• Title/Summary/Keyword: impedance study

Search Result 2,029, Processing Time 0.031 seconds

PZT Impedance-based Damage Detection for Civil Infrastructures (토목 구조물의 PZT Impedance 기반 손상추정기법)

  • S. H. Park;Y. Roh;C. B. Yun;J. H. Yi
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.373-380
    • /
    • 2004
  • This paper presents the feasibility of an impedance-based damage detection technique using piezoelectric (PZT) transducers for civil infrastructures such as steel bridges. The impedance-based damage detection method is based on monitoring the changes in the electrical impedance. Those changes in the electrical impedance are due to the electro-mechanical coupling property of the piezoelectric material and structure. An effective integrated structural health monitoring system must include a statistical process of damage detection that is automated and real time assessment of damage in the structure. Once measured, damage sensitive features from this impedance change can be statistically quantified for various damage cases. The results of the experimental study on three kinds of structural members show that cracks or loosened bolts/nuts near the PZT sensors may be effectively detected by monitoring the shifts of the resonant frequencies. The root mean square (RMS) deviations of impedance functions between before and after damages were also considered as a damage indicator. The subsequent statistical methods using the impedance signature of the PZT sensors were investigated.

  • PDF

Factors influencing the bio-impedance data in tissue segments along the three arm meridians: a pilot study

  • Lim, Chi Eung Danforn;Wong, Felix Wu Shun;Smith, Warren
    • CELLMED
    • /
    • v.1 no.1
    • /
    • pp.7.1-7.9
    • /
    • 2011
  • Bioelectric impedance measurements have been reported to show significant variation between individuals. Different physiological conditions like thickened skin, obesity, and fluid retention can affect the impedance measurement. Therefore, it is important to learn what other factors can affect the measurements of impedance even in healthy individuals. Such information is a prerequisite for understanding the changes in impedance associated with acupuncture treatment. This study investigated the bio-impedance properties of tissue segments in the arms of a number of healthy subjects, so as to define the factors that might influence the variation of the bio-impedance data in acupuncture meridians studies. 51 healthy subjects were recruited through Liverpool Hospital, Sydney. Demographic data was collected from each subject including the age, sex, BMI, and time since most recent meal. Electrodes were applied to the forearms of each test subject. Measurements were done by a purpose-built Bio-Impedance Research Device (BIRD-I) which allowed the determination of core resistance (Rc) and core reactance (Xc) of each of the three meridian tissue segments on the anterior surface of the forearm. No significant difference was found in the core resistance attributable to age group, gender, BMI or meal intake. However, a statistically significant trend in increasing resistance from the radial to ulnar aspect of the forearm (p < 0.001) was found. No significant difference was found in the core resistance of test tissue segments among the 51 healthy subjects measured in this study. However, the trend of increasing core resistance from the radial to ulnar aspects of the arm deserves further investigation.

Classification of Organs Using Impedance of Ultrasonic Surgical Knife to improve Surgical Efficiency (초음파 수술기의 수술 효율성 향상을 위한 진동자 임피던스 측정에 따른 조직 분류 연구)

  • Kim, Hong Rae;Kim, Sung Chun;Kim, Kwang Gi;Kim, Young-Woo
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.141-147
    • /
    • 2013
  • Ultrasonic shears is currently in wide use as an energy device for minimal invasive surgery. There is an advantage of minimizing the carbonization behavior of the tissue due to the vibrational energy transfer system of the transducer by applying a piezoelectric ceramic. However, the vibrational energy transfer system has a pitfall in energy consumption. When the movement of the forceps is interrupted by the tissue, the horn which transfers the vibrational energy of the transducer will be affected. A study was performed to recognize different tissues by measuring the impedance of the transducer of the ultrasonic shears in order to find the factor of energy consumption according to the tissue. In the first stage of the study, the voltage and current of the transducer connecting portion were measured, along with the phase changes. Subsequently, in the second stage, the impedance of the transducer was directly measured. In the final stage, using the handpiece, we grasped the tissue and observed the impedance differences appeared in the transducer To verify the proposed tissue distinguishing method, we used the handpiece to apply a force between 5N and 10N to pork while increasing the value of the impedance of the transducer from 400 ${\Omega}$.. It was found that fat and skin tissue, tendon, liver and protein all have different impedance values of 420 ${\Omega}$, 490 ${\Omega}$, 530 ${\Omega}$, and 580 ${\Omega}$, respectively. Thus, the impedance value can be used to distinguish the type of tissues grasped by the forceps. In the future study, this relationship will be used to improve the energy efficiency of ultrasonic shears.

