• Title/Summary/Keyword: impedance ratio

Search Result 571, Processing Time 0.03 seconds

A Study on an Impedance Matching Technique for Rail Power Line Communication (레일 전력선통신을 위한 임피던스 정합방안 연구)

  • Seo, Ill-Kwon;Ahn, Seung-Ho;Kim, Chul-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.202-207
    • /
    • 2016
  • An auxiliary real-time train communications system among drivers, train-traffic controllers and field workers is necessary to share hazard information (i.e. rockfall detection, track maintenance) in low visibility zones (long tunnels and steep curved track). To develop the appropriate communication system, this paper proposes a new way of power line communication using the rail track (Rail - PLC), which has little noise and distortion of attenuation. Therefore, it is important to measure the impedance of the rail and to apply an impedance matching technique to increase the transmission characteristic of the Rail - PLC. This study would evaluate the reflection and the transmission characteristics of the rail using a network analyzer and an impedance matching transformer. The suitable impedance matching ratio was 1:3.28 from the result of back-to-back testing. The results confirmed that the transformer can improve the performance of the transmission signal in Rail - PLC using an impedance matching technique.

Ion Conduction Properties of PVDF based Polymer Electrolyte as a function of a Mixed Ratio (PVDF계 고분자 전해질의 혼합비에 따른 이온 전도 특성)

  • 김종욱;송희웅;구할본;이경섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.121-124
    • /
    • 1998
  • The purpose of this study is to research and develop solid polymer electrolyte(SPE) for Li secondary battery. This paper describes temperature dependence of conductivity, impedance spectroscopy, electrochemical properties of PVDF electrolytes as a function of a mixed ratio. Polyvinylidene(PVDF) based polymer electrolyte films were prepared by thermal gellification method of preweighed PVDF, plasticizer and Li salt. The conductivity of PVDF electrolytes was 10$\^$-3/S/cm. 25PVDFPC$\_$10/EC$\_$10/LiClO$_4$ electrolyte shows the better conductivity of the others. 25PVDFPC$\_$10/EC$\_$10/LiClO$_4$electrolyte remains stable up to 4.7V vs. Li/Li$\^$+/. Steady state current method and ac impedance used for the determination of transference numbers in PVDFD electrolyte film. The transference number of 25PVDFPC$\_$10/EC$\_$10/LiClO$_4$electrolyte is 0.58.

  • PDF

Dual-band, dual circularly polarized stacked microstrip antenna (이중대역 이중 원형편파 적층형 마이크로스트립 안테나)

  • Chun, Jae-Bong;Oh, Kyung-Jin;Choi, Jae-Hoon
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.418-422
    • /
    • 2003
  • In this paper a dual-band circularly polarized stacked microstrip antenna for Global Positioning System (GPS) service and Digital Multimedia Broadcasting (DMB) service is designed. By stacking two different corner-truncated square microstrip patches, dual-band, dual polarization characteristic is obtained. Experimental results show impedance bandwidth of 60 MHz (3.8%) and axial ratio bandwidth of 6 MHz (0.4%) in GPS and impedance bandwidth of 126 MHz (4.7%) and axial ratio bandwidth of 30MHz (1.1%) in DMB.

  • PDF

The Eddy Current Method to Measure the Transformation Ratio in Metals (와전류 시험에 의한 금속의 변태율 측정에 관한 연구)

  • Wee, Sang-Bong;Han, Min-Koo;Paek, KI-Nam
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.5
    • /
    • pp.348-354
    • /
    • 1989
  • The metallurgical transformation ratios of metals have been evaluated by the eddy current method. Eddy current probes have been designed and applied to various standard samples. The equivalent impedance estimated from the eddy current measurement is closely related to the variation of transformation ratios in metals. It has been found that the variation of the impedance is relatively large in the samples where the transformation ratios of the samples are small. Both reactance and resistance increase when the transformation ratio is large. Sensitivities of eddy current test is increased with increasing frequencies and by inserting ferrite core the solenoid eddy probe. Our results have shown the implementation of eddy current measurement to the one-line nondestructive testing of metals.

  • PDF

Development of Standard Capacitors with Serial/Parallel Connection Structure for Expanding National Standard Traceability of Capacitance Standard Field (전기용량 국가표준 소급범위 확장을 위한 직/병렬 연결구조의 전기용량 표준기 개발)

  • Kim Han-Jun;Kang Jeon-Hong;Han Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.8
    • /
    • pp.403-407
    • /
    • 2006
  • Standard capacitors, as like as Hamon resistor standards, of series connection/parallel connection ratio $10{\mu}F/1000{\mu}F\;and\;100{\mu}F/10000{\mu}F$ were fabricated for calibration of impedance bridges or analyzers with measuring ranges up to 1 F. The calculated correction terms to the ratio of one measured value in series connection to the value in parallel connection were evaluated to be $1.92{\times}10^{-7}$. These capacitors were designed to be used not only as 100:1 capacitance standards but also as single capacitors or decade capacitors with decade values at frequencies up to 1 kHz.

