• Title/Summary/Keyword: impedance control

Search Result 786, Processing Time 0.027 seconds

Supercapacitive Properties of Co-Ni Mixed Oxide Electrode Adopting the Nickel Foam as a Current Collector

  • Cho, Hyeon Woo;Nam, Ji Hyun;Park, Jeong Ho;Kim, Kwang Man;Ko, Jang Myoun
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.12
    • /
    • pp.3993-3997
    • /
    • 2012
  • Three-dimensional porous nickel foam was used as a current collector to prepare a Co-Ni oxide/Ni foam electrode for a supercapacitor. The synthesized Co-Ni oxide was proven to consist of mixed oxide phases of $Co_3O_4$ and NiO. The Co-Ni oxide/Ni foam electrode prepared was characterized by morphological observation, crystalline property analysis, cyclic voltammetry, and impedance spectroscopy. Cyclic voltammetry for the electrode showed high specific capacitances, such as 936 F $g^{-1}$ at 5 mV $s^{-1}$ and 566 F $g^{-1}$ at 200 mV $s^{-1}$, and a comparatively good cycle performance. These improved results were mainly due to the dimensional stability of the nickel foam and its high electrical contact between the electrode material and the current collector substrate.

Corrosion in Oil well Stimulation Processes Caused by Different Chelating Agents Based on EDTA Compounds

  • Calderon, J.A.;Vasquez, F.A.;Arbelaez, L.;Carreno, J.A.
    • Corrosion Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.59-63
    • /
    • 2017
  • Chelating solutions can be damaged by strong acids during oil production. To design effective corrosion inhibitors and other alternatives for corrosion control, it is important to understand not only the behavior of the system under operating condition but also the kinetics of electrochemical reactions during the corrosion process. In this study, the electrochemical behaviors of P-110 steel in aqueous fluids based on ethylenediaminetetraacetic acid (EDTA) compounds under various temperatures and hydrodynamic regime conditions were assessed. Electrochemical measurements were conducted using rotating disc electrodes manufactured. Electrolytes were prepared using aqueous compounds of EDTA like diammonium salt, disodium salt, and tetrasodium salt. Potentiodynamic polarization, electrochemical impedance, and mass loss tests were performed in order to assess the corrosion kinetic in electrolytes. Hydrodynamic effects were observed only in the cathodic polarization curve. This proves that hydrodynamic regime plays an important role in the corrosion of steel mainly in disodium and diammonium EDTA solutions. Two cathodic reactions controlled the corrosion process. However, oxygen level and pH of the electrolyte played the most important role in metal corrosion. Corrosion rates in those fluids were decreased drastically when oxygen concentration was reduced.

Analysis of Obeisty Degree and Comparision of Weight Control Program among Sasang Constitution (사상체질별 비만도 분석과 체지방 감량효과의 차이에 관한 연구)

  • Shin, Seung-Uoo;Kim, Kil-Soo;Moon, Jin-Seok;Yoon, Yoo-Sik;Ryu, Su-Min
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.5 no.1
    • /
    • pp.21-29
    • /
    • 2005
  • Objectives : This study was carried out to evaluate the difference of body mass index(BMI) distribution and the difference of effect of weight reduction program among Sasang constitution. Methods : Sasang constitution was differentiated by QSCC II of 875 cases. Body composition was analysed by bioelectrical impedance analysis(Inbody 3.0, Biospace, Seoul, Korea) in before and after treatment to evaluate the effect among Sasang constitution. The weight reduction program including very low calorie diet, electrical acupuncture and herbal medicine was treated to all cases equally during 1 month. Results and Conclusions : The group of Taeum was more obese and less reducted in body fat mass and % body fat in tools of percent rates of the changes than other type of Sasang constitution. In conclusion, the group of Taeum is more easy to become obese and more difficult to treat obesity

  • PDF

Cell Balance of Secondary Battery by Using The Majority FET (다수의 FET를 이용한 2차 전지의 셀 밸런스에 관한 연구)