Basic Study for Cone Penetrometer Type Soil Water Content Sensor using Impedance Spectroscopy (원추 관입형 임피던스 수분센서 개발을 위한 기초 연구)

  • Lee, Dong-Hoon;Lee, Kyou-Seung;Chung, Sun-Ok
    • Journal of Biosystems Engineering
    • /
    • v.34 no.6
    • /
    • pp.434-438
    • /
    • 2009
  • This study was conducted to design an cone penetrometer type impedance sensor that can measure soil water content in realtime. The best width between electrical probe was determined by 5 mm. For optimization about realtime application device, linear regression analysis was applied between soil water content and impedance signal. It was concluded that proper combination of excitation frequency, impedance parameter, and model would provide acceptible performance of a soil waler content sensoe. Best model was obatained at a 36.5 MHz with |Z| as a predictor variable, with a coefficient of determination of 0.96 (RMSE=1.35, RPD=4.98).

A Experimental Study on the Evaluation of Anti-corrosion Performance of rebar in concrete added chloride and inhibitor using EIS method (EIS를 이용한 염화물 및 방청제가 첨가된 콘크리트에 매립된 철근의 방식성능 평가에 관한 실험적 연구)

  • Park, Jang-Hyun;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.134-135
    • /
    • 2016
  • To evaluate anti-corrosion performance of rebar in concrete according to the amount of chloride and inhibitor, electrochemical impedance spectroscopy(EIS) method was conducted in this study. For the anti-corrosion performance evaluation according to time, Impedance of rebar in concrete was measured before and after 5 cycle of corrosion acceleration. As a results, The impedance of rebar in concrete added chloride decreased than before corrosion acceleration. However impedance of other specimens was maintained or increased than before corrosion acceleration.

  • PDF

A Study on the Sound Transmission Loss Measurement of Sound Isolation Sheets (차음시트의 음향투과손실 측정에 관한 연구)

  • Lee, Dong-Hoon;Kang, Moon;Lee, Ju-Weon;Jung, Gab-Cheol;Kwon, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.409-414
    • /
    • 2000
  • A new impedance tube method is presented for the measurement of transmission loss of sound isolation sheets. The two-microphone method based on the sound decomposition theory proposed by Seybert and Ross is reviewed in this impedance tube method, which has been used for the determination of absorption coefficient of absorptive materials as well as transmission loss of automotive mufflers. Sound transmission losses for rubber, polyvinyl and asphalt sheets are measured in an impedance tube and reverberation room facility, respectively. By comparing two measurement methods, the reliability of impedance tube method used in this study is validated. From the experimental results, it is shown that the accuracy of sound isolation capability obtained by the impedance tube method depends upon the microphone spacing and the distance of the first microphone from the test sample surface.

  • PDF

A Study on Applicability of Wireless Impedance Sensor Nodes Technique for Tensile Force Monitoring of Structural Cables (구조용 케이블의 인장력 모니터링을 위한 무선 임피던스 센서노드 기술의 적용성에 관한 연구)

