) to fabricate a VARO. This surgical guide allowed the implants to be accurately positioned into the planned sites within an hour.

Full mouth rehabilitation with Implant-Guided Surgery and Fixed prosthesis (Implant-Guided Surgery를 이용한 고정성 임플란트 보철물의 전악 수복 증례)

  • Kim, Seong-Mo;Park, Jin-Hong;Ryu, Jae-Jun;Shin, Sang Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.126-133
    • /
    • 2018
  • The development of cone beam computerized tomography (CBCT) allows three-dimensional analysis of the patient's anatomy. The surgical guide is a combination of CBCT, computer-aided design/computer-aided manufacturing (CAD/CAM) and implant diagnostics software, which allows well planned prostheses design and ideal implant placement. Guided surgery minimizes possible anatomical damage and allows for more reproducible treatment planning. In this case, the operation time was shortened by using a surgical guide for multiple implants placement in a fully edentulous patient. Immediate loading were performed more easily using preliminary preparation of provisional prosthesis. The patient was satisfied with improved esthetics and chewing function.

Full mouth rehabilitation of a patient with severe periodontitis using immediate loading after computer aided flapless implant surgery (심한 치주질환을 가진 환자에서 computer aided flapless surgery와 즉시 부하를 통한 전악 구강 회복 증례)

  • Kang, Seong hun;Choi, Yeon jo;Ryu, Jae jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.46-55
    • /
    • 2018
  • Oral rehabilitation of a patient having severe periodontitis with alveolar bone resorption and periodontal inflammation presents a challenge to clinicians. However, if appropriate implant placement according to the bone shape is selected, unnecessary bone grafting or soft tissue surgery can be minimized. In recent years, using cone beam CT and software, it has become possible to operate the planned position with the surgical guide made with 3D printing technology. This case was a 70 years old female patient who required total extraction of teeth due to severe periodontitis and performed a full-mouth rehabilitation with an implant - supported fixed prosthesis. During the surgery, the implant was placed in a flapless manner through a surgical guide. Immediate loading of the temporary prosthesis made by CAD/CAM method before surgery was done. Since then, we have produced customized abutments and zirconia prostheses, and have reported satisfactory aesthetic and functional recovery.

Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model

  • Choi, Yoon-Sil;Oh, Jae-Woon;Lee, Young;Lee, Dong-Woon
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.5
    • /
    • pp.411-421
    • /
    • 2022
  • Purpose: In this study, we aimed to evaluate the degree of heat generation when a novel drill design with an irrigation slot was used with metal sleeve-free (MF) and metal sleeve-incorporated (MI) surgical guides in an environment similar to that of the actual oral cavity. Methods: A typodont with a missing mandibular right first molar and 21 bovine rib blocks were used. Three-dimensional-printed MF and MI surgical guides, designed for the placement of internal tapered implant fixtures, were used with slot and non-slot drills. The following groups were compared: group 1, MI surgical guide with slot drill; group 2, MI surgical guide with a non-slot drill; and group 3, MF surgical guide with a slot drill. A constant-temperature water bath at 36℃ was used. The drilling was performed in 6 stages, and the initial, highest, and lowest temperatures of the cortical bone were measured at each stage using a non-contact infrared thermometer. Results: There were no temperature increases above the initial temperature in any drilling procedure. The only significant difference between the non-slot and slot groups was observed with the use of the first drill in the MI group, with a higher temperature in the non-slot group (P=0.012). When the heat generation during the first and the second drilling was compared in the non-slot group, the heat generation during the first drilling was significantly higher (P<0.001), and there was no significant difference in heat generation between the drills in the slot group. Conclusions: Within the limitations of this study, implant-site preparation with the surgical guide showed no critical increase in the temperature of the cortical bone, regardless of whether there was a slot in the drill. In particular, the slotted drill had a cooling effect during the initial drilling.

Film Image Transfer System (FITS): An Efficient Method for Proper Positioning of Orthodontic Mini-implants

  • Go, Taek-Su;Kim, Seong-Hun;Nelson, Gerald
    • Journal of Korean Dental Science
    • /
    • v.4 no.1
    • /
    • pp.20-25
    • /
    • 2011
  • Purpose: To describe the newly developed Film image transfer system (FITS) for proper positioning of the orthodontic mini-implant in the narrow interdental space and considerations for better application. Materials and Methods: A patient who was planning to have orthodontic mini-implant treatment on the posterior maxilla was recruited to assess the feasibility of FITS. Dental radiographic film and bite record was taken. And then the film image was transferred on the photographic emulsion coated model using transfer light through film projector (enlarger). After exposing the photo emulsion coating on the model, the image was developed with a working solution for a paper developer and fixed. The surgical guide for the mini-implant was fabricated from the transported FITS data. Results: The completed surgical guide was easily placed intraorally, and allowed a simple and rapid placement of the mini-implant. The site of the implant placement was accurate as planned position. Conclusion: In the reported case, The FITS technique represents an effort to minimize risk to the patient and produce consistently good results based upon accurate information about the anatomy of the implant site.