  • Lim, Geun-Wook;Cho, Hyun-Chan;Kim, Jong-Won;Kim, Kwang-Sun;Lee, Jung-Su;Yoo, Sang-Gil;Kang, Hee-Sun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.2
    • /
    • pp.19-22
    • /
    • 2008
  • In this paper, the cell balance of secondary battery using a large number of MOSFETs is discussed. We can balance the cells by controlling battery charging current with help of MOSFETs. If the cells are not balanced, we can not use the whole energy of the battery while charging and discharging, therefore, the energy efficiency is decreased. To increase the energy efficiency, we propose the MOSFET control algorithm which will perform cell balancing by controlling the charging current.

  • PDF

Injury and inflammation detection by the application of microcurrent through the skin

  • Hui, Timothy;Petrofsky, Jerrold
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • Objective: To determine the efficacy and reliability of measuring direct current microcurrent applied through the skin to determine injury in the underlying tissues. Design: Case control study. Methods: First, microcurrent was measured as decreased blood flow induced hypoxia in healthy subjects. Next, reliability was assessed by measuring over ten days with set variations in pressure and distance between the electrodes. Finally, measurements over sprained ankle were compared to measurements over comparable uninjured areas on the same injured subject. Results: For the blood flow test phase, microcurrent significantly decreased an average of 17% after 5 minutes (p<0.05), remained decreased for 30 seconds, and returned to non-occlusive levels after 2 minutes of normal circulation. The results indicate that the microcurrent decrease was not due to blood flow, and most likely from hypoxic cellular damage. For the reliability phase, the coefficients of variation averaged 10.3% for the shoulder, 14.8% for the low back, and 29.1% for the knee. Changing distance 2.5 cm between the electrodes resulted in insignificant changes. Changes in pressure had some significant effect after an increase in force of 2.6 N, affirming the need for consistent pressure for measurement. For the injury test phase, a significant 69% decrease occurred comparing injured areas to the same area on the uninjured side, and a significant 74% occurred comparing injured and non-injured areas on the same limb. Conclusions: Microcurrent through the skin shows promise as an objective method of assessing a soft tissue injury by detecting damage likely due to hypoxia.

  • PDF

The Study on the Mutual Characteristics Between Transmitting Efficiency of Pulse Energy and Wall Plug Consumed Power of Non-Thermal Plasma (저온 플라즈마의 펄스에너지 전송효율과 Wall Plug 소비전력과의 상호 특성에 관한 연구)

  • Jeong, Jong-Han;Jeong, Hyeon-Ju;Kim, Hwi-Yeong;Jeong, Yong-Ho;Song, Geum-Yeong;Kim, Geun-Yong;Kim, Hui-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.10
    • /
    • pp.506-510
    • /
    • 2002
  • In this paper, we study on the mutual characteristics between transmitting efficiency of pulse energy and wall plug consumed power of non-thermal Plasma for removing environmental pollutive gas of coal plant. To obtain high pulse energy of our system, we used MPC(magnetic pulse compressor) of power switch and tested their characteristics by adjusting electrode length of reactor and charging voltage in capacitor. As a result, we obtained consumed power of wall plug and a compressed pulse of voltage 110kV, rising time 500ns. Impedance of load on increasing electrode length was decreased, but electrical efficiency was increased. These results indicate we can control critical voltage of pulse corona and electrical efficiency of economic cost in power plant.

A Study on Pulse Power Suppuy for Microwave Oven Using HVC Embedded High Frequency Transformer (HVC 내장형 고주파변압기를 이용한 Microwave Oven용 펄스전원장치에 관한 연구)

  • Park K.H.;Cho J.S.;Jung B.H.;Mok H.S.;Park H.B.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.584-588
    • /
    • 2001
  • A conventional power supply to drive a microwave oven has ferro-resonant transformer and high voltage Capacitor(HVC). Though it is simple, transformer is bulky, heavy and has low-efficiency. To improve this defect a high frequency inverter type power supply has been investigated and developed in recent years. But, because of additional control circuit and switching device, inverter-type power supply is more expensive than conventional one. In this study, A new pulse power supply for Microwave Oven using novel HVC embedded high frequency transformer is proposed for down-sizing, cost reduction, and efficiency emprovement of Inverter type power supply. Also, equivalent circuit model is derived by impedance measurements. And the operation of proposed pulse power supply is verified by simulations and experimental results.

