• 제목/요약/키워드: impedance control

검색결과 786건 처리시간 0.029초

Ultra-small Marker Beacon Antenna with a Wide Frequency Tuneable Capacitive Plate

  • Park, Ju-Derk;Choi, Byeong-Cheol;Kim, Nam;Jung, Young-Bae
    • ETRI Journal
    • /
    • 제38권5호
    • /
    • pp.879-884
    • /
    • 2016
  • In this paper, an ultra-small marker beacon antenna operated in the VHF-band is proposed. This antenna has a modified linear IFA structure with a lumped capacitor and a capacitive plate for frequency tuning and impedance matching. The capacitive plate is directly connected to the end of a linear radiator and is separated from the antenna ground by 1 mm. The main operating frequency is mainly controlled by the size and dielectric constant of the capacitive plate. The lumped capacitor is useful for fine frequency tuning. Using the proposed structure, an ultra-small marker beacon antenna can be realized with a length of 0.04 ${\lambda}_0$.

Three-poles Touch-type Corrosion Sensor for Edge Detection of Initial State of Iron Rust

  • Yonemoto, Naruto;Shida, Katsunori
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.308-311
    • /
    • 1998
  • Some nondestructive diagnostic methods including various types of corrosion sensors have been investigated. Under these conditions, a new structure of sensor that has a pair of electrode and magneto-supply was proposed. In order to detect the edge of the iron rust part, three-poles touch-type corrosion sensor is now proposed. The iron rust pattern where the sensor touches is estimated by means of the impedance of the sensor, and the edge of the iron rust is recognized by comparing the three measured impedances. As the result, our proposed sensor is useful to detect the initial state of iron rust.

  • PDF

부임피던스 회로를 이용한 두께 진동 모드 압전 진동자의 특성제어 (Characteristics Control of Thickness Vibration Mode Piezoelectric Vibrator Using Negative Impedance Converter Circuit)

  • 황성필;김무준;하강열
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2002년도 하계학술발표대회 논문집 제21권 1호
    • /
    • pp.369-372
    • /
    • 2002
  • 전극분할 된 횡진동 모드 압전 진동자에 NIC 회로를 적용한 특성제어 방법을 두께 진동 모드 압전 진동자에 적용하여 그 가능성을 확인해 보았다. 동일한 특성을 가진 두 개의 두께 진동 모드 압전 진동자를 분극방향이 서로 마주보게 제작한 다음, NIC 회로를 적용하여 그 실험결과를 PSpice 모델을 이용한 시뮬레이션과 비교하였다. 그 결과 NIC 회로의 저항 $R-s$,의 변화에 따라 두께 진동 모드 압전 진동자의 품질계수는 제어되었으며, NIC 회로를 적용하지 않은 경우보다 품질계수가 약 18.9배 정도 향상되었다.

  • PDF

정방형 트랜스듀서의 방사임피던스에 의한 특성 변화 (The Characteristics Variation of a Square Transducer as the Radiation Impedance -)

  • 이기욱;김무준;하강열;김천덕
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2000년도 학술발표대회 논문집 제19권 2호
    • /
    • pp.265-268
    • /
    • 2000
  • 트랜스듀서의 삽입손실과 임펄스 응답특성 등을 정확히 해석하기 위해서는 대상 주파수 대역에 대한 특성을 알아야한다. 방사임피던스는 주파수의 함수이기 때문에 이러한 특성을 결정하는 중요한 요소이다. 따라서 본 연구에서는 정방형 방사면을 가지는 트랜스듀서 이용하여, 무한배플에서의 방사임피던스를 고려한 삽입손실을 이론적으로 계산하고 무한배플로 근사할 수 있는 모델을 제작하고, 이를 실험으로 확인한 결과 좋은 일치를 보이고 있어 본 연구에서 제안한 해석법의 타당성을 확인하였다.

  • PDF

구형 배플을 가진 피스톤 음원간의 상호 방사임피던스 계산 (Calculation of Mutual Radiation Impedance for Piston Sources with Spherical Type Baffle)

  • 박순종;김무준;김천덕
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2002년도 하계학술발표대회 논문집 제21권 1호
    • /
    • pp.439-442
    • /
    • 2002
  • 구형 배플을 가진 피스톤 음원에 대한 방사임피던스 특성을 유한요소법과 하이브리드형 무한요소법을 사용하여 수치해석하였다. 강체 구형 배플에 있어서 피스톤 음원의 방사면 크기에 따른 자기방사임피던스 변화와 피스톤 음원간의 상호방사임피던스 변화를 고찰하였다. 방사면의 크기에 따라 자기방사임피던스 변화 및 음원간의 상호방사임피던스 변화를 검토한 결과 알려진 해석해와 일치하였다. 또한, 비강체 구형 배플의 특성 임피던스 변화에 따른 자기방사임피던스 및 음원간의 상호방사임피던스 특성 변화를 고찰하였다.

