• 제목/요약/키워드: impedance change

검색결과 451건 처리시간 0.028초

소자 구조에 따른 형광 OLED의 Impedance 특성 (Impedance Characteristics of Fluorescent OLED with Device Structure)

  • 공도훈;주성후
    • 한국재료학회지
    • /
    • 제28권1호
    • /
    • pp.18-23
    • /
    • 2018
  • To study the impedance characteristics of a fluorescent OLED according to the device structure, we fabricated Device 1 using ITO / NPB / $Alq_3$ / Liq / Al, Device 2 using ITO / 2-TNATA / NPB / $Alq_3$ / Liq / Al, and Device 3 using ITO / 2-TNATA / NPB / SH-1:BD / $Alq_3$ / Liq / Al. The current density and luminance decreased with an increasing number of layers of the organic thin films in the order of Device 1, 2, 3, whereas the current efficiency increased. From the Cole-Cole plot at a driving voltage of 6 V, the maximum impedance values of Devices 1, 2, and 3 were respectively 51, 108, and $160{\Omega}$ just after device fabrication. An increase in the impedance maximum value is a phenomenon caused by the charge mobility and the resistance between interfaces. With the elapse of time after the device fabrication, the shape of the Cole-Cole plot changed to a form similar to 0 or a lower voltage due to the degradation of the device. As a result, we were able to see that an impedance change in an OLED reflects the characteristics of the degradation and the layer.

생체 임픽던스 측정에 의한 상지 운동 감지 시스템 (A Human Arm Movement Detection System Using Electrical Bioimpedance Measurement)

  • 김종찬;김수찬;남기창;박민용;김경환;김덕원
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권8호
    • /
    • pp.374-379
    • /
    • 2002
  • In this study, we developed a new human arm movement detection system using electrical bio-impedance method with several skin-electrodes. The correlation coefficients of the joint angle and the impedance change from human arm movement was obtained using a goniometer and impedance measurement system developed in this study. The correlation coefficients of the wrist and the elbow movements were 0.94 and -0.99, respectively. This system was applied to control a robotic arm by converting the measured impedance to joint angle to confirm the validity of the proposed system. In conclusion, we confirmed that this system can control the robotic arm according to arm movement without any limitation of movement. This system showed possibility that upper arm movement could be easily measured by impedance measurement system with a few skin-electrodes.

Monitoring of Degradation Process of Commercial ME Tapes under High Humidity Environment by AC Impedance Techniques

  • Take, Seisho;Shimanuki, Akiko;Itoi, Yasuhiko;Okuyama, Masaru
    • Corrosion Science and Technology
    • /
    • 제3권5호
    • /
    • pp.194-197
    • /
    • 2004
  • The corrosion resistance of several kind of ME (Metal Evaporated) tape has been investigated both in mild sulfuric acid solution and NaCl solution by electrochemical impedance spectroscopy. It was found that the degradation of ME tapes was accelerated with increasing the concentration of sulfuric acid. There was no significant change in corrosion resistance when the concentration of NaCl was under 3.5 wt%. However, the impedance value decreased when the concentration of NaCl was up to 10 wt%. The degradation of backside of ME tapes was also investigated by AC impedance measurements. The results showed that the impedance behavior of backside plastic film changed with the concentration of sulfuric acid even at the beginning of immersion, implying the changing of the permeability for the backside of ME tapes. It was also found that the corrosion resistance of DVC (Digital Video Cassette) ME tape was better that that of Hi-8mm ME tapes in sulfuric acid solutions. Also, the backside of DVC ME tape showed better water resistance than that of Hi8 ME tapes.

전류 주입 자기공명영상에 온도 변화가 미치는 영향 (Effects of Temperature Change on the Current Injected MRI)

  • 이수열;강현수;우응제;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권3호
    • /
    • pp.303-309
    • /
    • 2001
  • It is well known that the electrical impedance of biological tissues is very sensitive to their temperature. In this paper, we have analyzed the effects of temperature change on the phase of magnetic resonance images obtained with external current injection. It has been found that the local phase in the current injected magnetic resonance image can be changed noticeably when local temperature change appears at a part of the tissue. At the experiments with a 0.3 Tesla MRI system, we observed the local phase changes at the phantom images when the phantom temperature was varied between 25 -45$^{\circ}C$. We think that the current injection MRI technique can be used for in-vivo monitoring of the temperature inside biiological tissues if the relation between the local temperature and phase can be quantified.