  • PDF

Effective Installations Technique of Grounding Conductors for Metal Oxide Surge Arrestors (배전피뢰기용 접지도선의 효과적인 설치기법)

  • Lee, Bok-Hui;Gang, Seong-Man;Yu, In-Seon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.6
    • /
    • pp.253-259
    • /
    • 2002
  • This paper deals with the effects of grounding conductors for metal oxide surge arresters. When surge arresters are improperly installed, the results can cause costly damage of electrical equipments. In particular, the route of surge arrester connection is very important because bends and links of leads increase the impedances to lightning surges and tend to nullify the effectiveness of a grounding conductor. Therefore, there is a need to know how effective installation of lightning surge arresters is made in order to control voltage and to absorb energy at high lightning currents. The effectiveness of a grounding conductor and 18 [㎸] metal oxide distribution line arresters was experimentally investigated under the lightning and oscillatory impulse voltages. Thus, the results are as follows; (1) The induced voltage of a grounding conductor is drastically not affected by length of a connecting line, but it is very sensitive to types of grounding conductor. (2) The coaxial cable having a low characteristic impedance is suitable as a grounding conductor. (3) It is also clear from these results that bonding the metal raceway enclosing the grounding conductor to the grounding electrode is very effective because of skin effect. (4) The induced voltages of grounding conductors for the oscillatory impulse voltages are approximately twice as large as those for the lightning impulse voltages.

Programmable Smart Charger Compatible to Various Load Conditions (다양한 부하조건에 호환 가능한 프로그래머블 스마트 충전기)

  • Jo, Kang-Ta;Keum, Moon-Hwan;Han, Sang-Kyoo;Oh, Dong-Sung;Sakong, Suk-Chin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.357-363
    • /
    • 2014
  • A programmable smart charger compatible to various load conditions is proposed in this paper. Since the proposed smart charger is compatible to various mobile devices having different rated voltage and power, it is convenient for carrying and easy to standardize many kinds of battery chargers. Moreover, since it uses the input impedance and built-in PMIC (Power management IC) of the load system to recognize the connection state and specifications of load system, hardware changes of load system is not only hardly necessary but it also features no addition communication cable and easy implementation. To confirm the validity of the proposed charger, the theoretical analysis and experiment results from a prototype compatible to three load conditions 5V/1A, 5V/2A and 12V/1A are provided.

Islanding Detection for a Micro-Grid based on the Instantaneous Active and Reactive Powers in the Time Domain (시간영역에서 순시 유효/무효전력을 이용한 마이크로그리드의 단독운전 판단)

  • Lee, Young-Gui;Kim, Yeon-Hee;Zheng, Tai-Ying;Kim, Tae-Hyun;Kang, Yong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.22-27
    • /
    • 2012
  • Correct and fast detection of a micro-grid (MG) islanding is essential to the MG since operation, control and protection of the MG depend on an operating mode i.e., an interconnected mode or an islanding mode. When islanding occurs, the frequency of the point of common coupling (PCC) is not the nominal frequency during the transient state owing to the frequency rise or drop of generators in the MG. Thus, the active and reactive power calculated by the frequency domain based method such as Fourier Transform might contain some errors. This paper proposes an islanding detection algorithm for the MG based on the instantaneous active and reactive powers delivered to the dedicated line in the time domain. During the islanding mode, the instantaneous active and reactive powers delivered to the dedicated line are constants, which depend on the voltage of the PCC and the impedance of the dedicated line. In this paper, the instantaneous active and reactive powers are calculated in the time domain and used to detect islanding. The performance of the proposed algorithm is verified under various scenarios including islanding conditions, fault conditions and load variation using the PSCAD/EMTDC simulator. The results indicate that the algorithm successfully detects islanding for the MG.