• 제목/요약/키워드: immediate dental implant loading

검색결과 66건 처리시간 0.026초

완전 무치악에서 즉시 부하시와 표준 부하시 임플란트 생존율에 대한 비교 분석: 후향적 연구 (Comparative analysis of immediate functional loading and conventional loading about implant survival rate in the completely edentulous: Retrospective study)

  • 서현수;박준우;홍순민;이석련
    • 대한치과의사협회지
    • /
    • 제52권12호
    • /
    • pp.771-782
    • /
    • 2014
  • Introduction: This study researched the clinical application of immediate functional loading technique about implant survival rate in the completely edentulous and suggested our protocol about surgical & prosthetic procedure. Materials and methods: 32 consecutive patients participated in this study. A total of 242 implants were inserted. In test group, 144 implants were inserted in 19 patients with immediate functional loading with occlusal contact. In control group, 98 implants were inserted in 13 patients and conventional loading was done after 4~6 months. Result: In the immediately loaded implants group, overall cumulative survival rate was 98.6%.

The feasibility of immediately loading dental implants in edentulous jaws

  • Henningsen, Anders;Smeets, Ralf;Wahidi, Aria;Kluwe, Lan;Kornmann, Frank;Heiland, Max;Gerlach, Till
    • Journal of Periodontal and Implant Science
    • /
    • 제46권4호
    • /
    • pp.234-243
    • /
    • 2016
  • Purpose: Immediate loading of dental implants has been proved to be feasible in partially edentulous jaws. The purpose of this retrospective investigation was to assess the feasibility of immediately loading dental implants in fully edentulous jaws. Methods: A total of 24 patients aged between 53 and 89 years received a total of 154 implants in their edentulous maxillae or mandibles. Among the implants, 45 were set in fresh extracted sockets and 109 in consolidated alveolar bones. The implants were provisionally managed with chair-side made provisional resin bridges and exposed to immediate loading. Implants were followed up for 1-8 years, including radiographic imaging. Marginal bone levels were evaluated based on radiographic imaging. Results: A total of 148 out of the 154 implants survived over the follow-up period of 1 to 8 years, giving a survival rate of 96%. The time or region of the implantation, the pre-implant augmentation, and the length and diameter of the implants had no statistically significant influence on the survival or the success rate. The marginal bone level remained stable with only minimal loss of 0.3 mm after 60 months of loading. Conclusions: Within the limitations of this study, immediate loading is feasible for dental implants in edentulous jaws.

Analysis of time to failure of orthodontic mini-implants after insertion or loading

  • Jeong, Jong-Wha;Kim, Jong-Wan;Lee, Nam-Ki;Kim, Young-Kyun;Lee, Jong-Ho;Kim, Tae-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제41권5호
    • /
    • pp.240-245
    • /
    • 2015
  • Objectives: This study was performed to evaluate patterns of failure time after insertion, failure rate according to loading time after insertion, and the patterns of failure after loading. Materials and Methods: A total of 331 mini-implants were classified into the non-failure group (NFG) and failure group (FG), which was divided into failed group before loading (FGB) and failed group after loading (FGA). Orthodontic force was applied to both the NFG and FGA. Failed mini-implants after insertion, ratio of FGA to NFG according to loading time after insertion, and failed mini-implants according to failed time after loading were analyzed. Results: Percentages of failed mini-implants after insertion were 15.79%, 36.84%, 12.28%, and 10.53% at 4, 8, 12, and 16 weeks, respectively. Mini-implant failure demonstrated a peak from 4 to 5 weeks after insertion. The failure rates according to loading time after insertion were 13.56%, 8.97%, 11.32%, and 5.00% at 4, 8, 12, and 16 weeks, respectively. Percentages of failed mini-implants after loading were 13.79%, 24.14%, 20.69%, and 6.9% at 4, 8, 12, and 16 weeks, respectively. Conclusion: Mini-implant stability is typically acquired 12 to 16 weeks after insertion, and immediate loading can cause failure of the mini-implant. Failure after loading was observed during the first 12 weeks.