Implant-assisted Removable Prosthetic Rehabilitation of a Patient with Crossed Occlusion

  • Oh, Hyun-Su;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • Journal of Korean Dental Science
    • /
    • v.14 no.1
    • /
    • pp.32-39
    • /
    • 2021
  • 'Crossed occlusion' is the condition in which occlusal intercuspation is lost when several teeth on upper and lower jaw remain. This report describes a clinical case in which a patient had two upper-left posterior teeth and two lower-right posterior teeth; typically known as left-right crossed occlusion. Considering the patient's general condition and financial situation, the treatment plan included placement of two implants on each jaw against the remaining teeth using surgical guide. To find out the ideal position of implants, digital diagnostic wax-up was preceded by superimposing the cast and cone beam computed tomography image, which was aided with radiographic stents. The consequent surveyed implant bridge provided stable vertical stop for fabrication of the implant assisted removable partial dentures. The patient was satisfied with the functionality and esthetics of definitive prosthesis.

An analysis on satisfaction level of clinicians on implant surgical guidance system based on computed tomography (컴퓨터 단층 촬영을 기반으로 한 임플란트 가이드 시스템에 대한 임상가의 만족도 분석)

  • Hong, Min-ho;Jin, Ming-Xu;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.178-185
    • /
    • 2015
  • Purpose: The purpose of this study was to conduct a comparative assessment on the satisfaction level for the two interfaces of surgical guide system (SimPlant and R2GATE), the design and convenience of manufactured surgical guides and the importance of using the surgical guides thereof by means of survey. Materials and Methods: Hereupon, they simulated the implant surgical process by mounting the two manufactured systems of surgical guide on a dental mold, respectively. The study subjects were instructed to complete the questionnaire as to the satisfaction level upon completion of the simulated surgery. This study summarized the data of each question after collecting the completed questionnaires. Then, this study analyzed the summarized data by utilizing statistical program SPSS 20.0 (IBM). Results: R2GATE had a higher value of the satisfaction level on the design and convenience of manufactures surgical guides. R2GATE group ($7.33{\pm}1.26$) was found to have a higher value in terms of the overall satisfaction level compared to SimPlant group ($6.67{\pm}1.26$) (${\alpha}$ = 0.05). Conclusion: The user satisfaction level on the surgical guide manufactured for R2GATE system was to such an extent as it can be widely used in clinical environment. Moreover, the surgical guide manufactured as R2GATE system can guide both the length and direction of a drill simultaneously. As a result, it is highly recommended for those beginners who do not have a lot of experience in implant placement.

Effects of a modified surgical protocol on the positional accuracy of dental implants placed using fully guided implant surgery in the partially edentulous posterior ridge with distal extension: a dentiform model study

  • Young Woo Song;Seung Ha Yoo;Ui-Won Jung
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • PURPOSE. The present experiment aimed to evaluate the placement accuracy of fully guided implant surgery using a mucosa-supported surgical guide when the protocol of osteotomy and installation was modified (MP) compared to when the protocol was sequentially and conventionally carried out (CP). MATERIALS AND METHODS. For 24 mandibular dentiform models, 12 dentists (6 experts and 6 beginners) performed fully guided implant placements two times at the right first and second molar sites using a mucosa-supported surgical guide, once by the CP (CP group) and at the other time by the MP (MP group). The presurgical and postsurgical stereolithographic images were superimposed, and the deviations between the virtually planned and actually placed implant positions and the procedure time were compared statistically (P < .05). RESULTS. The accuracies were similar in the CP and MP groups. In the CP group, the mean platform and apex deviations at the second molar site for the beginners were +0.75 mm and +1.14 mm, respectively, which were significantly larger than those for the experts (P < .05). In the MP group, only the mean vertical deviation at the second molar site for the beginners (+0.53 mm) was significantly larger than that for the experts (P < .05). The procedure time was significantly longer for the MP group (+94.0 sec) than for the CP group (P < .05). CONCLUSION. In fully guided implant surgery using a mucosa-supported guide, the MP may improve the placement accuracy when compared to the CP, especially at sites farther from the most-posterior natural tooth.

The use of surgical guide stent for implant placement (임플란트 식립을 위한 수술 가이드의 사용)

  • Lee, Ji-Yeon;Yoon, Ji-Young;Oh, Namsik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.366-375
    • /
    • 2014
  • Surgical guide not only provide diagnosis and treatment plan, but even location and direction of implantation. Surgical guide could be divided into non-limited design, partially limited design, and completely limited design. Partially limited design is easily manufactured and inexpensive but less accuracy, compared to completely limited design. From this approach, partially limited design may be particularly effective in patients who present with a single missing tooth or partially edentulous teeth. Completely limited design is anatomically accuracy, esthetical and functional, optimized treatment for prosthetic and biomechanical perspective, and also minimizes discomfort for post-treatment. The purpose of this study is to review previous studies of various surgical guides and applying in clinic.

Flapless implant surgery on atrophied alveolar ridge in a patient with growth disorder (성장 장애를 가진 부분 무치악 환자에서 위축된 골에 무피판 임플란트 수술 증례)

  • Lee, Du-Hyeong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.170-175
    • /
    • 2014
  • The growth disorder influences craniofacial development and early loss of permanent teeth. This case reports the importance of computerized tomography (CT) and surgical guide to identify horizontal bone loss, adjacent teeth and to guide drills when placing implants in a short stature patient. The patient has idiopathic short stature and the 3rd grade of intellectual disability. To recover posterior mandibular teeth, implant treatment was planned. CT images showed that the adjacent teeth were located markedly to the buccal side. A CT-based surgical guide was fabricated and implants was placed using flapless surgery. Bone dehiscence and fenestration may happen when the surgical guide was fabricated just based on adjacent clinical crowns. Thus, it is essential to analysis bone and teeth and to make surgical guide through CT, especially in atrophied bone on grow disorder patients. Furthermore, systematic researches are recommended to elucidate the relationship between growth disorder and tooth malposition.