• Title/Summary/Keyword: impedance ratio

Search Result 566, Processing Time 0.032 seconds

Hydration of Portland Cement Containing Blending Components by Impedance Spectroscopy (임피던스 측정에 의한 혼합재를 포함한 포틀랜드 시멘트의 수화)

  • 송종택;김훈상;배승훈
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.6
    • /
    • pp.540-549
    • /
    • 2002
  • In this work, the hydration behaviour of portland cement pastes containing fly ash, blast-furnace slag and silica fume is investigated by Impedance Spectroscopy(IS). As fly ash or blast-furnace slag was added to portland cement, the values of R$_{t(s+1)}$ and R$_{t(s+1)}$ were decreased in the early hydration period. It showed that hydration of cement containing blending components was slower than it of the reference cement paste with the same W/C ratio. However, the cement paste containing silica fume had a large value of R$_{t(s+1)}$ and R$_{t(int)}$due to very rapid pozzolanic reactivity of silica fume in the hydration time. In OPC-fly ash system, a characteristic plateau region appeared between straight-line and semicircle. The plateau region continued to grow in range with the content of fly ash and the hydration time.

A Study on the Fabrication and the Impedance Matching of SPUDT Type SAW Filter (단상 단방향 형태의 표면탄성파 필터 제작 및 임피던스 정합)

  • You Il-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.602-608
    • /
    • 2005
  • We have studied to obtain the SAW filter for the Single Phase Unidirectional Transduce. (SPUDT), was formed on the Langasite substrate and was evaporated by Aluminum-Copper alloy and then we performed computer-simulated by simulator. We can fabricate that the block weighted type IDT as an input transducer of the filter and the withdrawal weighted type IDT as an output transducer of the filter from the results of our computer-simulations. Also, we have performed to obtain the properly conditions about impedance matching of the SAW filter for SPUDT. We have employed that the number of pairs of the input and output IDT are 50 pairs and the thickness and the width of reflector are 5000A and $3.6{\mu}m$, respectively. And the width of IDT' fingers is $2.4{\mu}m$, and the space between IDT' finger and reflector is $2.0{\mu}m$. Frequency response of the fabricated SAW filter has the property that the center frequency is about 190MHz and bandwidth at the 3dB is probably 7.7MHz after when we have matched impedance. Also, we could obtain that ripple characteristics is less than 0.4dB and standing wave ratio is probably 1.5 after when we have matched impedance.

Design of CPW-fed Slot Antenna for Harmonic Suppression (고조파 억제를 위한 CPW급전 슬롯 안테나 설계)

  • Yeo, Junho;Lee, Jong-Ig
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.1
    • /
    • pp.19-25
    • /
    • 2015
  • In this paper, a design method for a CPW-fed slot antenna for harmonic suppression is studied. The structure of the proposed slot antenna is a rectangular slot antenna appended with stepped impedance resonators (SIRs) at both ends of the slot symmetrically. Optimal design parameters are obtained by analyzing the effects of the length and width of the SIRs on the input reflection coefficient. The optimized harmonic-suppressed slot antenna operating at 2.45 GHz WLAN band is fabricated on an FR4 substrate with a dimension of 42 mm by 30 mm. The slot length of the proposed harmonic-suppressed slot antenna is reduced to 33.3% compared to that of a conventional rectangular slot antenna owing to the appended SIRs. Experiment results show that the antenna has a desired impedance characteristic with a frequency band of 2.39-2.49 GHz for a VSWR < 2, and a measured gain of 2.5 dBi at 2.45 GHz.

Double Boost Power-Decoupling Topology Suitable for Low-Voltage Photovoltaic Residential Applications Using Sliding-Mode Impedance-Shaping Controller

  • Tawfik, Mohamed Atef;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.881-893
    • /
    • 2019
  • This paper proposes a practical sliding-mode controller design for shaping the impedances of cascaded boost-converter power decoupling circuits for reducing the second order harmonic ripple in photovoltaic (PV) current. The cascaded double-boost converter, when used as power decoupling circuit, has some advantages in terms of a high step-up voltage-ratio, a small number of switches and a better efficiency when compared to conventional topologies. From these features, it can be seen that this topology is suitable for residential (PV) rooftop systems. However, a robust controller design capable of rejecting double frequency inverter ripple from passing to the (PV) source is a challenge. The design constraints are related to the principle of the impedance-shaping technique to maximize the output impedance of the input-side boost converter, to block the double frequency PV current ripple component, and to prevent it from passing to the source without degrading the system dynamic responses. The design has a small recovery time in the presence of transients with a low overshoot or undershoot. Moreover, the proposed controller ensures that the ripple component swings freely within a voltage-gap between the (PV) and the DC-link voltages by the small capacitance of the auxiliary DC-link for electrolytic-capacitor elimination. The second boost controls the main DC-link voltage tightly within a satisfactory ripple range. The inverter controller performs maximum power point tracking (MPPT) for the input voltage source using ripple correlation control (RCC). The robustness of the proposed control was verified by varying system parameters under different load conditions. Finally, the proposed controller was verified by simulation and experimental results.

