• 제목/요약/키워드: impedance change

검색결과 451건 처리시간 0.029초

자기단 전원 임피던스 추정 기법을 사용한 병행 2회선 송전선로 고장점 표정 알고리즘 (A Fault Location Algorithm Using Adaptively Estimated Local Source Impedance for a Double-Circuit Transmission Line System)

  • 박건호;강상희;김석일;신종한
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.373-379
    • /
    • 2012
  • This paper presents a fault location algorithm based on the adaptively estimated value of the local sequence source impedance for faults on a parallel transmission line. This algorithm uses only the local voltage and current signals of a faulted circuit. The remote current signals and the zero-sequence current of the healthy adjacent circuit are calculated by using the current distribution factors together with the local terminal currents of the faulted circuit. The current distribution factors consist of local equivalent source impedance and the others such as fault distance, line impedance and remote equivalent source impedance. It means that the values of the current distribution factors can change according to the operation condition of a power system. Consequently, the accuracy of the fault location algorithm is affected by the two values of equivalent source impedances, one is local source impedance and the other is remote source impedance. Nevertheless, only the local equivalent impedance can be estimated in this paper. A series of test results using EMTP simulation data show the effectiveness of the proposed algorithm. The proposed algorithm is valid for a double-circuit transmission line system where the equivalent source impedance changes continuously.

DGS를 이용한 가변 임피던스 선로 특성에 관한 연구 (A Study on the Characteristic of Variable Impedance Line using DGS)

  • 김영주;정명섭;박준석;조홍구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권1호
    • /
    • pp.35-40
    • /
    • 2005
  • In this paper, we designed and fabricated the variable impedance line by using the DGS(Defected Ground Structure) which is useful in mounting the external lumped elements. Also we used a varactor diode as Control device stuff at the proposed variable impedance line. We are able to change the impedance of transmission line as varied the capacitance of varactor diode by adjusting DC bias. The impedance variation of the proposed DGS line is about maximum 70 Ω. We will study about the application of DAM(Direct antenna modulation) in the future work.

A New Algorithm Design for the Real-time Electrochemical Impedance Monitoring System

  • Chang, Byoung-Yong
    • Journal of Electrochemical Science and Technology
    • /
    • 제3권4호
    • /
    • pp.154-158
    • /
    • 2012
  • It is generally known that electrochemical impedance spectroscopy is a powerful technique and its real-time application has been demanded for prompt observations on instantaneous electrochemical changes. Nevertheless, long measurement time and laborious analysis procedures have hindered development of it. Solving the problems, here I report of a new algorithm design for development of a real-time electrochemical impedance monitoring system, which potentially provides a guideline in developing monitoring systems of electric vehicles batteries and other electrochemical power plants. The significant progress in this report is employment of the parallel processing protocol which connects independent sub functions to successfully operate with avoiding mutual interruptions. Therefore, all the processes required to monitor electrochemical impedance changes in realtime are properly operated. To realize the conceptual scheme, a Labview program was coded with sub functions units which conduct their processes individually and only data are transferred between them through the parallel pipelines. Finally, measured impedance spectra and analysis results are displayed, which are synchronized according to the time of change.

온도에 따른 유기발광소자의 임피던스 분석 (Impedance spectrosocpy depending on temperature in Organic Light-Emitting Diodes)

  • 안준호;정동회;장경욱;송민종;이성일;이준웅;김태완
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.543-546
    • /
    • 2004
  • Bias and frequency-dependent impedance is a technique for the investigation of complex conductivity. At low frequency, complex impedance is dominated by resistive component, and at high frequency by capacitive component. We are going to present the results of the bias and frequency-dependent complex impedance in the device structure of $ITO/Alq_3/Al$ in the temperature range between 10K and 300k. And we will show to change radius of Cole-Cole plot. It will be decrease resistance by temperature. Also equivalent electrical circuit and dielectric relaxation can be accomplished by using the complex impedance analysis.

  • PDF

볼트 연결부 모니터링을 위한 다채널 무선 임피런스 센서노트와 EMI 인터페이스의 성능 분석 (Performance evaluation of EMI interface and multi-channel wireless impedance sensor node for bolted connection monitoring)

  • 윙 칵 유이;이포영;김정태
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.36-39
    • /
    • 2011
  • In this paper, performance of EMI interface and multi-channel wireless impedance sensor node is evaluated for SHM on bolted connection. To achieve the objective, following approaches are implemented. Firstly, an interface washer is designed to monitor loosened bolt through the variation in EMI of interface washer due to change in preload in bolt. Secondly, a multi-channel wireless impedance sensor node based on Imote2 platform is designed for automated and cost-efficient impedance-based SHM on bolted connections. Finally, performance of the multi-channel wireless impedance sensor node and the interface washer are experimentally validated for a lab-scale bolted connection model. A damage monitoring method using RMSD index of EMI signatures is utilized to examine the strength of each individual bolted connection.