  • PDF

과도현상 해석을 위한 EAFs 부하 무델의 개발 (An Electric Arc Furnaces Load Model for Transient Analysis)

  • 장길수;;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권3호
    • /
    • pp.197-202
    • /
    • 1999
  • Electric arc furnaces (EAFs) use bulk electrical energy to create heat in metal refining industries. The electric arc process is a main cause of the degradation of the electric power quality such as voltage flicker due to the interaction of the high demand currents of the load with the supply system impedance. The stochastic models have described the aperiodic physical phenomena of EAFs. An alternative approach is to include deterministic chaos in the characterization of the arc currents. In this parer, a chaotic approach to such modeling is described and justified. At the same time, a DLL(Dynamic Link Library) module, which is a FORTRAN interface with TACS (Transient Analysis of Control Systems), is developed to implement the chaotic load model in the Electromagnetic Transients Program (EMTP). The details of the module and the results of tests performed on the module to verify the model and to illustrate its capabilities are presented in this paper.

  • PDF

Over Current Protection Schemes for Active Filters with Series Compensators

  • Lee, Woo-Cheol;Lee, Taeck-Kie
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권3호
    • /
    • pp.134-145
    • /
    • 2004
  • This paper presents and analyses protection schemes for a series active compensator, which consists of a Unified Power Quality Conditioner (UPQC) or a hybrid active power filter. The proposed series active compensator operates as a high impedance "k(D)" for the fundamental components of the power frequency during over current conditions in the distribution system. Two control strategies are proposed in this paper. The first strategy detects the fundamental source current using the p-q theory. The second strategy detects the fundamental component of the load current in the Synchronous Reference Frame (SRF). When over currents occur in the power distribution system momentarily, the proposed schemes protect the series active compensator without the need for additional protection circuits, and achieves excellent transient response. The validity of the proposed protection schemes is investigated through simulation and compared with experimental results using a hybrid active power filter systems.

Steady-State Harmonic Domain Matrix-Based Modeling of Four-Quadrant EMU Line Converter

  • Wang, Hui;Wu, Mingli;Agelidis, Vassilios G.;Song, Kejian
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.572-579
    • /
    • 2014
  • As a non-linear time variant system, the four-quadrant line converter of an electric multiple unit (EMU) was expressed by linear time periodic functions near an operating point and modeled by a steady-state harmonic domain matrix. The components were then combined according to the circuit connection and relations of the feedback control loops to form a complete converter model. The proposed modeling method allows the study of the amplitude of harmonic impedances to explore harmonic coupling. Moreover, the proposed method helps provide a better design for the converter controllers, as well as solves the problem in coordination operation between the EMUs and the AC supply. On-site data from an actual $CRH_2$ high-speed train were used to validate the modeling principles presented in the paper.

4분법을 이용한 전압 클램프 VCO의 설계에 관한 연구 (A Study on the Design of Voltage Clamp VCO Using Quadrature Phase)

  • 서일원;최우범;정석민;성만열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3184-3186
    • /
    • 1999
  • In this paper, a new structure of fully differential delay cell VCO using quadrature phase for low phase noise and high speed operation is suggested. It is realized by inserting voltage clamp circuit into input pairs of delay cells that include three-control current source having high output impedance. In this reason. this newly designed delay cell for VCO has the low power supply sensitivity so that the phase noise can be reduced. The whole characteristics of VCO were simulated by using HSPICE and SABER. Simulation results show that the phase noise of new VCO is quite small compared with conventional fully differential delay cell VCO and ring oscillator type VCO. It is also very beneficial to low power supply design because of wide tuning range.

  • PDF

통합 전력품질 제어기의 과전류 보호방법에 관한 연구 (A Study on Over Current Protection Method of Unified Power Quality Conditioners)

  • 채범석;이우철;이택기;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.543-547
    • /
    • 2001
  • A protection scheme for Unified Power Quality Conditioner (UPQC) is presented and analyzed in this paper. The proposed UPQC has the series active power filter operated as a high impedance k($\Omega$) to the fundamentals when short-circuit faults occur in the power distribution system, and three control strategies are proposed in this paper. The first is the method by detecting the fundamental source current through the p-q theory, the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame(SRF) and the third is the method by detecting the input voltage. When the short-circuit fault occur in the power distribution system, the proposed scheme protects the UPQC without additional protection circuits. The validity of proposed protection scheme is investigated through simulation results.

  • PDF