Relationship between the Body Fat Mass Measured by Bioelectrical Impedance Analysis(BIA) and Dual Energy X-ray Absorptiometry(DEXA), and by the Indices of Insulin Sensitivity (생체 임피던스 방법과 이중 방사선 흡수법으로 측정한 체지방량과 인슐린감수성 지표와의 연관성)

  • Lim, In Seok;Yun, Ki Wook
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.8
    • /
    • pp.857-864
    • /
    • 2005
  • Purpose : The objectives of this study was to evaluate the correlations between the indices of insulin sensitivity using fasting glucose and insulin level, and the body fat mass measured by bioelectrical impedance analysis(BIA) and dual energy X-ray absorptiometry(DEXA), and to determine the clinical usefulness of insulin sensitivity indices when obese children were followed up. Methods : In this study, 28 simple obese children and adolescents were included. Anthropometric data including body weight, height, obesity degree(OD), body mass index(BMI), and waist-to-hip ratio were collected and then body fat mass was measured by using BIA and DEXA. For metabolic data, 12 hour fasting serum glucose, insulin and lipid profiles were measured and indices for insulin sensitivity(G/I ratio, $log_{insulin}$, HOMA-IR, $log_{HOMA-IR}$, QUICKI) were calculated. Results : BMI had a higher correlation with insulin sensitivity indices than OD(G/I ratio, -0.463 vs -0.209; $log_{insulin}$, 0.417 vs 0.196; HOMA-IR, 0.301 vs 0.238; $log_{HOMA-IR}$, 0.403 vs 0.198; QUICKI, -0.451 vs -0.224). But OD had a higher correlation with body fat mass measured by BIA and DEXA than BMI(BIA, 0.612 vs 0.316; DEXA, 0.667 vs 0.512). The G/I ratio was correlated with body fat mass in BIA(r=-0.420, P<0.05) and DEXA(r=-0.512, P<0.01), percentage of body fat(percentage of fat) in BIA(r=-0.366, P<0.05) and DEXA(r=-0.449, P<0.01). HOMA-IR was only correlated with body fat mass in DEXA(r=0.341, P<0.05). Conclusion : This study revealed that G/I ratios had a statistically significant correlation with anthropometric obesity indices(OD and BMI) and also had a correlation with both body fat mass and percentage of fat. These results suggest that G/I ratios could be used as useful index when obese children and adolescence are followed up.

Unequal Dual-band Wilkinson Power Divider (비대칭 이중대역 전력분배기)

  • Kim, Byung-Chul;Lee, Soo-Jung;Kim, Young
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.343-348
    • /
    • 2014
  • This paper suggested a theoretical approach and an implementation for the design of an unequal Wilkinson power divider with a high dividing ratio operating at two-frequencies. The T-section transmission lines and the two-section of Monzon's theory are proposed to operate a dual-band application. To achieve the high dividing ratio divider, the high impedance line using a T-shaped structure and low impedance lines with periodic shunt open stubs are implemented. For the validation of this divider, a dual-band power divider with a high dividing ratio of 5 is simulated and measured at 1 GHz and 2 GHz. The measured performances of the divider are in good agreements with simulation results.

The Study on Relation of Obesity and Low Back Pain Based on Body Composition using Segmental Bioelectrical Impedance Analysis and Radiological Parameter (체성분 분석 변수와 X-선 소견을 근거로 한 비만과 요통의 관계 연구)