  • Park, Jae-Hyung;Hong, Dong-Soo;Kim, Jeong-Tae;Na, Won-Bae;Cho, Hyun-Man
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.1
    • /
    • pp.21-31
    • /
    • 2010
  • In this study, a technique that uses wireless impedance sensor nodes is proposed to monitor tensile force of structural cable. To achieve this goal, the following approaches were implemented. First, a wireless impedance sensor node was designed for automated and cost-efficient prestress-loss monitoring. Second, an impedance-based algorithm was embedded in the wireless impedance sensor node for autonomous structural health monitoring of structural cables. Third, a tensile force monitoring technique that uses an interface plate for structural cables was proposed to overcome the limitations of the wireless impedance sensor node such as its narrow-band measurable frequency ranges. Finally, the applicability of the wireless impedance sensor node and the technique that uses the interface washer were evaluated in a lab-scaled prestressed concrete (PSC) girder model with internal and external tendons for which several prestress-loss scenarios were experimentally monitored with the wireless impedance sensor nodes.

Impedance Parameter Variations at Intravenous (IV) Infiltration Using Bioelectrical Impedance: A Pilot Study

  • Kim, Jaehyung;Lee, Mansup;Baik, Seungwan;Kim, Gunho;Hwang, Youngjun;Jeon, Gyerok
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.10
    • /
    • pp.1678-1688
    • /
    • 2017
  • Infiltration is one of detrimental problems occurring in nursing or medical settings. Early detection of infiltration is essential to minimize the risk of injury from infiltration. To perform a preliminary study on the point of care and automated infiltration detection system, bioelectrical impedance was investigated using bioelectrical impedance analyzer. We would like to report experimental results that allow impedance parameters to effectively distinguish infiltration. Electrodes were attached to both sides of the transparent dressing on the fusion site where IV solution was being infused. Then, impedance parameters before and after infiltration were measured as a function of time and frequency. The experimental results are as follows. After infiltration was intentionally induced by puncturing the vein wall with a needle, the resistance gradually decreased with time. That is, when an alternating current having a frequency of 20 kHz was applied to the electrodes, the resistance gradually decreased with time, reflecting the accumulation of IV solution in the extracellular fluid since the current could not pass through the cell membrane. Impedance parameters and equivalent circuit model for human cell were used to examine the mechanism of current flow before and after infiltration, which could be used for early detection of infiltration.

Measurement of Blood Flow Variation using Impedance Method (임피던스법을 이용한 혈류량 변화 측정)

  • Jeong Do-Un;Kang Seong-Chul;Jeon Gye-Rock
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.693-696
    • /
    • 2006
  • In this study, we made the system to measure variation of blood flow using bio-electrical impedance analysis method. The system, which could measure variation of impedance according to pressure change by artificial pressure, consists of pressure measurement and impedance measurement by 4-electrode method. Pressure measurement splits into semiconducting pressure sensor and electronic circuit for processing output signal. In addition, impedance measurement splits into constant current source circuit and lock-in amplifier for detection impedance signal. We experimented feature of impedance measurement using standard resistance to evaluate the system characteristic. As well as, we experimented to estimate variation of blood flow by measuring impedance and blood flow resistance ratio using mean arterial pressure and variation of blood flow with experimental group. As result of this study, blood flow resistance ratio and variation of blood flow were definitely in inverse proportion and were -0.96776 as correlation coefficient by correlation analysis.

  • PDF

A Study on the Oscillation Region and the Variation of Negative Resistance in Transistor Oscillators (트란지스터 발진기의 발진영역과 부저항의 변화에 관한 연구)

  • 이종각
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.3
    • /
    • pp.15-26
    • /
    • 1971
  • The paper presents a new method for analyzing oscillation regions of transistor oscillators. In transistor feedback oscillators oscillation region appears as a circle in feedback impedance complex plane. When the resistive component of feedback impedance is fixed and the reactive component of feedback impedance is varied or vice versa, the locus of maximum negative output conductance becomes hyperbola. In transistor crystal oscillators oscillation region is determined by two circles which make real part and imaginary part of input impedance zero in load impedance complex plane. When the resistive compoment of load impedance is fixed and the reactive colnponent of load impedance is varied or vice versa, the loci of maximum or minimum resistive component of input impedance become straight lines.

  • PDF