Electrode of Low Impedance by Polypyrrole Addition for Supercapacitor (폴리피롤 첨가에 의한 supercapacitor용 저 임피던스 전극)

  • 김경민;장인영;강안수
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2003.11a
    • /
    • pp.343-350
    • /
    • 2003
  • The best Ppy weight ratio was 7 wt% and the optimal electrode composition ratio was 78 : 17 : 5 wt.% of (MSP-20 : BP-20 =1 : 1), (Super P : Ppy =10 : 7) and P(VdF-co-HFP). Implantation of Ppy as the conducting agents have led to superior electrochemical characteristics because of the low of internal resistance and faradaic capacitance. The result of unit cell with Ppy 7 wt% were as follows: 28.02 Fig of specific capacitance, 1.34 Ω of DC-ESR and 0.36 Ω of AC-ESR. Unit cell showed a good stability up to 200 charge-discharge cycles, retaining 82% of their original capacity at 200 cycles. From the analysis of impedance, the electrodes with Ppy 7 wt% showed low ESR, low charge transfer resistance and quick reaction rate. It was inferred that quick charge-discharge was possible. As compared with the specific capacitance (rectangular shape) of CV, it was also concluded that the specific capacitance originated from thecompound phenomena of the faradaic capacitance by oxidation and reduction of Ppy and the non-faradaic capacitance by adsorption-desorption of activated carbon.

  • PDF

The Matching Condition Design of Three Kinds of Ferrite/Rubber Composite Microwave Absorber according to the Constitutional Rate (조성비에 따른 3종 페라이트/고무 복합형 전파흡수체의 정합조건 설계)

  • 유영준;양윤석;전홍배;김철한;김한근;사공건
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.247-250
    • /
    • 1999
  • In this study, three kinds of Mn-Zn ferrite/Ni-Zn ferrite/$Ni_2Y$ ferroxplana prepared by the coprecipitation method was compounded with silicon rubber, and thereafter made ring-type specimens with various compositional ratio. The material constant of ferrite/rubber composite absorbers was obtaibed by the 2-port method. The material constants of the ferrite/rubber composite absorber with various compositional ratio of three kinds of ferrite were used to design the matching frequency and thickness with the impedance matching map. We were able to predict the matching condition from the design method.

  • PDF

Low-cost Impedance Technique for Structural Health Monitoring (임피던스 기반 저비용 구조물 건전성 모니터링 기법)

  • Lee, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.265-271
    • /
    • 2018
  • This paper presents a method for detecting damage to a structure at low cost using its impedance. The impedance technique is a typical method to detect local damage for structural health monitoring. This is a common technique for estimating damage by monitoring the electro-mechanical admittance signal of the structure. To apply this technique, an expensive impedance analyzer is generally used. On the other hand, it is necessary to develop a low-cost variant to effectively disseminate the technique. In this study, a method based on the transfer impedance using a function generator and digital multimeter, which are generally used in the laboratory instead of an impedance analyzer, was developed. That is, this technique estimates the damage by comparing the damage index using the amplitude ratio of the output voltage measured in the healthy and damaged state. A transfer impedance test was carried out on a steel specimen. By comparing the damage index, the presence of damage could be assessed reasonably. This study is a basic investigation of an impedance-based low-cost damage detection method that can be used effectively for structural health monitoring if supplemented with future research to estimate the damage location and severity.

Design of A Narrow Bandpass Filter with Wideband Harmonic Suppression Using Hairpin Step Impedance Resonators (광대역의 고조파 억제가 가능한 헤어핀 SIR을 사용한 협대역 통과 여파기 설계)

  • Park, Ju-Seong;Mohyuddin, Wahab;Choi, Hyun-Chul;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.3
    • /
    • pp.151-158
    • /
    • 2018
  • This paper proposes a new design method for narrow bandpass filters using two cascaded hairpin step impedance resonators (SIRs) with wideband harmonic suppression. The proposed bandpass filter utilizes a suspended strip line (SSL) to maximize the characteristic impedance ratio, thereby maximizing the harmonic suppression bandwidth. As an example of the proposed design method, the SSL bandpass filter with a center frequency of $f_0=1.4GHz$ and fractional bandwidth of 5 % was implemented, and proved to suppress harmonics up to $7.5f_0$ with a passband insertion loss of approximately -0.9 dB. This result implies that the proposed SSL narrow bandpass filter (NBPF) can suppress the harmonic bandwidth more than two times as compared with the filter design on a microstrip line (MSL).

Sound absorption of micro-perforated elastic plates in a cylindrical impedance tube (원통형 임피던스 튜브 내 미세천공 탄성 판의 흡음)

  • Kim, Hyun-Sil;Kim, Bong-Ki;Kim, Sang-Ryul;Lee, Seong-Hyun;Ma, Pyung-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.4
    • /
    • pp.181-187
    • /
    • 2018
  • In this paper, sound absorption of micro-perforated elastic plates installed in an impedance tube of a circular cross-section is discussed using an analytic method. Vibration of the plates and sound pressure fields inside the duct are expressed in terms of an infinite series of modal functions, where modal functions in the radial direction is given in terms of the Bessel functions. Under the plane wave assumption, a low frequency approximation is derived by including the first few plate modes, and the sound absorption coefficient is given in terms of an equivalent impedance of a single surface. The sound absorption coefficient using the proposed formula is in excellent agreement with the result by the FEM (Finite Element Method), and shows dips and peaks at the natural frequencies of the plate. When the perforation ratio is very small, the sound absorption coefficient is dominated by the vibration effect. However, when the perforation ratio reaches a certain value, the sound absorption is mainly governed by the rigid MPP (Micro-Perforated Plate), while the vibration effect becomes very small.