즉시하중시 상악 전치부에 식립된 임플란트 길이 변화에 따른 응력 분포의 삼차원 유한요소 연구 (Effect of Implant Length on the Immediate Loading at the Anterior Maxilla)

  • 이준석;김명주;권호범;임영준
    • 구강회복응용과학지
    • /
    • 제25권3호
    • /
    • pp.255-265
    • /
    • 2009
  • 즉시 하중에 대한 관심과 시도가 증가되고 있지만, 명확한 술식이 정립되어 있지는 않다. 본 연구에서는 상악 전치부 임플란트에서 즉시 하중시에 골과 임플란트에 나타나는 응력분포 양상을 3차원 유한요소법을 이용하여 알아보고자 하였다. 골질이 D3인 상악 전치부의 골모형을 구성하고, 서로 다른 길이(8.5 mm, 10.0 mm, 11.5 mm, 13.0 mm, 15.0 mm)의 직경 4.0 mm 나사형 임플란트를 식립한 모형을 제작하였다. 해석 절차의 간소화를 위하여 모든 물성은 등방성, 선형탄성, 균질성으로 가정하였다. 골-임플란트 계면은 접촉 요소법으로 처리하여 골유착이 일어나기 전 상태로 구성하였다. 지대주 장축에 120도의 각도로 지대주의 구개 절단각 중앙부에 176 N의 정하중을 가하고 응력분포를 관찰하였다. von Mises stress를 이용하여 응력을 분석한 결과 모든 모형에서 순측 피질골에 응력이 집중되었으며 피질골과 망상골의 경계부에서 최대 응력값을 나타내었다. 길이에 따른 비교시 8.5 mm 모형에서 가장 큰 최대 응력값을 나타냈으며, 임플란트 길이가 증가될수록 좀 더 양호한 응력 분포를 나타내었다. 상악 전치부 즉시 하중시에 피질골의 존재 유무는 매우 중요하며, 길이가 긴 임플란트를 식립하는 것이 유리하며, 가능하면 13.0 mm 이상의 임플란트를 식립하는 것이 즉시하중을 시행할 때 응력 분산에 유리한 것으로 판단된다.

Computer guided implant surgery와 immediate loading을 활용한 무치악 환자의 전악 임플란트 고정성 보철물 수복 증례 (Implant-supported fixed prosthesis restoration of fully edentulous patient using computer-guided implant surgery and immediate loading: A case report)

  • 성현미;설경희;강선우;김정한
    • 대한치과보철학회지
    • /
    • 제62권2호
    • /
    • pp.131-139
    • /
    • 2024
  • 무치악 환자에서 임플란트를 이용한 보철치료는 임플란트 고정성 보철, 임플란트 융합 국소 의치, 하이브리드 보철물, 임플란트 유지 및 지지 피개의치 등의 다양한 방법이 있다. 본 증례에서는 중등도 이상의 만성 치주염에 이환 되어 전악 발치가 필요한 환자에서 computer guided surgery를 이용하여 계획된 위치에 임플란트를 식립하였다. 상악은 불량한 골질로 초기고정력이 충분하지 않아 지연 부하를 시행하였고 골 유착 기간 동안 임시 의치를 사용하였다. 하악은 안정적인 초기 고정을 얻어 즉시 부하를 이용하여 환자의 불편감을 감소시켰다. 임플란트 일차 안정은 즉시 부하를 얻기 위해 가장 중요한 요소로 여겨지기 때문에 수술 전 반드시 임상적, 방사선학적 평가를 통해 잔존 치조골 양 및 골질을 파악해야 한다.

Guidance and rationale for the immediate implant placement in the maxillary molar

  • Kezia Rachellea Mustakim;Mi Young Eo;Ju Young Lee;Hoon Myoung;Mi Hyun Seo;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제49권1호
    • /
    • pp.30-42
    • /
    • 2023
  • Objectives: While the reliability of immediate implant placement in the maxillary molar has been discussed, its significance is questionable. There have been no guidelines for case selection and surgical technique for successful treatment outcomes of immediate maxillary molar implants. Therefore, in this study, we classified alveolar bone height and socket morphology of the maxillary molar to establish guidelines for immediate implant placement. Materials and Methods: From 2011 to 2019, we retrospectively analyzed 106 patients with 148 immediate implants at the Department of Oral and Maxillofacial Surgery, Seoul National University Dental Hospital. Inclusion and exclusion criteria were applied, and patient characteristics and treatment results were evaluated clinically and radiologically. Results: A total of 29 tapered, sand-blasted, large-grit, and acid-etched (SLA) surfaces of implants were placed in 26 patients. The mean patient age was 64.88 years. Two implants failed and were reinstalled, resulting in a 93.10% survival rate. Fluctuating marginal bone level changes indicating bone regeneration and bone loss were observed in the first year following installation and remained stable after one year of prosthesis loading, with an average bone loss of 0.01±0.01 mm on the distal side and 0.03±0.03 mm on the mesial side. Conclusion: This clinical study demonstrated the significance of immediate implant placement in maxillary molars as a reliable treatment with a high survival rate using tapered SLA implants. With an accurate approach to immediate implantation, surgical intervention and treatment time can be reduced, resulting in patient satisfaction and comfort.