  • Park, Ji-Hyun;Hong, Seo-Young
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.2
    • /
    • pp.289-302
    • /
    • 2009
  • Objectives : This study was performed in order to investigate the relation of body composition analysis and radiological parameter(lumbosacral angle, lumbar lordortic angle, lumbar gravity line). Methods : This study was carried out with the data from comprehensive medical testing. 75 subject aged 20-59 performed the segmental bioelectrical impedance analysis, questionnaire. And lumbosacral angle, lumbar lordortic angle and lumbar gravity line were measured in the standing position x-ray. Then we analyzed the data. Results : Low back pain(LBP) prevalence in high obesity index(Body Mass Index(BMI), Percentage of Body Fat(PBF), Waist Hip Ratio(WHR)) group was higher than LBP prevalence in normal obesity index group(p<0.01). In LBP group, lumbosacral angle, lumbar lordortic angle were significantly lager than Non-LBP group(p<0.001). And 75% of LBP group indicated abnormal lumbar gravity line ratio(0.67 < Normal lumbar gravity line ratio <1.00). When it comes to analyze relation between obesity index and radiological parameter, no-significant change was seen. Conclusions : This study carried as following research after the study on relation of obesity, LBP and trunk muscle strength. Results from this investigation showed positive correlation between obesity and LBP prevalence. But obesity index didn't indicate significant correlation with structural changes of lumbar vertebrae. When considering prior research, trunk muscle strength changes were more related to LBP prevelence in obese people. This results are expected to explain causes of LBP in obese group.

Design of Ultra-Wide Band Antenna with Compact MCR Structure for BW Enhancement (대역폭 향상을 위한 소형 MCR 구조를 갖는 Ultra-Wide Band 안테나 설계)

  • Nadeem, Iram;Kim, Young-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.4
    • /
    • pp.798-805
    • /
    • 2017
  • This paper presents a low profile multi circular ring with different radius, patch antenna with modified feed line and slotted ground. The size of the antenna is $15{\times}12mm^2$, having electrical dimensions of $0.14{\lambda}{\times}0.12{\lambda}$ (at lower initial frequency) and footprints of $180mm^2$. The proposed antenna covers 3.1 to 12.3 GHz, reflection coefficient up to -38 dB with Bandwidth ratio of 4.13:1 and fractional Bandwidth of 122%. Bandwidth dimension ratio has been calculated (which is 6246) as a proof for compact size. Thin slots introduced on the feed line provide good impedance matching for whole frequency band. Numerical simulations of the proposed antenna are reported in terms of reflection coefficient ${\leq}-10dB$, vswr 2:1, radiation pattern and group delay (ns). The proposed antenna has advantage of very small size along with better impedance match that provides a practical approach to realize it for BW enhancement and UWB applications.

On-Chip Design-for-Testability Circuit for RF System-On-Chip Applications (고주파 시스템 온 칩 응용을 위한 온 칩 검사 대응 설계 회로)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.3
    • /
    • pp.632-638
    • /
    • 2011
  • This paper presents on-chip Design-for-Testability (DFT) circuit for radio frequency System-on-Chip (SoC) applications. The proposed circuit measures functional specifications of RF integrated circuits such as input impedance, gain, noise figure, input voltage standing wave ratio (VSWRin) and output signal-to-noise ratio (SNRout) without any expensive external equipment. The RF DFT scheme is based on developed theoretical expressions that produce the actual RF device specifications by output DC voltages from the DFT chip. The proposed DFT showed deviation of less than 2% as compared to expensive external equipment measurement. It is expected that this circuit can save marginally failing chips in the production testing as well as in the RF system; hence, saving tremendous amount of revenue for unnecessary device replacements.

Design and Implementation of Digital Electrical Impedance Tomography System (디지털 임피던스 영상 시스템의 설계 및 구현)

  • 오동인;백상민;이재상;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.269-275
    • /
    • 2004
  • Different biological tissues have different values of electrical resistivity. In EIT (electrical impedance tomography), we try to provide cross-sectional images of a resistivity distribution inside an electrically conducting subject such as the human body mainly for functional imaging. However, it is well known that the image reconstruction problem in EIT is ill-posed and the quality of a reconstructed image highly depends on the measurement error. This requires us to develop a high-performance EIT system. In this paper, we describe the development of a 16-channel digital EIT system including a single constant current source, 16 voltmeters, main controller, and PC. The system was designed and implemented using the FPGA-based digital technology. The current source injects 50KHz sinusoidal current with the THD (total harmonic distortion) of 0.0029% and amplitude stability of 0.022%. The single current source and switching circuit reduce the measurement error associated with imperfect matching of multiple current sources at the expense of a reduced data acquisition time. The digital voltmeter measuring the induced boundary voltage consists of a differential amplifier, ADC, and FPGA (field programmable gate array). The digital phase-sensitive demodulation technique was implemented in the voltmeter to maximize the SNR (signal-to-noise ratio). Experimental results of 16-channel digital voltmeters showed the SNR of 90dB. We used the developed EIT system to reconstruct resistivity images of a saline phantom containing banana objects. Based on the results, we suggest future improvements for a 64-channel muff-frequency EIT system for three-dimensional dynamic imaging of bio-impedance distributions inside the human body.