  • PDF

구조용 케이블의 장력 변화에 따른 정착부의 임피던스 특성에 대한 유한요소해석 (Finite Element Analysis on Impedance Parameters of Anchor Plate of Structural Cables Under Cable Force Changes)

  • ;박재형;홍동수;이주원;김정태;나원배
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2010년도 정기 학술대회
    • /
    • pp.783-786
    • /
    • 2010
  • This paper presents a finite element analysis on impedance parameters of anchor plates of structural cables under the change in cable forces. To achieve the objective, four approaches are implemented as follows: Firstly, theoretical background of electro-mechanical impedance is described. Secondly, anchor plates of structural cables are selected to experimentally examine the relationship between impedance parameters and cable force changes. Thirdly, finite element analysis is performed to verify the experimental results. Fourthly, a comparison between the experimental and numerical analysis on impedance parameters of anchor plate of structural cables under cable force changes is carried out.

  • PDF

bioimpedance 신호를 이용한 하지동작 분석 (Analysis of leg movements using bioimpedance bignal)

  • 송철규;윤대영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.940-942
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the variation of the lower leg electrical impedance. This impedance is measured by the four-electrode method. Two current electrodes are applied to the thigh and foot, and two potential electrodes are applied to the lateral aspect, medial aspect, and posterior position of lower leg. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. From such features of the lower leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level.

  • PDF

각성도 제어를 위한 평가기준의 설정 및 경고음의 효과분석 (Evaluation of the Criteria for the Control of Arousal Level and Effect of Warning Signal)

  • 김연호
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.79-86
    • /
    • 1997
  • This paper describes the development of portable arousal measurement and analysis system. Skin impedance change which responds to the change of arousal level was detected by the three elctrode constant current method and separated into two components(SIR, SIL). Relationship between Nz, IRI and arousal level was studied and criteria of arousal level control was decided by the sleep study. Measured data with and without warning signal were compared and analyzed.

  • PDF

Early Detection of Peripheral Intravenous Infiltration Using Segmental Bioelectrical Impedance: Preliminary Study

  • Kim, Jaehyung;Jeong, Ihnsook;Baik, Seungwan;Jeon, Gyerok
    • 한국멀티미디어학회논문지
    • /
    • 제20권3호
    • /
    • pp.482-490
    • /
    • 2017
  • Early detection of infiltration is one of the most important tasks of nurses to minimize skin damage due to infiltration. For subjects receiving invasive intravenous treatment, the bioelectrical impedance (impedance) were measured in the frequency range of 5 to 500 kHz using bioelectrical impedance spectroscopy (BIS). After attaching electrodes at both ends of a transparent dressing mounted on the skin in which IV solution was infused into the vein, the change in impedance was measured as a function of time and frequency before and after infiltration. The experimental results are described as follows. When IV solution was properly infused into the vein, the impedance was nearly constant over time and decreased with increasing frequency. However, when infiltration occurred, the impedance decreased significantly and thereafter gradually decreased with time. In addition, impedance decreased with time for all applied frequencies. In this study, when IV solution penetrated into the surrounding skin and subcutaneous tissue by infiltration, impedance was quantitatively analyzed for as a function of time and frequency. This suggests a method for early detection of infiltration using BIS.

토목 구조물의 PZT Impedance 기반 손상추정기법 (PZT Impedance-based Damage Detection for Civil Infrastructures)

  • S. H. Park;Y. Roh;C. B. Yun;J. H. Yi
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 봄 학술발표회 논문집
    • /
    • pp.373-380
    • /
    • 2004
  • This paper presents the feasibility of an impedance-based damage detection technique using piezoelectric (PZT) transducers for civil infrastructures such as steel bridges. The impedance-based damage detection method is based on monitoring the changes in the electrical impedance. Those changes in the electrical impedance are due to the electro-mechanical coupling property of the piezoelectric material and structure. An effective integrated structural health monitoring system must include a statistical process of damage detection that is automated and real time assessment of damage in the structure. Once measured, damage sensitive features from this impedance change can be statistically quantified for various damage cases. The results of the experimental study on three kinds of structural members show that cracks or loosened bolts/nuts near the PZT sensors may be effectively detected by monitoring the shifts of the resonant frequencies. The root mean square (RMS) deviations of impedance functions between before and after damages were also considered as a damage indicator. The subsequent statistical methods using the impedance signature of the PZT sensors were investigated.

  • PDF