The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis

  • Sugiura, Tsutomu;Yamamoto, Kazuhiko;Horita, Satoshi;Murakami, Kazuhiro;Tsutsumi, Sadami;Kirita, Tadaaki
    • Journal of Periodontal and Implant Science
    • /
    • 제46권3호
    • /
    • pp.152-165
    • /
    • 2016
  • Purpose: This study investigated the effects of bone density and crestal cortical bone thickness at the implant-placement site on micromotion (relative displacement between the implant and bone) and the peri-implant bone strain distribution under immediate-loading conditions. Methods: A three-dimensional finite element model of the posterior mandible with an implant was constructed. Various bone parameters were simulated, including low or high cancellous bone density, low or high crestal cortical bone density, and crestal cortical bone thicknesses ranging from 0.5 to 2.5 mm. Delayed- and immediate-loading conditions were simulated. A buccolingual oblique load of 200 N was applied to the top of the abutment. Results: The maximum extent of micromotion was approximately $100{\mu}m$ in the low-density cancellous bone models, whereas it was under $30{\mu}m$ in the high-density cancellous bone models. Crestal cortical bone thickness significantly affected the maximum micromotion in the low-density cancellous bone models. The minimum principal strain in the peri-implant cortical bone was affected by the density of the crestal cortical bone and cancellous bone to the same degree for both delayed and immediate loading. In the low-density cancellous bone models under immediate loading, the minimum principal strain in the peri-implant cortical bone decreased with an increase in crestal cortical bone thickness. Conclusions: Cancellous bone density may be a critical factor for avoiding excessive micromotion in immediately loaded implants. Crestal cortical bone thickness significantly affected the maximum extent of micromotion and peri-implant bone strain in simulations of low-density cancellous bone under immediate loading.

Immediate Loading of Narrow Diameter Implants at the Mandibular Incisor Area Using Full Digital Flow: A Case Report

  • Ahn, Ji Ho;Lim, Young-Jun;Baek, Yeon-Wha;Lee, Jungwon
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.92-99
    • /
    • 2022
  • This case report describes the immediate loading of narrow diameter implants in the mandibular incisor area using full-digital flow. The 3-dimensional position of the implants was planned using digital software, and the corresponding surgical template was fabricated. The implants were inserted immediately after extraction and on the same day, the interim abutment and bridge were placed. At 8 weeks after surgery, the stability of the implants was measured and a digital impression was made using a scan body. Customized titanium abutments and a cement-type full zirconia bridge were delivered. At 36 weeks' follow-up, no clinical or radiographic complications were detected, and the patient was satisfied with the results.

인공치아의 즉시부하를 위해 새로이 개발된 인공치아 지대주(Satellite Abutment)의 광탄성 응력 분석 (PHOTOELASTIC STRESS ANALYSIS OF LOAD TRANSFER TO SATELLITE ABUTMENT AS AN IMMEDIATE ABUTMENT)

  • 박상규;이백수;;김부동
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제28권6호
    • /
    • pp.472-479
    • /
    • 2002
  • Since $Br^{\circ}anemark$ introduced the osseointegrated implants, they have been granted for useful methods for the restoration of oral function. The original $Br^{\circ}anemark$ protocol recommended long stress-free healing periods to achieve the osseointegration of dental implants. However, many clinical and experimental studies have shown that the osseointegration is no wonder in almost cases and that early and immediate loading may lead to predictable osseointegration. So we are willing to introduce the Satellite Abutment newly invented for immediate loading. We think that it will make the occlusal forces dispersed to surrounding bone and that we can restore the oral function immediately after implant installation not disturbing osseointegration. In case of using Satellite abutment, stress concentrated to bone contact area of implant was distributed not only fixation plate and screws but also superior, middle portion of implant and cortical layer of jaw bone. It was clearly decreased on the bone contact surfaces around dental implants. 1. Stress was decreased more than 76.5% when satellite straight abutment was used. 2. Stress was decreased more than 50% when satellite angled abutment was used. 3. The stress around dental implant was well distributed along the cortical bone surface and the fixation plate and screw. This study concludes that satellite abutment can be used as all immediate loading implant prothesis because it was possible to distribute periimplant occlusal stress through implant contact bone surface and cortical layer of jaw bone.