  • PDF

압전소자를 이용한 TRUSS 구조물의 볼트 결합 토크 추정에 관한 연구 (Study of Bolt Coupling Torque Conclusion of TRUSS Structure Using PZT Patches)

  • 한수현;김병진;홍동표
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.612-615
    • /
    • 2005
  • This studies presented truss frame which use aluminum beam by damage model. Truss frame which each joint part is contracted by bolt contracted conclusion of each bolt by 3.0 N/m. And measured impedance change that appear making bolt 0.5 N/m on damage condition 8 times. Compares impedance change of 5 segments that was set by measurement area and displayed result. To measure torque change of bolt, other damage model did not apply.

  • PDF

Impedance Spectroscopy Analysis of Hydration in Ordinary Portland Cements Involving Chemical Mechanical Planarization Slurry

  • Hwang, Jin-Ha
    • 한국세라믹학회지
    • /
    • 제49권3호
    • /
    • pp.260-265
    • /
    • 2012
  • Impedance spectroscopy was used to monitor the hydration in the electrical/dielectric behaviors of chemical mechanical planarization (CMP)-blended cement mixtures. The electrical responses were analyzed using their equivalent circuit models, leading to the separation of the bulk and electrode based responses. The role of the CMP slurry was monitored as a function of the relative compositions of the CMP-blended cements, i.e. water, CMP slurry, and ordinary Portland cement. The presence of $Al_2O_3$ nanocrystals in the CMP slurries appeared to accelerate the hydration process, along with a more tortuous microstructure in the hydration, with enhanced hydration products. The frequency-dependent impedance spectroscopy was proven to be a highly efficient approach for evaluating the electrical/dielectric monitoring of the change in the pore structure evolution that occurs in CMP-blended cements.

필터타입으로 구성한 자기임피던스센서의 특성 (Properties of Filter type Magnetoimpedance Sensor)

  • 사공건;김영학;신광호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.337-340
    • /
    • 2004
  • To develop the highly sensitive Magneto-Impedance sensor, the amorphous ribbon was micro-processed to meander type sensor pattern and the filter circuit was constructed with this pattern. Its external magnetic field dependence of impedance and the output properties of the filter circuit were investigated. The impedance of the pattern had a peak value at the magnetic field of 10 Oe and its changing ratio was about 280%. The impedance change per unit magnetic field was about 36%, in which the output with high sensitivity and linearity could be obtained. The output sensitivity was about 7%/Oe at bias field of 6 Oe..

  • PDF

교류 저전압 표준용 교류-직류 변환기의 입력임피던스 평가기술 개발 (Development of an Input Impedance Evaluation of the AC-DC Transfer Standard for Low Level AC Voltage Standard)

  • 권성원;정재갑;이상화;김문석;김한준
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.229-234
    • /
    • 2008
  • An AC-DC transfer standard(TS) is used for the AC voltage standard in the range of 2 mV to 1000 V below 1 MHz. Micro-potentiometer(${\mu}Pot$) is used to evaluate the ac-dc transfer difference(ADD) of the TS below 200 mV range. The ADD of the TS were changed by the loading effect caused from the input impedance change of the TS depend on frequency. An input impedance evaluation technique of the TS using ${\mu}Pot$ has been developed.

임피던스 방법을 이용한 심장 기능의 측정 (Measurement of Cardiac Function using Impedance Technique)

  • 김정얼;김덕원;김원기;박상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.727-730
    • /
    • 1988
  • In this paper, cardiac parameters and relationship between stroke volume and impedance change were explained, and an impedance cardiograph was designed and constructed, and its accuracy was verified by experiment. Useful cardiac parameters such as stroke volume and contractility of cardiac muscle were measured noninvasively. The reproducibility of the instrument was measured to be better(less than 10%) than that of clinical standard method such as thermodilution. Hence impedance cardiography was found to be better technique for monitoring stroke volume and contractility of patients for pre and post operation, and pharmacological studies.

  • PDF

Simulated Annealing기법을 이용한 초음파의 계면 반사 특성평가 (Evaluation of ultrasonic reflection characteristics on an interface surface using Simulated Annealing)

  • 은길수;김노유;나환선
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.395-400
    • /
    • 2002
  • Epoxy coating and sealing used in nuclear plants for the protection of radiation degrades with aging and hazardous atmosphere. In order to evaluate the degradation of the epoxy, dependence of the acoustic impedance on the change of mechanical properties has been used. Unlike metals, the surface of the epoxy coating on a concrete liner is so wavy that the acoustic impedance is difficult to measure by using the reflectivity of the ultrasound on the interface surface because of the irregular reflection and propagation from the epoxy surface. SA(simulated annealing) algorithm is applied to calculate the acoustic impedance using a reflection wave from the rough epoxy surface. The surface waviness and acoustic impedance are taken into account and determined by SA method to evaluate the state of degradation quantitatively.

  • PDF